Loading...
HomeMy WebLinkAboutSeptic System Inventory SEPTIC SYSTEM INVENTOR Y Address: 10 Willow Dr. S. PID: 03-117-23 22 0010 Building Typ residence #BRs/GPD: 3 #Systems 1 Units Billed 1 Permit#: 5157 Date of Permit: 5/11/78 Installer: Westonka Plbg. System Type standard trench Experimental: no Appliances lndry,dshw,dspl SYSTEM CONDITION Conformity: 3 Tank Condition: 10 DF condition: 11 Failure Pot: medium SEPTIC TANKS Material: concrete block Capacity: 1000, 850 Setback to Bldg: 29 Cesspool: DRAINFIELD Length of Lines 330 #Lines: 3 Trench Width: 3 Treatment Area: 1000 Type of Filter rock Soil Boring: no Tile Size: 4 Under Tile 12 Perc Rate: 5 Setback DF-Bldg: 30 DF Ht above Wt: Soil Type: sandy clay loam Limitations: WELL DATA Setbacks - Well-Tanks: 80 Well-DF: 90 Report in File yes Pump Type: subm. Depth: 343 Diameter: 4 Method: drilled INSPECTIONRECORD PUMPOUT RECORD DATE DESCRIPTION COMPLIANCE DATE GALLONS 5/26/78 installation c 3/18/81 2000 8/17/81 no surfacing 1 7/28/92 1600 9/11/86 no surfacing 1 3/16/87 no surfacing 1 10/23/91 no surfacing-pump tanks 1 11/3/93 no surfacing 1 10/30/95 no surfacing-pump tanks 1 8/26/99 Noncompliant/repair by 12/31/2009 3