HomeMy WebLinkAboutOnsite sewage treatment systems CITY Of ORONO )' Municipal Offices Street Address: Mailing Address: K0 2150 Kelley Parkway P.O. Boz 66 -- Orono, MN 55356 Crystal Bay, MN 55323.0066 To: The Current Owner of Address I l&c, AJ City Ordinance requires that onsite sewage treatment systems in Orono be inspected on a periodic basis. The onsite sewage treatment system at the above address has been inspected and the following is known about the system. A sketch of the known components of the system is available for most properties at the Orono City Hall. Imminent Public Health Threat Yes No If yes, please contact the Onsite Systems Manager at 952-249-4626 within 10 days of receipt of this notice. The septic system must be brought into compliance within 90 days. Failure to do so will result in referral to the City Attorney for legal action. System Identi d as Non-Compliant Yes No If yes, system must be brought into compliance by: December 31, 2007 December 31, 2010 Other Septic Tanp out Needed Yes No The City recommends the septic tank(s) and/or lift tank be serviced and pumped out every three years. City records indicate the tank(s) were last pumped out on VS -01 The tank(s) should be cleaned tl—ough the manhole and not tluouah the inspection pipes, this allows for proper cleaning. Comments: r• ' Inspec Date of Inspection t -c ` 0 0 s CITY of ORONO Municipal Offices t ` \V4� F �G Street Address: c S%-a49-460 0 Mailing Address: "0 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 To Current Owner: Address: r �(- A/ ' City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFORMITY (1-3): 3 1 "CODE SYSTEM"An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and which is not failing or an imininent threat to public health or safety. O"NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any reason;and any ISIS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. TANK CONDITION(5-7): 6 Tank inspection indicates: Pumpout not needed at this time. Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. Tank was last pumped Make sure septic tanks are pumped through manhole and not through white inspection pipes. This allows for the proper cleaning. Keep water softner and iron filter discharge out of septic system to prolong life of drainfield. Ask pumper to test alarm float to verify alarm is still working in your house. The alarm warns owner that septage is about to backup into basement. 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If tanks have not been pumped out within the last three years,they should be pumped out now. PI&AMIELD CONDITION 8-10 : 0 Drainfield is dry,no surfacing evident. 9 Some evidence of surfacing,not critical yet. 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately.Repairs must be completed within 90 days. CONMIENTS: �S o�� �Jt�� ,S r� C b •� n..� �- 1��ss�' Date of Inspection Matt Bolterman- Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current conditions based on the available information. =rte CITY of ORONO i i 4 � ' +� 'ti►� Municipal Offices g� Street Address: ss: 2750 Kelley Parkway P.O. Boz Mailing Address: Orono, MN 55356 66 Crystal Bay, RN 55323.0066 95d-�4q-y600 To Current Owner: Address: 1160 \''`'_�Al City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. SYSTENJ CONFORMITY (1-3): 1 "CODE SYSTEM"An ISIS which meets all the location,design and construction standards of the current Orono Municipal Code. 2 "CO'NIPLIANT SYSTEM" An ISIS which does not meet all the location,design and construction standards of the current Orono Municipal Code but docs meet the three foot separation requirement or two foot requirement for systems installed 1196 or earlier,and which is not failing or as immincnt threat to public health or safety. 30'NON,-COMPLIANT SYSTEM" A prohibited ISIS;an ISTS located within a designated 100-year flood plain,any ISTS which may or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. TANK CONDITION(►-:71: _ Tank inspection indicates: QD Pumpout not needed at this time. 6 Septic tants must be pumped out this year (city code requires tanks to be pumped out once every 3 years. Tank was last pumped Make sure septic tanks are pumped through manhole and not through white inspection pipes This allows for the proper cleaning. 7 Inspection risers missing tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tack. D INFIELD CONDITION 9-tQ : --C 8 Drainfield is dry,no surfacing evident. 9 Some evidence of surfacing,not critical yet. 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately.Repairs must be completed within 90 days. CONLMENT Qc�,:�'����1 S f�L`c�— Cc) I C, C-Ar\ r \11C 64 d . Da:-.of Inspection Matt Bolterman - Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other tramferofpropery.be advised that this report does not gu nn e orcc tify tl at an existing system will continue to function prop<rly,but is merely an opinion afthe adequacy of the system under current conditionsbised on the availabl information. O O =- !