HomeMy WebLinkAboutSeptic System Inspections LOCATION INSPECTION RECORD PUMPOUT RECORD SKETCH DATE COMPLIANCE DATE GALLONS © sc.4eraacin)6 nxr&-z � 6-l3-'6O /.s-UO ;,-) -7-a 7 no saf is n� hnf2ct q ._ _ — _.■ 11— - S —� 'QD HD Sc�!'-rnur►i Z ' l V;7"j".112*0 I i Ss - / Ir(clude: 1) Well location ii - — 2) Distance from house to IS- '3-‘f f septic tanks,dist.box, and drainfield C— CONFORMING S—SUBSTANDARD N —NONCONFORMING 3) North arrow and road } �f t Y CITY OF ORONO Date ADDRESS Connected to CODE SEPTIC SYSTEM INVENTORY CARD Municipal Sewer y� Gd' R2CC /J. Rc1..0 Address /80/ 0), /^A I2YA. /`b Property I.D. 3-7 I/C6 Z 9, +-/y 00 I,Z ', WELL I ATA Standard trench iv,- 1S— BLc,c� I I O Mound / System type I7 Other Legal Description ',-71r'nM_ nr L3,...,,,• fAv a 6 1 -F., Permit No. ZR{pnDate of permit I–//-69 Installer PE7.-7� C.U.v 4 , -0 ZS L/ ire m No. Bedrooms Garbage v Building type g.....eipouce or GPD 3 SR_ Laundry x Dishwasher Disposal t - o 0 E a SEPTIC TANKS: Material CO/OC– pLtX_k Capacity 1)‘72) ° ¢ •o Tu a cu Proper outlet and inlet Baffles Liquid depth to RO level I 0 Height of tank bottom above water table Distance to nearest building "7 + O so co b DRAINFIELD: Total length of lines Number of lines Trench width • Y Total treatment area(sq.ft.) Height of drainfield above water table co u Type of filter material Soil type a r•-• N N E -c Distance from nearest bldg. Tile size Perc rate min/in 2 a �, c d > 0 v co Depth of fill over drainfield Depth of rock over tile under tile c a. a •Q ••i J�a 2 e• L A On the North Shore of Lake Minnetonka ON-SITE SEWAGE TREATMENT INSPECTION REPORT CITY POST OFFICE BOX 66 OF 1335 S. Brown Rd. ORONO Crystal Bay, MN 55323 473-7357 OWNER -7;r'+077+`/ /4DArvxS ADDRESS /80/ G.) f. i ,►�1 /�� , PHONE PERMIT NO'S. 2ZS'-/ DATES q-/i-69 City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below: ❑ Meets or exceeds current city standards in all respects relating to design, construction, and location. Appears 1 to be operating properly. ,, 2 Does not meet current city standards in some respects relating to design, construction, or location. Appears to be operating properly. ❑ Does not meet current city standards in many respects relating to design, construction, or location. Appears to be operating adequately. ElDoes not meet current city standards of design, construction or location, is being overused, or is failing to properly treat and dispose of the current input and is therefore endangering a water supply, is a source of pollution to surface or groundwaters, is creating a safety hazard,or is otherwise creating a public nuisance. Please contact the inspector to discuss requirements for repairs to your system. Soil testing may be re- quired. In all cases a design and site plan must be submitted for review. Your contractor must obtain a permit before work is started. WORK REQUIRED: ❑ Septic tanks must be pumped within 48 hours. ❑ Drainfield must be repaired or replaced within 90 days. ❑ Inspection riser (4"diam. pipe) must be installed in each tank. ❑ Tank inspection indicates maintenance pumpout is needed as soon as possible. City ordinance requires that tanks be pumped out every three years. SITE CHARACTERISTICS: Limiting Site Factors Potential for System Failure Site Capabilities for 0 Slope (depends on soil types,water Future Expansion 0 Soil table,and system condition) Adequate ❑High water table $,Low Fair ❑Lot size 0 Medium 0 Poor ❑Lake,wetland,or stream 0 High 0 Inadequate 0 Drainage 0 System is causing visible surface discharge. COMMENTS: 6—//-go f 4w • Date of Inspection Septic System Ins,r•' or This report must be kept on the premises with system location and pumping records. WHITE COPY/ Inspector's File GOLD COPY/Homeowner On the North Shore of Lake Minnetonka ON-SITE SEWAGE TREATMENT CITY INSPECTION REPORT OF POST OFFICE BOX 66 ORONO 1335 S. Brown Rd. Crystal Bay, MN 55323 473-7357 OWNER Thn OA f \OC 1 JQJ ADDRESS ) OI VJQ-5f Ri('M 2 1 PERMIT NO.'S. aaS I 'r DATES ~69 CONTRACTORS P44-e-4-50n �, Co( City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is A an existing system 0 new construction) ▪ 1 Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating properly. ® 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, located, and constructed generally in accordance with previous codes.System appears to be functioning properly; no major upgrading of the system is required at this time. ▪ 3 Does not meet current City standards in many respects relating to design,construction, or location.Appears to be operating adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at this time. O 4 System may or may not meet current City standards for design,construction or location, but is failing to properly treat and dispose of the current input,and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is creating a safety hazard,or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/ replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan must be submitted for review.Your contractor must obtain a permit before work is started. SYSTEM CONDITION ( m Checked items may require your action) Tank inspection indicates: 0 Inspection pipe is located directly over tank baffle.