HomeMy WebLinkAboutSeptic System inspections On the North Shore of
Lake Minnetonka
ON-SITE SEWAGE TREATMENT CITY
INSPECTION REPORT OF POST OFFICE BOX 66
ORONO 1335 S. Brown Rd.
Crystal Bay, MN 55323
473-7357
/ g/fy X'04
14/1//7-6-- ADDRESS // 4/ OL' l'' ysr, l 10
OWNER l, ���N'/C�
PERMIT NO.'S. L, 71' (e0,4-( DATES 7 - "`3 - 7 ? CONTRACTORS :S°"F
City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The on-site sewage
treatment system at the above dress has been inspected and appears to fall into the category checked below.
(This isan existing system 0 new construction)
D1 Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating
properly.
2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed,
located, and constructed generally in accordance with previous codes.System appears to be functioning properly; no major
upgrading of the system is required at this time.
EJ3 Does not meet current City standards in many respects relating to design,construction, or location.Appears to be operating
adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at
this time.
4 System may or may not meet current City standards for design,construction or location, but is failing to properly treat and
dispose of the current input,and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is
creating a safety hazard, or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/
replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan
must be submitted for review.Your contractor must obtain a permit before work is started.
SYSTEM CONDITION ( 121 Checked items may require your action)
Tank inspection indicates: 0 Inspection pipe is located directly over tank baffle.(Does not
•---El Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks
❑ Solids accumulation in tanks indicates they should be pump- have not been pumped out within the last three years,they
ed out this year to help prevent future problems, should be pumped out now.
❑ Solids accumulation in tanks is at a critical level. Tanks Drainfield inspection indicates:
should be pumped out as soon as possible. Drainfield is dry,no surfacing evident.
❑ System is discharging to surface. Tanks must be pumped 0 Some evidence of surfacing,not critical yet.
within 48 hours to eliminate surface discharge. 0 Drainfield is saturated and visibly discharging untreated
❑ Inspection risers missing—tanks could not be inspected, effluent to the surface. This condition may require replace-
Inspection risers (4" dia. pipe)must be installed in each tank ment or additions to drainfield. Contact the City Inspector
at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days.
the last three years,they should be pumped out now. 0 Drainfield extent and condition unknown.
SITE CHARACTERISTICS:
Limiting Site Factors Potential for System Failure Site Capabilities for
❑ Slope (depends on soil types,water Future Expansion
❑ Soil table,and system condition) '—❑ Adequate
❑ High water table — --EI Low 0 Fair
—El Lot size 0 Medium 0 Poor
❑ Lake,wetland,or stream 0 High 0 Inadequate
❑ Drainage 0 System is causing visible
surface discharge.
COMMENTS:
A- tc / '? . ?IL"
Date of Inspection Septic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that
this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy
of the system under current conditions based on the available information.
This report must be kept on the premises with system location and pumping records.
WHITE COPY/Inspector's File GOLD COPY/Homeowner
1 rv. 0.4
oI CITY of ORONO
k„-, ,
,
"�� �y=ti ; �� • .,� Municipal Offices
"'%'`} lv , Street Address:
'Z Mailing Address:
`4kE$H04`' 2750 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323-0066
Owner: S C oA `fie C \C2 i Address: \7 0 wean- Ln
City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below.
SYSTEM CONFORMITY (1-3): I
"CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code.
2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono Municipal
Code but does meet the three foot separation requirement,and which is not failing or an imminent threat to public health or safety.
3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may
or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any reason;and
any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics.
TANK CONDITION(5-10): 5.
Tank inspection indicates:
0 Puinpout not needed at this time.
6 Tank must be pumped out this year (city code requires tanks to be pumped out every 3 years. Tank was last pumped 5-3 O -0 1 ),
7 Solids accumulation in tanks is at a critical a critical level. Tanks should be pumped out as soon as possible.
S System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge.
9 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank at next pumpout If tanks
have not been pumped out within the last three years,they should be pumped out now.
10 Inspection pipe is located directly over tank baffle(does not give accurate measurement of solids accumulation). If tanks have not been pumped
out within the last three years,they should be pumped out now.
D: • IELD CONDITION(11-14): \l
® Drainfield is dry,no surfacing evident.
12 Some evidence of surfacing,not critical yet.
•
13 Drainfield is saturated and visibly discharging untreated eluent to the surface. Contact the City Inspector immediately.Repairs must be
completed within 90 days.
14 Draintield extent and condition unknown.
COMMENTS: S 4 S-t--k 0 oKS 6(C .
•
10 =3—D \ Gh\coa. itatitQ/1",-0„....
Date of Inspection Septic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee
or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available
information.
(76
O
CITY of ORONO
,� ^ �+ 1� ' ti l� Municipal Offices
C.) /7
q -�16 q? ��- Street Address: 5a-a
Mailing Address:
\•4kEE30
/ 2750 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323-0066
To Current Owner: Address: B —1Ci LOc?
City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below.
1
SYSTEM CONFORMITY (1-3):
1 "CODE SYSTEM"An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code.
2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono
Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and
which is not failing or an imminent threat to public health or safety.
3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may
or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any
reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics.
TANK CONDITION(5-7): ).
Tank inspection indicates:
5 Pumpout not needed at this time.
6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years.
Tank was last pumped I - 71. - ).
Make sure septic tanks are pumped through manhole and not through white inspection pipes. This allows for the proper
cleaning. Keep water softner and iron filter discharge out of septic system to prolong life of drainfield. Ask pumper to test
alarm float to verify alarm is still working in your house. The alarm warns owner that septag_e is about to backup into basement.
7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If
tanks have not been pumped out within the last three years,they should be pumped out now.
DRAINFIELD CONDITION(8-10):
8 Drainfield is dry,no surfacing evident.
9 Some evidence of surfacing, not critical yet.
10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately.Repairs must be completed within 90 days.
COMMENTS:
Date of Inspection Septic System Inspector
o °4
_ oCITY of ORONO
.r. =
. ,A lIk1fi1t.q
` (.,_. l./ Municipal Offices
\�t ;'I`,4?;' e�t / Street Address: Mailing Address:
\ ESII 2750 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323.0066
To Current Owner: Address: 170 W tri f Lc - Al
City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below.
SYSTEM CONFORMITY (1-3):
1�'CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code.
2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono Municipal
Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and which is not failing or
an imminent threat to public health or safety.
3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may
or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any reason;and
any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics.
TANK CONDITION(5-7): S
Tank inspection indicates:
L.)Pumpout not needed at this time.
6 Septic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years.
Tank was last pumped 1-1S—OS ).
Make sure septic tanks are pumped through manhole and not through white inspection pipes. This allows for the
proper cleaning. Keep water softner and iron filter discharge out of septic system.
7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If
tanks have not been pumped out within the last three years,they should be pumped out now.
DRAINFIELD CONDITION(8-10): C6
0 Drainfleld is dry,no surfacing evident.
9 Some evidence of surfacing,not critical yet.
10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately.Repairs must be completed within 90 days.
COMMENTS: Mcyv c. cel-- StQ.v,L -)—,i^\(3 10 oiC 0L.
k 0 ---- --)-0 r3 01„, ,(it 66,t-ij..,,
Date of Inspection Matt Bolterman- Septic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee
or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available
information.
Telephone(952)249-4600 • Fax(952)249-4616
www.ci.orono.mn.us