Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2007 - P11521 - mechanical
PERMIT CITY OF ORONO Permit Number: 2750 Kelley Parkway- PO Box 66 P11521 Crystal Bay, Minnesota 55323 Permit Type: Mechanical Permits (952) 249-4600 Date Issued: 10/2/2007 SITE ADDRESS: 2655 West Lafayette Rd Unit# Excelsior,MN 55331 PID: 21-117-23-24-0039 DESCRIPTION: Proposed Use: Residential Permit Class: General Permit Type: Mechanical Permits Permit Sub-type(s): Multiple Mechanical Items DETAILS: Approved per resolution#: Separate permits required: NOTICES/REMARKS: FEE SUMMARY: Permit Fee: $ 175.00 Valuation: $ 14,000.00 State Surcharge Fee: $ 7.00 Misc. Fee: $ 1.50 TOTAL FEE: $ 183.50 APPLICANT: Metro Air Inc. OWNER: Ronald&Esther Martens 16980 Welcome Ave SE 2655 West Lafayette Rd Prior Lake,MN 55372 Excelsior,MN 55331 THE UNDERSIGNED HEREBY REQUESTS PERMISSION TO MAKE THE REAL IMPROVEMENTS SPECIFIED AND AGREES TO DO ALL WORK IN STRICT COMPLIANCE WITH ALL CITY OF ORONO ORDINANCES AND STATE OF MINNESOTA BUILDING CODE REQUIREMENTS. (A,1/4- ig?tr— APPLICANT PERMITEE SIGNATURE UED BY SIGNATURE Copies: 1-File(Signatures Required), 1-Applicant, 1-Monthly Reports, 1-Assessing,(If Septic, 1-Septic) Page 1 f FOR CITY USE ONLY ' 4v\ City of Orono • P.O.Box 66 Date Received: Permit# _ �V O 27.50.Kelley Parkway 1-. Crystal Bay,MN 55323 Approved By: Amount$: 'L t'� (952)249-4600 CITY OF ORONO—MECHANICAL PERMIT (All Commercial permits must be approved by the Building Official or Inspector and/or Fire Marshall) GENERAL INFORMATION 1. You may apply for mechanical permits by mail or in person at the City offices. Applications will be reviewed and a permit will be issued within two working days. 2. Permit cards will be sent by return mail after a review is completed. PERMITS ARE NOT VALID UNTIL YOU RECEIVE A PERMIT. WORK MUST NOT BEGIN UNTIL THE PERMIT CARD IS POSTED ON THE JOB SITE. 3. Mechanical Designs-Complete calculations,details and specifications are required for each heating,ventilation,humidification-dehumidification,and air conditioning installation including heat loss/heat gain calculation,design temperatures,equipment ratings and identification as to type,manufacturer and model. Data shall be presented on form provided. 4. When any new construction or remodeling is involved,a separate building permit must be obtained. 5. All work must be done in accordance with the Uniform Mechanical Code/State Building Code requirements. 6. All work must be inspected(rough-in and final). Call(952)249-4600. (24-48 hour notice required) 7. House Heating Test Record must be submitted before final. TYPE OF PERMIT (Check All That Apply) Residential ❑Commercial(Approval Required) 14 New ❑Additional 0 Repairs ❑Replace Job Site/Owner Information: Site Address: 2 (.0 C i Lr1 \G y(C\-"k- c. Owned—e���► - <On ST_ Mailing Address: / D,c\_ N Cw�-�► �laS� City: G\- YwAin. M Zip: s gg, Home Phone: cls-a- Alternate Phone: Contractor Information: ff Contractor: r�, r` L Contact Person: "' t S v�Q- I Address: o c1�� C` otw,l{tiQ State Bond#: L