Loading...
HomeMy WebLinkAbout1987 - Septiic System SEPTIC SYSTEM INFORMATION STREET ADDRESS 2.42),-/r AJEAiQ C LOT BLOCK 2 SUBDIVISION 41.1./ Meakteh.ot ZAJaAtD MONTH AND YEAR TESTING DONE ITEMS ALREADY COMPLETED (p SOct.... „olC.lNGaS Peat rt,s7rs fcrew. teSI / 9d. !o NEED TO COMPLETE BEFORE ISSUING BUILDING PERMIT: OBORINGS 0 PERC TESTS OSYSTEM DESIGN SITE PLAN ID OTHER 0. COMMENTS 1401,f1,1 4 tem eOnt < ti"W S DATE THIS SHEET FILED /0-31 -8C? BY 44#124. SUBDIVISION FILE NO. )/6)/ :-....;•-•:--:-...--i, 1-:::.•-.1 ,,,:<•.••=•..,;••••.7.7,.,..,•-.1 .-,:•"•=•..:•A . . . . . 1 1 1 -• • .• • ' • t ,-Norne of The south 22.00 saes of The SE Ve-of the SW to.of Sec.33,1*.US,17.23 31 3/ I , --•1326.12 589'IT 23"E-- 416.1 (-North line -... 4. i • • ------ a.-50.00-" ' * 340.13 II .1 .8 2 (c331 iiir • - ..si._r.2 o-- 1 11A 7..] u Iv Ls-441 ....-..-1 ..: 1 i.e.: I* 71-1 I 17. 2 ---- ti 0 ,.! ,, • .., IR. :tocici rd-7.s"° it I _-;., • .1 ,; , IN WS t 41 1;4 ell ...'':•''' 0 ti: e6 c.. I z i I i?t,' Li 00 .515;i1ZI, ...-->,.0..- CC co' . I I z be 10'24'41. ......- •0 I_ ____415•81 _ kJ I rs 17 Im. I V 131C .....--":„... nn. ;=- I I 4' -----'5% .,2-- n N 89°IT 23W 1 I 4)62 I.," N.,------ 03 0-1 • 1 ;..1.1 9,, L._t. __340.13 j ic./ I .4. a ouTLOT-311.81 5 89•1173-E--- -'4::ta al, -0; ; I ..... • • . • . :...„ A segkeol.,Jig olly itZ.= 2 i j, •• I I L ‘ -..4-41.81 N 89•n•23"W.-- -..1.1.://4.4.1 • . . . z 1.4 4 -•••• 22 00 89°11' " -/ `.. 41 a oz r--1,71-2ff.-.-8,3----, .1- 5 i N.,,t.Zr3!ft r--„. sa • " ., . .. -, .... • IF- el- (7.'I 0 I 0 IS 1 I Z = ''•'- , . - .. , .. • • ••- I I ; I PI lits 1 ihe 54 4.4 the sv.14,124,33 to-1 ... Whet(' u --t r-i ,-.„. , \ 02t00-.. I sn ,n -zt • w isl I 2 I la 1-2 I 1,1.1. \ , I 40, ,1 t‘ii i- to I r ,...,, ._- . ,....- .\\ 3 id 1 , = ,--, .5 ,i, s i_oz i -o i,- Ilmfgo/.64./c NerIS'oerw 125.-9-4..5-".:. --11.37.f"--7td I ••D 17 A . •.- ,•-• ......-; ..,. 13' .!-..t-9-VE.. Zr_Ki -reS4":r\** 1,/. lag: I I : I g r,s4 vs ,T,_ w)..4 I i I t.....1 it5;ifi I (1).:(1 i--ti.:i al • 3 . ..) Z.a !I:1. \ -‘?";.E., -•-•,,, A....---/i ,-• • no Z •,=,•,.. si: Z I. may va dooinons osoo.ont-•--14 . \-... •1• :117. '--/ /"'o a. `- 7 i ) 1\ I ›- :- }..,f, * i tpol‘i......s•-^ 0 .t.,„- ,r/ ... ,., ,:- , 1 c, / \ ... ..,/ so .1••••,/ a / ,... :1-- .... .- Lei i 1 Is •• N-- • * / `'"\ sv••••`'" . ',.,•,- nzt-/0 ,ge,1•• , ez • • ,,..44 1 -...., / \ J I i!,74.9, / ,; lig,,R 1.1/ 'Is- ..7•-'. ,/4 • 1 I___-.6 286.00 1,3-1 ..... 7...7 ,5 I.---4:.(4.s..0 •--- IL'. 387.01 N89•11.23 W \-51. ‘E' I ,,-5.E.corner ef The SW go.of . - . •:-. •'.. '4433%2--------- 5f:1.00 _____--J -o- 1,-- -------..• At/11 13 / S44.13,1,1,2 R.23(tionn.fesiummonf) WATERTOWN "1 i'st..---33.00 .1 WATERTOWN --‘8432 N89.17.23"Wa- ROAD * n07r,1 .rFriNqr-i T3 0O z WATERTOWN ROAD r. 11 WATERT.,WN • • ......• - ----..' ..• • RCAC: ,.. -- = th,,,vr,rcictivu_....04.41 N81*n•23...N..- R°to:: 2 _.: 2 . __.,:-..r:I.A.ff. . -.... . .__4,20.01 N89•11.23..W..- 2 _. At',I Edi(-qt..: '"r-11..IA CI :-......7‘.7`..':::','....-fr,_: .::7,•:-..-,-, " I-- .., -......Soo4h tint of the SW Iloi or Set.33,TAB,R.23T- •" CiDUNTP' '- • - - ,• .sls.•::......r. • •.-- -, -. re.,z it: c•••, i-V.iE:. ::-.....:_i ED i . Ni.. 230 gLi 1 RC',1..!_:11 0 MEADO.V•1:-3 I AUD. SL!!BD. ND. 230 4.. RA A.t,1•••t..: noi,!;•, .2 , 1 .0...,.•.••s e....•, :: , I 'r)- ADD. 9 •=ii . . Utility and drainage easements shown thus: . , II IIa Denotes Iron monument s.o--1-- BEARINGS SHOWN ARE ASSUMED -Th-5.0 I I " I . si I I JJ_L. ..