HomeMy WebLinkAbout2013-00724 - fire sprinkler system J-1 CITY OF ORONO * 2013 - 00724 * 2750 KELLEY PARKWAY DATE ISSUED: 07/29/2013 ORONO, MN 55356- (952) 249-4600 FAX: (952)249-4616 ADDRESS 2725 WAYZATA BLVD W PIN 33-118-23-13-0019 LEGAL DESC CRYSTAL BAY BUSINESS CENTER : LOT 3 BLOCK 2 PERMIT TYPE FIRE SYSTEMS PROPERTY TYPE COMMERCIAL-BUSINESS CONSTRUCTION TYPE SPRINKLER SYSTEM-IN BUILDING NOTE: INSPECTIONS ARE DONE BY FIRE MARSHALL,JAMES VAN EYLL. PLEASE CALL JAMES VAN EYLL DIRECTLY AT:(952)473-9701 TO SET UP AN INSPECTION. ENTER THE VALUTATION 3879 APPLICANT FIRE SPRINKLER-COMMERCIAL 50.00 WELLINGTON SECURITY STATE SURCHARGE VAL OTHER 1.94 4 E. DIAMOND LAKE RD. MINNEAPOLIS,MN 55419 TOTAL 51.94 (612)822-4094 PAID WITH CC# 2324 Minnesota State License#: TS 00657 OWNER Orono Mini Storage LLC 6851 FLYING CLOUD DR SUITE A EDEN PRAIRIE,MN 55344- AGREEMENT AND SWORN STATEMENT The work for which this permit is issued shall be performed according to the approved plans and specifications,applicable City approvals,and the State Building Code. This permit is for only the work described and does not grant permission for additional or related work which requires separate permits. All provisions of laws and ordinances governing this type of work shall be compied with whether or not specified herein.This permit will expire and become null and void if construction authorized is not commenced within 180 days of the date of issuance,or if construction is suspended for a period of 180 days at any time after work has commenced. The applicant is responsible for assuring all required inspections are requested in conformance with the State Building Code.This permit may be revoked at any time for due cause. Applicant Permitee Signature Date Issued By Wature Date SEPARATE PERMITS REQUIRED FOR WORK OTHER THAN DESCRIBED A13OVE. i City of Orono p otttY P.U.Box 66 beta Received Partnittt m3-0 '77+4 f 2750 Kelley Parkway Crystal B my,MN 55323 AmovM 3 � (952)249.4600 AW-ed By: �� ❑CixugePlan Review ��kEs H oar en : A rw CITE'OF ORONO-FIRE ALARM OR KITCHEN EXTINGUISHER/GENERAL PERMIT (All permits mwt be approved byihe Mire lianhali edd/or 84ffding Onlcial) 1. All fire alarm systems,voluntary or required by Minnesota State Building Code(MU13C}or Minnesota State Fire Code(MUFC)shall be installed and maintained as per National Fire Protection Association(NEPA)72 and 72E, 1996 edition,National Electrical Code and manufacturers requirements, 2. Permits are required€or all fire alarm system installations. Permits can be obtained from the City of Orono-Building Official A 2750 Kelly Parkway Orono,MN or via phone(952)249-4640. Permits are also available online at:wj)2,ci.oronoajjn.us 3. Two sets of plans and specificati on sheets shall be submitted to the Orono Fire Marshal for approval at beast 7 working days before,start of installation and shall Include: a. Specification data sheets on all components of system. b. Floor plans indicating locations of devices,fire alarm control panel,sub-panels,transponders, enunciator,interconnecting wiring and zoning. c. Power connections Including source and branch circuit data. d. Type of back up power system. e. Fire alarm control panel shall be compatible with all devices, f. All components of the system shall be UL or j M listed for their applications, Smoke detectors shall be listed for commercial/Industrial use. 4. All systems shall be addressable.Smoke detectors shall be photo-electric.No combination burglar/flre alarm systems are allowed unless approved by the Orono Fire Mammal, 5. Power supply for the system sball Include battery back-up with a VL listed fire alarm panel. Alarm verification is required for all systems using smoke detectors. 