C 6 4 3 City: 'Q e t J^ ok. Zip:$-S-3lxpiration Date: Ij- \. " Phone: cAC "�u1"�ia� Alternate Phone: eiCiAr n Insurance-Current: (O\ C q k& 1 r MECH ANICAL'kS STEMS:sE1NGINS'I ALLEn: .:: HEATING SYSTEMS Quantity: Make: ✓y 4hT Model: 6pw-Ob\-\ %. Fuel: N ' Flue Size: 3 r I P V Input BTUs: 1 Ob ,pV V Output BTUs: 1 CFM: o1��1O COOLING SYSTEMS Quantity: Make: !NJ 4 Model: 1 a..3A 01 \A Tons: H.Power FIREPLACES ® Gas Factory Fireplace ❑ Wood Burning Fireplace ❑ Wood Stove ❑ Wood Stove With Flue Brand Name: Model No.: VENTILATION Er No. L Kitchen Exhaust (p duct recirculating 300 cfm ONo. 4 Bath Exhaust(must have duct outside) 'v cfm No. Other Fans: Locations cfm FUEL STORAGE(MUST BE APPROVED BY FIRE MARSHALL) ❑ Installation 0 Removal Fuel Oil: gallons 0 Underground ❑Inside ❑Outside LP Gas: gallons Other: GAS LINE ONLY O Outdoor Grill 0 Other/List What&Where: 2 a,Bt SED OFF 0©25 � TA E' . ❑ Yes,this section applies The replacement of a Residential fixture or appliance that meets all three of the following requirements: 1. Does not require modification to electrical or gas service. 2. Has a total cost of$500.00 or less;excluding the cost of the fixture or appliance:and 3. Is improved,installed or replaced by the homeowner or licensed contractor. Skip next section,if this applies; Cost of Permit $ 15.00 State Surcharge $ .50 Mail-In Fee(If Applicable) $ 1.50 Total Permit Fee $ PERMIx E:EE:CALCULAI IONS) ."JOBS:OVER$500.00 If above does not apply;follow guidelines below: 1. CONTRACT PRICE *is 1.25%of contract price with a(Minimum Fee of$35.00) �y pop �� l x.0125$ (contract price) (minimum$35.00) 2. STATE SURCHARGE **Add the State Bldg Code Div. Surcharge(Minimum Fee of$.50) v1 �Vv x.0005 $ W� (contract price) (minimum S .50) 3. POSTAGE&HANDLING(Only on Mail-In Applications) $ 1.50 4. TOTAL PERMIT FEE(Add Lines 1-3 Above) $ • * CONTRACT PRICE or JOB COST means the actual or estimated dollar amount charged for the permitted work including materials,labor,profit,and other fixed costs. It is the amount to be charged to the customer for the work done. If any material,equipment, labor or installations are furnished by the owner,tenant or any other party,the reasonable market value of such items must be added to the estimated cost or contract price for permit fee purposes. In the event that there is a dispute on the amount of the job cost,the City may request the submission of a signed copy of the actual contract. • **The STATE SURCHARGE is.0005 of the Building Department at(952)249-4600 for the price. MEettAN10. ##RMI AFPLI(.JAI ION°AGREEMENT The undersigned hereby applies to the City for issuance of a Mechanical Permit, agrees to do all work in strict accordance with the ordinances of the City and the regulations of the State of Minnesota, and certifies that all statements made on this application are complete, true and correct. Applicant's Signature: Date: 1 J Reset Form 3 Martens Residence HVAC Load Calculations for Lee-Lyn Construction 729 Newton Ave SE Watertown, MN 55388 jOhnitt 111 'HVACRESIDENTIAL, HVAC