HomeMy WebLinkAbout2005 Building Permit Plan Review_ -4-t _
Ar
1 ; _ -4
PICO
i
s�
I
4
Its
I p SII i
I N1A`1'ar; GPTl0p-1 t4oi1b �jp _ p`11p21`� lfs�
Its rt-vNY _, .__..__._ f r G1
� I
1 J N
'I
r A�l
ci]
!
�s -
1
P
O r
I _
1
J( ryr
t
t
r'
1
r �r
I"rG
l4 OTC, Ii I
t
►I s
DIY � (fi r 2c�� ' I
I
R
I i '
1 1
1 3
r
ayl1 s! , V` Nt.,L_.
N P'Tri
18'
2' MIN.
CLEAR
3'
a► FLUSH ON PAPER
OPEN 51DE HOLDER
OF TANK MOUNT"G
36' AREA
MIN.
ACCESSIBLE TOILET ACCESSORY
INSTALLATION DIAGRAM_ N,o
CODE REVIEW - EXISTING BUILDING
A. OCCUPANCY: OCC. &E EA
EXISTING A-3 4850 S.F. NET
PROPOSED E 43920 S.F.
(NON -SEPARATED) 1-4 (ROOMS 1 B & 3) 720 S.F.
FIRE EQUIP. 210 S.F.
4859 S.F. NET
PER 308.5.2: ROOMS 1B & 3 ARE "1-4" SINCE THEY HAVE NO EXIT TO THE EXTERIOR.
ROOMS 1A & 2 ARE "E" SINCE THEY EACH HAVE AN EXIT TO THE EXTERIOR.
B. CONSTRUCTION TYPE: 5-B
BUILDING IS SPRINKLERED WITH YARDS 4 SIDES
ALLOWABLE AREA (BASIC PER TABLE 503): 9000 S.F.
BUILDING COMPLIES WITHOUT PERMITTED INCREASES.
C. OCCUPANTS - 1003.2.2.1 (ACTUAL NUMBER FACILITY IS BEING DESIGNED FOR):
TABLE 1003.2.2.2: EDUCATIONAL - CLASSROOM: 20 NET S.F./OCC.
MINNESOTA RULES FOR CHILD CARE MANDATES MIN. 35 S.F. CARE AREA PER CHILD.
PROPOSED AREAS FOR CHILD CARE: CHILDREN CARE GIVERS AREA
PRESCHOOL ROOM 17 20 CHILDREN 2 ADULTS (1:10) 722 S.F.
PRESCHOOL ROOM 18 20 CHILDREN 2 ADULTS (1:10) 722 S.F.
INSIDE PLAY AREA 16 (SPACE SHARED WITH ROOMS 1, 17,18) 633 S.F.
TODDLER ROOM(S) 1A&B 21 CHILDREN 3 ADULTS (1:7) 799 S.F.
INFANT ROOM 2 (12 CRIBS) 4 CHILDREN 1 ADULT 0:4) 280 S.F.
INFANT ROOM 3 8 CHILDREN 2 ADULTS -(•1.41 329 S.F.
TOTALS: 73 CHILDREN 10 ADULTS 2729 S.F.
D. EXITING - TABLE 1004.2.1:
E 2 EXITS REQ. OVER 50 OCC.
(308.5.2 - SECOND EXIT TO EXTERIOR REQUIRED FOk'AGE8 2-1/2 AND UNDER).
1-4 2 EXITS REQUIRED OVER 10 OCG.
PRESCHOOL CLASSROOMS (22 OCC.) REQUIRE 1 EXIT
INFANT AND TODDLER ROOMS 1 A & 2 REQUIRE 1 EXIT TO EXTERIOR; 1 1'O INTERIOR.
TODDLER ROOMS 1 B (±14 OCC.) REQUIRES 2 EXITS
INFANT ROOM (6 OCC.) REQUIRES 1 EXIT BUT IS PROVIDED WITH 2.
E. TOILET FACILITIES:
TABLE 2902.1 EDUCATIONAL 1 PER 50 MALE & FEMALE; LAVS & W.C.
MINNESOTA RULES FOR CHILD CARE MANDATES MIN. ONE LAV & W.C.. FIER 15 CHILDREN.
BUILDING CURRENTLY HAS 2 TOILETS / 1 LAV IN WOMEN'S TOILET ROOM.
