Loading...
HomeMy WebLinkAbout2003-P05937 - sprinkler system CITY d5F ORONO PERMITPermit Number: 2750 Kelley Parkway- PO Box 66 P05937 Crystal Bay, Minnesota 55323 Permit Type: Fire systems Permit (952) 249-4600 Date Issued: 1/6/2003 SITE ADDRESS: 2687 Wayzata Blvd W Long Lake,MN 55356 PID: 33-118-23-13-0002 DESCRIPTION: Proposed Use: Permit Class: General Permit Type: Fire Systems Permit Permit Sub-type(s): Sprinkler System DETAILS: Approved per resolution#: Separate permits required: NOTICES/REMARKS: FEE SUMMARY: Permit Fee: $ 384.50 Valuation: $ 30,760.00 Plan Review Fee: $ 293.70 State Surcharge Fee: $ 15.38 TOTAL FEE: $ 693.58 APPLICANT: Response Fire Protection Company,Inc. OWNER: (Western Steel)Ace Properties,LLC 8201 Old Central Avenue,Suite E 5500 Anderson Estates Spring Lake Park,MN 55432 Maple Plain,MN 55359 THE UNDERSIGNED HEREBY REQUESTS PERMISSION TO MAKE THE REAL IMPROVEMENTS SPECIFIED AND AGREES TO DO ALL WORK IN STRICT COMPLIANCE WITH ALL CITY OF ORONO ORDINANCES AND STATE OF MINNESOTA BUILDING CODE REQUIREMENTS. APPLICANT P RMITEE SIGNATURE IS Y SIGNATURE ;i97R� Conies: 1-File(SiQnitures Required). 1-Anulicant, 1-Monthly Reports, 1-Assessing, 1-Finance Page 1 � �5L I �3J7 CITY OF ORONO APPLICATION FOR Box 66 (2750 Kelley Parkway) FIRE SPRINKLER SYSTEM PERMIT Crystal Bay, MN 55323 GENERAL INFORMATION 1. Permits are required for all fire sprinkler installation and repair. All work shall be done by a licensed fire sprinkler contractor. 2 sets of plans, specification and hydraulic calculation sheets shall be submitted to the Orono Fire Marshal a minimum of 7 days before start of work. 2. You may apply for permits by mail or in person at the City offices. 3. All systems shall be designed, installed and maintained to N.F.P.A.-13, N.F.P.A.-25, and Minnesota State Building Code, Minnesota Uniform Fire Code and Standards. All attic systems are to be spaced at a maximum of 130 square foot coverage. Plastic pipe will not be allowed at any time in attic spaces. 4. All equipment installed shall be U.L. or F.M. approved for fire protection service. 5. Yard or wall post indicator valves are required. All indicting and control valves installed shall be provided with tamper protection. On dry systems, the control valve to service the pressure switch (air) shall be supervised. 6. Inspectors test valves shall be installed on each floor level or zone of system. Main drain and inspectors test valves shall be piped to the outside. 7. No water is to be introduced into the sprinkler system until main had been thoroughly flushed. Air test and flushing shall be witnessed by City of Orono Water Department. 8. An approved audible/visual device wired to main flow switch shall be installed above the Fire Department connection and in areas normally occupied by tenants. 9. EXISTING SYSTEMS: If any changes in the hydraulically most demanding area, change in occupancy classification or addition of 20 or more heads, hydraulic calculations and flow test will be required. 10. All final flow or trip tests shall be witnessed by the Orono Fire Marshal. Appointments can be made by calling Orono City offices, (612)249-4600. 24-hour notice required. 11. ALL WORK (rough-in and final) MUST BE INSPECTED. PERMITS ARE NOT VALID UNTIL YOU RECEIVE A PERMIT AND JOB-SITE CARD. Call(612)249-4600 24-hours in advanced to schedule your inspections. Instructions Complete all items on this application. Compute the permit fee. Sign and date the certification. INCOMPLETE APPLICATIONS WILL NOT BE PROCESSED. If you have questions, call 249-4600. You will be notified by phone when the permit review is completed. Permit will be issued to contractors at the City offices (2750 v` ay). . ' C,4 1,5 Please check one: V New A, r-\bU S Replace JOB SITE: lt� � L- - i �t p(lori6 �"�� p: Owner's Name: % Mailing Address: ZC� lG6k�J y �7, JNrt`' P o dip: Sprinkler Contractor: 4SP4� )r14(5 PJ� _ -.w►i elephone Number:11n�''7/7 if 7-/0 Contractor's Address: FZ0IOG-PCe4l�_VL vE Srr�5City: (.Key- Zip: �r'5;4 in- Contact Contact Person: ,� l� Phone Number: -76 5--711- q__1 0 (Circle one: Cell, Pager Office PERMIT FEE CALCULATION 1. 1.25% of Contract Price* or Minimum Fee 35.00 -� x .0125 $ �j (contract price) 2. State Surcharge. ** Add the State Building Code �Rivision 3q Surcharge to each permit. 