-_;•••;',,..,--•:-.:......•,:-....,•-:"i,,:•,1 1 1 100 0 100 200 -. • . • ••. , meneweelo. i SCALE IN FEET Being 5 feet in width, unless otherwise I indicated, and adjoining lot lines, and 10 Ii feet in width and adjoining street lines as shown on the plat. I i I ALL-METRO LAND • • S-P TESTING, INC. • • • • • 961 KATYDID LANE ST. MICHAEL, MN 55376 • • 497.3668 STEVE SHIRMERS September 22 , 1987 Wear Partnership • • Lot 3, Blcok 2 Orono, Henn. Co. , MN. • • This system is designed for a Type 1, four bedroom home and in accordance with the Minnesota Pollution Control Agency standards WPC 40 and local ordinances. The soils on this site. are typical of SCS soils mapped - LrB - Lester loam. A seasonally high water table was located at 16" , 20" , & 24" , (mottling) . Due to the seasonally high water table, a pressurized mound system will need to be installed. The bottom of the rock bed must be located at least 3 ' above the seasonally high water table. The soils at a depth of 18" have a percolation rate averaging 10 . 4 min/inch and are adequate for treating septic effluent. A pumping chamber Will need to be installed to lift the effluent to the treatment area. The manifold and supply line pipe must have back drainage to the pumping chamber. The distribution pipes shall have their ends capped. Be sure the rock and sand fill material are clean. The sod layer below the entire mounded area must be turned over, just break up the sod, be sure not to over work. , The power supply and switches must be located outside the manhole and pumping chamber in 'a weather proof enclosure. A warning device must be installed with a light and sound device, this is in case of a pump failure. (Mercury floats are a good method) . All neighboring wells are :located more than 100 ' away from the proposed treatment area. • Keep all heavy equipment Off of the proposed treatment area before and after construction as' mucI as possible. The treatment area should be marked off before construction. With proper installation and maintenance, this system should have no problem in treating septiq effluent effectively. It is recommended that the septic tanks be pumped every 2 years . (53 Soil and Percolation Tests 57;A)---- Steven B. Schirmers Septic System Design • SBS/ds . - , - .. - . . .� .....Se s...—v w a./`.1... r_ — — — —— — —— — —i I • P o'os c .t4o�sc iooc,i x�`� c l At . aaV., -11-z5 >// se ') 't-'S M a-TtL 1 r. L 3 Ce '/ 4C5ooZ 7 01,T o /000,7-) ' ci`c,+o kre TF11--XV-s q � % I TBM� /OA.1.7,-,) 4• .fix amt _ _ — • n Y99. — 01 �� ��c�o� I �5�3 30' l r6 3 I�_998,6J� 1.,,,,",„„A LH YFm Q E er . ... • ni i I 9n. ' X— �*' �� I o • �L\ \99�5� — - 1 SaPP�-r L1i-+F t'r-o s o..v:-.-:-..., ikj - • . . . - . a . -tATl'F--NT 990.9 t 1, _.44t - *.. l 996,0 • • 30' M So' az' ys-� yy'` /O6 KEEP ALL NFrcVY EQvlPMEA/T oFr OF TWE 7 TREA rMEi•LT AREAS Ark DR AND AFrLF C- coN.5rRvcTto,V ��vt o sac c- t y . c-,c-. use-req,-tc GI�EGK UAIf�ER4kOU/1D VT-it/TIES I _ / - - . AL I. / . • / • S Percolation Tests Scale: / 5 C.,/ ! PROPERTY OF: WEA f! PA 1 N E FSI l i 7'l�tt'1 /.:5- /ROA! /4A R k'/fLi G XSoil Borings G 07a , "./.:./..,:-... is. 2 PROPz-A rr COR/IP As 2cvt!1@• Bench Mark /",^,e-"0/1-/.") J'!/ ', i-;.( `/h' .C.,(1.1.1—E1— /00% 1 Note: This system is to be constructed to meet - the Minnesota Pollution Control Agency S-P TEST/NG/NG Standards -WPC 40 a Local Ordinance Designed By: :7,-L.,--. v. � • t,. , --- Date:3., ..S PH.612-497-3566 i . NNNN..NNN: _ n LI. v;.0. 