(Does not ❑ Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks ❑ Solids accumulation in tanks indicates they should be pump- have not been pumped out within the last three years,they ed out this year to help prevent future problems. should be pumped out now. ❑ Solids accumulation in tanks is at a critical level. Tanks Drainfield inspection indicates: Q � should be pumped out as soon as possible. Drainfield is dry,no surfacing evident. ❑ System is discharging to surface. Tanks must be pumped 0 Some evidence of surfacing,not critical yet. within 48 hours to eliminate surface discharge. 0 Drainfield is saturated and visibly discharging untreated I$ Inspection risers missing—tanks could not be inspected, effluent to the surface. This condition may require replace- Inspection risers (4" dia. pipe)must be installed in each tank ment or additions to drainfield. Contact the City Inspector at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days. the last three years,they should be pumped out now. ❑ Drainfield extent and condition unknown. SITE CHARACTERISTICS: Limiting Site Factors Potential for System Failure Site Capabilities for ❑ Slope (depends on soil types,water Future Expansion ❑ Soil table,and system condition) 2 Adequate 0 High water table 0 Low 0 Fair ❑ Lot size ® Medium 0 Poor ❑ Lake,wetland,or stream 0 High 0 Inadequate ❑ Drainage 0 System is causing visible surface discharge. -L COMMENTS: Tri l3u-� JE T`�(Z�Qr ./421._('5 Q UO�d clmin 2-trt T't1j,,.ra and 05+(b rQ c tc'S. / 7- 7— 7 -7'YJce: Date of Inspection Septic S Spector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with system location and pumping records. WHITE COPY/Inspector's File GOLD COPY/Homeowner �� On the North Shore of Lake Minnetonka ON-SITE SEWAGE TREATMENT CITY INSPECTION REPORT OF POST OFFICE BOX 66 ORONO 1335 S. Brown Rd. Crystal Bay, MN 55323 473-7357 OWNER ay(a4-014( ieJ I ADDRESS /CJ O/ �� - �Qn/1N1 ?el- ' PERMIT NO.'S. (22c4tf` DATES ` 'II-10q CONTRACTORSEi61c7✓\ City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected cn a regular basis.The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is 0 an existing system 0 new construction) El1 Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating properly. 02 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, located, and constructed generally in accordance with previous codes.System appears to be functioning properly; no major upgrading of the system is required at this time. 0 3 Does not meet current City standards in many respects relating to design, construction,or location.Appears to be operating adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at this time. 0 4 System may or may not meet current City standards for design,construction or location, but is failing to properly treat and dispose of the current input,and is endangering a water supply, or is a source of pollution to surface or groundwaters,or is creating a safety hazard, or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/ replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan must be submitted for review.Your contractor must obtain a permit before work is started. SYSTEM CONDITION ( m Checked items may require your action) Tank inspection indicates: 0 Inspection pipe is located directly over tank baffle.(Does not ❑ Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks ❑ Solids accumulation in tanks indicates they should be pump- have not been pumped out within the last three years, they ed out this year to help prevent future problems, should be pumped out now. ❑ Solids accumulation in tanks is at a critical level. Tanks Drainfi d inspection indicates: should be pumped out as soon as possible. Drainfield is dry,no surfacing evident. ❑ System is discharging to surface. Tanks must be pumped Some evidence of surfacing,not critical yet. Iithin 48 hours to eliminate surface discharge. 