LOADS Prepared By: Joe Storms Metro Air, Inc. 16980 Welcome Ave. S.E. Prior Lake, MN 55372 952-447-8124 Thursday, September 27, 2007 Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Metro Air Inc. Martens Residence I Prior Lake,MN 55372-3310 Page 2 Project Report General Project Information Project Title: Martens Residence Designed By: Autumn Design Project Date: Thursday, September 27, 2007 Client Name: Lee-Lyn Construction Client Address: 729 Newton Ave SE Client City: Watertown, MN 55388 Client Phone: 952-955-3388 Company Name: Metro Air, Inc. Company Representative: Joe Storms Company Address: 16980 Welcome Ave. S.E. Company City: Prior Lake, MN 55372 Company Phone: 952-447-8124 Company Fax: 952-447-8126 Company Website: www.metroairmn.com Design Data Reference City: Prior Lake, Minnesota Daily Temperature Range: Medium Latitude: 43 Degrees Elevation: 822 ft. Altitude Factor: 0.971 Elevation Sensible Adj. Factor: 1.000 Elevation Total Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Dry Bulb Difference Winter: -16 0 0 70 0 Summer: 95 72 50 75 18 Check Figures Total Building Supply CFM: 1,620 CFM Per Square ft.: 0.339 Square ft. of Room Area: 4,782 Square ft. Per Ton: 1,101 Volume (ft') of Cond. Space: 42,199 Air Turnover Rate (per hour): 2.3 Building Loads Total Heating Required With Outside Air: 104,720 Btuh 104.720 MBH Total Sensible Gain: 39,101 Btuh 89 % Total Latent Gain: 4,779 Btuh 11 % Total Cooling Required With Outside Air: 43,880 Btuh 3.66 Tons (Based On Sensible + Latent) 4.34 Tons (Based On 75% Sensible Capacity) rNotes Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\Elite\Rhvacw\Projects\lee-lyn martens.rhv Thursday, September 27, 2007, 2:09 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. , Metro Air Inc. Martens Residence Prior Lake,MN 55372-3310 Page 3 Load Preview_ Report Sens Lat Net Sens Win Sum Adj Sys Duct _Scope Area Gain Gain Gain Loss CFM CFM CFM CFM Size Building: 3.66 Net Tons, 4.34 Recommended Tons, 1,101 ft.2/Ton, 104.72 MBH Heating Building 4,782 39,101 4,779 43,880 104,720 1,332 1,620 1,620 System 1: 3.66 Net Tons, 4.34 Recommended Tons, 1,101 ft.2/Ton, 104.72 MBH Heating System 1 4,782 39,101 4,779 43,880 104,720 1,332 1,620 1,620 0* Ventilation 4,506 2,495 7,001 19,374 Zone 1 4,782 34,595 2,284 36,879 85,346 1,332 1,620 1,620 1-Basement 1,894 1,640 153 1,793 14,910 233 77 77 77 0-0* 2-Great Room 355 6,917 355 7,272 14,880 232 324 324 324 0-0* 3-Dining Room 282 1,868 128 1,996 5,168 81 87 87 87 0-0* 4-Kitchen 194 957 52 1,009 2,644 41 45 45 45 0-0* 5-Master Bedroom 349 6,792 622 7,414 10,853 169 318 318 318 0-0* 6-Master Bath 135 943 37 980 3,151 49 44 44 44 0-0* 7-Walk In Closet 145 301 0 301 1,097 17 14 14 14 0-0* 8-Entry And Bath 132 489 64 553 2,157 34 23 23 23 0-0* 9-Laundry And Closet 128 1,028 37 1,065 2,705 42 48 48 48 0-0* 10-Foyer 109 1,354 107 1,461 3,849 60 63 75 63 0-0* 11-Study 150 4,061 159 4,220 6,523 102 190 225 190 0-0* 12-Bedroom 2 263 2,778 247 3,025 5,735 90 130 130 130 0-0* 13-2nd Floor Bath 84 828 21 849 1,222 