4.`� , F�L� rcoe. _1-4 7o S °)o • SET- BACKS \y ' to� ,1 RLL - • - - - • - - HOUSE System • _ 1 must be - • Tank from, property lines • X- -�;a `- w L4TYr 2 from wells ac from b!dgs. "Yg Treatment area ='from lakes , strea f s- - - - - - - • Treatment areas ' from property lines NOTE: Power supply and switches trust be located in a , Mat-�►fo�s rnq �" 'from wells weather proof enclosure outside the pumping chamber and manhole (3RLCFeLL st:..'from bldgs. , ►- -i • 1.^_ from trees SOIL BORING ELEVATIONS �, _min. I- I' ."dia.s TH:I EL.-9 - J%, 99G -g / . grade 4%TH• 2EL.-r.9 o - Tank Tank TH.'3 El---2.=� Drop to Tank PRESSURE DISTRIBUTION MOUND SYSTEM TH74 EL.-Mg1 • Min. I"to 8' Pumping TH.`5 EL-' 'L3 Max.Into 41 ' p -r o.AY,5 SI•kt..N.1-00J Chamber - - ELEVATION of PROPOSED PUMPING 4"to 6"dia.pipe CHAMBER- 94�..S- SYSTEM DESIGN -MOUND Pcc Po se q 1}c i-� �. )Cc . C • I TYPE-..7... , BEDROOM , Average percolation rate ^•` min./inch (design.83 sq.ft treatment area per gal. of daily sewage flow) - - .L.. -gal./day x.83sq.ft/gal,yt.L.sq.ft-of treatment area +10°/0 = sem_sq.ft. (= 10ft.width 1--..1-,..-J__.ft.Iength of bed area+side slope run y to I x heig = " ft.x�'- ff,lawn•area needed) ' Clean rock needed-.61-Y7 c� sq.ft.treatment area x/. ' depth of rock=__.;', '-cu.ft-- = P'27 cuyds,(3/4"to 21/x`dia. ,includes 2'.of rock above pipe) I ' ' ' • - - - - Clean sand fill below rock needed " I O cu_yds- approx. , sandy loam back fill - ) a.t_yds.approx., topsoil 6" --<a e;uyd. Pc'r--, 4"...-A1\D >>=-`' ' a;2. ' Number of tanks required a _, Ist tank-' gal. , 2nd tank gal.minrrnms PLLS s PU P‘ , � -,�, g-1t+,a. ee ' l Pumping chamber capacity- 25% of daily sewage flow of ' gal.= c gal.+reserve storage off'750./bedroom= gal.+pipe bock droinoge— of /e,�gd./100 knit.of "dia. supply pipe, lin.ft.needed O , __gal.+manifold l ' gd-/IOOlirtftof_"dia.pipe, In.ftneeded Z , g°I PROPERTY OF lA> v�,r Pf?�-C��s Step 1_A-c- ? C\--Y-• a total capacity needed ', `""� gal.(plus area for pump) us E m,r./c c c oho,1,«ID_ - C iv)•--I ;) 1'1 t-'- - 4. 5--\9-� (d Distribution pipe ://;°dia. , 15 .lin.ft, 'ry dia. perforations ` "apart Pump size I hp. (pumpable rapacity gal. 4 cycles/day) w---A--,-_-, \ a.' 1�t;a F c ,c i S-P TEST/NG Iry . Note: When constructing bed - , this area should be shaped Note: Distance from treatment oro to neighboring wells— - 7`, __ to divert run-off from entering treatment area. : L-rt `' � 'L}. %� Designed By: _, - '- • ( Dote.3/ /� , PH. 612-497-3566 • • L-13 CERTIFICATION # 006.27 Logs of Soil Borings Location or Project, Lot 3 , Block 2, Wear Partnership Borings made by S-P Testing, Inc. Steve Schirmers Date 9-15-87 'Classif iction System: AASHO • ; USDA-SCS X ; Unified ; Other Auger used (check tWo) : Hand X , or Power , Flight , or Bucket X Depth, Boring number 1 Depth, Boring number 2 in in feet Surface elevation 998. 8 feet Surface elevation 1001. 0 0 - Topsoil very dark brown Topsoil very dark brown 0 - 1' loam 0 - 1 ' loam 1 - 1 - Dark brown loam 1 ' 4"-mottling Dark gray loan. 1 ' - 1-1/2 ' 1 ' 1 ' 8" 2 ' -mottling Brown clay 2 .- 2 - 1-1/2 ' - 2 ' 2" loam Gray brown clay loam Olimay 2 , 2" _ 2 ' 8" bronam 3 - 3 - Dark olive brown silty clay • 2 ' 8" - 3 ' 4" loam 1' 8" - 3 ' 8" • • 4 - 4 - Olive brown loam Olive brown loam 5 - 5 - 6 - 3 ' 8" - 6 ' 6 - • . . 