0 Drainfield is saturated and visibly discharging untreated nspection risers missing—tanks could not be inspected, effluent to the surface. This condition may require replace- Inspection risers (4" dia. pipe)must be installed in each tank ment or additions to drainfield. Contact the City Inspector at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days. the last three years,they should be pumped out now. 0 Drainfield extent and condition unknown. SITE CHARACTERISTICS: Limiting Site Factors Potential for System Failure Site Capabilities for 0 Slope (depends on soil types,water Future Expansion ❑ Soil table,and system condition) XAdequate ❑ High water table ❑}ow 0 Fair ❑ Lot size )'Medium 0 Poor ❑ Lake,wetland,or stream 0 High 0 Inadequate ❑ Drainage 0 System is causing visible surface discharge. COq�MENTS: 1.A.' / f' h % 14 'AI J. Ii. I �� , 9i� I . i 4' alODaa' s S cis+C, bm,+" ii- J�s 4 wor m - r,,)or, t�?seAA usG- ` i O. 'Rulertdula '1�urv►i ►�I�I,Of• G6ue,S� p � D 4 A. . Date of Inspection Septic System I pector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with system location and pumping records. WHITE COPY/Inspector's File GOLD COPY/Homeowner On the North Shore of Lake Minnetonka ON-SITE SEWAGE TREATMENT CITY INSPECTION REPORTOF POST OFFICE BOX 66 ORONO 1335 S. Brown Rd. Crystal Bay, MN 55323 (� 473-7357 OWNER Jc�rn-&S er )°fl+ j ADDRESS /OC1) We 57 yjr RI PERMIT NO.'S. 3.27g ! DATES 67.-- _90CONTRACTORS Day 1- x c City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is -a an existing system ❑ new construction) 1 Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating properly. Int 0 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, located, and constructed generally in accordance with previous codes.System appears to be functioning properly; no major upgrading of the system is required at this time. 3 Does not meet current City standards in many respects relating to design,construction,or location.Appears to be operating adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at this time. 4 System may or may not meet current City standards for design,construction or location, but is failing to properly treat and dispose of the current input,and is endangering a water supply, or is a source of pollution to surface or groundwaters,or is creating a safety hazard,or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/ replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan must be submitted for review.Your contractor must obtain a permit before work is started. SYSTEM CONDITION ( Checked items may require your action) Tank inspection indicates: 0 Inspection pipe is located directly over tank baffle.(Does not • Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks ❑ Solids accumulation in tanks indicates they should be pump- have not been pumped out within the last three years, they ed out this year to help prevent future problems. should be pumped out now. ❑ Solids accumulation in tanks is at a critical level. Tanks Drainfield inspection indicates: should be pumped out as soon as possible. El Drainfield is dry,no surfacing evident. ❑ System is discharging to surface. Tanks must be pumped 0 Some evidence of surfacing,not critical yet. within 48 hours to eliminate surface discharge. 0 Drainfield is saturated and visibly discharging untreated ❑ Inspection risers missing—tanks could not be inspected, effluent to the surface. This condition may require replace- Inspection risers (4" dia. pipe)must be installed in each tank ment or additions to drainfield. Contact the City Inspector at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days. the last three years,they should be pumped out now. 0 Drainfield extent and condition unknown. SITE CHARACTERISTICS: Limiting Site Factors Potential for System Failure Site Capabilities for ❑ Slope (depends on soil types,water Future Expansion ❑ Soil table,and system condition) Adequate ❑ High water table 0 Low Fair ❑ Lot size al Medium 0 Poor ❑ Lake,wetland,or stream 0 High 0 Inadequate El Drainage 0 System is causing visible / surface discharge. COMMENTS: 6/e5/l hot))-t' G�%hi,ec-,'/ �kli4 5-y51-ft 6/7,26—M614}4z/L7,11,_____ Date of Inspection Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with system location and pumping records. WHITE COPY/Inspector's File GOLD COPY/Homeowner , , , . // sfcoP1 . . CITY OF ORONO Permit # SEPTIC SYSTEM APPROVAL Fee $___________---_ i. r Entered By The General Contractor will be given a copy of this report and is responsible for its distribution to unlessll nthis sheettissattachedc system design is not considered as approved r. 001 JG:;7 t LOCATION: y , - (, ,,S-C1 a GAL CONTRACTOR: ST-ef1-101\3_5'01`J CoNs . PHONE: SEPTIC CONTRACTOR: OWNER: c) et.N 'c- D APPROVED c0.41.;,, - \ . `' CONDITIONALLY APPROVED: Note es. Below COMMENTS: 0 - _ 0 , Aid.;‘, QNB G r' it i76,X/:7,1,,K1 •4 .a. • „gid► Alt K. V R?'