HomeMy WebLinkAboutSeptic System Inspections ` On the North Shore of
Lake Minnetonka
ON-SITE SEWAGE TREATMENT CITY
INSPECTION REPORT OF POST OFFICE BOX 66
ORONO 1335 S. Brown Rd.
Crystal Bay, MN 55323
473-7357
OWNER D
0N L e G,iEY LI
ADDRESS ZC L5 i�/� r, fiiLts
PERMIT NO.'S. '4 DATES ,2,)-- 6)5 CONTRACTORS Aiiry,T1
City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The on-site sewage
treatment system at the above dress has been inspected and appears to fall into the category checked below.
(This is an existing system 0 new construction)
D1 Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating
properly.
2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed,
located, and constructed generally in accordance with previous codes. System appears to be functioning properly;no major
upgrading of the system is required at this time.
0 3 Does not meet current City standards in many respects relating to design,construction, or location.Appears to be operating
adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at
this time.
EJ4 System may or may not meet current City standards for design,construction or location, but is failing to properly treat and •
dispose of the current input, and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is
creating a safety hazard,or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/
replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan
must be submitted for review.Your contractor must obtain a permit before work is started.
SYSTEM CONDITION ( El Checked items may require your action)
Tank inspection indicates: 0 Inspection pipe is located directly over tank baffle.(Does not
`❑ Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks
TJ Solids accumulation in tanks indicates they should be pump- have not been pumped out within the last three years, they
ed out this year to help prevent future problems. should be pumped out now.
❑ Solids accumulation in tanks is at a critical level. Tanks Drainfield inspection indicates:
should be pumped out as soon as possible. 0 Drainfield is dry,no surfacing evident.
❑ System is discharging to surface. Tanks must be pumped 0 Some evidence of surfacing,not critical yet.
within 48 hours to eliminate surface discharge. 0 Drainfield is saturated and visibly discharging untreated
❑ Inspection risers missing—tanks could not be inspected, effluent to the surface. This condition may require replace-
Inspection risers (4" dia. pipe)must be installed in each tank ment or additions to drainfield. Contact the City Inspector
at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days.
the last three years,they should be pumped out now. Drainfield extent and condition unknown.p
SITE CHARACTERISTICS: / RCstu,/cD /clgC' NY
Limiting Site Factors Potential for System Failure Site Capabilities for
❑ Slope (depends on soil types,water Future Expansion
❑ Soil table,and system condition) 0 Adequate
❑ High water table 0 Low 0 Fair
" Lot size —E] Medium 0 Poor
❑ Lake,wetland,or stream 0 High 0 Inadequate
❑ Drainage 0 System is causing visible
surface discharge.
COMMENTS:
Date of Inspection Septic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that
this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy
of the system under current conditions based on the available information.
This report must be kept on the premises with system location and pumping records.
WHITE COPY/Inspector's File GOLD COPY/Homeowner
(\\
\. On the North Shore of
Lake Minnetonka
ON-SITE SEWAGE TREATMENT CITY
INSPECTION REPORT OF POST OFFICE BOX 66
ORONO 1335 S. Brown Rd.
Crystal Bay, MN 55323
473-7357
OWNER
Alla/tI (Trcc� ADDRESS o0 L 5 1, i^ �Le-t. 1416 ? J W
PERMIT NO.'S. S2i / DATES lc .-o?a -6;5 CONTRACTORS A, • , C'S
City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The on-site sewage
treatment system at the above address has been inspected and appears to fall into the category checked below.
(This is)n existing system 0 new construction)
El1 Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating
properly.
cy:C
2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed,
located, and constructed generally in accordance with previous codes. System appears to be functioning properly; no major
upgrading of the system is required at this time.
O 3 Does not meet current City standards in many respects relating to design, construction,or location.Appears to be operating
adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at
this time.
O 4 System may or may not meet current City standards for design,construction or location, but is failing to properly treat and
dispose of the current input, and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is
creating a safety hazard,or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/
replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan
must be submitted for review.Your contractor must obtain a permit before work is started.
SYSTEM CONDITION ( m Checked items may require your action)
Tank inspection indicates: 0 Inspection pipe is located directly over tank baffle.(Does not
❑ Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks
❑ Solids accumulation in tanks indicates they should be pump- have not been pumped out within the last three years, they
ed out this year to help prevent future problems. should be pumped out now.
❑ Solids accumulation in tanks is at a critical level. Tanks Dr inf'eld inspection indicates:
should be pumped out as soon as possible. Drainfield is dry,no surfacing evident.