3 ' 4" - 6 ' 7 - 7 - • 8 - 8 - • • End of boring at 6 feet. End of .baring• at. • 6 feet. Standing water table: . Standing water table: present at feet of depth, present at feet of depth, hours after .boring. hours after boring. Not present in hole ' X . Not present in hole X • • Mottled soil : Mottled soil : Observed at 1' 47feet of depth. Observed at 2 ' feet of depth. Not present in hole • Not present in hole Comments: Comments: L-13 CERTIFICATION # 00627 Logs of Soil Borings Location or Project Lot 3 , Block 2 , Wear Partnership Borings made by S-P Testing, Inc. Steve Schirmers Date 9-15-87 'Classifiction System: AASHO • ; USDA-SCS X ; Unified ; Other Auger used (check two) : Hand X , or Power , Flight , or Bucket X Depth, Boring number 3 Depth, Boring number 4 in in feet Surface elevation 998 . 2 feet Surface elevation 979 . 8 .p. - .• 0 - Topsoil •very dark brown loan Topsoil dark brown loam 0 -. 10" 1 - Dark 10" - 'i , 2" browrl►oamay , 1 0 - 1 ' 2" Bro n „ rown day �oaml 2 -. 1' 8"-mottling c�ay �oam 1 ' 2" - l ' 8"-mottling 2 Olive brown clay loam 2 - Olive brown clay loam 1' 8" - 2 ' 10" 3 - 3 - 1' 8" - 3 ' 2" Olive brown loam 4 _ 4 - Olive brown loam 3 ' 2" - 4-1/2 ' • 5 - 5 - Rusty gray loam 2 ' 10" - 6 ' 6 - 4-1/2 ' - 6' 6 - • • 7 - 7 - 8 - 8 • End of boring at . 6 feet. End of boring at 6 feet. Standing water table: Standing water table: present at feet of depth, present at feet of depth, hours after boring. hours after boring. Not present in hole x Not present in hole X Mottled soil : Mottled soil : Observed at1 ' 8'; feet of depth. Observed at s" feet of depth. Not present in hole Not present in hole Comments: Comments: • L-13 CERTIFICATION # 00627 Logs of Soil Borings Location or Project Lot 3 , Block 2, Wear Partnership Borings made by S-P Testing, Inc. Steve Schirmers Date 9-15-87 • ' Classifiction System: AASHO ; USDA-SCS X ; Unified ; Other Auger used (check two) : Hand X , or Power , Flight , or Bucket X Depth, Boring number 5 Depth, Boring number 6 in in feet Surface elevation 997. 3 feet Surface elevation 999 ' 9 9- - Topsoil dark brown loam 0 - 0 - 6" Topsoil dark brown loam Dark6" - 10" brown �oa�i 0 - 10" 1 - 1 - l ' 4"-mottling Brown clay Brown 10" - 1' 2" loam 10" - 1 ' 8" loam Brown c_lay loaml ' 2" - l ' 8-mottling 2 2 - Olive brown clay loam Olive brown clay loam 1 ' 8" - 2 ' 10" 3 - 3 Olive brown silty clay loam 1' 8" - 3 ' 10" 2 ' 10" - 3 ' 10" 4 - 4 - Rusty olive brown loam Rusty olive brown loam 5 - 5 - 3 ' 10" - 5 ' 4" li Gray brown silty loam 6 - 3 ' 10" - 6 ' 6 - 5 ' 4" - 6 ' 7 - 7 - • • 8 8 - End of boring at 6 feet. • End of boring at 6 feet. Standing water table: • Standing water table: present at feet 'of depth, present at feet of depth, hours •after•.boring. hours after boring. Not present in hole X ' Not present in hole X Mottled soil : 0 Mottled soil : Observed at 1 ' 4" flet of depth. Observed at 1 ' 8" feet of depth. Not present in hole - Not present in hole Comments: Comments : PERCOLATION TEST DATA SHEET Steven B. Schirmers 9-16-87 10 : 25 �� Percolation test readings made by no raw, starting at p.m. , Lot 3 ,Blk. 2•,Wear Partnershl 1 9-15-87 Test hole location ,HoLC numb.r ,Date hole was prepared • Depth of hole bottom 18 inches,Diameter of hole 6 inches Soil data from test hole: Depth,inches Soil texture 0 — 12" Topsoil very dark brown loam 12" — 18" . Dark gray loam Method of scratching sidewall• Knife • Depth of gravel in bottom of•holr 2 inches• • 9=15-87 1 . 