CODE REVIEW - EXISTING BUILDING
A. OCCUPANCY: OCC. AREA
EXISTING A-3 4850 S.F. NET
PROPOSED E 43920 S.F.
(NON -SEPARATED) 1-4 (ROOMS 1 B & 3) 720 S.F.
FIRE EQUiP. 210 S.F.
4850 S.F. NET
PER 308.5.2: ROOMS 1 B & 3 ARE '1-4" SINCE THEY HAVE NO EXIT TO THE EXTERIOR,
ROOMS 1A & 2 ARE "E" SINCE THEY EACH HAVE AN EXIT TO THE EXTERIOR.
B. CONSTRUCTION TYPE: 5-B
BUILDING IS SPRINKLERED WITH YARDS 4 SIDES
ALLOWABLE AREA (BASIC PER TABLE 503):9000 S.F.
BUILDING COMPLIES WiTHOUT PERMITTED INCREASES.
C. OCCUPANTS 1003.2.2.1 (ACTUAL NUMBER FACILITY S BEING DESIGNED FO
TABLE 1003.2.2.2: EDUCATIONAL - CLASSROOM: 20 NET S.F./OCC,
MINNESOTA RULES FOR CHILD CARE MANDATES MIN. 35 S.F. CARE AREA PER CHILD.
PROPOSED AREAS FOR CHILD CARE: CHILDREN CARE GiVERS AREA
PRESCHOOL ROOM 17 20 CHILDREN 2 ADULTS (1:10) 722 S.F.
PRESCHOOL ROOM 18 20 CHILDREN 2 ADULTS (1:10) 722 S.F.
INSIDE PLAY AREA 16 (SPACE SHARED WITH ROOMS 1, 17,18) 633 S.F.
TODDLER ROOM(S)1 A&B 21 CHILDREN 3 ADULTS (1:7) 799 S.F.
INFANT ROOM 2 (12 CRIBS) 4 CHILDREN 1 ADULT (1:4) 280 S.F.
INFANT ROOM 3 8 CHILDREN 2 ADULTS i1:4) 329 S.F.
TOTALS: 73 CHILDREN 10 ADULTS 2729 S.F.
D. EXITING - TABLE 1004.2.1:
E 2 EXITS REQ. OVER 50 OCC.
(308.5.2 - SECOND EXIT TO EXTERIOR REQUIRED FOf AGES 2-1/2 AND UNDER).
1-4 2 EXITS REQUIRED OVER 10 OCC.
PRESCHOOL CLASSROOMS (22 OCC.) REQUIRE 1 EXIT
INFANT AND TODDLER ROOMS 1A & 2 REQUIRE 1 EXIT TO EXTERIOR;1 TO INTERIOR.
TODDLER ROOMS 1 B (t14 OCC.) REQUIRES 2 EXITS
INFANT ROOM (6 OCC.) REQUIRES 1 EXIT BUT IS PROVIDED WITH 2,
E. TOILET FACILITIES:
TABLE 2902.1 EDUCATIONAL 1 PER 50 MALE & FEMALE; LAVS & W.C.
MINNESOTA RULES FOR CHILD CARE MANDATES MIN, ONE LAV & W.C. PER 15 CHILDREN.
BUILDING CURRENTLY HAS 2 TOILETS / 1 LAV IN WOMEN'S TOILET ROOM.
1 TOILET 11 URINAL / 1 LAV IN MEN'S TOILET ROOM.
EXISTING TOILET ROOMS ARE NOT ACCESSIBLE AND CANNOT BE MADE SO WITHOUT LOSING
A W.C. IN THE WOMEN'S AND THE URINAL IN THE MEN'S TOILET ROOMS. DOORS ARE 2' -6" -
PROPOSED: ADD A UNISEX TOILET ROOM WITH ACCESSIBLE TOILET AND LAV.
ADD A SECOND LAV TO WOMEN'S TOILET ROOM.
1. ALL WORK TO BE DONE TO MEET ALL STATE AND LOCAL CODES AND ORDINANCES.
CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS. NOTIFY OWNER OF
ADDITIONAL REPAIRS REQUIRED.
2. THOROUGHLY CLEAN ALL SPACES INCLUDING PLAY YARD.
3. PROVIDE 10 LB ABC DRY FIRE EXTINGUISHER (4A 60BC) IN SEMI -RECESSED CABINET
WHERE NOTED.
4, REPAIR LOOSE OR DAMAGED SECTIONS OF EXISTING RADIATION COVER.
5. WHERE NOTED, REMOVE EXISTING CEILING TILES; INSTALL 2x4 LAY IN SUSPENDED
CEILING TO MATCH EXISTING CEILING HEIGHT.
