HomeMy WebLinkAbout1999 - 011165 - mechanical PERMIT
CITY OF ORONO
PERMIT TYPE:
1750 Kelley Parkway- P.O. Box 66 MECHANICAL
Permit Number:
Crystal Bay, Minnesota 55323 01 1 1 GS
(612) 473Date Issued:-7357 01 i /99
SITE ADDRESS:
1889 wizsr FARM RD
JG
. N 27-11 S-23-4:3-0015
DESCRIPTION:
1 HEATIN6 SYSTEMS FLUE SIZE 2n FUEL NATURAL GAS
CARRIER MODEL 58MXA100
OUTPUT 92, 000 INPUT 100, 000 I
REMARKS:
FEE SUMMARY:
VLUTICiN $2
Surcharge 4:1 09 Total Fee
Subtotal $36 . 09
CONTRACTOR: - Applicant - OWNER:
DITT R 47895 5 S WHITTEN
820 TOWER RI) 1E89 WES . F
MEDINA MN 55340 ORONO N 5.5356
(61 ) 4T8-9SSS 47S-1798
THE UNDERSIGNED HEREBY REQUESTS PFRMISSION 10 MAKE IRE REAL IMPROVEMENTS
SPECIFIED AND AGREES TO DO ALL WORK IN STRICT f:OMPLIANCE WITH L L CITY OF
ORONO ORDINANCES ANC) .-:;1-rifF OF MINNESOTA RUIinING CODE REWIREMENTS .
L_
L0411-4,,i96p
U
APPLICANT/PERMITEE SIGNATURE ISSUED BY:SIGNATURE
JUN 0 9 1998
CITY OF ORONO APPLICATION FOR MECHANICAL PERMIT
Box 66 (2750 Kelley Parkway)
Crystal Bay, MN 55323
GENERAL INFORMATION
1. You may apply for mechanical permits by mail or in person at the City offices. Applications'will-be,_
reviewed and a permit will be issued within 2 working days.
2. Permit cards will be sent by return mail after a review is completed. PERMITS ARE NOT VALID
UNTIL YOU RECEIVE A PERMIT. WORK MUST NOT BEGIN UNTIL THE PERMIT CARD IS
POSTED ON THE JOB SITE.
3. Mechanical Designs - Complete calculations, details and specifications are required for each heating,
ventilation, humidification-dehumidification, and air conditioning installation including heat loss/heat gain
calculation, design temperatures, equipment ratings and identification as to type, manufacturer and model.
Data shall be presented on form provided. Identification of and specifications for water heating equipment
shall also be provided.
4. When any new construction or remodeling is involved, a separate building permit must be obtained.
5. All work must be done in accordance with the Uniform Mechanical Code/State Building Code
requirements.
6. All work must be inspected (rough-in and final). Call 473-7357. 24-hour notice required.
7. House Heating Test Record must be submitted before final. •
Instructions Complete all items on this application. Compute the permit fee. Sign and date the certification.
INCOMPLETE APPLICATIONS WILL NOT BE PROCESSED. If you have questions, call 473-7357.
Please check one: New Addition Repair X Replace
Residential Commercial
JOB SITE: -/ ? W lag p Zip:
Owner's Name: Aev GUb/f fJ Telephone Number: 4/7S /79'
Mailing Address: 573/e. City: aerito Zip:
Contractor's Name: 72 Telephone Number: 47i--.?3-3-18
Mailing Address: ,Fola 67L P/2 City: 11NeL Zip: S ��3t C)
SYSTEM DESCRIPTION
HEATING SYSTEMS
Quantity: /
Make:
Model: 'i 4 /o
Fuel: /0-G
Flue Size: 2"
Input BTUs: /*ad
Output BTUs: 9'Z
CFM:
COOLING SYSTEMS
Quantity:
Make: _
Model:
Tons:
H. Power •
WOOD BURNING EQUIPMENT
Wood stove with flue
Wood combination or add-on
Factory fireplace with flue
Factory Fireplace (s) Freestanding Masonry
Wood Stove (s) Franklin, other
Brand Name Model No.
Mfgr's Min., Clearances, side , rear , min. flue dia.