0 m 12 Date and how of initial water filling ,Depth otial water filling inches above hole bottom Automatic siphon Method used to maintain at least 12 inches of water depth in bole for at least 4 hours ,Maximum water depth above hole bottom during test 6 inches Time Percolation • Time interval, Measurement, Drop in water rate, Remarks minutes inches level,inches minutes per • inch 10 : 10 prefill 6 10 : 25 10 : 55 . " 4-7/ 8 6 . 2 30 min 11 : 03 11: 33 " 4-9/1.6 6 . 6 " 11 : 44 , 12 :14 4-3/ 8 . 6 . 9 " • Percolation rate 6 . 6 ' minutes peat inch. • PERCOLATION TEST DATA SHEET Percolation test readings maw by Steven B. S c hir m e r s on 9-16'-87 'sing at 10 : 2 6 (400 Lot3 ,Blk.�2 , Wear Partnership 2 9-15-87 Test hole location ,Hole number ,Date hole was prepared—_ • Depth of hole bottom 18 —inches,Diameter of holy 6 inches Soil data from test hole: Depth,inches Soil texture • 0 — 12" • Topsoil very dark brown loam 12" — 18" Dark brown loam . • • Method of scratching sidewall Knife ' Depth of gravel in bottom of holy 2 inches 9-15—'87 1 . 00 .m. 12 Date and hour of initial water filling ,Depth or initial water filling inches above hole bottom Method used to maintain at least 12 inches of water depth in hole for at least 4 hours Automatic s i p h o n • ,Maximum water depth above hole bottom during test 6 inches Y — Time , Percolation Time interval,• Measurement, Drop in water rate, Remarks minutes, inches level,inches minutes per inch 10 : 10 prefill 6 10 : 26 10 : 56 • 4-5/8 6 . 5 30 min 11: 04 11: 34 . 4-3/ 8 6 . 9 II " 11 : 45 12 : 15 , 4-3/ 16 • ' 7 : 2 ' II " • • • .4 • 1 Percolation rate —...6- 9 minutes pet. inch. • • • PERCOLATION TEST DATA SHEET AMINO Percolation test readings made by Steven B. S c h i r me r s �n 9—16—8 7 starting at 10 : 2 7 wwo Lot3 ,B1k. 2 ,Wear Partner ��ip 3 9-15-87 Test hole location ,note Dttmbcr ,Date hole was prepared Depth of hole bottom_ 18 inches,Diameter of hole 6 __inches Soil data from test hole: • Depth, inches Soil texture 0 — 10" Topsoil very dark brown loam 10" — 14" Dark brown clay loam 14" — 18" . Brown clay loam Knife Method of scratching sidewall Depth of gravel in bottom of hole 2 inches 1 : 00p.m. Date and hour of initial water filling 9-15-87 Depth of initial water filling 12 inches above hole bottom Method used to maintain at least 12 inches of water depth in hole for at least 4 hours_Automatic siphon • ,Maximum water depth above hole bottom during test 6 inches Time • • Percolation Time interval, • Measurement, Drop in water rate, Remarks minutes , inches level,inches minutes per inch 10 : 10 prefill 6 10 : 27 10 : 57 • 3-7/ 8 7. 8 30 min 11 : 05 11 : 35 3-3/4 8 . 0 " 11: 46 12 : 16 • • 3-11/ 16 8 . 1 II " • • • Percolation rate = 8 • 0 minutes per inch. • • PERCOLATION TEST DATA SHEET • Steven B. Schirmers 9-16-87 10 : 28 AIIMIP Percolation test readings made by on starting at Test hole location Lot 3 ,B l:k. 2 ,Wear Pa r t n e r wumber 4 ,Date hole was prepared 9-15-87 Depth of hole bottom_ 18 inches,Diameter of holr 6 inches Soil data from test hole: Depth, inches • Soil texture 0 — 14" Topsoil. dark brown loam 14" — 18" Dark brown clay loam Method of scratching sidewall Knife Depth of gravel in bottom of hole 2 inches b. Date and hour of initial water filling 9-15-87 ,pepm of initialwater filling 12 inches above hole bottom Method used to maintain at least 12 inches of water depth in hole for at least 4 hours Automatic siphon 6 Maximum water depth above hole bottom during test inches Time • Percolation Time interval, Measurement, Drop in water rate, Remarks minutes, inches level,inches minutes per inch 10 : 10 prefill 6 10 : 28 10 : 58 1-3/ 4 17 . 