Loading...
HomeMy WebLinkAbout2007 Building Permit Plan Review - revised6 -12- 1 24' V GLEAR 3• v c a FLUSH ON PAPER OPEN SIDE HOLDER ' OF TANK M0UNT'6 , _ 36' AREA t18' :18- )AGGE551BLE TOILET ACCESSORY �- INSTALLATION DIAGRAM_._ Na s��t_s I '�� .- f fQ pa;¢�"L.=Nay.: _.= + 1 o •� Itl - I i ' -. • _fit/.- -- � - . goys -y�I Mla��1? {�G/;'i►did d I,ta'j� Zoe -1o1'E Ia 0 L -i t45 ■��� lit w . ' O.'..... ... .. , X . r1* IV T L-.V&T . 111 �' ----- Xt I • .. 1. ` • - TM L'-� -•. - F,;r j ~ ~ .••�- _- +2 :uta �fiL;� To►L�T..- , _ . �-1,-_--_-_--�'► •..-° � _ J�. � � 21 � � � 2 - -- Nty-I'1,1r - 01Z. O t_ .-. T I ,• I - .:l4 2o7.✓i x ? '42 1 -- .. �' - . 25 j V,G,T. d,�rT �P�"• t 1 t Cutting !Edge Construction, Inc. P.O. Box 726 Long Lake, MN 55356 CODE REVIEW - EXISTING BUILDING PLAN NOTES 1. ALL WORK TO BE DONE TO MEET ALL STATE AND LOCAL CODES AND ORDINANCES. A. OCCUPANCY: OCC. AREA CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS. _ NOTIFY OWNER OF ADDITIONAL REPAIRS REQUIRED. EXISTING A-3 4850 S.F. NET ` 1 2. THOROUGHLY CLEAN ALL SPACES INCLUDING PLAY YARD. PROPOSED E 43920 S.F. 3. PROVIDE 10 LB ABC DRY FIRE EXTINGUISHER (4A 60BC) IN SURFACE MOUNTED 'CABINET (NON -SEPARATED) 1-4 (ROOMS 1 B & 3) 720 S.F. FIRE EQUIP. 210 S.F. - WHERE NOTED IN LOBBY. 4850 S.F. NET 4. REPAIR LOOSE OR DAMAGED SECTIONS OF EXISTING RADIATION COVER. 5. WHERE NOTED, REMOVE EXISTING CEILING TILES; INSTALL 2x4 LAY IN SUSPENDED PER 308.5.2: ROOMS 1 B, 2 & 3 ARE "1 4" SINCE THEY HAVE NO EXIT TO THE EXTERIOR. CEILING TO MATCH EXISTING CEILING HEIGHT. ROOM 1A IS "E" SINCE IT HAS AN EXIT TO THE EXTERIOR. - i 6. WHERE NOTED INSTALL NEW 2x2 CEILING TILES TO MATCH EXISTING IN EXISTING GRID. B. CONSTRUCTION TYPE: 5-13 7. IN EXISTING SANCTUARY INSTALL NEW 2x2 CEILING TILES TO MATCH EXISTING 'TILES IN BUILDING IS SPRINKLERED WITH YARDS 4 SIDES STANDARD GRID TO MATCH EXISTING CEILING HEIGHT IN LARGE CENTRAL RAISED AREA.ALLOWABLE AREA (BASIC PER TABLE 503):9000 S.F. - I 8. REMOVE EXISTING MAIN ENTRANCE DOORS AND FRAME; INSTALL NEW ALUMINUM BUILDING COMPLIES WITHOUT PERMITTED INCREASES. j { ENTRANCE DOOR AND THERMALLY BROKEN FRAMES WITH SIDELIGHTS AND TRANSOM TO FILL MASONRY OPENING. PROVIDE EXIT DEVICE. C. OCCUPANTS - 1003 2 21 (ACTUAL NUMBER FACILITY IS BEING DESIGNED FORT: 9. REMOVE 3 EXISTING EXTERIOR ENTRANCE FRAMES, SIDELIGHTSAND AIR CONDITIONERS TABLE 1003.2.2.2: EDUCATIONAL - CLASSROOM: 20 NET S.F./OCC. LOCATED IN TRANSOMS. INSTALL NEW ALUMINUM ENTRANCE DOORS AND THERMALLY BROKEN FRAMES WITH SIDELIGHTS AND TRANSOMS TO FILL MASONRY OPENINGS. MINNESOTA RULES FOR CHILD CARE