Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2001 - P03577 - mechanical
I PERMIT CITY OF ORONO 2750 Kelley Parkway - PO Box 66 Permit Number: P03577 Crystal Bay, Minnesota 55323 Permit Type: Mechanical Permits (952) 249-4600 Date Issued: 3/6/2001 SITE ADDRESS: 2760 White Oak Cir LONG LAKE,MN 55356 PID: 04-117-23-42-0018 DESCRIPTION: Proposed Use: Residential Permit Class: General Permit Type: Mechanical Permits Permit Sub-type(s): Heating Systems DETAILS: Approved per resolution#: Separate permits required: NOTICES/REMARKS: FEE SUMMARY: Permit Fee: $ 65.15 Valuation: $ 5,212.00 State Surcharge Fee: $ 2.61 Misc. Fee: $ 1.50 TOTAL FEE: $ 69.26 APPLICANT: DITTER INC&DITTER PROPERTIES OWNER: J L JR&K C SHANNON 820 TOWER DR 2760 WHITE OAK CIR HAMEL,MN 55340 LONG LAKE MN 55356 THE UNDERSIGNED HEREBY REQUESTS PERMISSION TO MAKE THE REAL IMPROVEMENTS SPECIFIED AND AGREES TO DO ALL WORK IN STRICT COMPLIANCE WITH ALL CITY OF ORONO ORDINANCES AND STATE OF MINNESOTA BUILDING CODE REQUIREMENTS. \A IL - IN ,62/43 APPLICANT' PI ERMITEB SIGNATURE ISSUED BY SIGNATURE Copies: City,Applicant,Assessor,Finance Page 1 (19, 2.< CITY OF ORONO APPLICATION FOR MECHANICAL PERMIT Box 66 (2750 Kelley Parkway) Crystal Bay, MN 55323 GENERAL INFORMATION 1° � 1. You may apply for mechanical permits by mail or in person at the City offices. Applications will be reviewed and a permit will be issued within 2 working days. 2. Permit cards will be sent by return mail after a review is completed. PERMITS ARE NOT VALID UNTIL YOU RECEIVE A PERMIT. WORK MUST NOT BEGIN UNTIL THE PERMIT CARD IS POSTED ON THE JOB SITE. 3. Mechanical Designs - Complete calculations, details and specifications are required for each heating, ventilation, humidification-dehumidification, and air conditioning installation including heat loss/heat gain calculation, design temperatures, equipment ratings and identification as to type, manufacturer and model. Data shall be presented on form provided. Identification of and specifications for water heating equipment shall also be provided. 4. When any new construction or remodeling is involved, a separate building permit must be obtained. 5. All work must be done in accordance with the Uniform Mechanical Code/State Building Code requirements. 6. All work must be inspected(rough-in and final). Call 249-4600. 24-hour notice required. 7. House Heating Test Record must be submitted before final. Instructions Complete all items on this application. Compute the permit fee. Sign and date the certification. INCOMPLETE APPLICATIONS WILL NOT BE PROCESSED. If you have questions, call 249-4600. Please check one: New / Addition Repair Replace Residential Commercial JOB SITE: ?-7( 6 W1(14( Oak Zip: �' Owner's Name: John n I� '€ fiit m Telephone Number: QS L1 4?(o (L75 Mailing Address: 2.7(o"D Lvh oma, 11 trc e_ City: a�� Wei._ Zip: 33331/ Contractor's Name: --70N LI7� 'Q �� ..�c . Tele, � ne Number: Mailing Address: (71 U A, ��i �'�. City: Zip: 51S-3/-0 tzo SYSTEM DESCRIPTION — Prc,v t d L 14'1 blow fr1 4-I/1°-:)I9 �iYY� ctt&c I' `r HEATING SYSTEMS Quantity: Make: Model: • Fuel: Flue Size: Input BTUs: Output BTUs: CFM: COOLING SYSTEMS Quantity: Make: Model: Tons: H. Power FIREPLACES Gas factory fireplace Wood burning factory fireplace with flue Wood Stove Wood stove with flue Brand Name Model No. VENTILATION No. Kitchen Exhaust ducted recirculating cfm No. Bath Exhaust (must be ducted outside) cfm No. Other Fans: Locations cfm FUEL STORAGE (MUST BE APPROVED BY FIRE MARSHAL) Installation Removal Fuel oil: gallons underground inside outside LP Gas: gallons Other Gas opening PERMIT FEE CALCULATION 1. 1.25% of Contract Price* or Minimum Fee ($35.00) �Z( Z . x .0125 $ < <� (contract price) 2. State Surcharge. ** Add the State Building Code Division Surcharge to each permit. x .0005 $ Z.