HomeMy WebLinkAbout2003 - Compliance Cert. Permit Number REScheck Compliance Certificate Checked By/Date 1995 MEC REScheckSoftware Version 3.5 Release 1a Data filename: C:\Program Files\Check\REScheck\Myhran.rck TITLE:Addition and Remodeling for the Myhran Residence CITY:Orono STATE:Minnesota HDD: 8037 CONSTRUCTION TYPE:Single Family DATE:05/30/03 DATE OF PLANS:5/30/03 COMPLIANCE:Passes Maximum UA= 187 Your Home UA= 175 6.4%Better Than Code(UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1: Raised or Energy Truss 816 44.0 0.0 18 Wall 1:Wood Frame, 16"o.c. 810 19.0 0.0 37 Window 1: Wood Frame:Double Pane with Low-E 156 0.350 55 Door 1:Solid 18 0.300 5 Door 2:Glass 20 0.350 7 Floor 1:All-Wood Joist/Truss:Over Outside Air 15 38.0 0.0 0 Crawl 1:Masonry Block with Empty Cells 607 10.0 0.0 53 Wall height:4.0' Depth below grade:3.5' Insulation depth:3.5' COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans,specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 1995 MEC requirements in RES checkVersion 3.5 Release la (formerly MECchecJ and to comply with the mandatory requirements listed in the RES checklnspectio -: cklis Buil. r/Designer / Date 45/31/43 ' • REScheck Inspection Checklist 1995 MEC REScheckSoftware Version 3.5 Release la DATE: 05/30/03 TITLE:Addition and Remodeling for the Myhran Residence Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1: Raised or Energy Truss,R-44.0 cavity insulation Comments: Insulation must achieve full height over the plate lines of exterior walls. Above-Grade Walls: [ ] 1. Wall 1:Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: Windows: [ ] 1. Window 1: Wood Frame:Double Pane with Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: Doors: [ ] 1. Door 1: Solid,U-factor:0.300 Comments: [ ] 2. Door 2:Glass,U-factor:0.350 Comments: Floors: [ ] 1. Floor 1:All-Wood Joist/Truss:Over Outside Air,R-38.0 cavity insulation Comments: Crawl Space Walls: [ ] 1. Crawl 1:Masonry Block with Empty Cells,4.0'ht/3.5'bg/3.5'insul, R-10.0 cavity insulation Comments: Applies to walls of unventilated crawl spaces. Air Leakage: [ ] Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a 3"clearance from insulation. Vapor Retarder: [ ] Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. Duct Construction: [ ] All ducts must be sealed with mastic and fibrous backing tape. Pressure-sensitive tape may be used for fibrous ducts. Duct tape is not permitted. [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] I HVAC piping conveying fluids above 120 °F or chilled fluids below 55 °F must be insulated to the levels in Table 2. • Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature(F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range(F) 2"Runouts 1"and Less 1.25"to 2" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only)