MANDATES MIN. 35 S.F. CARE AREA PER CHILD. SOUTHWEST FRAME TO HAVE FULL GLASS WITH CROSS MULLION AT 3' A.F.F., IN PLACE OF EXIT DOOR. PROVIDE EXIT DEVICES AT ALL DOORS. PROPOSED AREAS FOR CHILD CARE CHILDREN CARE GIVERS AREA 10. ALL NEW WALLS TO BE 518' GYPSUM BOARD EACH SIDE OF 2x4 STUDS AT 16' O.C. OR 3.5/8" TODDLER ROOM(S) 1A&B 21 CHILDREN 3 ADULTS (1:7) 799 S.F. DRYWALL STUDS AT 24" O.C. WITH 3-1/2' SOUND INSULATION. PROVIDE -J" BFA•y1 AT ALL INFANT ROOM 2 (12 CRIBS) 4 CHILDREN 1 ADULT (1:4) 280 S.F. LOCATIONS WHERE GYPSUM BOARD MEETS DIFFERING MATERIALS. WALL CONSTRUC- INFANT ROOM 3 8 CHILDREN 2 ADULTS (1:4) 273 S.F. TION TO PIERCE CEILING; CARRY SOUND BLANKET INSULATION AND GYPSUM BOARD ON PRESCHOOL ROOM 17 20 CHILDREN 2 ADULTS (1:10) 722 S.F. AT LEAST ONE SIDE OF WALL TO UNDERSIDE OF ROOF DECK. CUT TO FIT :aLOSELY PRESCHOOL ROOM 18 20 CHILDREN 2 ADULTS (1:10) 722 S.F. AROUND BAR JOISTS. PROVIDE MOISTURE RESISTANT BOARD AT CERAMIC, TILE, IN COMMON AREA 13 (SPACE SHARED w/ ROOMS 1. 14.151 629 S.F. AND IN JANITORS CLOSET. TOILET ROOMS A TOTALS: 73 CHILDREN 10 ADULTS 3425 S.F. 11. WHERE NOTED INSTALL NEW 3'-0' S.C. WOOD DOORS IN STEEL FRAMES; MATCH EXISTING DOOR HEIGHTS. VERIFY LOCKING AND KEYING AT ALL DOORS WITH r7WNER. D. EXITING - TABLE 1004.2.1: 12. AT EXISTING GLAZED SANCTUARY WALL, REMOVE GLASS FROM DOORS, SIDELIc.4-ITS AND E 2 EXITS REQ. OVER 50 OCC. l -TRANSOMS; REPLACE WITH 1/4' TEMPERED GLASS OR LEXAN PANELS. (308.5.2 - SECOND EXIT TO EXTERIOR REQUIRED FOR AGES 2-1/2 AND UNDER). 13. VERIFY EXTENT OF CARPET REPLACEMENT & PAINTING OF FUST. WALLS WITH OWNER. 1-4 2 EXITS REQUIRED OVER 10 OCC.. TODDLER ROOM 1A REQUIRES 1 EXIT TO EXTERIOR; 1 TO INTERIOR. 14. AT OUTER FACE OF ENTRANCE ALCOVE REMOVE TWO STEEL SCREEN SUPPORTS. TODDLER ROOM 1 B (t16 OCC.) AND INFANT ROOMS (t15 OCC.) REQUIRE 2 EXITS PATCH SURFACES TO MATCH EXISTING. PRESCHOOL CLASSROOMS 15 & 16 (22 OCC.) REQUIRE 1 EXIT 15. IN ROOM 1A: INSTALL HAND SINK PER NOTE 26 PROVIDE BUILT IN DIAPER CHANGING UNIT. E. TOILET FACILITI7S: _ 16. IN ROOM 2: REMOVE: EXISTING CABINETS, SINK AND APPLIANCES. PR0VIDE .KILT IN TABLE 290,2.1 EDUCnTiONAL i PER 50 MALE :. FEMALE; LAYS & W.C. DIAPER CHANGING UNIT (CCU) IN BOTH ROOMS. INSTALL GYP. BD. SIMILAR TO NOTE 21 MINNESOTA RU ES FOR CHILD CARE MANDATES MIN. OW: LAV & W.C. PER 15 CHILDREN. ON ALL EXISTING CMU WALLS. CREATE OPENING TO ROOM 3 IN CMU 11MLL AS BUILDING CURRENTLY HAS 2 TOILETS / 1 LAV IN WOMEN'S TOILET ROOM. REQUIRED. ABOVE OPENING PROVIDE ENGINEERED LINTEL OR CUT OPENING FULL 1 TOILET / 1 URINAL 11 LAV IN MEN'S TOILET ROOM. HEIGHT AND