Loading...
HomeMy WebLinkAbout1999 - 011165 - mechanical PERMIT CITY OF ORONO PERMIT TYPE: 1750 Kelley Parkway- P.O. Box 66 MECHANICAL Permit Number: Crystal Bay, Minnesota 55323 01 1 1 GS (612) 473Date Issued:-7357 01 i /99 SITE ADDRESS: 1889 wizsr FARM RD JG . N 27-11 S-23-4:3-0015 DESCRIPTION: 1 HEATIN6 SYSTEMS FLUE SIZE 2n FUEL NATURAL GAS CARRIER MODEL 58MXA100 OUTPUT 92, 000 INPUT 100, 000 I REMARKS: FEE SUMMARY: VLUTICiN $2 Surcharge 4:1 09 Total Fee Subtotal $36 . 09 CONTRACTOR: - Applicant - OWNER: DITT R 47895 5 S WHITTEN 820 TOWER RI) 1E89 WES . F MEDINA MN 55340 ORONO N 5.5356 (61 ) 4T8-9SSS 47S-1798 THE UNDERSIGNED HEREBY REQUESTS PFRMISSION 10 MAKE IRE REAL IMPROVEMENTS SPECIFIED AND AGREES TO DO ALL WORK IN STRICT f:OMPLIANCE WITH L L CITY OF ORONO ORDINANCES ANC) .-:;1-rifF OF MINNESOTA RUIinING CODE REWIREMENTS . L_ L0411-4,,i96p U APPLICANT/PERMITEE SIGNATURE ISSUED BY:SIGNATURE JUN 0 9 1998 CITY OF ORONO APPLICATION FOR MECHANICAL PERMIT Box 66 (2750 Kelley Parkway) Crystal Bay, MN 55323 GENERAL INFORMATION 1. You may apply for mechanical permits by mail or in person at the City offices. Applications'will-be,_ reviewed and a permit will be issued within 2 working days. 2. Permit cards will be sent by return mail after a review is completed. PERMITS ARE NOT VALID UNTIL YOU RECEIVE A PERMIT. WORK MUST NOT BEGIN UNTIL THE PERMIT CARD IS POSTED ON THE JOB SITE. 3. Mechanical Designs - Complete calculations, details and specifications are required for each heating, ventilation, humidification-dehumidification, and air conditioning installation including heat loss/heat gain calculation, design temperatures, equipment ratings and identification as to type, manufacturer and model. Data shall be presented on form provided. Identification of and specifications for water heating equipment shall also be provided. 4. When any new construction or remodeling is involved, a separate building permit must be obtained. 5. All work must be done in accordance with the Uniform Mechanical Code/State Building Code requirements. 6. All work must be inspected (rough-in and final). Call 473-7357. 24-hour notice required. 7. House Heating Test Record must be submitted before final. • Instructions Complete all items on this application. Compute the permit fee. Sign and date the certification. INCOMPLETE APPLICATIONS WILL NOT BE PROCESSED. If you have questions, call 473-7357. Please check one: New Addition Repair X Replace Residential Commercial JOB SITE: -/ ? W lag p Zip: Owner's Name: Aev GUb/f fJ Telephone Number: 4/7S /79' Mailing Address: 573/e. City: aerito Zip: Contractor's Name: 72 Telephone Number: 47i--.?3-3-18 Mailing Address: ,Fola 67L P/2 City: 11NeL Zip: S ��3t C) SYSTEM DESCRIPTION HEATING SYSTEMS Quantity: / Make: Model: 'i 4 /o Fuel: /0-G Flue Size: 2" Input BTUs: /*ad Output BTUs: 9'Z CFM: COOLING SYSTEMS Quantity: Make: _ Model: Tons: H. Power • WOOD BURNING EQUIPMENT Wood stove with flue Wood combination or add-on Factory fireplace with flue Factory Fireplace (s) Freestanding Masonry Wood Stove (s) Franklin, other Brand Name Model No. Mfgr's Min., Clearances, side , rear , min. flue dia. VENTILATION No. Kitchen Exhaust ducted recirculating cfm No. Bath Exhaust (must be ducted outside) cfm No. Other Fans: Locations cfm FUEL STORAGE (MUST BE APPROVED BY FIRE MARSHAL) Installation Removal Fuel oil: gallons underground inside outside LP Gas: gallons Other Gas opening PERMIT FEE CALCULATION 1. 