19 39 48 39 0-0* 14-Bonus Room 364 2,346 64 2,410 5,913 92 110 127 110 0-0* 15-Bedroom 3 198 2,293 238 2,531 4,539 71 107 127 107 0-0* 'I L it li C:\Elite\Rhvacw\Projects\lee-lyn martens.rhv Thursday, September 27, 2007, 2:09 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Metro Air Inc. Martens Residence Prior Lake,MN 55372-3310 Page 4 Total Building Summary Loads Component Area Sen Lat Sen Total Description Quan Loss Gain Gain Gain 3A Window Double Pane Clear Glass Wood Frame 404 19,143 0 14,973 14,973 8M Glass Door Double Clear Glass Wood Frame 63 2,985 0 2,037 2,037 9A French Door Single Clear Glass Wood Frame 35 2,814 0 2,240 2,240 10D Door Wood Solid Core 21 831 0 228 228 11C Door Metal Polystyrene Core 21 849 0 233 233 12H Wall R-19 + 1/2" Gypsum Board(R-0.5) 2894 14,932 0 4,099 4,099 15D Wall 2-5' Below Grade 8/12" Blk+R-19 1678 4,906 0 0 0 16H Ceiling R-38 Insulation 1999 4,471 0 2,288 2,288 21A Basemt Floor 2' or More Below Grade 1894 3,909 0 0 0 Subtotals for structure: 54,840 0 26,098 26,098 People: 4 620 980 1,600 Equipment: 0 0 0 Lighting: 0 0 0 Ductwork: 11,132 0 4,513 4,513 Infiltration: Winter CFM: 211, Summer CFM: 141 19,374 1,664 3,004 4,668 Ventilation: Winter CFM: 211, Summer CFM: 211 19,374 2,495 4,506 7,001 Sensible Gain Total: 39,101 Temperature Swing Multiplier: X 1.00 Total Building Load Totals: 104,720 4,779 39,101 43,880 I Check Figures Total Building Supply CFM: 1,620 CFM Per Square ft.: 0.339 Square ft. of Room Area: 4,782 Square ft. Per Ton: 1,101 Volume(ft3)of Cond. Space: 42,199 Air Turnover Rate(per hour): 2.3 Building Loads Total Heating Required With Outside Air: 104,720 Btuh 104.720 MBH Total Sensible Gain: 39,101 Btuh 89 % Total Latent Gain: 4,779 Btuh 11 Total Cooling Required With Outside Air: 43,880 Btuh 3.66 Tons (Based On Sensible + Latent) 4.34 Tons (Based On 75% Sensible Capacity) Notes Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\Elite\Rhvacw\Projects\lee-lyn martens.rhv Thursday, September 27, 2007, 2:09 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Metro Air Inc. *3Martens Residence Prior Lake,MN 55372-3310 Page 5 y rY System 1 Room Load Summa ' T Htg Htg Run Run Cig Cig Clg Zone Clg Air Room Area Sens Nom Duct Duct Sens Lat Nom Adj Adj Sys No Name SF Btuh CFM Size Vel Btuh Btuh CFM Fact CFM CFM --Zone 1--- 1 Basement 1,894 14,910 233 0-0 0 1,640 153 77 1.00 77 77 2 Great Room 355 14,880 232 0-0 0 6,917 355 324 1.00 324 324 3 Dining Room 282 5,168 81 0-0 0 1,868 128 87 1.00 87 87 4 Kitchen 194 2,644 41 0-0 0 957 52 45 1.00 45 45 5 Master Bedroom 349 10,853 169 0-0 0 6,792 622 318 1.00 318 318 6 Master Bath 135 3,151 49 0-0 0 943 37 44 1.00 44 44 7 Walk In Closet 145 1,097 17 0-0 0 301 0 14 1.00 14 14 8 Entry And Bath 132 2,157 34 0-0 0 489 64 23 1.00 23 23 9 Laundry And 128 2,705 42 0-0 0 1,028 37 48 1.00 48 48 Closet 10 Foyer 109 3,849 60 0-0 0 1,354 107 63 1.19 75 63 11 Study 150 6,523 102 0-0 0 4,061 159 190 1.18 225 190 12 Bedroom 2 263 5,735 90 0-0 0 2,778 247 130 1.00 130 130 13 2nd Floor Bath 84 1,222 19 0-0 0 828 21 39 