6. WHERE NOTED INSTALL NEW 2x2 CEILING TILES TO MATCH EXISTING IN EXISTING GRiD.
7, IN EXISTING SANCTUARY INSTALL NEW 2x2 CEILING TILES TO MATCH EXISTING TILES IN
STANDARD GRID TO MATCH EXISTING CEILING HEIGHT IN LARGE CENTRAL RAISED AREA.
8. REMOVE 3 EXISTING AIR CONDITIONERS LOCATED IN DOOR TRANSOMS. REMOVE INFILL
PANELS AND REPLACE WITH 1' INSULATED GLASS.
9. ALL NEW WALLS TO BE 5/8' GYPSUM BOARD EACH SIDE OF 2x4 STUDS AT 16' O.C. OR 3-5/8'
DRYWALL STUDS AT 24' 0. C. WITH 3.1/2' SOUND INSULATION. PROVIDE'J" BEAD AT ALL
LOCATIONS WHERE GYPSUM BOARD MEETS DIFFERING MATERIALS. VVALL CONSTRUC-
TiON TO PIERCE CEILING; CARRY SOUND BLANKET INSULATION AND GYPSUM BOARD ON
AT LEAST ONE SIDE OF WALL TO UNDERSIDE OF ROOF DECK. CUT TO FIT CLOSELY
AROUND BAR JOISTS. PROVIDE MOISTURE RESISTANT BOARD AT CERAMIC TILE, IN
TOILET ROOMS AND IN JANITORS CLOSET.
10. IN INFANT ROOM 3 REMOVE SOFFIT AND OLD CLOSET FRAMING AT WALLS. INSTALL
CEILING TILE AND GRID TO MATCH MAIN CEILING. INSTALL DRYWALL ENCLOSURE FOR
AIR HANDLER IF REQUIRED.
11. WHERE NOTED INSTALL NEW 3-0" S.C. WOOD DOORS IN STEEL FRAMES; MATCH
EXISTING DOOR HEIGHTS. MODIFY/CREATE OPENING IN CMU WALL AS REQUIRED.
ABOVE OPENING PROVIDE ENGINEERED LINTEL OR CUT OPENING FULL HEIGHT AND
INSTALL ENGINEERED BEAM AT ROOF FRAMING AND DRYWALL INFILL BELOW. VERIFY
LOCKING AND KEYING WITH OWNER.
12. VERIFY EXTENT OF CARPET REPLACEMENT & PAINTING OF EXIST. WALLS WITH OWNER.
13. IN INFANT ROOMS 2 & 3: REMOVE EXISTING CARPET; INSTALL CUSHIONED SHEET VINYL
FLOORING WITH VINYL BASE; PROVIDE BUILT IN DIAPER CHANGING UNIT (DCU) IN BOTH
ROOMS. INSTALL GYPSUM BOARD SIMILAR TO NOTE 20 ON ALL EXISTING CMU WALLS.
14. IN ROOM 2 REMOVE EXISTING CABINETS AND APPLIANCES; INSTALL ADA COMPLIANT
HAND SINK WITH WRiST BLADES ON FAUCET. INSTALL NEW 3'-0' x 7'-0' ALUM. DOOR AND
THERMALLY BROKEN FRAME, GLAZE WITH 1" INSULATING GLASS; CREATE OPENING IN
CMU WALL AS REQ. ABOVE OPENING PROVIDE ENGINEERED LINTEL. PATCH TO MATCH.
15. WHERE INDICATED IN INFANT ROOM 3, REMOVE CMU WALL CONSTRUCTION; PROVIDE
ENGINEERED STEEL BEAM ABOVE CEILING LINE.
16, IN TOILET ROOMS 4 AND 5 REMOVE EXISTING WATER CLOSETS AND LAVS. iN ROOM 4
INSTALL CHILDREN'S SIZE W.C., URINAL TO REMAIN; IN ROOM 5 INSTALL ONE STANDARD
RESIDENTIAL SIZE W.C. AND ONE CHILDREN'S SIZE W.C. INSTALL LAVS WITH RIM AT 21"
ABOVE FLOOR.
17. IN ROOMS 1A, 3 AND 5 ADD LAVS WHERE SHOWN. AT CMU FRAME -OUT WALL FOR
PLUMBING AS REQUIRED WITH 2X FRAMING AND GYPSUM BOARD FINISH; PAINT AND
INSTALL BASE TO MATCH EXISTING. LAYS IN ROOMS 1A& 3 TO BE ADA COMPLIANT HAND
SINKS WITH WRIST BLADES ON FAUCETS.
