Loading...
HomeMy WebLinkAboutSeptic System Inspections On the North Shore of Lake Minnetonka ON-SITE SEWAGE TREATMENT � � INSPECTION REPORT CITY POST OFFICE BOX 66 OF 1335 S. Brown Rd. ORONO Crystal Bay, MN 55323 473-7357 OWNER K.Uy �C�smuss&N ADDRESS c)-100W(-RTE C)4 C_\RCU. PHONE ! PERMIT NO'S. $a 86 DATES 4.5- t 2" Th' City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below: ISI T i Meets or exceeds current city standards in all respects relating to design, construction, and location. Appears to be operating properly. ❑ 2 Does not meet current city standards in some respects relating to design, construction, or location. Appears to be operating properly. ❑ 3 Does not meet current city standards in many respects relating to design, construction, or location. Appears to be operating adequately. ❑ 4 Does not meet current city standards of design, construction or location, is being overused, or is failing to properly treat and dispose of the current input and is therefore endangering a water supply, is a source of pollution to surface or groundwaters, is creating a safety hazard,or is otherwise creating a public nuisance. Please contact the inspector to discuss requirements for repairs to your system. Soil testing may be re- quired. In all cases a design and site plan must be submitted for review. Your contractor must obtain a permit before work is started. WORK REQUIRED: LISeptic tanks must be pumped within 48 hours. ❑ Drainfield must be repaired or replaced within 90 days. ❑ Inspection riser (4"diam. pipe) must be installed in each tank. ❑ Tank inspection indicates maintenance pumpout is needed as soon as possible. City ordinance requires that tanks be pumped out every three years. SITE CHARACTERISTICS: Limiting Site Factors Potential for System Failure Site Capabilities for ❑Slope (depends on soil types,water Future Expansion Soil table,and system condition) 01 Adequate ®High water table ® Low 0 Fair ❑Lot size (Medium 0 Poor ❑Lake,wetland,or stream 0 High ❑ Inadequate 0 Drainage 0 System is causing visible surface discharge. COMMENTS: Date of Inspection eptic System Inspector This report must be kept on the premises with system location and pumping records. WHITE COPY/ Inspector's File GOLD COPY/Homeowner On the North Shore of Lake Minnetonka ON-SITE SEWAGE TREATMENT CITY INSPECTION REPORT OF POST OFFICE BOX 66 ORONO 1335 S. Brown Rd. Crystal Bay, MN 55323 473-7357 OWNER JOea4AP-- ADDRESS %� U `YI t& �,r "cJLai� Lage PERMIT NO.'S. ���& DATES g�1 CONTRACTORSW P/61' City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The on-site sewage treatment system at the above has been inspected and appears to fall into the category checked below. —� 1 Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating (This is existing system 0 new construction) Y� properly. U 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, located, and constructed generally in accordance with previous codes.System appears to be functioning properly;no major upgrading of the system is required at this time. 0 3 Does not meet current City standards in many respects relating to design,construction,or location.Appears to be operating adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at this time. U 4 System may or may not meet current City standards for design,construction or location, but is failing to properly treat and dispose of the current input, and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is creating a safety hazard,or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/ replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan must be submitted for review.Your contractor must obtain a permit before work is started. SYSTEM CONDITION ( m Checked items may require your action) Tank inspection indicates: Inspection pipe is located directly over tank baffle.(Does not ❑ Pumpout not needed at this time. ve accurate measurement of solids accumulation.) If tanks ❑ Solids accumulation in tanks indicates they should be pump- have not been pumped out within the last three years,they ed out this year to help prevent future problems, should be pumped out now. ❑ Solids accumulation in tanks is at a critical level. Tanks D ainfi d inspection indicates: should be pumped out as soon as possible. Dainfield is dry,no surfacing evident. ❑ System is discharging to surface. Tanks must be pumped 0 me evidence of surfacing,not critical yet. within 48 hours to eliminate surface discharge. 0 Drainfield is saturated and visibly discharging untreated ❑ Inspection risers missing—tanks could not be inspected. effluent to the surface. This condition may require replace- Inspection risers (4" dia. pipe)must be installed in each tank ment or additions to drainfield. Contact the City Inspector at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days. the last three years,they should be pumped out now. 0 Drainfield extent and condition unknown. SITE CHARACTERISTICS: Limiting Site Factors Potential for System Failure Site Capabilities for ❑ Slope (depends on soil types,water Futur�l Expansion ❑ Soil table d system condition) /`fC'�v'Adequate ❑ High water table ow 0 Fair ❑ Lot size 0 Medium 0 Poor ❑ Lake,wetland,or stream 0 High 0 Inadequate ❑ Drainage 0 System is causing visible surface discharge. �y COMMENTS: 0 Al A .