2,� "u�(�©� x .0005 $ or $.50, whichever is greater (contract price) 3. Postage and Handling (Only mail-in applications) $ 4. TOTAL PERMIT FEE (Add lines 1-3 above) $ '�!a * CONTRACT PRICE or JOB COST means the actual or estimated dollar amount charged for the permitted work including materials, labor, profit, and other fixed costs. It is the amount to be charged to the customer for the work done. If any material, equipment, labor, or installation are furnished by the owner, tenant or any other parry the reasonable market value of such items must be added to the estimated cost or contract price for permit fee purposes. In the event that there is a dispute on the amount of the job cost, the City may request the submission of a signed copy of the actual contract. ** The STATE SURCHARGE is .0005 of the contract price under $1,000,000 or $.50 - whichever is greater. For valuations over$1,000,000 call the Department of Inspectional Services for the price. The undersigned hereby applies to the City for issuance of a Sprinkler System Permit, agrees to do all work in strict accordance with the ordinances of the City and the regulations of N.F.P.A. 13, and certifies that all statements made on this application are complete, true and correct. Applicant's Signature: Date: Approved By: -- Date: //-z Z 0 3 ORONO CUTYmatic Sprinklers- Response Fire Protection Company, Inc. Engineering•Installation Service•Special Hazards 8201 Old Central Avenue,Suite E Halon Spring Lake Park,MN 55432 (763)717-4740 Fax: (763) 717-4741 Transmittal Form ToCity of Orono Date December 18, 2002 2750 Kelley Pkwy /PO box 66 Subject Western Steel Orono, MN 55323 2687 Highway 12 Orono, MN AttentionLyle Oman Job No. 22421 sh Drawings No. Copies Sheet No. Description For Approval 5 I of 1 Fire sprinkler shop drawings for approval Approved _ ❑ Approved as Noted 5 copies of 3 sets Of calculations ❑ Not approved-Resubmit 1� ❑ For your use 5 Information on type of sprinklers to be used ❑ For distribution Prints *We will require pproved copies for our use. Notes/Comments: By: MARK W. CARLSON ' UP 81`a U+ City of Orono Fire Marshal December, 312002 To; Response Fire Protection 8201 Old Central Avenue SLP, MN, 55432 Attn.- Mark or Tom From; William Meyer, FM City of Orono Re; Plan review, Western Steel 2687 West Wayzata Blvd. Job 4 22421 Sirs, The fire sprinkler plan submitted for the above mentioned address has been approved with the following changes: A; The fire department connection shall be relocated to the front(Highway 12, Wayzata Blvd.) side of the building. The horn/strobe for the main water flow shall be mounted high enough to be seen from front highway. B; AudibleNisual devices shall be installed throughout office and shop areas to warn occupants to evacuate. If you have any questions, I can be contacted at 612- 640- 5312,pager Zo . C, 4AI cc Lyle Oman, City building Official $ y V* Iv jf NO *'4 • �� E'" A• K + W ARK II, 4:.. + _ I i ty ^ ' a ... � >,�. .v�C �� '";�� � ♦., z .� «' .mss • • _ , r fit.. =+`c, r` r If i • K *a k Af s r y 4 ry r T ♦ �/`/moi.-yy�y• R ♦ t !S ''./ °'M"/y t ..�. ►� ,J�.,I yrs# %!�.�� t� � �,r` f. �+ ..� �► i ` � 1 3 �! `, tC'c.',•'�''l ,�►<;!f�`!+ � t�s a� :Jf` i�.�.,'�`. job T - • JAN-10-2003 15:08 MINNEHAHA CREEK WATERSHED 6124710682 P.02i02 Nimaebaka Creek Watershed District Improving Quality ofWater, Quality of Life Established in 1,967 Mall: Pursuant to Minnesota Statutes Chapter 103D, and on the basis of statements 18202 Minnetonka Blvd., and information contained in the permit application, correspondence, plans, Deephaven,MN 65391 maps, and all other supporting data submitted by the applicant, all of which are Phone:(952)471-0590 made a part hereof by reference, PERMISSION IS HEREBY GRANTED to the applicant named below for use and development of land in the Minnehaha Creek Fart(952)471-0682 Watershed District. Eoall: Issued to: Mike& Carmen Rodewald Permit No:02-234 admin®minnehalwreek.org Web Site: Location: 4760 West Branch Rd. Orono wwwrrinnehahacreek.org Purioose: Rule B, Erosion Control, Rule D: Wetland Protection Date of Issuance: 07/25/02 Date of Expiration: 07/25/03 I By Order of the Board of Managers Board of Managers Pamela 0.Biba Michael Wyatt James Calkins District Technician Lance Fisher This permit is not transferable, and is valid to the date of expiration. No activity is Monica dross authorized beyond the expiration date. If the permittee requires more time to ScottThomas complete the project, an application for renewal of the permit is required. Richard Miller The applicant is responsible for compliance with all District Rules and for the Robert Schroeder action of their representatives, contractors, and employees. Conditions: Project to be completed as described in plans submitted to the MCWD office on July 11, 2002 according to the provisions of this permit. • Properly install and maintain all required MCWD Rule B, erosion control measures until the disturbed areas are restabilized • Silt fence must be orange in color • When the site is restablilized and the MCWD staff has performed a final inspection, all silt fences must be removed (Statement concerning fees for inspections, violations, etc... on reverse) ®X90 TnTA1 P A7