18, IN HALLWAY 6 REMOVE EXISTING DRINKING FOUNTAIN. DRINKING WATER WiLL BE
PROVIDED BY BOTTLED WATER DISPENSER.
19. IN JANITOR'S CLOSET 8 REMOVE FLOOR SINK AND LAUNDRY SINK. INSTALL NEW FLOOR
SINK CLOSE OPENING TO BOILER ROOM WITH DRYWALL CONST.
20. IN LOBBY 10 INSTALL GYPSUM BOARD ON CEILING AND WALLS; INSTALL ON WOOD OR
METAL FURRING. GYPSUM BOARD MAY BE ADHESIVELY APPLIED TO MASONRY WALLS IF
ADHESION CAN BE ASSURED.
21. REMOVE EXISTING MAIN ENTRANCE DOORS AND FRAME; INSTALL NEW ALUMINUM
ENTRANCE DOOR AND THERMALLY BROKEN FRAMES WITH SIDELIGHTS AND TRANSOM
TO FILL MASONRY OPENING. GLAZE WITH V INSULATING GLASS -TEMPERED IN DOOR
AND SIDELIGHTS. PROVIDE SIMILAR NON=THERMAL ASSEMBLY AT INNER VESTIBULE
OPENING WiTH 1/4' GLASS -TEMPERED IN DOOR AND SIDELIGHTS. PROVIDE EXIT
DEVICES ON THESE AND ALL BUILDING EXITS.
22. AT OUTER FACE OF ENTRANCE ALCOVE REMOVE TWO STEEL SCREEN SUPPORTS.
PATCH SURFACES TO MATCH EXISTING.
23, AT EXISTING GLAZED SANCTUARY WALL, REMOVE GLASS FROM AREAS EITHER SIDE OF
ENTRANCE DOORS; INSTALL 5/8" GYPSUM BOARD WITH PERIMETER'J' BEAD ON EACH
FACE OF EXISTING WOOD FRAMES. REPLACE GLASS IN DOORS WITH 1/4" TEMPERED
GLASS. GLASS IN TRANSOM PANELS IS TO REMAIN.
N. 5' BASE, FLOOR DRAIN, NSF
24 IN THREEHEN WELL4PROVIDE QUARRY TILE FLOOR EI
SINK AND REFRIGERATOR, STAINLESS STEEL SERVICE COUNTER ON
APPROVED FEET.
25. IN UNISEX TOILET ROOM 15 PROVIDE FLOOR DRAIN AND ADA TOILET & HAND SINK.
INSTALL 2x2 CERAMIC MOSAIC FLOOR TILE & 4-1/4' GLAZED WALL TILE TO HEIGHT OF 48'
AT ALL WALLS. PROVIDE GRAB BARS AS DETAILED & 24'x36' MIRROR WITH S.S. FRAME.
26. iN ROOMS 17 AND 18 REMOVE EXISTING RAISED PLATFORM. INSTALL CARPET AS
SELECTED BY OWNER. IN ROOM 18 INSTALL NEW ENTRANCE DOOR AND THERMALLY
BROKEN IMASONRY
INSULATING GLASS -TEMPERED INDOOR. PROVIDE EXIT DEVICE ON THIS EXT AND EXIT
FROM ROOM 17. IN ROOM 18 INSTALL HAND SINK IN 48' PREFINISHED VANITY BASE
CABINET. PROVIDE PUMP -OVER WASTE SYSTEM AND CONNECT TO WASTE SYSTEM AT
NEAREST AVAILABLE LOCATION.
27. AT NEW EXIT FROM ROOM 2 PROVIDE 56'x 56"x 6" CONCRETE STOOP ON 6" GRANULAR
BASE; DOWEL TO FOUNDATION; SLOPE AWAY AT 114' PER FOOT. UNDERLAY WITH 8'x 6'x 2"
EXTRUDED POLYSTYRENE INSULATON INTALLED HORIZONTALLY
Cutting Edge
Construction, Inc.
P.O. Bax 726
Long Lake, MN 55356
MECHANICAL & ELECTRICAL NOTES
28, MECHANICAL AND ELECTRICAL WORK IS DESIGN BUILD. CONTRACTOR TO COMPLY WITH
ALL APPLICABLE CODES AND TAKE FULL RESPONSIBILITY FOR SYSTEM DESIGN,
29. ALL MECHANICAL AND ELECTRICAL TRADES ARE RESPONSIBLE TO OBTAIN ALL REQUIRED
PERMITS.
30 OUT FLOOR FLOOR D
TO NEW SINKS W ROOMS 5, REQUIRED 14 AS 0EXTEND
O KITCHEN14 AND UNISEX TOILET ROOM 15;
EXTEND TO NEW VENTED RISER FOR FUTURE SINK IN WALL OF TODDLER ROOM 17 SEE
ALSO NOTES 24,25A 27.