❑ System is discharging to surface. Tanks must be pumped 0 Some evidence of surfacing,not critical yet.
2eithin 48 hours to eliminate surface discharge. 0 Drainfield is saturated and visibly discharging untreated
—tanks could not be inspected. effluent to the surface. This condition may require replace-
- iia pipe► ►:+ewe sta"ea'^ cl tank ment or additions to drainfield. Contact the City Inspector
af-3e0AffErrarrerseert. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days.
the last three years,they should be pumped out now. 0 Drainfield extent and condition unknown.
SITE CHARACTERISTICS:
Limiting Site Factors Potential for System Failure Site Capabilities for
❑ Slope (depends on soil types,water Future Expansion
❑ Soil ta.le .nd systecondition) 0 Adequate
❑ High water table 'C ow csysre. Ctc1.e- air
❑ Lot size ■' edium J 1-Lor
❑ Lake,wetland,or stream 0 High 0 Inadequate
❑ Drainage 0 System is causing visible
surface discharge.
COMMENTS: A WuiSpS YIPS li(ii S (LS.1lArbee/ -- (_Ed1 '17-144l(S flLflA,lf a Int hF. / 1151)( C'
7-?5-o0 ,4-1,tIL- %Li.' )
Date of Inspection tic System InO' or
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that
this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy
of the system under current conditions based on the available information.
This report must be kept on the premises with system location and pumping records.
WHITE COPY/Inspector's File GOLD COPY/Homeowner
On the North Shore of
Lake Minnetonka
ON-SITE SEWAGE TREATMENT CITY
INSPECTION REPORT OF POST OFFICE BOX 66
ORONO 1335 S. Brown Rd.
Crystal Bay, MN 55323
473-7357
OWNER /�, ADDRESS /zs-44Mi,1s' h
PERMIT NO.'S. / DATES /e7o2 D' CONTRACTORS Ap2m f 542'
City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The on-site sewage
treatment system at the above address has been inspected and appears to fall into the category checked below.
(This is an existing system 0 new construction)
D1 Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating
properly.
▪ 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed,
located, and constructed generally in accordance with previous codes. System appears to be functioning properly;no major
upgrading of the system is required at this time.
▪ 3 Does not meet current City standards in many respects relating to design,construction, or location.Appears to be operating
adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at
this time.
U4 System may or may not meet current City standards for design, construction or location, but is failing to properly treat and
dispose of the current input, and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is
creating a safety hazard,or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/
replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan
must be submitted for review.Your contractor must obtain a permit before work is started.
SYSTEM CONDITION ( 21 Checked items may require your action)
Tank inspection indicates: Al Inspection pipe is located directly over tank baffle.(Does not
❑ Pumpout not needed at this time, give accurate measurement of solids accumulation.) If tanks
❑ Solids accumulation in tanks indicates they should be pump- have not been pumped out within the last three years, they
ed out this year to help prevent future problems, should be pumped out now.
❑ Solids accumulation in tanks is at a critical level. Tanks Drafield inspection indicates:
should be pumped out as soon as possible. L Drainfield is dry,no surfacing evident.
❑ System is discharging to surface. Tanks must be pumped 0 Some evidence of surfacing,not critical yet.
within 48 hours to eliminate surface discharge. 0 Drainfield is saturated and visibly discharging untreated
❑ Inspection risers missing—tanks could not be inspected, effluent to the surface. This condition may require replace-
Inspection risers (4" dia. pipe)must be installed in each tank ment or additions to drainfield. Contact the City Inspector
at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days.
the last three years,they should be pumped out now. 0 Drainfield extent and condition unknown.
SITE CHARACTERISTICS:
Limiting Site Factors Potential for System Failure Site Capabilities for
❑ Slope (depends on soil types,water Future Expansion
❑ Soil table,and system condition) Adequate
❑ High water table Qi Low 0 Fair
❑ Lot size 0 Medium 0 Poor
❑ Lake,wetland,or stream 0 High 0 Inadequate
❑ Drainage 0 System is causing visible
surface discharge.
COMMENTS:
Date of Inspection Septic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that
this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy
of the system under current conditions based on the available information.
This report must be kept on the premises with system location and pumping records.
WHITE COPY/Inspector's File GOLD COPY/Homeowner
CITY OF ORONO 0
Municipal Offices O .41O
Post Office Box 66
Crystal Bay, MN 55323-0066 y\; P' ON—SITE SEWAGE TREATMENT
i
,' Se INSPECTION REPORT
ilk /
9kESHO4
Owner: Pelf{ Lyfk Address: c'rk 2JJ,Pir /I /L Ahl
Permit #'s: 1s21 Dates: ,15—...22.—Sec— Contractors: J /uh 91- 1//'\
City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked below.