2 30 min 11: 06 11 : 36 " 11 : 47 12 : 17 , II " • • Percolation rate = 17. 2 minutes per inch. I PERCOLATION TEST DATA SHEET a.m.,...)Percolation test readings made by Steven B. Schirmers nit 9—16—8 7 starting at 10 : 2 9 p-m. Lot3 ,B1k. 2 ,Wear Partnership 5 9-15-87 Test hole location ,Hole number ,Date hole was prepared Depth of hole bottom 18 inches,Diameter of hole 6 inches Soil data from test hole: Depth, inches Soil texture 0 — 6" Topsoil dark brown loam 6" — 10" Dark brown clay loam 10" — 18" Brown clay loam Knife • • • • Method of scratching sidewall , Depth of gravel in bottom of holy 2 inches . 9-15-87 • 2, 00 .m. 12 Date and hour of initial water filling , epth al initial water filling inches above hole bottom Method used to maintain at least 12 inches of water depth in hole for at least 4 hours._Automatic siphon • ,Maximum water depth above hole bottom during test 6 inches Time Percolation Time interval, . Measurement, Drop in water rate, Remarks minutes inches level,inches minutes per • inch 10 : 10 prefill 6 10 : 29 10 : 59 1-7/ 8 16 . 0 30 min 11: 07 _11 : 37 1-3/4 17 . 2 " 11: 48 12:18 • i I Percolation rate = 16 - 8 minutes per inch. J • . PERCOLATION TEST DATA SHEET Percolation test readings made by Steven B B. S c h i r me r s on 9—16—8 7�tarting at 10 : 3 0 ® Test hole location Lot 3,B 1 k. 2 ,Wear Pa rtne r,tbleliumber 6 ,Date hole was prepared 9—15—8 7 Depth of hole bottom 18 inches,Diameter of hole 6 inches Soil data from test hole: Depth,inches Soil texture 0 — 10" Topsoil dark brown loam • 10" — 14" Brown loam 14" — 18" Brown clay loam Knife Method of scratching sidewall Depth of gravel in bottom of hole 2 inches 1: 00p.m. Date and hour of initial water filling 9-15'87 ,Depth of initial water filling 12 inches above hole bottom Method used to maintain at least 12 inches of water depth in hole for at least 4 hours Automatic s i p h o n ,Maximum water depth above hole bottom during test 6 inches Time . Percolation Time interval; Measurement, Drop in water rate, Remarks minutes inches level,inches minutes per inch 10 : 10 prefill 6 10 : 30 11 : 00 4-3/8 6 . 9 30 min 11 : 08 11 : 38 , " 11 : 49 12 : 19 " " " " " • • Percolation rate = 6 . 9 minutes per inch. • -PERFORATED - ,r_•_ • LATERALS '�. .•.r.i- _� SANDY LOAM SOIL • � rs- r-�~— •--'� r /,/,,•:,..;5--':',•~'•••' ,'/ /: • ':S; • /: i. J� ' '• LAYER OF STRAW OR • �' % / 7, / >�' MARSH HAY COVERED �.� /, WITH RED ROSIN PAPER Y - .�T. P• IPE FROM PIMP �': z / i �, r /; 077'/' a j ' 3/ „_ 2 '? „ II y/ .1/7 CLEAN ROCK ..�; • '�� �,�y, ���,' , ;” . � /' DIVERSION FOR -/.,/•• SURFACE WATER 6" TOPSOIL �' - / %/ 1. SELECT AS LEVEL A SITE AS POSSIBLE FOR THE MOUND. 3;r ``��;/ / Q. REMOVE EXCESS VEGETATION. PLOW DISK OR USING BACKHOE RAKER TEETH, ROUGFIEN THE SURFACE SOIL 6 INCHES DEEP. DO THIS ONLY IF THE MOISTURE /" , CONTENT IS LESS THAN THE PLASTIC UMIT tSOIL IS PLASTIC IF IT CAN BE ROLLED . =, INTO AN Ye INCH WIRE).DO NOT REMOVE ANY OF THE SURFACE SOIL. MOUNDCARE TO PREVENT _ • /, J pl.,w. / / / / �� PERFORMANCEPUDDLING OF LAY THE CLAY DURING CONSTRUCTIDEPENDS ON ON.DO NOT USE HEAVY CONSTRUC- / !� ION EQUIPMENT AND DO NOT CONSTRUCT THE MOUND WHEN THE CLAY SOIL IS -,:.-- :• ....s. •' / S.te/ 1 W A PLASTIC CONDITION. �'" �_� _.7/!-•' � L i / •/ 3. USE ONLY TRAGIC-TYPE EQUIPMENT FOR CONSTRUCTING THE MOUND SO AS NOT / r 9i. /- M �• TO COMPACT THE ORIGINAL. SOIL. �.� � 4. THERE MUST BE AT LEAST 2 FEET OF NATURAL OR FILL SOIL HAVING A PERCOLA- TION RATE NO SLOWER THAN 120 MINUTES PER INCH AND NO FASTER THAN 5 _ � yam_ '.