� * r !" �. NCS► NN ' 'ta - p1A . d G am`'" r C.4. ' • kL-D t 3 LI C '� alb4 `^ � • F- tat J tot ALP ,1 / C417O►M,J ^ ("',1AJ r ?SC No O elb .41 11 e A 1_S " t ' AR,-* " . wit'� �/L .2'. :i e NOTICE TO INSTALLERS: Any changes to the approvedll foran andinspspecs cm2 sthouvs ' prior approval of the Inspector (473-7357). in advance. NOTICE TO GENERAL CONTRACTORS: Drainfield sites must be protected prior to natural soil. and after system installation toFavo el mi ate tion of the all traffic over them. Drainfield areas must be fenced off to Date Approved By � T�,�pa i¢ I e . , , ,. .4ic....# . ,. c.... eitr''' '' t d 4414. N ti \�y bJ 0 v_ i /(,,,e- 9ki .. .. . , . , -r° CITY OF ORONO 0 Municipal Offices O O Post Office Box 66 Crystal Bay, MN 55323-0066 a '� l ON—SITE SEWAGE TREATMENT Alm' INSPECTION REPORT riAlI ktS110 Owner: , aTee5 Per .Address: / / lA 4S-i-T)/)Y\ 2_ Permit #'s: 22 Rep,'Repur Dates: 3—)/4/ Contractors: if-404,r50 +CO, City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is C)&an existing system [ ] new construction) SYSTEM CONFORMITY (1-3): "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic [ ] has orhas not been identified at this time. If the limiting soil characteristic has not been identified, this c assification may be subject to revision.) TANK CONDITION (5-10): CI Tank inspection indicates: 5 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. bISystem is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped out now. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been pumped out within the last three years, they should be pumped out now. DRAINFIELD CONDITION (11-14): /1 Dr nfield inspection indicates: 11 Drainfield is dry, no surfacing evident. Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (slope,setbacks,etc.): POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): �vYY COMMENTS y��Ptacceti�� q /ns iy4r . • -Teinks , � piled 9-?0 aSn shy/6/ Le Date of Inspection epic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the system location and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner CITY OF ORONO O Municipal Offices O .41O Post Office Box 66 = �, Crystal Bay, MN 55323-0066 '‘' ,. ON—SITE SEWAGE TREATMENT ,0I. INSPECTION REPORT l 1 4lr11i 4C)�, 9\\\\N kESIiO�' Owner: IJ ?flK k + Address: MD) IA 1<c F frr W. -�,C3 ' k,,�" (1-1)-69 Pie{ DY (b. Permit #'s: c�aC=�7 �Cµ►�tbates: Contractors: City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is b(an existing system [ ] new construction) SYSTEM CONFORMITY (1-31: 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging /� any pollutants into ground or surface waters. C 3 1 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which isfailing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribsttinn device and the limiting soil characteristics. ,� J/(The limiting soil characteristic I� has or [ ] has not been identified ak t��is tirr ffthe mriting soil r�� characteristic has not been identified, this classification may be subject to revision.) • TANK CONDITION (5-10): 7 j�` it pd /eke/ Tank inspection indicates: 5 Pumpout not nee this time. Solids ac ation in tanks indicates they should be ed out this year to help prevent future problems. 7 . n in tanks is at a critical level. Tanks should be pumped out as soon as possible. System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped out now. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been pumped out within the last three years, they should be pumped out now. DRAINFIELD CONDITION (11-14): )) A Dr nfield inspection indicates• �I 11, Drainfield is ur ac' g evident. Some evidence of sur'f'acing, not Crtttt-al yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (slope,setbacks,etc.): 4-r- - POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): it1-., COMM TS: . �� /1' IP(N.R'. C A1*O' h�' h'.0 .4 AC I All el a of 0 (' .' rook IA.4 �l ! �' t f f r" - •YDI, e an, Q - ! r / (" •`'' , / rr, r • /AA /A '. '..C Ilk�L 1..-co . v-rn(n• S 'm Yqi MPS I bP CO ( by J l Dat- of Inspection Sept ' - stem Inspector ?-31--97s Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the system location and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner ogiev, O O CITY of ORONO '''A :4: lir, Municipal Offices a ti ����.4 I `���;` Street Address: Mailing Address: `9 ZElli , 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 Owner: -37). /'- mA Fien-f--- e Address: 1801 West Farm Rd. Permit #'s: 2254 Dates: 9/11/69 Contractors: E. J. Peterson (This is x] an existing system [ ] new construction) . SYSTEM COMPLIANCE (1-3) : 3 1 Code System: Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. 