6. The alarm system shall be audible above the ambient noise level in all areas of the building. Audio/visual signaling devices are required. 7. When central station notification Is required or provided it must be through a UL or FM listed communicator or control panel. 8. If a smoke detecting system installed in the tenant space of a building is directly connected to the building fire alarm panel,then a. A zone on the alarm panel must Identify the tenant space or zone of the building that the system is located(i.e.,second floor,west wing). b. A visual annunciation light shall be Installed on the corridor side of the main door of the tenants space and activate when the detection system in the tenants space activates. 9. The system shall be tested in the presence of the Orono Fire Marshal for final approval. Appointments can be made by calling the Fire Marshall at(952)473-9701, 24-bourn notice is requested. The test will include: a. Random testing of system devices. b. Random testing for system trouble and ground fault trouble. c. Correct operation of back-up power system. i r. s FIRE ALARM OR JaTCMN EMTIN UISHER PERNIITS Please Check One: ❑ New ® Addition ❑ Remodel ❑ Replace Job Site./Owner lnfomafti Site Address: Metro RV and Mini Stnmqe 2725 West Wa zata Blvd Owner: Pat McCann Mailing Address: 2725 West Wayzata Blvd City: ()=a Zip: 55356 Home Phone: -(612)916-5656 Alternate Phone: Contractor/Applica►trifcinafion: Contractor/App.: Wellington Security Systems Contact Person: Amanda Nelson Address: 4 East Diamond Lake Road State License#: TStB57 City: Minnepolis Zip: MN Expiration Date: Phone: (612)822-4094 Alternate Phone: TYPES OF.FIRE:PFAMUS; Commercial—Fire Alarm ❑ Commercial—Fire Extlnauisher Fire stems Pemtit Fite Swtetw NmIt * * *Contract Price:s 3879.00 *Contract Price:S__, ❑ Residential—Eire Alarm FkeSYsftm9Pe=h A Contract Price:$ q Note:Peiiaie_oalail S'°'1''rtli UBGgIIi6Ti+ i�le=rsu m3lisgiE,iid'ai�e Ixail vosSTttlie I herby apply for a Fire A lann/Extingulsher Permit and I acknowledge that the information above is complete and accurate;that the work will be In conformance with the Ordinances and Codes required by Minnesota State Building Code(MUBC)or Minnesota State Fire Code(MUFC)shall be installed and maintained as per National Fire Protection Association (NFPA) 72 and nE, 1996 edition, National Electrical Code and manufacturers requirements;that I understand this is not a permit and work is not to start without a permit; and that the work will be in accordance with the approved plan. it li IRE EXTINGUISHER PLAN N 0 15 3R 60 C 2- __ IS 11 10 4 6fr :a 52 0 51 0 39 3$ .637 -- — — -- EG ND �tt HEAT DETECTORMAY1 ANNUNCIATOR �� _ 0 55 !0 53 0;50 040 036 , M FIRE ALARM PANEL - Ur'1 . - FIRE EXTINGUISHER ... 0' ` 64' ---.._;_._._...._:o rJi}: . o�¢$...—41 . .