HomeMy WebLinkAboutSeptic System Inspections 7iti
-;":
CITY OF ORONO O
Municipal Offices O O
Post Office Box 66 - Ep.
Crystal Bay, MN 55323-0066 , ON—SITE SEWAGE TREATMENT
�'l. �Il Iv INSPECTION REPORT
y ��M°
9kESH.O4�
Owner: £nni: / IIer:OY\ Address: — 441hP1�g/L< Pi
Permit #'s: T Dates: //—/5--744 Contractors: 7777,PS acs
City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked below.
(This is 941 an existing system [ ] new construction)
SYSTEM CONFORMITY (1-3):
1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
�� without discharging any pollutants into ground or surface waters.
l2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the
current City Codes, but was installed according to the code in effect at the time of installation, and which
is operating satisfactorily by treating and disposing of the entire current sewage input without discharging
any pollutants into ground or surface waters.
3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any
system which may or may not meet all the location, design, and construction standards of the current City
Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand
between the distribution device and the limiting soil characteristics.
(The limiting soil characteristic [ ] has or has not been identified at this time. If the limiting soil
characteristic has not been identified, this c assification may be subject to revision.)
TANK CONDITION (5-10): S
Tank inspection indicates:
��-��, Pumpout not needed at this time.
(6J Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems.
`77 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible.
8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge.
9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each
tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped
out now.
10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation).
If tanks have not been pumped out within the last three years, they should be pumped out now.
DRAINFIELD CONDITION (11-14): j)
Dr field inspection indicates:
Drainfield is dry, no surfacing evident.
1/1 Some evidence of surfacing, not critical yet.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately. Repairs must be completed within 90 days.
14 Drainfield extent and condition unknown.
LIMITING SITE FACTORS (slope,setbacks,etc.): r,/v��p�
POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): A""7 /1i17\
COMMENTS:
? efDatInspection Septic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or certify that an existing system will continue to function
properly, but is merely an opinion of the adequacy of the system under current conditions based on the available
information.
This report must be kept on the premises with the system location and pumping records.
WHITE COPY/Inspectors File YELLOW COPY/Homeowner
CITY OF ORONO
Municipal Offices //4;./1:1 -418k
Post Office Box 66 4.\, , o,
Crystal Bay, MN 55323-0066 r ON–SITE SEWAGE TREATMENT
1214 l• ' INSPECTION REPORT
9kESH0�
Owner: Z. PedpXyN Address: gS I'L44 ( Al's- •
Permit #'s: /DoZ Dates: 1/—)se-7/1) Contractors: )1çac.
City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked below.
(This is D4, an existing system [ ] new construction)
SYSTEM CONFORMITY (1-3): O�
1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
1) without discharging any pollutants into ground or surface waters.
"CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the
current City Codes, but was installed according to the code in effect at the time of installation, and which
is operating satisfactorily by treating and disposing of the entire current sewage input without discharging
any pollutants into ground or surface waters.
3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any
system which may or may not meet all the location, design, and construction standards of the current City
Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand
between the distribution device and the limiting soil characteristics.
(The limiting soil characteristic [ ] has orhas not been identified at this time. If the limiting soil
characteristic has not been identified, this c assification may be subject to revision.)
TANK CONDITION (5-10):
Tank inspection indicates:
PPumpout not needed at this time.
S. . . umulation in tanks indicates the should be 4.6•-• out this year to help prevent future •roblems.
Solis accumu ation in - a cri Ica eve . - • .. . . •. . ..
8 System is discharging to the surface. Tanks must be pumped out within 48hours to eliminate surface discharge.
9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each
tank at next pumpout. if tanks have not been pumped out within the last three years, they should be pumped
out now.
10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation).
If tanks have not been pumped out within the last three years, they should be pumped out now.
DRAINFIELD CONDITION (11-14): ))
Drprgfield inspection indicates:
Y (1 V Drainfield is dry, no surfacing evident.
CC//�` i Some evidence of surfacing, not critical yet.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately. Repairs must be completed within 90 days.
14 Drainfield extent and condition unknown.
LIMITING SITE FACTORS (slope,setbacks,etc.):
POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): Ade'^ `L/-
COMMENTS: ��/ �K�l e, I eI ♦(fll I b + Ati A kt a AIA t I/
I1]k° • :♦ -e, no /G me I - eix attz.J any - frits , li
Ally
'/�: .41
D to of Inspection Sep• c System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or certify that an existing system will continue to function
properly, but is merely an opinion of the adequacy of the system under current conditions based on the available
information.
This report must be kept on the premises with the system location and pumping records.
WHITE COPY/Inspectors File YELLOW COPY/Homeowner
1. o.4,.
O O
CITY of ORONO
\v1/* Aq
y rti Municipal Offices
+•� � �;14.N.,„ G~ Street Address: Mailing Address:
`q�EggOg' 2750 Kelley Parkway P.O. Box 66
p �/� Orono, MN 55356 Crystal Bay, MN 55323-0066
owner: )'K Prier- Address: 2285 Webber Hills Rd.
Permit #'s: 4702 Dates: 11/18/76 Contractors: Hayes Exc.
(This is [X] an existing system [ ] new construction) .
SYSTEM COMPLIANCE (1-3) : 3
1 Code System: Meets or exceeds current City standards in all respects relating to design,
construction, and location. Appears to be operating properly.
2 Compliant System: Does not meet all current City standards for new construction, but in
most respects appears to be designed, located, and constructed in accordance with previous
codes and is functioning properly.
Non-Compliant System: System may or may not meet current City standards for design,
construction, or location, but is failing to properly treat and dispose of the current
input; and any system with less than three feet of vertical separation between the bottom
of the drainfield and the saturated soil level.
(The saturated soil level [X. has or [ ] has not been identified at this time. If the
saturated soil level has not been identified, this classification is subject to revision.)
TANK CONDITION (5-9) : 6
0Pumpout not needed at this time.
Solids accumulation in tanks indicates they should be pumped out this year.
System is discharging to the surface. Tanks must be pumped out within 48 hours.
8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out
within three years, they should be pumped out and risers installed now.
9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks
have not been pumped out within three years, they should be pumped out now.
(During the last septic tank Maintenance Pumpout the tanks [ ] were or [)] were not confirmed
to be watertight by the licensed pumping contractor. If the tanks were not confirmed to be
watertight, this classification is subject to revision.)
INFIELD CONDITION (11-14) : 11
Drainfield is dry, no surfacing evident.
12 Some evidence of surfacing, not critical yet. Repair is not required at this time.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface.
Contact the City Inspector immediately. Repair must be completed within 90 days.
14 Drainfield extent and condition unknown.
POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc. ) : medium
COMMENTS: In order to confirm that your septic system meets Minnesota standards, soil borings
were performed to verify a 3 foot separation between the drainfield and the seasonal water
table. The separation is 0 feet and the system is non-compliant. Repair or replacement of the
septic system is required by 12/31/2007 .
1/-3-7) 4 ,/,,, , Uoingr---
Date of Inspection Sep/ic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a
transfer of property, this report does not guarantee that an existing system will continue to
function properly, but indicates the operation of the system under current conditions.
Telephone (612) 473-7357 • FAX 473-0510