� V•)., `7, ./A ha .!...L...1.141-1 S 6/Klee �00. . i I / Lai cif Fl.f, pi2_13 avl LP _eA c -3 p (0-1(0 -6B /,'"AA. /44 . Date of Inspection '•. Septic System.Lr.ector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with system location and pumping records. WHITE COPY/Inspector's File GOLD COPY/Homeowner On the North Shore of Lake Minnetonka ON-SITE SEWAGE TREATMENT CITY INSPECTION REPORT OF POST OFFICE BOX 66 ORONO 1335 S. Brown Rd. Crystal Bay, MN 55323 473-7357 OWNER K517)11P7, ADDRESS c%27a3 i,h4 064 ark. 2-47-7g' C + PERMIT NO.'S. DATES CONTRACTORS City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is IA- an existing system 0 new construction) S1 Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating properly. EJ2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, located, and constructed generally in accordance with previous codes.System appears to be functioning properly;no major upgrading of the system is required at this time. El3 Does not meet current City standards in many respects relating to design,construction,or location.Appears to be operating adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at this time. 4 System may or may not meet current City standards for design,construction or location, but is failing to properly treat and dispose of the current input, and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is creating a safety hazard,or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/ replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan must be submitted for review.Your contractor must obtain a permit before work is started. SYSTEM CONDITION ( L2J Checked items may require your action) Tank inspection indicates: 0 Inspection pipe is located directly over tank baffle.(Does not ❑ Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks ❑ Solids accumulation in tanks indicates they should be pump- have not been pumped out within the last three years,they ed out this year to help prevent future problems. should be pumped out now. ❑ Solids accumulation in tanks is at a critical level. Tanks Drainfield inspection indicates: should be pumped out as soon as possible. Drainfield is dry,no surfacing evident. ❑ System is discharging to surface. Tanks must be pumped 0 Some evidence of surfacing,not critical yet. within 48 hours to eliminate surface discharge. 0 Drainfield is saturated and visibly discharging untreated *4 Inspection risers missing—tanks could not be inspected, effluent to the surface. This condition may require replace- Inspection risers (4" dia. pipe)must be installed in each tank ment or additions to drainfield. Contact the City Inspector at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days. the last three years,they s1113101T6METiimped out now. 0 Drainfield extent and condition unknown. SITE CHARACTERISTICS: Limiting Site Factors Potential for System Failure Site Capabilities for O Slope (depends on soil types,water Future Expansion O Soil table,and system condition) dequate O High water table 0 Low air ❑ Lot size 91-Medium Poor ❑ Lake,wetland,or stream 0 High 0 Inadequate ❑ Drainage 0 System is causing visible s rface ischa ge. f COMMENTS: 1 Y Y'p T L Y►� 2 a �/I�IJI� �7�1I1f�S ,L�✓�'. ID�t?Y1 'n Asn ce ‘---00 aid sIjv/cJ per/ d a4-- Aek p e✓enj- cvivre- pr-cVem, Date of Inspection eptic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with system location and pumping records. WHITE COPY/Inspector's File GOLD COPY/Homeowner CITY OF ORONO - Municipal Offices O O Post Office Box 66 �_ to Crystal Bay, MN 55323-0066 t ON-SITE SEWAGE TREATMENT ,' 6 ' INSPECTION REPORT .4 r � P 9kESHO4 Owner: 70' / Jark e Address: 2-130 I41! Oai (may, Permit #'s: ,-h.."-) Dates: 10:1 —13 Contractors: TThV7./OAj,,.SW01^-..., City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. r , (This is [ ] an existing system new Go non) SYSTEM CONFORMITY (1-3): 1 6) "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristichas or [ ] has not been identified at this time. If the limiting soil characteristic has not been identi ted, this classification may be subject to revision.) TANK CONDITION (5-10): Tsnl� inspection indicates: ( 5/ Pumpout not needed at this time. �S Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next punpout. If tanks have not been pumped out within the last three years, they should be pumped out now. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been pupped out within the last three years, they should be pumped out now. DRAINFIELD CONDITION (11-14): 1, Dretfield inspection indicates: (1V Drainfield is dry, no surfacing evident. `12 Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City inspector immediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (slope.setbacks,etc.): i444- 7�PJ POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): Lp!"-J COMMENTS: to:WM dfd4 Iv, %/17.7s�---- p Date of Inspection ec Sys em Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the system location and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner lti CITY OF ORONO O O Municipal Offices t Post Office Box 66 Crystal Bay, MN 5r-323-0066 ON—SITE SEWAGE TREATMENT it, .