INSTALL ENGINEERED BEAM AT ROOF FRAMING. EXISTING TOILET ROOMS ARE NOT ACCESSIBLE AND CANNOT BE MADE SO WITHOUT LOSING 17. IN ROOM 3: INSTALL HAND SINK PER N0TE.26 FRAME -OUT CMU WALL FOR PLUMBING AS A W.C. IN THE WOMEN'S AND THE URINAL IN THE MEN'S TOILET ROOMS. DOORS ARE 2'-6". REQUIRED WITH 2X FRAMING AND GYP. BD. FINISH. INSTALLGYP. BD. SIMILAR TC NOTE 21 ON ALL EXISTING CMU WALLS. PROVIDE BUILT IN DIAPER CHANGING UNIT. REMOVE PROPOSED: ADD A UNISEX TOILET ROOM WITH ACCESSIBLE TOILET AND LAV. EXISTING CARPET; INSTALL VCT FLOORING WITH VINYL BASE. ADD 4 ADDITIONAL LAVS IN CHILD CARE AREAS. 18. IN TOILET ROOMS 4 AND 5 REPLACE EXISTING WATER CLOSETS AND LAVS. IN ROOM 4 REPLACE EXISTING DRINKING FOUNTAIN WITH DUAL HEIGHT ELECTRIC WATER COOLER. INSTALL CHILDREN'S SIZE W.C., URINAL TO REMAIN; IN ROOM 5 INSTALL ONE STANDARD RESIDENTIAL SIZE W.C. AND ONE CHILDREN'S SIZE W.C. INSTALL LAVS WITH RIM AT 21" ABOVE FLOOR. 19. IN HALLWAY 6 REMOVE EXISTING DRINKING FOUNTAIN. PROVIDE DUAL LEVEL ELECTRIC WATER COOLER IN ROOM 13 WHERE INDICATED. 20. IN JANITOR'S CLOSET, ROOM 8 REMOVE FLOOR SINK AND LAUNDRY SINK. INSTALL NEW - FLOOR SINK. CLOSE OPENING TO BOILER ROOM WITH DRYWALL CONST. 21. IN LOBBY, ROOM 10 INSTALL GYPSUM BOARD ON CEILING AND WALLS; INSTALL CN WOOD OR METAL FURRING. GYPSUM BOARD MAY BE ADHESIVELY APPLIED TO MASONRY WALLS IF ADHESION CAN BE ASSURED. REMOVE EXISTING FLOOR COVERING; INSTALL VCT FLOORING WITH VINYL BASE. - 22. IN KITCHEN, ROOM 11 PROVIDE QUARRY TILE FLOOR AND MIN. 5- BASE AND FLOOR DRAIN NEW WALLS TO BE FINISHED WITH-GL.ASSBOARD PANELS AND MOLDINGS FROrd TOP OF BASETOCbLING. CMU WALL TO RECEIVE EPDXY PAINT. PROVIDE NSF THREE WELL SINK, HAND SINK, REFRIGERATOR, STAINLESS STEEL SERVICE COUNTER ON APPROVED FEET, AND STAINLESS STEEL OVER -SHELVING ASREQUIRED. 23. IN UNISEX TOILET ROOM 12 INSTALL2x2 CERAMIC MOSAIC FLOOR T11 E.AND FLOOR DRAIN AND 4-1/4' GLAZED WALL TILE: TO HEIGHT OF 48' AT ALL WALLS. PROVIDE ADA TOILET & - - HAND SINK; ROUGH IN FOR URINAL IN LOCATION SHOWN. PROVIDE GRAB BARS AS DETAILED & 24'x36' MIRROR WITH S.S. FRAME. 24. IN ROOM 13 REMOVE EXISTING FLOOR COVERING AND WALLS AS INDICATED. INSTALL CARPET & CARPET BASE AS SELECTED BY OWNER. DRINKING FOUNTAIN PER NOTE 19. 25. IN ROOM 14 AND 15 REMOVE EXISTING RAISED PLATFORM. REMOVE EXISTING CARPET - INSTALL CARPET & CARPET BASE AS SELECTED BY OWNER IN AREAS SHOWN. IN _ BALANCE OF AREA INSTALL VCT FLOORING WITH VINYL BASE. INSTALL HAND SINKS _ WHERE SHOWN. _ MECHANICAL & ELECTRICAL NOTES ✓ 26. MECHANICAL AND ELECTRICAL WORK IS DESIGN BUILD. CONTRACTOR TO COMPLY WITH ALL APPLICABLE CODES AND TAKE FULL RESPONSIBILITY FOR SYSTEM DESIGN. 