� CITY of ORONO Municipal Offices t Street Address: Mailing Address: ' gp¢' 2750 Kelley Parkway P.O. Box 66 August 29, 2000 Orono, MN 55356 Crystal Bay, MN 55323-0066 Clifford A. Hillstrom 1160 Willow Drive North Long Lake, Mn 55356 Dear Mr. Hillstrom: An inspection of your septic system was conducted on August 28, 2000. A summary of the inspection is below. Septic Tank Condition 1. Pumpout needed within one year(last pumpol date 3/13/96). The septic system is non-compliant due to a lack of a three foot separation distance between the bottom of the drainfield to the seasonally high watertable. The three foot requirement is a State Code,not a City Code. A soil boring was conducted to determine the depth of the seasonally watertable. The septic system must be replaced by December 31,2010. Enclosed is a list of state licensed septic contractors who work in Orono on a regular basis. Also enclosed is a fact sheet explaining how a septic system functions properly. Finally, an as-built drawing is enclosed that shows the approximate location of the septic system. If you have any questions regarding this report, please contact me at the City Offices at 249-4600. Res ectful , Chris Pence On-Site Systems Manager Enclosures In the event this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does no guarantee or certify the existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the system location and pumping records. Telephone(952)2494600 • Fax(952)2494616 www.ci.orono.mn.us O O .,T CITY of ORONO y. Municipal Offices t:T Street Address: Mailing Address: 2150 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 Owner: 4115T3mAddress: 1160 Willow Dr. N. Permit #'s: 5250 Dates: 7/19/76 Contractors: E. J. Peterson (This is (X] an existing system [ ] new construction) . SYSTEM COMPLIANCE (1-3) : 3 1 Code System: Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. 2 Compliant System: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance with previous codes and is functioning properly. 3 Non-Compliant System: System may or may not meet current City standards for design, construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level. (The saturated soil level is (}� ] or is not [ ] identified under this septic system. If the saturated soil level is not identified, this classification is subject to revision.) TANK CONDITION (5-9) : 9 5 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year. 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out within three years, they should be pumped out and risers installed now. Inspection pipe_ is located over tank baffle-can not measure solids accumulation. If tanks have not been pumped out within three years, they should be pumped out now. 10 One or more tanks are cesspools, which means the septic system is non-compliant. (The tanks are [ ] or are not [ ] -water tight or the condition is [A unknown. If the tanks are not confirmed to be watertight, this classification is subject to revision.) DRAINFIELD CONDITION (11-14) : 14 11 Drainfield is dry, no surfacing evident. 12 Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : high COMMENTS: In order to confirm that your septic system meets Minnesota standards, soil borings were performed to verify a 3 foot separation between the drainfield and the seasonal water table. The separation is 0 feet and the system is non-compliant. Repair or replacement of the septic system is required by 12/31/2008. Date of Inspection 4ept* ystem Inspector Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicates the operation of the system under current conditions. Telephone (612) 473-7357 a FAX 473.0510 CITY OF ORONO �O O Municipal Offices O Post Office Box 66 Crystal Bay, MN 55323-0066 ON-SITE SEWAGE TREATMENT INSPECTION REPORT ti 9kEs goy' Owner: ( �1 fT1 � Y'()�'� Address: //(ll J !/lAn,) NY. A Permit #�'s: Dates: /7 _Contractors: L►. 1 1&`p G. City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is L(j an existing system t ) new construction) SYSTEM CONFORMITY (1-3): 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic ( ) has orhas not been identified at this time. If the limiting soil characteristic has not been identified, this c assification may be subject to revision.) TANK CONDITION (5-10): -7— �� ID Tank inspection indicates: 5 Pum pout not needed a is time. Solids accumulatio n tanks indicates they should be oblems. in tanks is at a critical level s should be out as soon as possib 8 System is discharging to the-913fface. aanKS'MUST Be ou wt ace discharge. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed to each tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped out now. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been pumped out within the last three years, they should be pumped out now. DRAINFIELD CONDITION (11-14): Drainfield inspection indicates: 11 Drainfield is dry, no surfacing evident. 12 Some evidence of surfacing, not critical yet. Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (slope.setbacks.etc.): POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table.etc.): o � � CO N S: (/ ve mizsLbe Date of Inspection Septic Sys e for - , pvpve4 Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer d'f y/�_ property, be advised that this report does not guarantee or certify that an existing system will continue to function 1^� properly, but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the system location and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner CITY OF ORONO O Municipal Offices O O Post Office Box 66 Crystal Bay, MN 55323-0066 ON—SITE SEWAGE TREATMENT INSPECTION REPORT ti ��9kEsHo��G Owner: 6/)yMaj &LM0rr_`,AddreBS: Z,1,4101,J 101, J JA y QQ -�^ 1 Permit #'s: 4 S� Dates: ��q 7d Contractors: /rte City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is b4, an existing system [ ) new construction) SYSTEM CONFORMITY (1-3): 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The Limiting soil characteristic [ ) has or D;. has not been identified at this time. If the limiting soil characteristic has not been identified, this classification may be subject to revision.) TANK CONDITION (5-10): Tank inspection indicates: 5 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (41, dia. pipe) must be installed in each tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped out now. