HomeMy WebLinkAbout1998 - 010146 - mechanical PERMIT
CITY OF ORONO PERMIT TYPE:
2750 Kelley Parkway- P.O. Box 66 MECHANICAL
Crystal Bay, Minnesota 55323 Permit Number ;f; x 14;_,
(612)473-7357 Date Issued: 04/28/98
SITE ADDRESS:
2'1-100 WEAR CIF`
jG
P . I . N. : 33-118-23-34-0007
DESCRIPTION:
1 HEATING SYSTEMS CFM 1 ,400 FL lE S 1 2E 4
F JEI NATURAL RAL GA°_ MAKE CARRIER
DEL Wf='tV091 OUTPUT 71 , 000
INPUT 88, 000
1 AIF CONDITIONING HORSE POWER 3 MAKE CARRIER
MON] TRA036 TONS 3
. VENTILATION MAKE 1_K Ti:H.i BATH i MODEL _-LA NDRY
REMARKS:
FEE SUMMARY:
VALUATION $9, 315
Bacle FeP $116 . 44 MAIL IN $1.-F;(.2
Surcharge_ aa�' Total ree $122 .60
Subtotal $121 . 10
CONTRACTOR: - Applicant - OWNER:
DITTER INC: 34789558 A t TIO VELUi='t•1FNT
;_,fit;; TOWER RCS 7900 WEAR C:I R
t1EDINA MN =."_40 ORONO MN SS:735E.;
(612) 478-9558 X 75-9 0
THE UNDERSIGNED HEREBY REQUESTS PERMISSION TO MAKE THE REAL IMPROVEMENTS
SPECIFIED AND AGREES TO DO ALL WORK,: IN STRICT COMPLIANCE WITH ALL CITY OF
L_ ORONO ORDINANCES AND STATE OF MINNESOTA BUILDING CODE REQUIREMENTS . J
o Asee, inktee4)
APPLICANT%PERMITEE SIGNATURE ISSUED BY:SIGNATURE
WOOD BURNING EQUIPMENT
Wood stove with flue
Wood combination or add-on
Factory fireplace with flue
Factory Fireplace (s) Freestanding Masonry
Wood Stove (s) Franklin, other
Brand Name Model No.
Mfgr's MM., Clearances, side , rear , min. flue dia.
VENTILATION
No. C Kitchen Exhaust V ducted recirculating cfm
No. 3 Bath Exhaust (must be ducted outside) cfm
No. Other Fans: Locations L'' -`f� cfm
FUEL STORAGE (MUST BE APPROVED BY FIRE MARSHAL)
Installation Removal
Fuel oil: gallons underground inside outside
LP Gas: gallons
Other Gas opening
PERMIT FEE CALCULATION
1. 1.25% of Contract Price* or Minimum Fee ($35.00)
x .0125 $
(contract price)
2. State Surcharge. ** Add the State Building Code Division
Surcharge to each permit. x .0005 $
or $.50, whichever is greater (contract price)
3. Postage and Handling (Only mail-in applications) $ 1.50
4. TOTAL PERMIT FEE (Add lines 1-3 above) $
* CONTRACT PRICE or JOB COST means the actual or estimated dollar amount charged for the permitted
work including materials, labor, profit, and other fixed costs. It is the amount to be charged to the
customer for the work done. If any material, equipment, labor, or installation are furnished by the owner,
tenant or any other party the reasonable market value of such items must be added to the estimated cost
or contract price for permit fee purposes. In the event that there is a dispute on the amount of the job cost,
the City may request the submission of a signed copy of the actual contract.
** The STATE SURCHARGE is .0005 of the contract price under $1,000,000 or $.50 - whichever is
greater. For valuations over $1,000,000 call the Department of Inspectional Services for the price.
The undersigned hereby applies to the City for issuance of a Mechanical Permit, agrees to do
all work in strict accordance with the ordinances of the City and the regulations of the Minnesota
State Building Code, and certifies that all statements made on this application are complete, true
and correct.
A IF
Applicant's Signatu e: � /,���-/ �4, Date: /743
Approved By: Date:
4b Lr �✓
CITY OF ORONO APPLICATION FOR MECHANICAL PERMIT
Box 66 (2750 Kelley Parkway)
Crystal Bay, MN 55323
GENERAL INFORMATION
1. You may apply for mechanical permits by mail or in person at the City offices. Applications will be
reviewed and a permit will be issued within 2 working days.