1.25 48 39 14 Bonus Room 364 5,913 92 0-0 0 2,346 64 110 1.15 127 110 15 Bedroom 3 198 4,539 71 0-0 0 2,293 238 107 1.18 127 107 Ventilation 19,374 4,506 2,495 System 1 total 4,782 104,72 1,332 39,101 4,779 1,620 1,713 1,620 0 Cooling System Summary Cooling _Cooling Sensible/Latent Sensible Latent Total Tons Split Btuh Btuh Btuh Net Required: 3.66 89%/ 11% 39,101 4,779 43,880 Recommended: 4.34 75%/25% 39,101 13,034 52,134 C:\Elite\Rhvacw\Projects\lee-lyn martens.rhv Thursday, September 27, 2007, 2:09 PM \ICI DATE TIME \/ 'A Q CITY OF ORONO CALLED IN 10'9'01 6120 A714 INSPECTION N T1I jI SCHEDULED 10'1007 1:CO (?M PERMIT NO. 41(/�- 1 ACIOMPLETED �,�I ADDRESS 21255VV'�� \& ,7nn U`� OWNER CONTR._ 1 TELEPHONE NO. g52--4457 K12-4-- DESCRIPTIONii — IA I t_'La�I 4, ❑ FOOTING MECHANICAL RI ❑ EXCAV/GRADING/FILLING 4. Q ❑ FRAMING ❑ MECHANICAL FINAL ❑ LAKESHORE/WETLANDS y ❑ INSULATION ❑ WOOD BURNER/FIREPLACE ❑ TREE REMOVAL Z ❑ WALL BD. ❑ WATER HOOK-UP ❑ SITE INSPECTION Q ❑ FINAL ❑ SEWER HOOK-UP ❑ PROGRESS ❑ DEMO-SITE ❑ SEPTIC MAINT. ❑ COMPLAINT J ❑ DEMO-FINAL ❑ SEPTIC INSTALL. ❑ FOLLOW-UP 0 PLUMBING RI ❑ SEPTIC FINAL 0 HARD COVER REMOVAL 0 PLUMBING FINAL ❑ FOUNDATION/REMOVAL Z OWNER/CONTRACTOR TO MEET YOU:_YES_NO V) COMMENTS: Air f,y 6y� LUQ.CC Q-- 0 L ev cc 0LL. 2_ liruS -in •)-wparav--- W cc Q „,,...Z W z W d W WORK SATISFACTORY:PROCEED ❑ PROJECT COMPLETE CCW ❑CORRECT WORK&PROCEED ❑ ISSUE CERTIFICATE OF OCCUPANCY O ❑CORRECT WORK,CALL FOR REINSPECTION TEMPORARY U BEFORE COVERING PERMANENT ❑CORRECT UNSAFE CONDITION WITHIN HOURS. ❑ PHOTO TAKEN INSPECTOR WILL RETURN 11STOP ORDER POSTED.CALL INSPECTOR ❑CITATION ISSUED ❑ INSPECTION REQUIRED.CALL TO ARRANGE ACCESS. Call for the next in,• • tion 24 hours in advance. (952) 249-4600 Owner/Contra sit- Inspector. Stir White Copyllnspector's File Canary Copy/Site Notice (1:) /22 T,E 10-7 TIME CITY OF ORONO CALLED IN (p V INSPECTION NI9TICE SCHEDULED J� o7 PERMIT NO. l ( Z( COMPLETED ADDRESS Z (o S- ( ti . t ()-ft �0- OWN ER CONTR. M Q-1`(-C r r TELEPHONE NO. alb a' 7 Y DESCRIPTION Li ❑ FOOTING 0 MECHANICAL RI EXCAV/GRADING/FILLING Q ❑ FRAMING 0 MECHANICAL FINAL ❑ LAKESHORE/WETLANDS ti ❑ INSULATION ❑ WOOD BURNER/FIREPLACE ❑ TREE REMOVAL • ❑ WALL BD. 0 WATER HOOK-UP ❑ SITE INSPECTION Q ❑ FINAL ❑ SEWER HOOK-UP ❑ PROGRESS ❑ DEMO-SITE ❑ SEPTIC MAINT. ❑ COMPLAINT ❑ DEMO-FINAL ❑ SEPTIC INSTALL. ❑ FOLLOW-UP ❑ PLUMBING RI ❑ SEPTIC FINAL ❑ HARD COVER REMOVAL ❑ PLUMBING FINAL ❑ FOUNDATION/REMOVAL • OWN ERICONTRACTOR TO MEET YOU YES NO o COMMENTS: CC W CC O CC O U- W Q W W GW WORK SATISFACTORY:PROCEED PROJECT COMPLETE W ❑CORRECT WORK&PROCEED ❑ ISSUE CERTIFICATE OF OCCUPANCY C) ❑CORRECT WORK,CALL FOR REINSPECTION TEMPORARY 0 BEFORE COVERING PERMANENT El CORRECT UNSAFE CONDITION WITHIN HOURS. ❑ PHOTO TAKEN INSPECTOR WILL RETURN El CITATION ISSUED El STOP ORDER POSTED.CALL INSPECTOR ❑ INSPECTION REQUIRED.CALL TO ARRANGE ACCESS. Call for the next spection 24 hours in advance. (952) 249-4600 Owner/Contract. .'"1" t Inspector. `b White Copy/Inspector's File Canary Copy/Site Notice