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been pumpedoutwithin the last three Years, they should be pumped out now. DRAINFIELD CONDITION (11-14): Dr field inspection indicates: 1 Drainfield is dry, no surfacing evident. Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (slope,setbacks.etc.): POTENTIAL FOR SYSTEM FAILURE (depends on soiLs.water table.etc.): /nt��•�T,` COMMENTS: n h Date of Inspection Yeipy1c System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the system location and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner On the North Shore of Lake Minnetonka ON-SITE SEWAGE TREATMENT CITY INSPECTION REPORT OF an POST OFFICE BOX 66 1335 S. Brown Rd. O R OO Crystal Bay, MN 55323 473-7357 OWNER __�_/��U►'A j/� 1/l DI�� ADDRESS &l"91/0t­l 51 PERMIT NO.'S. DATES 7`7 CONTRACTORS �/ Z4?14�.�tN City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The onsite sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is P( an existing system ❑ new construction) 1 Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating properly. 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, located, and constructed generally in accordance with previous codes.System appears to be functioning properly;no major upgrading of the system is required at this time. 3 Does not meet current City standards in many respects relating to design,construction,or location.Appears to be operating adequately at this time,but has a relatively high potential for future problems. No major upgrading of system is required at this time. 4 System may or may not meet current City standards for design,construction or location, but is failing to properly treat and dispose of the current input,and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is creating a safety hazard,or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/ replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan must be submitted for review.Your contractor must obtain a permit before work is started. SYSTEM CONDITION.( m Checked items may require your action) Tank'nspection indicates: ❑ Inspection pipe is located directly over tank baffle.(Does not Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks Solids accumulation in tanks indicates they should be pump- have not been pumped out within the last three years,they ed out this year to help prevent future problems. should be pumped out now. ❑ Solids accumulation in tanks is at a critical level. Tanks Drainfield inspection indicates: should be pumped out as soon as possible. ❑ Drainfield is dry,no surfacing evident. ❑ System is discharging to surface. Tanks must be pumped ❑ Some evidence of surfacing,not critical yet. within 48 hours to eliminate surface discharge. ❑ Drainfield is saturated and visibly discharging untreated ❑ Inspection risen missing—tanks could not be inspected, effluent to the surface. This condition may require replace- Inspection risers (4"dia. pipe)must be installed in each tank ment or additions to drainfield. Contact the City Inspector at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days. the last three years,they should be pumped out now. 70 Drainfield extent and condition unknown. SITE CHARACTERISTICS: Limiting Site Factors Potential for System Failure Site Capabilities for ❑ Slope (depends on soil types,water Future Expansion ❑ Soil table,and system condition) ❑ Adequate ❑ High water table Low J8 Fair ❑ Lot size Medium ❑ Poor ❑ Lake,wetland,or stream High ❑ Inadequate ❑ Drainage ❑System is causing visible surface discharge. COMMENTS: Date of Inspection Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with system location and pumping records. WHITE COPY/Inspector's File GOLD COPY/Homeowner On the North Shore of Lake Minnetonka ON-SITE SEWAGE TREATMENTCl TY INSPECTION REPORT OF POST OFFICE BOX 66 O.O O 1335 S. Brown Rd. Crystal Bay, MN 55323 473-7357 OWNER I��lt c � ��St►oyVl ADDRESS 1160 Al' WI11OW Dc iVe_ PERMIT NO.'S. ✓�ZSa DATES 7` « -78 CONTRACTORS ELI _4_-hA 0,o City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is �Ian existing system El construction) 1 Meets or/ current City standards in all respects relating to design,construction,and location.Appears to be operating properly. 92 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, flocated, and constructed generally in accordance with previous codes.System appears to be functioning properly;no major upgrading of the system is required at this time. 3 Does not meet current City standards in many respects relating to design, construction,or location.Appears to be operating adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at this time. M4 System may or may not meet current City standards for design,construction or location, but is failing to properly treat and dispose of the current input,and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is creating a safety hazard,or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/ replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan must be submitted for review.Your contractor must obtain a permit before work is started. SYSTEM CONDITION Checked items may require your action) Ta k'nspection indicates: ❑ Inspection pipe is located directly over tank baffle.