`•. 1 �, /;`. MINUTES PER INCH,BEFORE PLACING THE LAYER OF CLEAN SAND / S .62 _ `� t• /.;. �' S THE 12 INCH LAYER OF CLEAN SAND IS PART OF THE MOUND CONSTRUCTION. SAND `C��o _ ---z-:.:,,,-..-.. . IS CONSIDERED CLEAN IF IT CAN PASS THE"FRUIT JAR TEST FOR CONCRETE SMD. `OPE �' ,. .. •, ,`.,. •v'•::. 6. THE TOP OF THE CLEAN SAND LAYER AND THE TOP OF THE ROCK BED MUST BE S/� /� ` `` '''•' " CONSTRUCTED LEVEL. �1 D N y 36, 1 `'�:iy;',• `-'.1,:.. 7 DISTRIBUTION PIPES ARE 1/2-INCH DIAMETER SPACED 40 INCHES ON CENTER N L cO \ CONNEIIEL TO A MANIFOLD IN THE CENTER OF THE ROCK BED. PIPES HAVE FI S D ` �^ !+ -INCH PERFORATIONS DRILLED EVERY 36 INCHES AND POINTING DOWNWARD. 1, T✓ •,, • USE A NEW DRILL BIT TO AVOID BURRS INSIDE THE PIPE. BROKE�A Ef, ; ^C -•.8. NINE INCHES OF ROCK ARE PLACED UNDER THE PERFORATED LATERALS AND 2 • INCHES ABOVE FOR A TOTAL ROCK DEPTH OF 12 INCHES. Up -~ 9. THE ROCK IS FIRST COVERED WITH A LAYER OF HAY OR STRAW WHICH 5 THEN B RN 1 ^�� •'� ~"-:•4-•: COVERED WITH A LAYER OF RED ROSIN PAPER LAPPED 6 INCHES AT THE SEAMS. A '�l/�F I0. AT LEAST fi INCHES OF LOAMY SAND SHOULD BE PLACED OVER THE TOP OF THE RR1 "EC I I. AD6-INCK BCHDLAYER OF TOP SOIL SHOULD BE PLACED OVER THE ENTIRE MOUND SO LA'rc THAT A CRASS COVER CAN BE ESTABUSHED. �1 �12. CROwN THE ABOVE THE ROCK1LAYER SO THAR AT TTHEAVY RA tJ WILL RUN 0 CENTER OF THE MOUND • • • 13. SIDE SLOPES OF THE DIKES SHOULD BE NO STEEPER THAN 4,1 ON CLAY SOILS AND 3,1 ON SANDY SOILS. t4. D -LAYER.DEPENDS ON THE AMOUNT-OF DAILY SE f). 15. MAXIMUM EFFLUENT DOSE PER PUMP CYCLE SHOULD BE NO MORE THE TABLE VALUES. 16. MINIMUM PUMPING RATE IS SHOWN IN TABLE PUMPING HEAD MUST BE ADEQUATE TO OVERCOME ELEVATION DIFFERENCE, FRICTION LOSS PLUS 5 FEET E-4 4 INCHES STRAW ' OR MARSH SANDY LOAM SOIL HAY AND LAYER OF RED ROSIN PAPER PERFORATED LATERAL GRASS COVER 6 INCHES SAND FILLTOPSOIL MAXIMUM SLOPE •--► 4 TO I 4. `-:.. . �. TOPSOIL` IJ % SLOPE �SUBSOIL PLOWED OR ,�,�.� CLEAN ROCK DISKED SURFACE 3/4 TO 21/p INCHES CROSS SECTION A - A PIPE FROM • PUMPING CHAMBER - w I • . - Y % • . o ___ L _ _ a • • PERFORATED I - LATERALS •i BED AREA—' ; z I---- -1 J o _. W W CO -LIJ O • - - z z . • .• 20 o 'oy 20 ' -- INCHE ct v ' [INCHES • L. - i - I 1 DIKE ,...1...._10 FEET —DIKE • MAX. _ J~ . TOTAL WIDTH • ' 1 • ` `. // ( • 1 i . 1 PLAN VIEW LAYOUT OF PERFORATED PIPE LATERALS FOR . PRESSURE DISTRIBUTION IN MOUND • PERFORATED PLASTIC PIPEIl'1'Zoir. ) cs-- S , END ONR COENTER.NPERORATIONF0 OR 36 FERFORAi ACING ON VIEW SSIZE AY BE 3/�OR /3?, •,,e,I Sp ‘4.4. *%%:...,6-' /z felp MAN I FOLD PIPE ?_"Dita, PERFORATIONS ON BOTTOM OFOct* , PLASTIC PIPE 10', • PIPE FROM S41ra PUMPING CHAMBER END CAP 40*, 1 Lel TEE TO TEE LATERAL-MANIFOLD CONSTRUCTION Grass Cover , Topsoil ;K\T/Is:\ ,e. • Loamy Sand Backfill . Hay or Straw Covered . . • . ' • z by Layer of Red Rosin — Paper (or nylon fabric) C �•r•C cL•L,cc,G�• tJ ' —Perforation Lateral . in Cap Near c`' ` '' Crown of Pipe cc ,.. , c. Tee Reducer Perforations at Lateral go) Manifold Invert ,.cc-,:. „< << Tees ,..,.. . .c.,--€- 7:777-77:77:77 ••• •:- :-: . • ': `--Roca,Layer 12 - Inch Layer of Clean Sand , PIGGY BACK PLUG IN WEATHER ALARM WIRE DROP BOX PROOF ENCLOSURE-OR LOCATE FROSTPROOFI NG THE ,, Y 4 IN HOUSE BASEMENT MANHOLE COVER SECURED p 12• SOIL COVER POWER SUPPLY------"0 `TO PREVENT UNAUTHORIZED DISCHARGE PIPE __'',• j �,,, CONTROL WIRE ) ,ENTRY (, PLACE A ROCK ENVELOPE , '�a 2'�z"DIA