PERMIT NO.'S. 0l20 DATES ?"i') 7 CONTRACTORS Ants- ilacCJk+t_
City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The on-site sewage
treatment system at the above address has been inspected and appears to fall into the category checked below.
(This is s-an existing system 0 new construction)
171 1 Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating
properly.
EJ2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed,
located, and constructed generally in accordance with previous codes.System appears to be functioning properly;no major
upgrading of the system is required at this time.
0 3 Does not meet current City standards in many respects relating to design,construction,or location.Appears to be operating
adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at
this time.
LJ4 System may or may not meet current City standards for design,construction or location, but is failing to properly treat and
dispose of the current input,and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is
creating a safety hazard,or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/
replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan
must be submitted for review.Your contractor must obtain a permit before work is started.
SYSTEM CONDITION ( 21 Checked items may require your action)
Tank inspection indicates: 0 Inspection pipe is located directly over tank baffle.(Does not
❑ Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks
❑ Solids accumulation in tanks indicates they should be pump- have not been pumped out within the last three years, they
ed out this year to help prevent future problems. should be pumped out now.
❑ Solids accumulation in tanks is at a critical level. Tanks Drai field inspection indicates:
should be pumped out as soon as possible. Drainfield is dry,no surfacing evident.
❑ System is discharging to surface. Tanks must be pumped 0 Some evidence of surfacing,not critical yet.
within 48 hours to eliminate surface discharge. 0 Drainfield is saturated and visibly discharging untreated
Eit Inspection risers missing—tanks could not be inspected, effluent to the surface. This condition may require replace-
Inspection risers (4"dia. pipe)must be installed in each tank ment or additions to drainfield. Contact the City Inspector
at next pumpout. If tanks have nofbeen pumped out within immediately.Repairs must be completed within 90 days.
the last three years,they should be p lmpea-out now. 0 Drainfield extent and condition unknown.
SITE CHARACTERISTICS:
Limiting Site Factors Potential for System Failure Site Capabilities for
❑ Slope (depends on soil types,water Future Expansion
0 Soil table and system condition) til Adequate
0 High water table IS-Low 0 Fair
❑ Lot size 0 Medium 0 Poor
❑ Lake,wetland,or stream 0 High 0 Inadequate
❑ Drainage 0 System is causing visible
K have, s face discharge. �►_u i `
COMMENTS: » ✓e. no Leen r►Ny► SI h e- ge- z TTn S
res / 9-7 and s ha-). r. {s
sia lay i ad/dal—Me. Orme oP pvmpJl14.
7-a9-?1 :fes i
Date of Inspection Septic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that
this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy
of the system under current conditions based on the available information.
This report must be kept on the premises with system location and pumping records.
WHITE COPY/Inspector's File GOLD COPY/Homeowner
.:
CITY OF ORONO O
Municipal Offices O L kr‘
Post Office Box 66 = ,
Crystal Bay, MN 55323-0066 a '•� r ON—SITE SEWAGE TREATMENT
t A►i'llF INSPECTION REPORT
ktsxo4
Owner: • 4 I _ Address: ? fi r- E.
Permit AP's: 0/2'3 Dates:, :)"4 7 Contractors: [�h.r1S r;L ackiloP,
City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked below.
(This is 0L an existing system [ ] new construction)
SYSTEM CONFORMITY (1-3): )
"CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
without discharging any pollutants into ground or surface waters.
2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the
current City Codes, but was installed according to the code in effect at the time of installation, and which
is operating satisfactorily by treating and disposing of the entire current sewage input without discharging
any pollutants into ground or surface waters.
3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any
system which may or may not meet all the location, design, and construction standards of the current City
Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand
between the distribution device and the limiting soil characteristics.
(The limiting soil characteristic i has or [ ] has not been identified at this time. If the limiting soil
characteristic has not been identi ied, this classification may be subject to revision.)
TANK CONDITION (5-10): /0
Tank inspection indicates:
5 Pumpout not needed at this time.
6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems.
7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible.
8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge.
9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each
tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped
out now.
Inspection pipe is located directly over tank baffle (does notgive accurate measurement of solids accumulation).
If tanks have not been pumped out within the last three years, they should be pumped out now.
DRAINFIELD CONDITION (11-14): I)
Cyan nfield inspection indicates:
11Y Drainfield is dry, no surfacing evident.
2 Some evidence of surfacing, not critical yet.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately. Repairs must be completed within 90 days.
14 Drainfield extent and condition unknown.
LIMITING SITE FACTORS (slope,setbacks,etc.):
POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): Lobo
�COMEN
MTS: Y.-- . ' _;ftrr if I Al [' g�J \ Vii
beeKAA . /i ' --__Ark Iii- - (1 /Oh
y .
6 ' g 7 a • .1 c✓r t.0 hnntr,P la1 PAN.-1.