1.25% of Contract Price* or Minimum Fee ($35.00) a� /g g — x .0125 $ 1S (contract price) 2. State Surcharge. ** Add the State Building Code Division D Surcharge to each permit. x .0005 $ or $.50, whichever is greater (contract price) 3. Postage and Handling (Only mail-in applications) $ . 4. TOTAL PERMIT FEE (Add lines 1-3 above) * CONTRACT PRICE or JOB COST means the actual or estimated dollar amount charged for the permitted work including materials, labor, profit, and other fixed costs. It is the amount to be charged to the customer for the work done. If any material, equipment, labor, or installation are furnished by the owner, tenant or any other party the reasonable market value of such items must be added to the estimated cost or contract price for permit fee purposes. In the event that there is a dispute on the amount of the job cost, the City may request the submission of a signed copy of the actual contract. ** The STATE SURCHARGE is .0005 of the contract price under $1,000,000 or $.50 - whichever is greater. For valuations over $1,000,000 call the Department of Inspectional Services for the price. The undersigned hereby applies to the City for issuance of a Mechanical Permit, agrees to do all work in strict accordance with the ordinances of the City and the regulations of the Minnesota State Building Code, and certifies that all statements is.de on this application are complete, true and correct. Applicant's Signature: OP /or /,-73/7°9 PP � Approved By: /1/ Date: ! , � 1 I r WHITTEN HVAC LOAD ANALYSIS for Ben Whitten 1889 West Farm Rd. Orono, MN. .,:,::::::::::::::::::::<:t ...,. :.::, , , ..., 7 , . N .: . ..,,.,:„:,:„.. „,; ..„ , . , . , 1 ,... . ... :::.,....... „ .::.,:::.:...,:...,:ar.:, , ..:::..„ ....:, .... ... ..: . ,.. ::.,.:.:.:.:.:.:.:.:.:.:::.:::::::::::::::::::::::::::::::::::::::::::::„:„ ioa',eeeeeR..avvaa..a ia�aa�.ea.<:::::•xaaaaaa RHVACRgSIDENTIAL HVAC LOADS Prepared By: Doug Bjork Ditter Inc. Cooling&Heating 820 Tower Drive Hamel, MN. 55343 478-9558 • RHVAC-Residential&Light Commercial HVAC Loads Program • Elite Software Development,Inc. ;Ditter,ince"" Whitten Flame',MN 55340-9691 Page 2 Project Summary Project: Whitten Company: Ditter Inc. Cooling & Heating Client: Ben Whitten Representative: Doug Bjork Address: 1889 West Farm Rd. Address: 820 Tower Drive City: Orono, MN. City: Hamel, MN. 55343 Phone: Phone: 478-9558 Fax: Fax: 478-2426 Comment: Design Data Project Name: Whitten Reference City: Minneapolis, Minnesota Daily Temperature Range: Medium Latitude: 44 Degrees Elevation: 834 Feet Elevation Sensible Adj. Factor: 1.000 Elevation Total Adj. Factor: 1.000 Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum. Dry Bulb Difference Winter: -20 N/A N/A 72 N/A Summer: 95 75 50% 75 36 Check Figures Total Building Supply CFM: 1059 CFM per square foot: 0.772 Square feet of room area: 1,372 Square feet per ton: 547.836 Building Loads Total heating required with outside air: 71,341 Btuh 71.341 MBH Total sensible gain: 23,141 Btuh 85 % Total latent gain: 4,229 Btuh 15 % Total cooling required with outside air: 27,369 Btuh 2.281 Tons (based on sensible + latent) 2.504 Tons (based on 77% sensible capacity) Notes Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. Thursday,December 31, 1998