27. ALL MECHANICAL AND ELECTRICAL TRADES ARE RESPONSIBLE TO OBTAIN ALL REQUIRED PERMITS. 28. CUT FLOOR IN ROOMS 2, 3, 9, 11, 12,14 & 15 AS REQUIRED TO EXTEND WASTE PIPING UNDER FLOOR TO NEW SINKS IN ROOMS 1,A,3,14 & 15; AND TO KITCHEN 11 ARID UNISEX TOILET ROOM 12; PROVIDE HOT AND COLD WATER AS REQUIRED. HAND SINKS TO BE 4 ADA COMPLIANT WITH WRIST BLADES ON FAUCET. SEE ALSO NOTES 22 & 23. -_ 29. IN BOILER ROOM 7 REMOVE NONFUNCTIONAL VENTILATION COMPONENTS. REPLACE WATER HEATER. EVALUATE BOILER- AND PERFORM RECOMMENDED SERVICE AT - ,k DIRECTION OF OWNER. 30. IN ROOMS 12 & 15 REMOVE EXISTING RADIATION. ROUTE PIPING OVER CEILING AS l REQUIRED TO MAINTAIN LOOP. 31. MODIFY SPRINKLER SYSTEM AS REQUIRED BY NEW CONSTRUCTION TO ACHIEVE �. REQUIRED COVERAGE. t 32. LIGHTING SHOWN IS CONCEPTUAL ONLY. PROVIDE FIXTURES AND LAYOUT TOACHIEVE JAL Architects Ltd., A MIN. OF 50 FOOT-CANDLES IN CLASSROOM & COMMON AREA (ROOMS 1, 2, 3,13, 14, & 15). 3O% Manitoba South PROVIDE THREE WAY .Avenue 33. PROVIDE ALL NECESSARY SWITCHING FOR NEW LIGHTING. IN ROOMS 1, 2, &3. PROVIDE RECEPTACLES IN NEW WALLS AT A MAXIMUM OF � ( S (✓rte (� - Wayzata - MN 55391 I SWITCHING VERIFY POWER REQUIRE- 1z APART. PROVIDE CONNECTION FOR ALL NEW EQUIPMENT. VER ''�' 952-4 04-1665 MENTS WITH SUPPLIER OF EACH TYPE OF EQUIPMENT. PROVIDE CONNECTION FOR CITY OF ORONO '7 WALL MOUNTED MICROWAVE IN KITCHEN AND RECEPTACLES AT 42' AT COUNTER. NEW AND SMOKE DETECTION TO BUIL f3iiiC _ try 1T F'L.1J �,;,1i EEW hereby certify that this plan, Specification, or report t LA 34. PROVIDE WORKING FIRE ARM SYSTEM - EXISTING OR fNiF'ECTORI CODE. SERVICE EXISTING ILLUMINATED EXIT SIGNS AND EMERGENCY LIGHTING AS Was prepared by me or under my direct supervision REQUIRED FOR PROPER FUNCTION. DATA x"iso. AS 11 -I D and th I am a dup registered Architect under the 35. VERIFY WORKING CONDITION OF ALL EXISTING EXHAUST SYSTEMS. REPLACE AS u1, laws f estateofMinnesota. Date' 3-1%-05 REQUIRED. PROVIDE EXHAUST FAN FROM NEW TOILET ROOM 12 [' ' ' '1' 1, i G ' : t `:''` AS N. :mED / 36. PROVIDE VENTILATION TO MEET REQUIREMENTS OF MINNESOTA STATE MECHANICAL I CODE BUT AT LEAST 7 CFM PER PERSON IN ALL CHILD CARE SPACES AND OFFICE. o Y.,u r r / c SL a# ba dons ' J. Andre T ndres AIA Reg. No: 14818 SUGGESTED. PROVIDE AIR CONDITIONING IN CONJUNCTION WITH VENTILATION SYSTEM. 1, ; r „ f:Cti +n ;, k , t ci..I . r, z�,^^: ^g code. a t , c. «c; in this review KEEP THIS PLAN' 3� i' ON 8171 E AT ALL TIM98 5 21+ nl o -r a f_) c.� nr P chi 5 -10 -O 5 - 6 NSAAL IeSVI SIaN PROJECT