HomeMy WebLinkAboutSeptic System Inventory (2) SEPTIC SYSTEM INVENTORY
Address: 190 Willow Dr.N. PID: 34-118-23 33 0054
Building Type residence BRs Install'd for: 3 In Musa: Yes
Permit#: 4657 Date of Permit: 10/22/76 Installer: Thompson Plbg.
System Type: standard trench Experimental: no Tank Filter:
SYSTEM CONDITION
Conformity: 3 Tank Condition: 5 DF condition: 11 Failure Pot: medium
SEPTIC TANKS
Material: concrete precast& Capacity: 1500, 500
Setback to Bldg: 15 Cesspool: no
DRAINFIELD
Length of Lines: 400 #Lines: 4 Trench Width: 2.5
Treatment Area: 1000 Type of Filter: rock Soil Boring: yes
Tile Size: Under Tile: Pere Rate: 30
Setback DF-Bldg: 30 DF Ht above Wt: 0
Soil Type: fine sand Limitations: water table
WELL DATA
Setbacks - Well-Tanks: 55 Well-DF: 75 Report in File yes
Pump Type: subm. Depth: 221 Diameter: 4 Method: drilled
INSPECTION RECORD PUMPOUT RECORD
DATE DESCRIPTION COMPLIANCE DATE GALLONS
8/17/81 no surfacing 2 4/5/85 1500
8/28/86 no surfacing 2 5/1/91 2000
8/4/88 no surfacing 2 3/24/94 1500
10/23/91 no surfacing 2 5/1/97 2000
11/3/93 no surfacing 2 4/12/00 2000
10/26/95 no surfacing 2 4/25/01 10800
5/18/98 non-compliant repair by 12/31/2008 3
8/28/00 non-compliant, repair by 12/31/2010 3
10/28/02 non-compliant,replace by 12/31/2010 non-compliant