______-_-4-29 .1__________1_ A 4 ` ' / i
Date of Inspection eatic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or certify that an existing system will continue to function
properly, but is merely an opinion of the adequacy of the system under current conditions based on the available
information.
This report must be kept on the premises with the system location and pumping records.
WHITE COPY/Inspectors File YELLOW COPY/Homeowner
c0:
CITY OF ORONO O
Municipal Offices O Ator‘
Post Office Box 66 '--
Crystal Bay, MN 55323-0066 '; r Al ON—SITE SEWAGE TREATMENT
40 INSPECTION REPORT
, `�k�sKo4
4;
Owner: 1 Des-itry4-CS Address: a3 /TNI. kr-- /—f' ),
Permit #'s: Dates: �1-- ?5-) Contractors: f .2f5 Rei k
City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked below.
(This is91 an existing system [ ] new construction)
SYSTEM CONFORMITY (1-3): I
"CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
without discharging any pollutants into ground or surface waters.
2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the
current City Codes, but was installed according to the code in effect at the time of installation, and which
is operating satisfactorily by treating and disposing of the entire current sewage input without discharging
any pollutants into ground or surface waters.
3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any
system which may or may not meet all the location, design, and construction standards of the current City
Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand
between the distribution device and the limiting soil characteristics.
(The limiting soil characteristic has or [ ] has not been identified at this time. If the limiting soil
characteristic has not been identi ied, this classification may be subject to revision.)
TANK CONDITION (5-10): 0
Tank inspection indicates:
5 Pumpout not needed at this time.
6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems.
7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible.
8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge.
9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each
tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped
out now.
10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation).
If tanks have not been pumped out within the last. rs, thgx shQulldd be/pump d out now.
' . 171DRAINFIELD CONDITION (11-14): rd.
Drainfield inspection indicates:
Drainfield is dry, no surfacing evident.
1 S evidence of surfacing, not critical et.
Drainfield is saturated and visibly isc a ing untreated effluent to the surface. Contact the City Inspector
immediately. Repairs must be completed within 90 days.
14 Drainfield extent and condition unknown.
LIMITING SITE FACTORS (slope,setbacks,etc.): 4 L„ c—L
POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): !7c 1L
COMMENTS:
/.
Date o nspection ept'c System Inspector
Note: in the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or certify that an existing system will continue to function
properly, but is merely an opinion of the adequacy of the system under current conditions based on the available
information.
This report must be kept on the premises with the system location and pumping records.
WHITE COPY/Inspectors File YELLOW COPY/Homeowner
__
N.
CITY OF ORONO O
Municipal Offices O O
Post Office Box 66 = P
Crystal Bay, MN 55323-0066 , ON—SITE SEWAGE TREATMENT
1K-1
$, y....„,,
,
cs
1,577,,.. �� INSPECTION REPORT
kEsHo
Owner:6/4R bes01r115 Address: 90 ul�nfe 4.4 J, C 6.-..5-350
Permit #'s: /20 Dates: ?/3//97 Contractors: bons fiee/cjk)6
City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked below.
(This is )41.„an existing system I ] new construction)
'SYSTEM CONFORMITY (1-3):
(T
"CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City
�� Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
without discharging any pollutants into ground or surface waters.
2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the
current City Codes, but was installed according to the code in effect at the time of installation, and which
is operating satisfactorily by treating and disposing of the entire current sewage input without discharging
any pollutants into ground or surface waters.
3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any
system which may or may not meet all the location, design, and construction standards of the current City
Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand
between the distribution device and the limiting soil characteristics.
(The limiting soil characteristic X has or I ] has not been identified at this time. If the limiting soil
characteristic has not been identified, this classification may be subject to revision.)
TANK CONDITION (5-10):
Tank inspection indicates:
5 Pumpout not needed at this time.
6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems.
7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible.
System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge.
Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each
tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped
out now.
10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation).
If tanks have not been pumped out within the last three years, they should be pumped out now.
DRAINFIELD CONDITION (11-14): It
id/Wield inspection indicates:`
Drainfield is dry, no surfacing evident.
Some evidence of surfacing, not critical yet.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately. Repairs must be completed within 90 days.
14 Drainfield extent and condition unknown.
LIMITING SITE FACTORS (slope,setbacks,etc.):
POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): in (IA hi
COMMENTS: A) t7 .Sul2PAC;vac? 44l- 11/nt 0� ( S)c= '1/c'1
Date of Inspection 7ptic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or certify that an existing system will continue to function
properly, but is merely an opinion of the adequacy of the system under current conditions based on the available
information.
This report must be kept on the premises with the system location and pumping records.
WHITE COPY/Inspectors File YELLOW COPY/Homeowner
to 0
g%)
CITY of ORONO
1 Municipal Offices
•••1...-!;;;•Aj , Street Address:
�V Mailing Address:
2750 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323-0066
Owner: 4 CS�,r\t5 Address: I
y � We4r n
City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below.