2 Compliant System: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance with previous 033codes and is functioning properly. Non-Compliant System: System may or may not meet current City standards for design, construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level. (The saturated soil level is ] or is not [ ] identified under this septic system. If the saturated soil level is not identified, this classification is subject to revision.) TANK CONDITION (5-9) : 8 5 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year. System is discharging to the surface. Tanks must be pumped out within 48 hours.0/ 8a Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out v within three years, they should be pumped out and risers installed now. 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks have not been pumped out within three years, they should be pumped out now. 10 One or more tanks are cesspools, which means the septic system is non-compliant. (The tanks are [ ] or are not [ ] water tight or the condition is !] unknown. If the tanks are not confirmed to be watertight, this classification is subject to revision.) DRAINFIELD CONDITION (11-14) : 13 11 Drainfield is dry, no surfacing evident. Some evidence of surfacing, not critical yet. Repair is not required at this time. 6Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : failing COMMENTS: The septic system is an imminent threat to public health or safety and must be repaired by 11/31/98. R/39(z ,v 2! , , .2,ifiy.2,2„e„...___„ Date of Inspection Se! is System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicates the operation of the system under current conditions. Telephone (612) 473-7357 • FAX 473-0510 :c1%) 4". 7/O CITY of ORONO dl '� tv Municipal Offices i e"Ap�G Street Address: Mailing Address: 2750 Kelley Parkway P.O. Box 66 March 244 200 Orono, MN 55356 Crystal Bay, MN 55323-0066 James Pierpont 1801 west Farm Road Long lake,Mn 55356 Dear Mr. Pierpont An inspection of your septic system was conducted on March 22, 2000. The system was installed on September 11, 1969 by E.J. Peterson. A summary of the inspection is below. Septic Tank Condition 1. Pumpout needed when septic tanks become full The septic system is non-compliant because it is failing by visibly discharging untreated sewage to the surface. This is considered to be an imminent public health threat. This discharge could have adverse effects to the environment including contamination of your well or neighboring wells. City Code requires that the system be repaired or replaced within 90 days upon the date of this letter. The home will need to connect to the municipal sewer system when it becomes available. The septic tanks must be used as holding tanks and pumped when full so as not to discharge untreated sewage to the surface until the home is connected to municipal sewer. Enclosed is a list of state licensed septic contractors who regularly work in Orono. Also enclosed is a fact sheet explaining how a septic system functions. Finally, an as-built drawing is enclosed showing the approximate location of the septic system. Please contact the inspector at the City Offices at 249-4600 if there are any questions regarding this situation, s ectful 's Pence On-Site Systems Manager Enclosure In the event this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does no guarantee or certify the existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. • This report must be kept on the premises with the system location and pumping records. Telephone(612)249-4600 • Fax(612)249-4616 • lk, 0.47. o..sr, o ..„,..,•... . = . CITY of OIIONO ,.' 1 )-11,-)---- .. E,► ,� '1.'°4'21:1-Qtr Gti Municipal Offices 'Z I'i Y` l isy Street Address: Halling Address: E$I30g' 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323.0066 95d- 41-4600SrTo Current Owner: Address: I 0 ° \ Vi t51' Fel C e-, IV City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFORMITY (1-3): 3 I "CODE SYSTEM"An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and which is not failing or an imminent threat to public health or safety. 0 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. TANK CONDITION 6--7.1: Tank inspection indicates: 5 Pumpout not needed at this time. •Septic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years. Tank was last pumped 1-A-\ -'D ). Make sure septic tanks are pumped through manhole and not through white inspection pipes. This allows for the proper cleaning. 7 Inspection risers missing tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. D INFIELD CONDITION($-10): S Drainfield is dry,no surfacing evident. 8 . r. Some evidence of surfacing,not critical yet. 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately.Repairs must be completed within 90 days. 4 • COMMENTS: .c 1 c> ;S o c. c �_k 1. c - `v-vd c--,\V - k (-' Ic.c t d b7 1-,-=3,- LC O - P,'—k Sc ' .L `r )? n __`1.-\--- .. 5 (.,, - put- (O'CrS er\ (A(c.,C r S , 6)-v\arc-_ iS-r117---- --_, Date of Inspection Matt Bolterman - Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information.