Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Septic System Inventory
SEPTIC SYSTEM INVENTORY Address: 3800 Wayzata Blvd. PID: 29-118-23 34 0002 Building Type:daycare BRs Install'd for: 650 In Musa: No Permit#: 6670 Date of Permit: 4/29/82 Installer: Patnode Bros. System Type: mound Performance: no Tank Filter: SYSTEM CONDITION Conformity: 1 Tank Condition: 6 DF condition: 8 Failure Pot: low SEPTIC TANKS Material: precast concrete Capacity: 1000, 1000, 500 Setback to Bldg: 10 Cesspool: DRAINFIELD Length of Lines: 160 # Lines: 3 Trench Width: 10 Treatment Area: 80*40 Type of Filter: rock,clean sand Soil Boring: yes Tile Size: 1.5 Under Tile: 9 Perc Rate: 40 Setback DF-Bldg: 30 DF Ht above Wt: 3 Soil Type: sandy clay loam Limitations: water table WELL DATA Setbacks - Well-Tanks: 100 Well-DF: 75 Report in File yes Pump Type: subm. Depth: 139 Diameter: 4 Method: drilled INSPECTION RECORD PUMPOUT RECORD DATE DESCRIPTION COMPLIANCE DATE GALLONS 5/21/80 DF cut off during road construction 1 6/8/82 replacement installation 1 9/10/86 no surfacing-cut trees on mound 1 8/30/90 no surfacing-cut trees,pump tanks 1 7/9/91 no surfacing-cut trees,pump tanks 1 9/3/93 no surfacing-cut trees,pump tanks 1 10/2/96 no surfacing-cut more trees,pump tanks 1 9/8/99 conforming system-cut trees,pump tank,1 10/02/01 no surfacing, pump tanks 1 13 0 t 0.'AS T-0 13o2 (2 A 2e6 v /Jczyz�oL4ct we'll (r� well) \ � \ / / . \ / \ ` \ \ \ / \ . / � . k^�//( 7 / � 61 /0^~~ �� RID ��� '/ )� �� �-~