(This is„e l an existing system [ ] new construction)
SYSTEM CONFORMITY (1-3):
1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
without discharging any pollutants into ground or surface waters.
2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the
current City Codes, but was installed according to the code in effect at the time of installation, and which
is operating satisfactorily by treating and disposing of the entire current sewage input without discharging
any pollutants into ground or surface waters.
3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any
system which may or may not meet all the location, design, and construction standards of the current City
Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand
between the distribution device and the limiting soil characteristics.
(The limiting soil characteristic [ ] has or [ ] has not been identified at this time. If the limiting soil
characteristic has not been identified, this classification may be subject to revision.)
TANK CONDITION (5-10): S—
Talc inspection indicates:
( f Pumpout not needed at this time.
6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems.
7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible.
8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge.
9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each
tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped
out now.
10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation).
If tanks have not been pumped out within the last three years, they should be pumped out now.
DRAINFIELD CONDITION (11-14): 13
Drainfield inspection indicates:
11 Drainfield is dry, no surfacing evident.
Some evidence of surfacing, not critical yet.
3 Drain '-ld is - -. _•• . - �. - luent to the surfa - Contact the City Inspector
tnme.iate Repairs must be completed within 90 days. s
14 Drainfield extent and condition urittrown.
LIMITING SITE FACTORS (slope,setbacks,etc.):
POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): 4;13
CO NTS• . /A ' /. f �.: I ' II ' A ' // A ' r Ii '
• ► /,,►, a t_
.' # iii r %•�_ Q►. . hr PI ,
C1111117055/01/1PAIMIAridtMMIWrlit, IMPICIIKITIMIGIIIVIMMIM-.. -- 1-1..e.
:OVA f'MtAilMOPPOr
Date of Ins•ection 4-.tic ystem nspector 4K/Ad
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or certify that an existing system will continue to function
properly, but is merely an opinion of the adequacy of the system under current conditions based on the available
information.
This report must be kept on the premises with the system location and pumping records.
WHITE COPY/Inspectors File YELLOW COPY/Homeowner
CITY OF ORONO O
Municipal Offices O
Post Office Box 66
Crystal Bay, MN 55323-0066 1 ON—SITE SEWAGE TREATMENT
�l r INSPECTION REPORT
Owner: ' -rLy#e., Address: //()?J //L%QW
Permit #'s: Ros/ Dates: - ' Contractors: /alfM,I- C1/14,
City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked below.
(This is &an existing system [ ] new construction)
SYSTEM CONFORMITY (1-3):
1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
without discharging any pollutants into ground or surface waters.
2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the
current City Codes, but was installed according to the code in effect at the time of installation, and which
is operating satisfactorily by treating and disposing of the entire current sewage input without discharging
any pollutants into ground or surface waters.
3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any
system which may or may not meet all the location, design, and construction standards of the current City
Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand
between the distribution device and the limitingg soil characteristics.
(The limiting soil characteristic [ ] has or has not been identified at this time. If the limiting soil
characteristic has not been identified, this assification may be subject to revision.)
TANK CONDITION (5-10): /0
Tank inspection indicates:
5 Pumpout not needed at this time.
6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems.
7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible.
8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge.
9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each
tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped
out now.
10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation).
If tanks have not been pumped out within the last three years, they should be pumped out now.
DRAINFIELD CONDITION (11-14):
Drainfield inspection indicates:
11 Drainfield is dry, no surfacing evident.
1 Some evidence of surfacing, not critical yet.
Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately. Repairs must be completed within 90 days.
14 Drainfield extent and condition unknown.
LIMITING SITE FACTORS (slope,setbacks,etc.):
POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): 11 �
corlrl�Ts: Orai to /ihp Q/;c j( ' v� Ti _ d arh' : ,1 cry k e_
se ''qP Y
Date of Inspection -'p.fc System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or certify that an existing system will continue to function
properly, but is merely an opinion of the adequacy of the system under current conditions based on the available
information.
This report must be kept on the premises with the system location and pumping records.
WHITE COPY/Inspectors File YELLOW COPY/Homeowner
gv .,4?---
CITY OF ORONO 0
Municipal Offices O O
Post Office Box 66 �.
Crystal Bay, MN 55323-0066 -1 \ ' ON—SITE SEWAGE TREATMENT
I ,'. 1 & INSPECTION REPORT
t, i' ' Sr,p•
,,C
Pete' kESH04'Owner: ty iito, Address: O6.S i Ah e 1))1,xKAI.