ROCK VY PUMP POWER CORD @- y + tI DRAIN TILE OR RIGID 24•MANHOLE AROUND DISCHARGE3PIPE. I FROM PUMP PERFORATED PLASTIC PIPE ROCK SHOULD BE /4 TO 2 /z 3' MIN. FROM BOTTOM OF TRENCH TO ��`�'"` • INCHES IN DIAMETER, WITH FROM . I + WATER TABLE OR CLAY OR ROCK UNION OR OTHER NO SAND. COVER WITH A 2 V. LAYER SEP IC ALARM FLOAT ON SEPARATE FAIT ING DISCONNECTUICK TANK INCH THICK SHEET OF ELECTRICAL CIRCUIT EXPANDED POLYSTYRENE. RESERVE CAPACITY WHEREVER POSSIBLE MAIN- AFTER ALARM SOUNDS TO 5O1L TREATMENT TAIN A GRASS COVER OVER SOIL TREATMENT AREAS FOR TYPE I HOMES AREA TOP OF TRENCH AND ALLOW _-_ START LEVEL 9— 1/4 WEEPHOLE FOR SNOW TO REMAIN IN PLACE. REQUIRED SOIL TREATMENT AREA 3•] ‘ DRAINBACK;OR WHEN SNOW COVER IS LIGHT, IN SQUARE FEET PER BEDROOM _ CHECK VALVE MAY SHUT-OFF LEVEL • - BE INSTALLED IF PLACE A 6 INCH HAY OR PERCOLATION S—— PIPE TO TREATMENT TRENCHES r AREA IS FROST STRAW LAYER ON GROUND • RATE IN 12•-18•MINIMUM DEPTH_ PROOF ABOVE PIPE. INCH MINUTES PER SEEPAGE DEPTH OF ROCK BELOW �OOQ� BEDS DISTRIBUTION PIPE, IN INCHES LPUMPABLE CAPACITY WW , AT LEAST 75 GALLONSa��V� ;�<, 6 12 18 24 • BACKFILL `�� EXPANDED M'te FASTER b _ , . — — — PUMPING RATE SHOULD NOT EXCEED DROP BOX POLYSTYRENE ��ila THAN 0.1 OUTFLOW CAPACITY OR 45 GALLONS PER MINUTE DISCHARGE 0.1 TO 5 125 125 100 85 75 (2700 GALLONS PER HOUR). PIPE PUMP DISCHARGE HEAD MUST BE ADEQUATE TO ROCK 3/4"-2'/2" DIA. 6 TO 15 190 190 150 125 115 OVERCOME ELEVATION DIFFERENCE BETWEEN THE 16 TO 30 250 250 200 165 150 PUMP AND DISTRIBUTION BOX PLUS FRICTION LOSS IN DISCHARGE PIPE. 31 TO 45 300 300 240 200 I80 46 TO 60 330 330 265 220 200 LIQUID CAPACITIES OF VERTICAL CIRCULAR TANKS SLOWER _ THAN 60b 1 INSIDE DIAMETER OF TANK GALLONS PER FOOT IN FEET OF DEPTH °SEWAGE FLOW • 150 GPD PER BEDROOM TO DETERMINE THE LIQUID bSPECIAL DESIGN SHOULD BE USED TO PROVIDE ADEQUATE 1.5 13.0 TREATMENT AND ABSORPTION OF EFFLUENT 2.0 23.5 CAPACITY OF ANY TANK, FIRST • DETERMINE THE SURFACE AREA , 2.5 37.0 OF THE LIQUID. MULTIPLY ' t 3.0 53.0 THIS VALUE BY 7.5 (GALLONS 4.0 94.0 PER CUBIC FOOT) TO DETER- RECOMMENDED AMOUNT OF EFFLUENT TO PUMP MINE THE TANK LIQUID PER CYCLE IS 25 PERCENT OF DAILY SEWAGE FLOW. 5.0 147.0 MINIMUM AMOUNT OF EFFLUENT TO PUMP PER 6.0 213.0 CAPACITY IN GALLONS PER CYCLE IS 75 GALLONS. FOOT OF DEPTH. FOR EXAMPLE, A CIRCULAR TANK WITH AN INSIDE DIAMETER OF 4 FEET HAS 94 GALLONS OF LIQUID CAPACITY PER FOOT OF DEPTH. TO PUMP 200 GALLONS PER CYCLE, THE PUMP CONTROL SWITCHES WOULD NEED TO BE SET 2.1 UNIVERSITY OF MINNESOTA (200/94) FEET APART. EXTENSION AGRICULTURAL ENGINEERING DSO, by REM �r I of I PUMPING STATION g'07 t24Nre R.. , /29'19 METAL 400040 iiirP ' . ,•01 -111111, COVER .14-, -.41-, . ".'1.1... - .. . . .. --.* ,.#-, . _ z � imp \r..• s 4::: . . . 1. 1 -----4 1 1 . .. I -4---7:-. 4 ?; , _.: ,_ • • • . _ . . • 1 v.; 1 1 Ai 1 V !1 ' . ,.> , . CONCRETE st. % pit; MANHOLE = s s = ..... . _ '� RING . - METHODS OF SECURING MANHOLE COVER TO PREVENT • UNAUTHORIZED ENTRY I ' 1 it PENCIL ___ i d MARKS f ® . . . ,..,14Willi . • 6' 4 :.. 20" �i \'i MANHOLE �Y/ .k I - I___ . INLET '::::::::-.._E.::::_PA..C_ :.= �"� ,_-tom �; OUTLET TEL •�• ?'_= it �% ; . .: E -- - -I ;; R.: CLEAN OUT TANK WHEN= • - - _ _ - __-t_ �q" IS 3" OR LESS OR -__-___ -= --- ___ - B "B" IS 12" OR LESS r -, ..•.• . . . . - -_ . - . . � yi / SLUDGE `' BLACK COLOR R DISTINGUISHES SLUDGE y �: _: LAYER FROM LIQUID _ • V • -4• : ••. r, 'V v y . • w MEASURE SCUM AND SLUDGE ACCUMULATIONS ni TI-1F SFPTIC TANK .