�) INSPECTION REPORT ost 1kESHOl' Owner: ICO'/ ,GLS171tss \ Address: e? fi. Ad— alam. CK- . Permit #'s: - Dates: -17-7g Contractors: , %tci n4 Piej. City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is A.an existing system [ ] new construction) SYSTEM CONFORMITY (1-3): 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging 4 any pollutants into ground or surface waters. "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic (has or [ ] has not been identified at this time. If the limiting soil characteristic has not been identi ied, this classification may be subject to revision.) TANK CONDITION (5-10): Jo Tank inspection indicates: 5 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped out now. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been pumped out within the last three years, they should be pumped out now. DRAINFIELD CONDITION (11-14): 11 D nfield inspection indicates: �1]� Drainfield is dry, no surfacing evident. '1122 Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (slope,setbacks,etc.): /_ L i- liik POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): J i COMMENTS E, ,/ .� L' ' '!__° 14/���r I A, I t ' I II /./aa�■at 1�I I, !i,.i-1 _- t O i�IP��T� i d . �• N.'QAC• `.111x2 —/• AillL•jf + BFIPM [Iltir-.G'/�Tii4g1 / t. Ar V7,J .-r 'C , e. 'r ��P /R/ - 1 e n OI / 371- _ !• /Irl.' I11C• ill Y� )1`2ji7t �P J'Z°r 1 Date of Inspection Se• is System Inspector k,, Oh-e,y{ e; Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the system location and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner ,4O o o�,� 'i'� r ,, ; CITY of ORONO v\*$, i'.' ,� A yti Municipal Offices .t iG Street Address: Mailing Address: `qkES 2150 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323.0066 Owner: ��v ,J�i �09Address:2700 White Oak Cir. Permit #'s:5587 Dates:10/7/93 Contractors:Jerry Johnson (This is [ ] an existing system [ ] new construction) STEM COMPLIANCE (1-3) : 1 �1 Code System: Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. 2 Compliant System: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance with previous codes and is functioning properly. 3 Non-Compliant System: System may or may not meet current City standards for design, construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level. i (The saturated soil level f? has or [ ] has not been identified at this time. If the saturated soil level has not been identified, this classification is subject to revision.) TANK CONDITION (5-9) : 9 5 Pumpout not needed at this time 6 Solids accumulation in tanks indicates they should be pumped out this year. 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out within three years, they should be pumped out and risers installed now. Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks have not been pumped out within three years, they should be pumped of now. (During the last septic tank Maintenance Pumpout the tanks [ ] were or [ j were not confirmed to be watertight by the licensed pumping contractor. If the tanks were not confirmed to be watertight, this classification is subject to revision. ) INFIELD CONDITION (11-14) : 11 Drainfield is dry, no surfacing evident. OSome evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc. ) : low COMMENTS: r, , .------// Date of Inspection Sep is System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicates the operation of the system under current conditions. Telephone (612) 473-7357 • FAX 473-0510 .0,) 0,4,. O O ; ;=, CITYof ORONO � 0. '..! ty\ ,r,, _ ti \,�► ,a , Municipal Offices 9vi10¢,� Street Address: Mailing Address: 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 Owner: in. it — Address: 2700 White Oak Cir. Permit #'s: 5587 Dates: 10/7/93 Contractors: Jerry Johnson (This is CX/J an existing system ( ] new construction) . SYSTEM COMPLIANCE (1-3) : 1 0 Code System: Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. 2 Compliant System: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance with previous codes and is functioning properly. 3 Non-Compliant System: System may or may not meet current City standards for design, construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level. (The saturated soil level is (/....1 or is not [ ] identified under this septic system. If the saturated soil level is not identified, this classification is subject to revision.) TANK CONDITION (5-9) : 9 5 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year. 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out within three years, they should be pumped out and risers installed now. / 9/ Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks l� have not been pumped out within three years, they should be pumped out now. 10 One or more tanks are cesspools, which means the septic system is non-compliant. (The tanks are [ ] or are not [ ] water tight or the condition is [y unknown. If the tanks are not confirmed to be watertight, this classification is subject to revision.) DRAINFIELD CONDITION (11-14) : 11 • 11 Drainfield is dry, no surfacing evident. 