VENTILATION
No. Kitchen Exhaust ducted recirculating cfm
No. Bath Exhaust (must be ducted outside) cfm
No. Other Fans: Locations cfm
FUEL STORAGE (MUST BE APPROVED BY FIRE MARSHAL)
Installation Removal
Fuel oil: gallons underground inside outside
LP Gas: gallons
Other Gas opening
PERMIT FEE CALCULATION
1. 1.25% of Contract Price* or Minimum Fee ($35.00) a�
/g g — x .0125 $ 1S
(contract price)
2. State Surcharge. ** Add the State Building Code Division
D
Surcharge to each permit. x .0005 $
or $.50, whichever is greater (contract price)
3. Postage and Handling (Only mail-in applications) $ .
4. TOTAL PERMIT FEE (Add lines 1-3 above)
* CONTRACT PRICE or JOB COST means the actual or estimated dollar amount charged for the permitted
work including materials, labor, profit, and other fixed costs. It is the amount to be charged to the
customer for the work done. If any material, equipment, labor, or installation are furnished by the owner,
tenant or any other party the reasonable market value of such items must be added to the estimated cost
or contract price for permit fee purposes. In the event that there is a dispute on the amount of the job cost,
the City may request the submission of a signed copy of the actual contract.
** The STATE SURCHARGE is .0005 of the contract price under $1,000,000 or $.50 - whichever is
greater. For valuations over $1,000,000 call the Department of Inspectional Services for the price.
The undersigned hereby applies to the City for issuance of a Mechanical Permit, agrees to do
all work in strict accordance with the ordinances of the City and the regulations of the Minnesota
State Building Code, and certifies that all statements is.de on this application are complete, true
and correct.
Applicant's Signature: OP /or /,-73/7°9
PP �
Approved By: /1/ Date: ! ,
� 1 I
r
WHITTEN
HVAC LOAD ANALYSIS
for
Ben Whitten
1889 West Farm Rd.
Orono, MN.
.,:,::::::::::::::::::::<:t
...,. :.::, , , ..., 7 , . N
.: .
..,,.,:„:,:„.. „,; ..„ , . ,
. ,
1
,... .
... :::.,....... „
.::.,:::.:...,:...,:ar.:, , ..:::..„ ....:, .... ... ..: . ,..
::.,.:.:.:.:.:.:.:.:.:.:::.:::::::::::::::::::::::::::::::::::::::::::::„:„
ioa',eeeeeR..avvaa..a ia�aa�.ea.<:::::•xaaaaaa
RHVACRgSIDENTIAL
HVAC LOADS
Prepared By:
Doug Bjork
Ditter Inc. Cooling&Heating
820 Tower Drive
Hamel, MN. 55343
478-9558
•
RHVAC-Residential&Light Commercial HVAC Loads Program • Elite Software Development,Inc.
;Ditter,ince"" Whitten
Flame',MN 55340-9691 Page 2
Project Summary
Project: Whitten Company: Ditter Inc. Cooling & Heating
Client: Ben Whitten Representative: Doug Bjork
Address: 1889 West Farm Rd. Address: 820 Tower Drive
City: Orono, MN. City: Hamel, MN. 55343
Phone: Phone: 478-9558
Fax: Fax: 478-2426
Comment:
Design Data
Project Name: Whitten
Reference City: Minneapolis, Minnesota
Daily Temperature Range: Medium
Latitude: 44 Degrees
Elevation: 834 Feet
Elevation Sensible Adj. Factor: 1.000
Elevation Total Adj. Factor: 1.000
Outdoor Outdoor Indoor Indoor Grains
Dry Bulb Wet Bulb Rel.Hum. Dry Bulb Difference
Winter: -20 N/A N/A 72 N/A
Summer: 95 75 50% 75 36
Check Figures
Total Building Supply CFM: 1059 CFM per square foot: 0.772
Square feet of room area: 1,372 Square feet per ton: 547.836
Building Loads
Total heating required with outside air: 71,341 Btuh 71.341 MBH
Total sensible gain: 23,141 Btuh 85 %
Total latent gain: 4,229 Btuh 15 %
Total cooling required with outside air: 27,369 Btuh 2.281 Tons (based on sensible + latent)
2.504 Tons (based on 77% sensible capacity)
Notes
Calculations are based on 7th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
Thursday,December 31, 1998