1 TOILET / 1 URINAL / 1 LAV IN MEN'S TOILET ROOM.
EXISTING TOILET ROOMS ARE NOT ACCESSIBLE AND CANNOT BE MADE SO WITHOUT LOSING
A W.C. IN THE WOMEN'S AND THE URINAL IN THE MEN'S TOILET ROOM' 3. DOORS ARE 2'-6".
PROPOSED: ADD A UNISEX TOILET ROOM WITH ACCESSIBLE TOILET AND LAV.
ADD A SECOND LAV TO WOMEN'S TOILET ROOM.
Cutting Edge
Construction, Inc,
P.U. Box 726
Long Lake, THIN 55356
T ------ = -- PLAN NOTES MECHANICAL & ELECTRICAL NOTES
1 I - A1 1 1. ALL WORK TO BE DONE TO MEET ALL STATE AND LOCAL CODES AND ORDINANCES. 28. MECHANICAL AND ELECTRICAL WORK IS DESIGN BUILD. CONTRACTOR TO COMPLY WITH
CONDITIONS. NOTIFY OWNER OF S AND TAKE FULL RESPONSIBILITY FOR SYSTEM DESIGN.
CONTRACTOR TO FIELD VERIFY ALL EXISTING CO ALL APPLICABLE CODE
ADDITIONAL REPAIRS REQUIRED.
i Q f 29. ALL MECHANICAL AND ELECTRICAL TRADES ARE RESPONSIBLE TO OBTAIN ALL REQUIRED
i - Cw*� ,+' 2. THOROUGHLY CLEAN ALL SPACES INCLUDING PLAY YARD.
PERMITS.
3. PROVIDE 10 LB ABC DRY FIRE EXTINGUISHER (4A 60BC) IN SEMI -RECESSED CABINET 30. CUT FLOOR IN ROOMS 2, 3, 9 AND 14 AS REQUIRED TO EXTEND WASTE PIPING UNDER
WHERE NOTED. CA/3gu LT W t `A rIM� W A41-514Pt- 06� (Ae-4e, w?_- t90 • z3 -O FLOOR TO NEW SINKS IN ROOMS 1A,3, 5, TO KITCHEN 14 AND UNISEX TOILET ROOM 15;
EXTEND TO NEW VENTED RISER FOR FUTURE SINK IN WALL OF TODDLER ROOM 17. SEE
4. REPAIR LOOSE OR DAMAGED SECTIONS OF EXISTING RADIATION COVER.
0 o" e 41p? �i - ;. {{ ALSO NOTES 24, 25,& 27.
5. WHERE NOTED, REMOVE EXISTING CEILING TILES; INSTALL 2x4 LAY IN SUSPENDED
31. IN BOILER ROOM 7 REMOVE NONFUNCTIONAL VENTILATION COMPONENTS. REPLACE
CEILING TO MATCH EXISTING CEILING HEIGHT. WATER HEATER. EVALUATE BOILER AND PERFORM RECOMMENDED SERVICE AT
DIRECTION OF OWNER.
CEILING T O MATCH EXISTING IN E;4iSTING GRID.
DIRE
i, �' 6. WHERE NOTED INSTALL NEW 2x2 C LNG ILES T
ro 7. IN EXISTING SANCTUARY INSTALL NEW 2x2 CEILING TILES TO MATCH Eki" !NG TILES IN 32. IN ROOMS 14 & 15 REMOVE APPROXIMATELY 17 FOOT OF EXISTING RADIATION AND
i STANDARD GRID TO MATCH EXISTING CEILING HEIGHT IN LARGE CENTRAL, RA.§SED AREA. RELOCATE IT TO WEST WALL OF INFANT ROOM 2, STARTING FROM THE NORTH WEST
o I j CORNER; ROUTE PIPING UNDER SLAB AT NEW DOOR OPENING IN ROOM 2. INSTALL NEW
8. REMOVE 3 EXISTING AIR CONDITIONERS LOCATED IN DOOR TRANSOMS. R:;MOVE INFILL LOW PROFILE CAST IRON RADIATION IN ROOMS 14 & 15 AS REQ. FOR COMFORT.
-••� •- - �) i i� (' ) M PANELS AND REPLACE WITH 1" INSULATED GLASS.
-'- ; 33. MODIFY SPRINKLER SYSTEM AS REQUIRED BY NEW CONSTRUCTION TO ACHIEVE
° ? 9. ALL NEW WALLS TO BE 5/8' GYPSUM BOARD EACH SIDE OF 2x4 STUDS AT 16" C i OR 3-5/8" RED COVERAGE.