31. IN BOILER ROOM 7 REMOVE NONFUNCTIONAL VENTILATION COMPONENTS. REPLACE
WATER HEATER. EVALUATE BOILER AND PERFORM RECOMMENDED SERVICE AT
DIRECTION OF OWNER.
32. IN ROOMS 14 & 15 REMOVE APPROXIMATELY 17 FOOT OF EXISTING RADIATION AND
RELOCATE IT TO WEST WALL OF INFANT ROOM 2, STARTING FROM THE NORTH; WEST
CORNER; ROUTE PIPING UNDER SLAB AT NEW DOOR OPENING 1N ROOM 2. INSTALL NEW
LOW PROFILE CAST IRON RADIATION IN ROOMS 14 & 15 AS REQ. FOR COMFORT
33, MODIFY SPRINKLER SYSTEM AS REQUIRED BY NEW CONSTRUCTION TO ACHIEVE
REQUIRED COVERAGE.
34. LIGHTING SHOWN IS CONCEPTUAL ONLY. PROVIDE FIXTURES AND LAYOUT TO ACHIEVE
A MIN. OF 50 FOOT-CANDLES !N CLASSROOWI & PLAY AREAS (ROOMS 1, 2, 3, 16, 17, &18).
35. PROVIDE ALL NECESSARY SWITCHING FOR NEW LIGHTING PROVIDING THREE WAY
SWITCHING IN ROOMS 1, 2, & 3. PROVIDE RECEPTACLES IN NEW WALLS ATA MAXIMUM OF
12' APART. PROVIDE CONNECTION FOR ALL NEW EQUIPMENT. VERIFY POWER REQUIRE-
MENTS WITH SUPPLIER OF EACH TYPE OF EQUIPMENT. PROVIDE CONNECTION FOR
WALL MOUNTED MICROWAVE IN KITCHEN AND RECEPTACLES AT 42' AT COUNTER.
36, PROVIDE WORKING FIRE ALARM SYSTEM WHETHER EXISTING OR NEW, SMOKE
DETECTION TO CODE. SERVICE EXISTING ILLUMINATED EXIT SIGNS AND EMERGENCY
LIGHTING AS REQUIRED FOR PROPER FUNCTIONING.
37. VERIFY WORKING CONDITION OF ALL EXISTING EXHAUST SYSTEMS. REPLACE AS
REQUIRED. PROVIDE EXHAUST FAN FROM NEW TOILET ROOM 15.
38, PROVIDE VENTILATION TO MEET REQUIREMENTS OF MINNESOTA STATE MECHANICAL
CODE BUT AT LEAST 7 CFM PER PERSON IN ALL CHILD CARE SPACES AND OFFICE.
SUGGESTED. PROVIDE AIR CONDITIONING IN CONJUNCTION WITH VENTILATION SYSTEM.
SUGGESTED SYSTEM:
A. iN RAISED AREA OF EXISTING SANCTUARY ABOVE NEW LAY -IN CEILING PROVIDE
ONE OR TWO HORIZONTAL AIR HANDLERS WITH MAKE-UP AIR SUPPLIED FROM
ROOF TO SERVE PLAY AREA 116 AND CLASSROOMS 17 & 18 AND ADJACENT AREAS.
B. IN NW CORNER OF INFANT ROOM 3 PROVIDE VERTICAL AIR HANDLER WITH
MAKE-UP AIR SUPPLIED THROUGH EXTERIOR WALL TO SERVE CLASSROOM 1,
INFANT ROOMS 2 & 3, AND OFFICE 9. DISTRIBUTE USiNG SPIRAL DUCT OF
REQUIRED SIZE. PROVIDE INSULATED RETURN ACROSS CEILING OF INFANT
ROOM 2 TO SERVE CLASSROOM 1 TO ASSURE SOUND SEPARATION BETWEEN
ROOMS 1 & 2.
ALTERNATIVE VENTILATION SOLUTIONS ARE INVITED WILL BE GIVEN CONSIDERATION
ON A COST AND EFFECTIVENESS BASIS.
44 %*0 44 '
JAL Architects Ltd.
307 Manitoba Avenue South
Wayzata • MN 55391
952-404-1665
I hereby certify that this plan, specification, or report
was prepared by me or under my direct supervision
and th I am a du y registered Architect under the
laws f stateof innesota. Date:3-)�-oC'
It �(
J. Andre�gress4AIA Reg. No: 14818
�{--
6 -0 - 6rer-41ZtaL r SVi SIGN