(Does not Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks ❑ Solids accumulation in tanks indicates they should be pump- have not been pumped out within the last three years, they ed out this year to help prevent future problems. should be pumped out now. ❑ Solids accumulation in tanks is at a critical level. Tanks Dr infield inspection indicates: should be pumped out as soon as possible. Drainfield is dry,no surfacing evident. ❑ System is discharging to surface.`Tanks must be pumped Some evidence of surfacing,not critical yet. within 48 hours to eliminate surface discharge. ❑ Drainfield is saturated and visibly discharging untreated ❑ Inspection risers missing—tanks could not be inspected, effluent to the surface. This condition may require replace- Inspection risers 14" dia. pipe) must be installed in each tank ment or additions to drainfield. Contact the City Inspector at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days. the last three years,they should be pumped out now. ❑ Drainfield extent and condition unknown. SITE CHARACTERISTICS: Limiting Site Factors Potential for System Failure Site Capabilities for ❑ Slope (depends on soil types,water Future Expansion ❑ Soil tablkjnd system condition) ❑ Adequate ❑ High water table ^Low X,Fair Lot size ❑ Medium ❑ Poor Lake,wetland,or stream ❑ High ❑ Inadequate ❑ Drainage ❑ System is causing visible surface discharge. COMMENTS: at J !'l4deo 42LtyA 1605 er act auaau .�3 1 roars lb auz[ .( -_005f1u YL(7Gil r^ bl I!S - Senc Cl-c/G((� _ qusf ate of Inspection Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with system location and pumping records. WHITE COPY/Inspector's File GOLD COPY/Homeowner On the North Shore of Lake Minnetonka ON-SITE SEWAGE TREATMENTCITY INSPECTION REPORT OF POST OFFICE BOX 66 O_ONO 1335 S. Brown Rd. ilk Crystal Bay, MN 55323 473-7357 I/ C !FG f[..L S7( r t ( l b Q �, �1 L L Q 14 1).K OWNER 14aO- ADDRESS 1 PERMIT NO.'S. Z- U DATES 2 — 11 CONTRACTORS Ej City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The on-site sewage treatment system at the above dress has been inspected and appears to fall into the category checked below. (This is an existing system ❑ new construction) 1 Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating properly. 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, located, and constructed generally in accordance with previous codes. System appears to be functioning properly; no major upgrading of the system is required at this time. ❑ 3 Does not meet current City standards in many respects relating to design,construction, or location.Appears to be operating adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at this time. 4 System may or may not meet current City standards for design,construction or location, but is failing to properly treat and dispose of the current input, and is endangering a water supply, or is a source of pollution to surface or groundwaters,or is creating a safety hazard,or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/ replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan must be submitted for review.Your contractor must obtain a permit before work is started. SYSTEM CONDITION ( m Checked items may require your action) nk inspection indicates: ❑ Inspection pipe is located directly over tank baffle.(Does not Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks ❑ Solids accumulation in tanks indicates they should be pump- have not been pumped out within the last three years, they ed out this year to help prevent future problems. should be pumped out now. ❑ Solids accumulation in tanks is at a critical level. Tanks Drainfield inspection indicates: should be pumped out as soon as possible. ❑ Drainfield is dry,no surfacing evident. ❑ System is discharging to surface. Tanks must be pumped ❑ Some evidence of surfacing,not critical yet. within 48 hours to eliminate surface discharge. ❑ Drainfield is saturated and visibly discharging untreated ❑ Inspection risers missing—tanks could not be inspected. effluent to the surface. This condition may require replace- Inspection risers (4" dia. pipe)must be installed in each tank ment or additions to drainfield. Contact the City Inspector at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days. the last three years,they should be pumped out now. Drainfield extent and condition unknown. SITE CHARACTERISTICS: Limiting Site Factors Potential for System Failure Site Capabilities for ❑ Slope (depends on soil types,water ` Future Expansion ❑ Soil le,and system condition) __'tEl Adequate \❑ High water table Low ❑ Fair �] Lot size ❑ Medium ❑ Poor ❑ Lake,wetland,or stream ❑ High ❑ Inadequate ❑ Drainage ❑ System is causing visible surface discharge. COMMENTS: Ac.G��r 27 0786 Date of Inspection ptic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with system location and pumping records. WHITE COPY/Inspector's File GOLD COPY/Homeowner