12 Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : low COMMENTS: ijq &_ ate of Inspection s ep ' r System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existingsystem will continue to function properly, but indicates the operation of the system under current conditions. Telephone(612)249-4600 • Fax(612)249-4616 0 4 O �� O CITY of ORONO A '0?- ,.it.-__ At ti Municipal Offices \ v4 t r1\ini' h G~ Street Address: MailingAddress: '�kEggO 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 Owner: MGC y Tho tm?5 0 Address: 3700 W k,-VQ Oc k C",cck City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFORMITY (1-3): ` C. "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono Municipal Code but does meet the three foot separation requirement,and which is not failing or an imminent threat to public health or safety. 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may or may not meet all the location,design,or construction standards ofthe current Orono Municipal Code and which is failing for any reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. TANK CONDITION(5-10): ( Tank inspection indicates: 5 Pumpout not needed at this time. UTank must be pumped out this year (city code requires tanks to be pumped out every 3 years. Tank was last pumped \—7-S 7 )_ 7 Solids accumulation in tanks is at a critical a critical level. Tanks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. 9 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank at next pumpout If tanks have not been pumped out within the last three years,they shouh#be puifiq-aTifft now. 10 Inspection pipe is located directly over tank baffle(does not give accurate measurement of solids accumulation). If tanks have not been pumped out within the last three years,they should be pumped out now. DRAINFIELD CONDITION(11-14): \1 CIDDrainfield is dry,no surfacing evident. 12 Some evidence of surfacing,not critical yet • 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately.Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. COMMENTS: Quo. A-0.4,5 nxA- SVC".r-5 , Sy5-1-e,, IOCOK 10 - C.-O I Date of Inspection Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. so!° ; ;:• .f ` CITY of ORONO 1 ,��, : ! . Municipal Offices r1.1 •-•i 1I1itY., 1v 1 �'� G '� 4/ Street Address: Mailing Address: \ESH�� 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 To Current Owner: . Address: c:"1-7°0 \ C`11(- C;Tc (. City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFORMITY (1-3): Q)"CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and which is not failing or an imminent threat to public health or safety. 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. TANK CONDITION(5-7): Tank inspection indicates: CDPumpout not needed at this time. 6 Septic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years. Tank was last pumped ) '-7 -`k7 ). Make sure septic tanks are pumped through manhole and not through white inspection pipes. This allows for the proper cleaning. Keep water softner and iron filter discharge out of septic system. 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4" dia.pipe)must be installed in each tank. If tanks have not been pumped out within the last three years,they should be pumped out now. DRAINFIELD CONDITION(8-10): ?3 Drainfield is dry,no surfacing evident. 9 Some evidence of surfacing,not critical yet. 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately.Repairs must be completed within 90 days. COMMENTS: lv•v \ 06\ S O- S�Q Date of Inspection Matt Bohemian - Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. Telephone(952)249-4600 • Fax(952) 249-4616 www.ci.orono.mn.us �O ,\\ , - `' CITY of ORONO �� ,� ? r , I 8Municipal Offices � 'I Street Address: Mailing Address: �IO¢� l �,xES !%" 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 To: The Current Owner of Address g"7L wh 1-C- O; , K G �f City Ordinance requires that onsite sewage treatment systems in Orono be inspected on a periodic basis. The onsite sewage treatment system at the above address has been inspected and the following is known about the system. A sketch of the known components of the system is available for most properties at the Orono City Hall. Imminent Public Health Threat Yes No If yes, please contact the Onsite Systems Manager at 952-249-4626 within 10 days of receipt of this notice. The septic system must be brought into compliance within 90 days. Failure to do so will result in referral to the City Attorney for legal action. System Identified as Non-Compliant Yes No If yes, system must be brought into compliance by: December 31,2007 December 31, 2010 Other Septic Tank(s) Pump out Needed Yes No The City recommends the septic tank(s) and/or lift tank be serviced and pumped out every three years. City records indicate the tank(s) were last pumped out on F- 10. O . The tank(s) should be cleaned through the manhole and not through the inspection pipes, this allows for proper cleaning. Comments: Inspect r `' Date of Inspection I 0 'r% 3 . p P Telephone(952)249-4600 • Fax(952)249-4616 www.ci.orono.mn.us