- i } REQUI
i t . DRYWALL STUDS AT 24" O.C. WE"i H 3 1/2` SOUND INSULATION. PROVIDE °.i " �+' ^ AT ALL
a. -_- `�"-`--t•'�•-.-. _ �o--.---. 34 I ic�F .Tlt:.. _!-�.�V, :�. IS C,Ui\iC,EP! UAL.. ONLY PROVIDE .._ T JR_ - .4:.D �A, OUT � O ACH,_ v is
r
1 4'
c,� - I 13.
J SIP. CLASSROOM &PLAY AREAS ROOMS 1 16 17 & .
r A MIN. JF �0 FOOT-CANDLES 2 3
1 INSULATION AND GYP...,w .OA.RD ON ( )
TION TO PIERCE CEILING; CARRY S UND BLANKET INS
--- --_- 1- -- L I AT LEAST ONE SIDE OF WALL TO UNDERSIDE OF ROOF P1DECK. CUT TO FIT CLOSELY 35. PROVIDE ALL NECESSARY SWITCHING FOR NEW LIGHTING PROVIDING THREE WAY
AROUND BAR JOISTS. PROVIDE MOISTURE RESISTANT BOARD AT CER/ MIC TILE, IN
• �' _. ..__ }.r SWITCHING IN ROOMS 1, 2, & 3. PROVIDE RECEPTACLES IN NEW WALLS ATA MAXIMUM OF
TOILET ROOMS AND IN JANITORS CLOSET.
9 I 12' APART. PROVIDE CONNECTION FOR ALL NEW EQUIPMENT. VERIFY POWER REQUIRE -
0,1 ?r - r 10. IN INFANT ROOM 3 REMOVE SOFFIT AND OLD CLOSET FRAMING AT WA.LS. INSTALL MENTS WITH SUPPLIER OF EACH TYPE OF EQUIPMENT. PROVIDE CONNECTION FOR
CEILING TILE AND GRID TO MATCH MAIN CEILING. INSTALL DRYWALL ENC 1_0,r, E FOR WALL MOUNTED MICROWAVE IN KITCHEN AND RECEPTACLES AT 42" AT COUNTER.
" AIR HANDLER IF REQUIRED.
I
f 36. PROVIDE WORKING FIRE ALARM SYSTEM WHETHER EXISTING OR NEW, SMOKE
11. WHERE NOTED INSTALL NEW 3-0" S.C. WOOD DOORS IN STEEL FWMES; MATCH DETECTION TO CODE. SERVICE EXISTING ILLUMINATED EXIT SIGNS AND EMERGENCY
I I EXISTING DOOR HEIGHTS. MODIFY/CREATE OPENING IN CMU WALL A� REQUIRED.
LIGHTING AS REQUIRED FOR PROPER FUNCTIONING.
LINTEL OR CUT OPENING FULL HEIGHT AND
I_. ABOVE OPENING PROVIDE ENGINEERED 37. VERIFY WORKING CONDITION OF ALL EXISTING EXHAUST SYSTEMS. REPLACE AS
INSTALL ENGINEERED BEAM AT ROOF FRAMING AND DRYWALL INFILL BELOW. VERIFY
LOCKING AND KEYING WITH OWNER. MQS
! I I REQUIRED. PROVIDE EXHAUST FAN FROM NEW TOILET ROOM 15.
T &-e OQR" AOVL- rvvon,,. w4 sl �
I W i'1+o yr K'° VR An' S <N°t,1(EtQG�Q 38. PROVIDE VENTILATION TO MEET REQUIREMENTS OF MINNESOTA STATE MECHANICAL
y y �, t
12. VERIFY EXTENT OF CARPET REPLACEMENT & PAINTING OF EXIST. WAELS'IVITN OWNER.
-- -' �- - CODE BUT AT LEAST 7 CFM PER PERSON IN ALL CHILD CARE SPACES AND OFFICE.
13. IN INFANT ROOMS 2 & 3: REMOVE EXISTING CARPET; INSTALL CUSHIONED SHEET VINYL SUGGESTED. PROVIDE AIR CONDITIONING IN CONJUNCTION WITH VENTILATION SYSTEM.
