HomeMy WebLinkAboutSeptic System Inventory �J y II I SEPTIC SYSTEM INVENTOR Y Address: 3580 Wayzata Blvd. PID: 32-118-23 12 0001 Building Type residence BRs Installed for: 2 In Musa: No Permit#: 6008 Date of Permit: 6/12/80 Installer: Hayes Exc. System Type: standard trench Performance: no Tank Filter: SYSTEM CONDITION Conformity: 3 Tank Condition: 5 DF condition: 8 Failure Pot: med SEPTIC TANKS Material: precast concrete Capacity: 1000, 1000 Setback to Bldg: 10 Cesspool: ? DRAINFIELD Length of Lines: 66 # Lines: 4 Trench Width: 3 Treatment Area: 800 Type of Filter: rock Soil Boring: yes Tile Size: 4 Under Tile: 6 Perc Rate: Setback DF-Bldg: 20 DF Ht above Wt: 0.8 Soil Type: loam, clay loam Limitations: water table WELL DATA Setbacks - Well-Tanks: 50 Well-DF: 70 Report in File yes Pump Type: subm. Depth: 176 Diameter: 4 Method: drilled INSPECTION RECORD PUMPO UT RECORD DATE DESCRIPTION COMPLIANCE DATE GALLONS 6/12/80 added tanks 2(1000 gal.), DF (800) sf 1 5/5/97 2000 9/10/86 no surfacing 1 9/21/01 2000 8/30/90 no surfacing-need risers, pump tanks 1 7/9/91 no surfacing 1 9/3/93 non-conforming-repair by 12/31/95 3 10/1/96 noncompliant-repair by 12/31/96 3 8/31/99 noncompliant-repair by 12/31/2003 3 11/14/01 no surfacing, pump tanks 3 10/23/03 house to be demoed non-compliant w!-e