SYSTEM CONFORMITY (1-3): I
cp "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code.
2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono Municipal
Code but does meet the three foot separation requirement,and which is not failing or an imminent threat to public health or safety.
"NON-COMPLIANT NON-COMPLIANT SYSTEM A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may
or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any reason;and
any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics.
TANK CONDITION(5-10): S.
Tank inspection indicates:
Pumpout not needed at this time. r�j' l
6 Tank must be pumped out this year (city code requires tanks to be pumped out every 3 years. Tank was last pumped I ,id—0 Q
7 Solids accumulation in tanks is at a critical a critical levet Tanks should be pumped out as soon as possible. ).
8 System is discharging to the surface. Tanks must be pumped out within 43 hours to eliminate surface discharge.
9 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dib pipe)must be installed in each tank at next pumpout If tanks
have not been pumped out within the last three years,they should be pumped out now.
10 Inspection pipe is located directly over tank baffle(does not give accurate measurement of solids accumulation). If tanks have not been pumped
out within the last three years,they should be pumped out now.
DRAINFIELD CONDITION(11-14): \�
11 Drainfield is dry,no surfacing evident
12 Some evidence of surfacing,not critical yet.
•
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately.Repairs must be
completed within 90 days.
14 Draintield extent and condition unknown.
COM ENTS: S S S OOKS OK •
-0 1 Ncto,
Date of Inspection Septic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee
or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available
information.
6o \ .
1,7
,s4:-= = CITY of ORONO
^ .,:. tib/ Municipal Offices
\< ,. e ;':'‘.011,// Street Address: Mailing Address:
Egg g-' 2750 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323-0066
To Current Owner: Address: S U \N(-or- L"L
City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below.
/S�YSSTEM CONFORMITY (1-3): I
01 )'CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code.
2.�"COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono Municipal
Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and which is not failing or
an imminent threat to public health or safety.
3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may
or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any reason;and
any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics.
TANK CONDITION(5-7): C
Tank inspection indicates:
l J Pumpout not needed at this time.
6 Septic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years.
Tank was last pumped '71,\—0\ ).
Make sure septic tanks are pumped through manhole and not through white inspection pipes. This allows for the
proper cleaning. Keep water softner and iron filter discharge out of septic system.
7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If
tanks have not been pumped out within the last three years,they should be pumped out now.
DRAINFIELD CONDITION(8-10): 0
CODrainfield is dry,no surfacing evident.
9 Some evidence of surfacing,not critical yet.
10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately.Repairs must be completed within 90 days.
COMMENTS: Ur. c,:tC,t\) a- Sci l-.1_._ ;•k0 k cA... ot \,.to Li
C r.� `vim S C'S Vt...‘',:(1,-'+- i CY�� 's-o Cir A,v L Cts \--f c(.L1< —)0 S'5
C(.5—t-t•— •._C ',rc► i a's- CP.?5 ba, ..V o c,- ,
t d ..-1:1 —o''S Gam— ,,_ M...—_,...
Date of Inspection Matt Bolterman - Septic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer ofproperty,be advised that this report does not guarantee
or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available
information.
Telephone(952) 249-4600 • Fax(952)249-4616
www.ci.orono.mn.us
i
/ O O
r.: CITYof ORONO
'i
\\"$',
i,VMunicipal Offices
a6i+ G % Street Address: g5a-a4q- 160 O
Mailing Address:F :,
' ¢�.
" E880 = 2750 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323-0066
To Current Owner: Address: 3 Li a , r L �J
City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below.
SYSTEM CONFORMITY (1-3): —
1 "CODE SYS I EM"An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code.
2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono
Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and
which is not failing or an imminent threat to public health or safety.
3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may
or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any
reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics.
TANK CONDITION(5-7): �..
Tank inspection indicates:
5 Pumpout not needed at this time.
6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years.
Tank was last pumped -"? 3i ` ('-s( ).
Make sure septic tanks are pumped through manhole and not through white inspection pipes. This allows for the proper
cleaning. Keep water softner and iron filter discharge out of septic system to prolong life of drainfield. Ask pumper to test
alarm float to verify alarm is still working in your house. The alarm warns owner that septage is about to backup into basement.
7 Inspection risers missing tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If
tanks have not been pumped out within the last three years,they should be pumped out now.
DRAINFIELD CONDITION(8-10): / 0
8 Drainfield is dry,no surfacing evident.
9 Some evidence of surfacing,not critical yet.
Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
��immediately.Repairs must be completed within 90 days.
COMMENTS: -n 4 e `, 6/Z I /xi, ✓a '®�� ric t,
rG 0 (,eci c lei.--. �-+�i r°'. eP / - 4 e /3 0 -
tY' 'J *' °A ' , �
Date of Inspection Septic System Inspector