FLOORING WITH VINYL BASE; PROVIDE BUILT IN DIAPER CHANGING UNIT fi)CU) IN BOTH SUGGESTED SYSTEM:
TALL GYPSUM BOARD SIMILAR TO NOTE 20 ON ALL EXISTING CMU WALLS.
ROOMS INS A. IN RAISED AREA OF EXISTING SANCTUARY ABOVE NEW LAY -IN CEILING PROVIDE
- r t
14. IN ROOM 2 REMOVE EXISTING CABINETS AND APPLIANCES; INSTALL ADS COMPLIANT ONE OR TWO HORIZONTAL AIR HANDLERS WITH MAKE-UP AIR SUPPLIED FROM
- _
HAND SINK WITH WRIST BLADES ON FAUCET. INSTALL NEW 3'-0" x T-0" ALUM. DOOR AND ROOF TO SERVE PLAY AREA 116 AND CLASSROOMS 17 & 18 AND ADJACENT AREAS.
_ THERMALLY BROKEN FRAME; GLAZE WITH 1" INSULATING GLASS; CREAT_ OPENING IN
r CMU WALL AS REQ. ABOVE OPENING PROVIDE ENGINEERED LINTEL. PATCH TO MATCH. B. IN NW CORNER OF INFANT ROOM 3 PROVIDE VERTICAL AIR HANDLER WITH
{ MAKE-UP AIR SUPPLIED THROUGH EXTERIOR WALL TO SERVE CLASSROOM 1,
11 I I 15. WHERE INDICATED IN INFANT ROOM 3, REMOVE CMU WALL CONSTRUCT ON; PROVIDE
INFANT ROOMS 2 & 3, AND OFFICE 9 DISTRIBUTEUSING SPIRAL DUCT OF
ENGINEERED STEEL BEAM ABOVE CEILING LINE.
I REQUIRED SIZE PROVIDE INSULATED RETURN ACROSS CEILING OF INFANT
--; -�a - •- � -« - +- � ( a
ROOM 2 TO SERVE CLASSROOM 1 TO ASSURE SOUND SEPARATION BETWEEN
16. IN TOILET ROOMS 4 AND 5 REMOVE EXISTING WATER CLOSETS AND LAV:,. IN ROOM 4
k' ; INSTALL CHILDREN'S SIZE W.C., URINAL TO REMAIN; IN ROOM 5 INSTALL ONE STANDARD ROOMS 1 & 2.
r- RESIDENTIAL SIZE W.C. AND ONE CHILDREN'S SIZE W.C. INSTALL LAYS W!'TH RIM AT 21"
j ALTERNATIVE VENTILATION SOLUTIONS ARE INVITED WILL BE GIVEN CONSIDERATION
ABOVE FLOOR.
0_x tl �"', G I ON A COST AND EFFECTIVENESS BASIS.
' ( a 17. IN ROOMS 1A 3 AND 5 ADD LAVS WHERE SHOWN. AT CMU FRAME -OJT WALL FOR r �.�+ 0 /v%6LM. NS(� a �7-� � �,Cl�+c �Av�� 9S2'2Y4 • Y6 p 0
\ � ISwsS w I rr1 c
1 3 ; PLUMBING AS REQUIRED WITH 2X FRAMING AND GYPSUM BOARD FINIS1- PAINT AND
-
I INSTALL BASE TO MATCH EXISTING. LAYS IN ROOMS 1A& 3 TO BE ADA COMPLIANT HAND
SINKS WITH WRIST BLADES ON FAUCETS
18.
-'�1®C�IA/A;TErc VI�OJIJT '
R. - C'AbL- NA5 N O e x �T 1 �� M nt��►^
r
19. IN JANITOR'S CLOSET 8 REMOVE FLOOR SINK AND LAUNDRY SINK. INSTALL NEW FLOORy vl
i` SINK. CLOSE OPENING TO BOILER ROOM WITH DRYWALL CONST.�,F
. r•9
CI 20. IN LOBBY 10 INSTALL GYPSUM BOARD ON CEILING AND WALLS; INSTALL DN WOOD OR g T� QRQO -a
F
I k4 METAL FURRING. GYPSUM BOARD MAYBE ADHESIVELY APPLIED TO MASONRY WALLS IF UILCIINIG MR IT PLAAN REVIEW
ADHESION CAN BE ASSURED. IN9PzCTOR_,
_ _ r I ` r�"�"'��� I � � � _ �',. , __ 21. REMOVE EXISTING MAIN ENTRANCE DOORS AND FRAME; INSTALL NE'JV ALUMINUM QATE.- }C( `O __.._,-. �'�' h".41i' P•10,_Y„_,_,,..