•( (V or $.50, whichever is greater (contract price) 3. Postage and Handling (Only mail-in applications) $ 1.50 4. TOTAL PERMIT FEE (Add lines 1-3 above) $ cog. 25' * CONTRACT PRICE or JOB COST means the actual or estimated dollar amount charged for the permitted work including materials, labor,profit, and other fixed costs. It is the amount to be charged to the customer for the work done. If any material, equipment, labor, or installation are furnished by the owner, tenant or any other party the reasonable market value of such items must be added to the estimated cost or contract price for permit fee purposes. In the event that there is a dispute on the amount of the job cost,the City may request the submission of a signed copy of the actual contract. ** The STATE SURCHARGE is .0005 of the contract price under$1,000,000 or $.50 -whichever is greater. For valuations over$1,000,000 call the Department of Inspectional Services for the price. The undersigned hereby applies to the City for issuance of a Mechanical Permit, agrees to do all work in strict accordance with the ordinances of the City and the regulations of the Minnesota State Building Code, and certifies that all statements made on this application are complete, true and correct. Applicant's Signature: -322)0( i nature: 614 Date: Approved By: Date: STEPHENSON/SHANNON HVAC LOAD ANALYSIS for Shannon 2760 White Oak Cir Orono, MN • `� .r��; .� . 'iii• ,�. ResiDENTIAL HVAC Lona Prepared By: Doug Bjork Ditter Inc., Cooling and Heating 820 Tower Drive Medina, MN. 55340 (612)478-9558 02-27-2001 ------ - - -------- RH VAC-Residential&Light Commercial HVAC Loads Program • Elite Software Development,Inc. Ditter,Inc. Stephenson/Shannon Hamel,MN 55340-9691 02-27-2001 Page 2 Total uilding Summary Loads Component Area Sen. Lat. Sen. Total Description Quan Loss Gain Gain Gain 3E Window Double Pane Low Emit TIM Frame 199 7,305 0 9,305 9,305 8M Glass Door Double Clear Glass Wood Frame 105 5,322 0 5,775 5,775 12H Wall R-19 + 1/2" Gypsum Board(R-0.5) 817 4,510 0 1,158 1,158 16H Ceiling R-38 Insulation 425 1,017 0 486 486 22D Slab on Grade 2" Edge Insulation(R-11) 59 1,140 0 0 0 Subtotals for structure: 1,605 19,294 0 16,724 16,724 Active People: 0 0 0 0 0 Inactive People: 0 0 0 0 0 Appliances: 0 0 0 0 0 Lighting: 0 0 0 Ductwork: 0 0 0 0 0 Infiltration: Winter CFM: 53.8, Summer CFM: 26.9 304 5,286 639 575 1,214 Ventilation: Winter CFM: 0.0, Summer CFM: 0.0 0 0 0 0 0 Sensible Gain Total: 17,— 299 Temperature Swing Multiplier: X1.00 B ----- --- ----- --uiing Load Totals: 24,580 639 17,299 17,938 Check Figures Total Building Supply CFM: 810 CFM per square foot: 0.953 Square feet of room area: 850 Square feet per ton: 454.015 ------ ---- ----- Building Loads Total heating required with outside air: 24,580 Btuh 24.580 MBH Total sensible gain: 17,299 Btuh 96 % Total latent gain: 639 Btuh 4 % Total cooling required with outside air: 17,938 Btuh 1.495 Tons (based on sensible + latent) 1.872 Tons (based on 77% sensible capacity) Notes ---------- Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. J Tuvvsdav, February 27.2001 DATE //TIME CITY OF ORONO CALLED IN I C/ Ud INSPECTION fs4.9TI E SCHEDULED �f —o b- 0' 0 PERMIT NO. K 0251 7 COMPLETED ADDRESS .2-7 co © co -kbt ` OWNER .1,--C-/Izat-v).,y-a51-2 CONTR. `�`C TELEPHONE NO. 70 3 Lf 7 0 l s-g DESCRIPTION W 01 FOOTING 1 ECHANICAL RI 18 EXCAV/GRADING/FILLING cc cc 02 FRAMING 13 MECHANICAL FINAL 19 LAKESHORE/WETLANDS 03 INSULATION 24/25 WOOD BURNER/FIREPLACE 34 TREE REMOVAL 04 WALL BD. 12 WATER HOOK-UP 17 SITE INSPECTION Q 05 FINAL 14 SEWER HOOK-UP 06 PROGRESS • 07 DEMO-SITE 27 SEPTIC MAINT. 21 COMPLAINT ✓• 07 DEMO-FINAL 15 SEPTIC INSTALL. 22 FOLLOW-UP = 09 PLUMBING RI 23 SEPTIC FINAL 35 HARD COVER REMOVAL J 10 PLUMBING FINAL 36 FOUNDATION/REMOVAL Q OWNER/CONTRACTOR TO MEET YOU:_YES_NO o COMMENTS: W a c 0 cc 0 ti W W CC j ✓VORK SATISFACTORY:PROCEED ❑ PROJECT COMPLETE CC E7 CORRECT WORK&PROCEED C; ISSUE CERTIFICATE OF OCCUPANCY • LI CORRECT WORK,CALL FOR REINSPECTION TEMPORARY OU BEFORE COVERING PERMANENT ❑CORRECT UNSAFE CONDITION WITHIN HOURS. PHOTO TAKEN INSPECTOR WILL RETURN ElSTOP ORDER POSTED.CALL INSPECTOR CITATION ISSUED ❑ INSPECTION REQUIRED.CALL TO ARRANGE ACCESS. Call for the next inspection 24 hours in advance. 249-4600 Owner/Contrac or on site: Inspector C White Copy/Inspector's File Canary Copy/Site Notice