• . . 03,5 J —1— ® eUNC I� ® Ijm. 7 - ot3 o82 o M - -048-- o43" 034 14 — — —_..�� - -� — -0 7 ^!� - 72— — 71IO _ 69 — X6871 !� �3p 24 19 79 Q 47� o44 . .fl. 0$3 9''9 231 ,26 ! 78 -e- — — �- — -0 060...- 0 570 0 45' 'Ig31'_-_ ( ....... 80 81 82 83 84 - - - �4� 12g _� _d59 Ir. 32 d 21 20 o f. 1. �' 27 22; a _ Li X 141 �� L n FWC-FSLC-SMK, FWC-FSLC-SMKALG, N & FWC-FSLC-HEAT, FWC-FSLC-SMK6B 333 Bayvlew Avenue & FWC-FSLC-SMK4B Amityville,New York 11701 For Sales and Repairs,(600)845-9446 DATA SHEET For Technical Service,(800)845-9440 Pubsmy tm&d m NA8EA4 "bon Nast ®NAPCO 2010 WI1928 09/10 ORDERING INFORMATION FWC-FSLC-SMK: Addressable SLC Photoelectric AGENCY LISTINGS Smoke Detector UL268: Smoke Detectors for Fire Alarm Signaling Sys- FWC-FSLC-SMKALG: Replacement head for the FWC- tems(FWC-FSLC-SMK, FWC-FSLC-SMK6B & FWC- FSLC-DUCT Photoelectric Analog Duct Detector (see FSLC-SMK4B) W1 1711). UL26BA: Smoke Detectors for Duct Application(FWC- FWC-FSLC-HEAT: Addressable SLC Heat Detector FSLC-SMKALG replacement head for the FWC-FSLC- 135°F DUCT) FWC-FSLC-SMK68: 6" Analog Smoke Detector (base UL521: Heat Detectors for Fire Protective Signaling Sys- only), tems(FWC-FSLC-HEAT) FWC-FSLC-SMK4B: FWC-FSLC-SMK6B - 6" Analog NFPA 72 National Fire Alarm Code Smoke Detector(base only). CSFM: California State Fire Marshall (Pending) Note: These sensors are compatible exclusively with fire FM Approval: (Pending) alarm control panels that utilize Napco's protocol, DCP. NYCFD: NYC Fire Department(Pending) For installation instructions,see Wl1709. SPECIFICATIONS CATEGORY PWC-FSLC-SMK TVC-FSLC-8MKALC, FW'C-MLC-HTuA..3' FWC-FSLC-$KK0 IWC-FSLC-6M Absalnte Maximum Applied Vohage 39.3 VDC 41,0 VDC: 41A VDC 41.0 VDC 41,0 VDC: Qperatvt vciuw gig- 22.9-39-5VDC244 40 7 VDC 24 40.7 VDC 24 44.7 VDC 24 40.7 VDC srnstdvity Raryie SEE CHART BFLOW SEE CHART MOW 37,Z°C 45.5°C N/A N/A (135wV? 1 St1 0 Current con9umpw� 390µA Typical 3'90µA Typical 330 't teal ( 7 Nounal"N a 800kN�kCs bmm 540µA Maxinitm7 500}h Maxumrm Ni.A N/A C=cert Consuum�. N/_A (S tiC_)�ihen Polled 2mA �. 2mA N/A Alarm curt-em(S-sc) ($er B—) (See Base) (See Aatse) 8mA(£ypicxo aMA('CAi Q Remote LRD C:urrmt (Sce Base) (Sae Base) (see&dee) 8mA Tical) 8mA(T mil) Device 7ypc Code 88 Hca 88 Hex 98 Hex NIA N/A -10"C-50.c .10*C-50"C -10*C-50T -1060--WC.: .10aC^-5011C Operating Temperature (14"F-122--) 140P--1220F 4"F-122"F1 (14"F--122"1') 114"F- 122 0°C--37.8"C ) '-PAM 0•C-CC 0"C'-47"C 0°C 47°C UL lixtcd truipet>atare t32"F^-L00"Fr) (32"F'-Wil° 2"P-115°I' C32°F I iil ) (3z°?z l IST storage Temperature -20"C-WC -20°C.,.(WC -2D C-60"C C C 51) 4111F-.1 (-4-17 10 -4"P•-1 (-4"F—140" ("4°p 1400P) Text „ * + N/A N t1 Dimcnsuwe 375176"nXl-1/2'H 3.15/IG"AXi-7/2li 3.15/1tS-D7C1.9/16'H S4/9"DX15/3M 4.1/8"DX5/14"H Rrvircmtvent indoor Use 01iiy Indoor Use Only indoor Use Ortlp indoor Use Only In&or Use Only VowerIndicator Dual Power Dual LM Dual 117D l?nal LED See Sensor Sec Sensor Addreu 5cuing r . N A *=Sec Control Panel For proper address setting and tee-trig procc&m. SENSITIVITY RANGFE'; VEI.00ITY f t7i FOG'C-FSLC:-SbflChLG(°/a/ft) FWC-FSLC-SMK(/a/ft) BOX MOUNTING 8S--3.57 0.5-3,80 BASE 3%0 ,t"_a 4 2000 .88 -2.81 0.5 k 2.74 4000 .8$ 2 5E 0. -2 dA F1WC-FSLC-5MU13 YES YES YES FWC-FSLC-SMK4B YES NO NO