ENTRANCE DOOR AND THERMALLY BROKENFRAMES WITH SIDELIGHTS /.ND TRANSOM ' �pf"r1 t I
TO FILL MASONRY OPENING. GLAZE WITH 1' INSULATING GLASS -TEMPERED IN DOOR
� .. ___...... _. .__.._ $r.___ ._•__. is t --_-�. -' � l p � .. �, ;. .,�, 1a:.•,
AND SIDELIGHTS. PROVIDE SIMILAR NON -THERMAL ASSEMBLY AT INNER VESTIBULE
0,K tl�,Y
OPENING WITH 1/4' GLASS -TEMPERED IN DOOR AND SIDELIGHTS. PROVIDE EXIT .
.W
v�LT
DEVICES ON THESE AND ALL BUILDING EXITS. a ,,r .• . u, � a14
NO dow
22 E REMOVE TWO STEEL SCR SUPPORTS. Ir i� r'
1 _ _ _ _ r_ EE': S r� .n8 zoning Code
` I PATCH SURFACES TO MATCH EXISTING. R 'E '_ .. r;;: li notOd in t;i;s reVie�,
` AT OUTER FACE OF ENTRANCE ALCOVE
_ - THIS PL44 Q 1 ON 81TE AT ALL TIMES
s ° t 23. AT EXISTING GLAZED SANCTUARY WALL, REMOVE GLASS FROM AREAS EITHER SIDE OF
ENTRANCE DOORS; INSTALL 5/8" GYPSUM BOARD WITH PERIMETER "J' BFAD ON EACH
s' ? FACE OF EXISTING WOOD FRAMES REPLACE GLA S IN DOORS WITH 1!4" TEMPERED
{ ' L _ _ 1_ ___ . __ I L GLASS. GLASS IN TRANSOM PANELS IS TO REMAINS
E50 Wa,G z.a- d3lud U) .
24. IN KITCHEN 14 PROVIDE QUARRY TILE FLOOR AND MIN. 5' BASE, FLOOR DRAIN, NSF
THREE WELL SINK AND REFRIGERATOR, STAINLESS STEEL SERVICE COUNTER ON
'\;/'y/
APPROVED FEET.
25. IN UNISEX TOILET ROOM 15 PROVIDE FLOOR DRAIN AND ADA TOILET & HAND SINK.
JAL Architects Ltd.
INSTALL 2x2 CERAMIC MOSAIC FLOOR TILE & 4-1/4' GLAZED WALL TILE TO HEIGHT OF 48'
AT ALL WALLS. PROVIDE GRAB BARS AS DETAILED & 24'x36' MIRROR WITH S.S. FRAME.
307 Manitoba Avenue South
26. IN ROOMS 17 AND 18 REMOVE EXISTING RAISED PLATFORM. INSTALL CARPET AS
DOOR AND THERMALLY
Wayzata • MN 55391
SELECTED BY OWNER. IN ROOM 18 INSTALL NEW ENTRANCE
952-404-1665
BROKEN FRAME WITH TRANSOM TO FILL MASONRY OPENING. GLAZE WITH V
INSULATING GLASS -TEMPERED IN DOOR PROVIDE EXIT DEVICE ON THIS EXIT AND EXIT
FROM ROOM 17• IN ROOM 18 INSTALL HAND SINK IN 48' PREFINISHED VANITY BASE
CABINET. PROVIDE PUMP -OVER WASTE SYSTEM AND CONNECT TO WASTE SYSTEM AT
I hereby certify that this plan, specification, or report
NEAREST AVAILABLE LOCATION.
Was prepared by me Or under my direct supervision
27. AT NEW EXIT FROM ROOM 2 PROVIDE 56'x 56"x 6" CONCRETE STOOP ON 6° GRANULAR
BASE; DOWEL TO FOUNDATION, SLOPE AWAY AT 1/4' PER FOOT. UNDERLAY WITH 8'x 6'x 2"
EXTRUDED POLYSTYRENE INSULATON INTALLED HORIZONTALLY
f
and tha I am a du y registered Architect under the
Taws �f estate of innesota. Date: 3 - I �-
8
E50 Wa,G z.a- d3lud U) .