Permit #'s: 25a) Dates: p Contractors: / 1/ /)')'1/9YN 41- y7)1
City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked below.
(This is 5/+l an existing system ( ] new construction)
SYSTEM CONFORMITY (1-3):
1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
without discharging any pollutants into ground or surface waters.
2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the
current City Codes, but was installed according to the code in effect at the time of installation, and which
is operating satisfactorily by treating and disposing of the entire current sewage input without discharging
A any pollutants into ground or surface waters.
(ice "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any
system which may or may not meet all the location, design, and construction standards of the current City
Codes and which is failing for any reason; and an s stem with less than 3 feet of unsaturated soil or s=r.
between the distribution device and the limiting soi c ara - . '� ` _ RIP a.(The limiting soil characteristic has or [ ] has not been identified at his ti If t e limiting soil
characteristic has not been identi ied, this classification may be subject to revision.)
TANK CONDITION (5-10): J
Tan1c inspection indicates:
�5J Pumpout not needed at this time.
6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems.
7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible.
8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge.
9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each
tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped
out now.
10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation).
If tanks have not been pumped out within the last three years, they should be pumped out now.
DRAINFIELD CONDITION (11-14): 42
Drainfield inspection indicates:
Drainfield is dry, no surfacing evident. i 1 n
y1,, ar r '21x1 Arlo c-gr Ad--O S QA 01/PC 1 0W.
Q2J Some evidence of surfacing, not critical yet. *T 7e elms ��
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately. Repairs must be completed within 90 days.
14 Drainfield extent and condition unknown.
LIMITING SITE FACTORS (slope,setbacks,etc.): 4,44-AV.—aek,
POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): 7
COMMENTS• r I ' le 1111 S
owl
Date of Inspection e•' ic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or certify that an existing system will continue to function
properly, but is merely an opinion of the adequacy of the system under current conditions based on the available
information.
This report must be kept on the premises with the system location and pumping records.
WHITE COPY/Inspectors File YELLOW COPY/Homeowner
O O
CITY of ORONO
\,�, V� Municipal Offices
tiS; ``r 1 Street Address: Mailing Address:
$EggO 2750 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323-0066
Owner: P-I-e, Ly-He__ Address: 2065 Webber Hills Rd.
Permit #'s: 821 Dates: 6/22/65 Contractors: Norman & Smith
(This is [)(] an existing system [ ] new construction) .
SYSTEM COMPLIANCE (1-3) : 3
1 Code System: Meets or exceeds current City standards in all respects relating to design,
construction, and location. Appears to be operating properly.
2 Compliant System: Does not meet all current City standards for new construction, but in
most respects appears to be designed, located, and constructed in accordance with previous
codes and is functioning properly.
Non-Compliant System: System may or may not meet current City standards for design,
construction, or location, but is failing to properly treat and dispose of the current
input; and any system with less than three feet of vertical separation between the bottom
of the drainfield and the saturated soil level.
(The saturated soil level [X] has or [ ] has not been identified at this time. If the
saturated soil level has not been identified, this classification is subject to revision.)
TANK CONDITION (5-9) : 5
5 Pumpout not needed at this time.
Solids accumulation in tanks indicates they should be pumped out this year.
7 System is discharging to the surface. Tanks must be pumped out within 48 hours.
8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out
within three years, they should be pumped out and risers installed now.
9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks
have not been pumped out within three years, they should be pumped out now.
(During the last septic tank Maintenance Pumpout the tanks [ ] were or were not confirmed
to be watertight by the licensed pumping contractor. If the tanks were not confirmed to be
watertight, this classification is subject to revision.)
0'INFIELDCONDITION (11-14) : 11
11 Drainfield is dry, no surfacing evident.
Some evidence of surfacing, not critical yet. Repair is not required at this time.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface.
Contact the City Inspector immediately. Repair must be completed within 90 days.
14 Drainfield extent and condition unknown.
POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc. ) : medium
COMMENTS: In order to confirm that your septic system meets Minnesota standards, soil borings
were performed to verify a 3 foot separation between the drainfield and the seasonal water
table. The separation is 0 feet and the system is non-compliant. Repair or replacement of the
septic system is required by 12/31/2001.
43- iR-9-) ,2i -----,0,----1,44-44.----
Date of Inspection S is System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a
transfer of property, this report does not guarantee that an existing system will continue to
function properly, but indicates the operation of the system under current conditions.
Telephone (612) 473-7357 • FAX 473-0510