2. Permit cards will be sent by return mail after a review is completed. PERMITS ARE NOT VALID
UNTIL YOU RECEIVE A PERMIT. WORK MUST NOT BEGIN UNTIL THE PERMIT CARD IS
POSTED ON THE JOB SITE.
3. Mechanical Designs - Complete calculations, details and specifications are required for each heating,
ventilation, humidification-dehumidification, and air conditioning installation including heat loss/heat gain
calculation, design temperatures, equipment ratings and identification as to type, manufacturer and model.
Data shall be presented on form provided. Identification of and specifications for water heating equipment
shall also be provided.
4. When any new construction or remodeling is involved, a separate building permit must be obtained.
5. All work must be done in accordance with the Uniform Mechanical Code/State Building Code
requirements.
6. All work must be inspected (rough-in and final). Call 473-7357. 24-hour notice required.
7. House Heating Test Record must be submitted before final.
Instructions Complete all items on this application. Compute the permit fee. Sign and date the certification.
INCOMPLETE APPLICATIONS WILL NOT BE PROCESSED. If you have questions, call 473-7357.
Please check one: New Addition Repair Replace
Residential . Commercial
JOB SITE: 2g#617/.,„(16-3-A‹ ('Of Zip:
Owner's Name: ;' ,l)pJ //Pi- Telephone Number: 'F7J='1foO
Mailing Address: 3(p *Jai Sv t /iV City: u/ Z Zip: 5,)3q/
Contractor's Name: /AlXa2 Tvc_ Telephone Number: 478.-q.17`-1
Mailing Address: City: .P,(_ Zip: 7Hv1
SYSTEM DESCRIPTION
HEATING SYSTEMS
Quantity: /
Make: co '
Model: 4/A//Dq l iG4�'
Fuel: /t/ o
Flue Size:
Input BTUs: A
Output BTUs: "lie M
CFM: / i
COOLING SYSTEMS
Quantity:
Make: .Wi�JC..
Model: 136
Tons:
H. Power •
A&T DEVELOPMENT
HVAC LOAD ANALYSIS
for
A&T DEVELOPMENT
2900 WEAR CIR.
ORONO, MN.
Carrier
R HVA(Residential and Light
Commercial HVAC Loads
Prepared By:
DOUG BJORK
DITTER INC.
820 TOWER DR
HAMEL MN 55340
478-9558
4-10-98
RHVAC-Residential&Light Commercial HVAC Loads Program • Elite Software Development,Inc.
Ditter, Inc. A&T DEVELOPMENT
Hamel,MN 55340-9691 4-10-98 Page 2
Total Building Summary Loads
Component Area Sen. Lat. Sen. Total
Description Quan Loss Gain Gain Gain
3D Window Double Pane Low Emit Wood Frame 377 12,522 0 8,865 8,865
11E Door Metal Urethane Core 63 1,101 0 282 282
12H Wall R-19 + 1/2" Gypsum Board(R-0.5) 2,032 11,217 0 2,878 2,878
15G Wall 5' or More Below Grade 8/12" Blk+R-11 1,268 5,016 0 0 0
161 Ceiling R-44 Insulation 2,180 4,613 0 2,206 2,206
21A Basemt Floor 2' or More Below Grade 2,180 4,813 0 0 0
Subtotals for structure: 8,100 39,282 0 14,231 14,231
Active People: 6 0 1,380 1,800 3,180
Inactive People: 0 0 0 0 0
Appliances: 0 0 0 1,200 1,200
Lighting: 0 0 0
Ductwork: 0 4,911 0 816 816
Infiltration: Winter CFM: 308.8, Summer CFM: 185.3 440 31,255 2,260 4,077 6,337
Ventilation: Winter CFM: 90.0, Summer CFM: 50.0 0 9,108 610 1,100 1,710
Sensible Gain Total: 23,224
Temperature Swing Multiplier: X1.00
Building Load Totals: 84,556 4,250 23,224 27,474
Check Figures
Total Building Supply CFM: 1006 CFM per square foot: 0.231
Square feet of room area: 4,361 Square feet per ton: 1,735.086
Building Loads
Total heating required with outside air: 84,556 Btuh 84.556 MBH
Total sensible gain: 23,224 Btuh 85 %
Total latent gain: 4,250 Btuh 15 %
Total cooling required with outside air: 27,474 Btuh 2.289 Tons (based on sensible + latent)
2.513 Tons (based on 77% sensible capacity)
Notes
Calculations are based on 7th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
Wednesday,April 22, 1998