HomeMy WebLinkAbout2010 - 00213 - sprinkler system CITY OF ORONO PERMIT NO.: 2010-00213
2750 KELLEY PARKWAY
ORONO,MN 55356- DATE ISSUED: 04/19/2010
(952)249-4600 FAX: (952) 249-4616
ADDRESS : 2350 WAYZATA BLVD W 2390 tutu*,,B 14- W •
PIN : 34-118-23-22-0014 }larve1t /veer
LEGAL DESC : EAST WILLOW WOODS
: LOT 001 BLOCK 001
PERMIT TYPE : FIRE SYSTEMS
PROPERTY TYPE : COMMERCIAL-BUSINESS
CONSTRUCTION TYPE : SPRINKLER SYSTEM-IN BUILDING
NOTE: INSPECTIONS ARE DONE BY FIRE MARSHALL,JAMES VAN EYLL.
PLEASE CALL JAMES VAN EYLL DIRECTLY AT:(952)473-9701 TO SET UP AN INSPECTION.
ENTER THE VALUTATION 7984
APPLICANT FIRE SPRINKLER-COMMERCIAL 99.80
MIDWEST FIRE PROTECTION INC. STATE SURCHARGE VAL OTHER 3.99
324 HARDING STREET NE
MINNEAPOLIS,MN 55413- MAIL-IN FEE 2.00
(612)331-1411 TOTAL 105.79
Minnesota State License#: CO21
OWNER
Otten Bros.
OTTEN,CLIFF&LOUISE
2350 WAYZATA BLVD W
LONG LAKE,MN 55356-
AGREEMENT AND SWORN STATEMENT
The work for which this permit is issued shall be performed according to
the approved plans and specifications,applicable City approvals,and the
State Building Code. This permit is for only the work described and does
not grant permission for additional or related work which requires separate
permits. All provisions of laws and ordinances governing this type of work
shall be compied with whether or not specified herein.This permit will
expire and become null and void if construction authorized is not
commenced within 180 days of the date of issuance,or if construction is
suspended for a period of 180 days at any time after work has commenced.
The applicant is responsible for assuring all required inspections are
requested in conformance with the State Building Code.This permit may be
revoked at any time for due cause. Onatk-/
/ G
/
Applicant Permitee Signature /Date / Is y Signature Date/
SEPARATE PERMITS REQUIRED FOR WORK OTHER THAN DESCRIBED ABOVE.
ATT'FOM .' L , s r ER.PER it i.46
❑ New ❑ Addition ❑✓ Remodel ❑ Replace
Site Address: 2380 Wayzata Blvd.
Owner: Harvest Moon Co-op Mailing Address: 2380 Wayzata Blvd.
City: Zip:
Home Phone: Alternate Phone:
Contractor/A Midwest Fire Protection, Inc. Contact Person: James A. Kuempel
pp..
Address: 324 Harding Street NE State License#: CO21
City: Minneapolis Zip: 55413 Expiration Date: 6/30/10
Phone: (612)331-1411 Alternate Phone:
`3.t • 4> 3...! ,, 4,,a f'Fi ? .N LE 'TIP, i�`�1��
0 Commercial—Fire Sprinkler 8 Residential—Fire Sprinkler
Fire Systems Permit Fire Systems Permit
* Base Price=Contract Price: $ 7,984.00 x.0125 =$ 9980 (Minimum$35.00)
*Surcharge=Contract Price:$ 7,984.00 x.0005 =$ 3.99 (Minimum $ .50)
* Mail-In Fee(Only On Mail In Applications) =$ 2.00
*Total Cost of Permit: =$ 105.79
The . sersig.ed herby applies to the City for issuance of a Sprinkler Systems Permit. Applicant agrees
-at all system, shall be designed, installed and maintained to N.F.P.A.-13,N.F.P.A.-25,Minnesota State
Building Code innesota State Fire Code and Standards,and certifies that all statements made on this
applicationar mplete,true and correct.
04/12/10
ApplicantDate
Apr 2 10 11 : 36a Midwest Fire Protection I 6123311412 p. 2
p�r>ticr ao/o --eoa`"2 0
acdc-
...f i!'.....,3...,_... . � 'Y,' II .I i!' ry� 4•. .«� , 1.,�,'�, d .,' �''.+.t':7i1: 7..f'Y:'. ... .... (#,-) z -10,
.V�..� ���
•
,0
i k rcr J� ,
qf/io
Flaw l7 i r is
❑ New ❑ Addition Q Remodel ❑ Replace
1 Mite' *.i ***, .700011P,VirMIS
Site Address: 2380 Wayzata Blvd.
Owner: Harvest Moon Co-op Mailing Address: 2380 Wayzata Blvd.
City: Zip:
Home Phone: Alternate Phone:
Contractor/A PP• Midwest Fire Protection, Inc. Contact Person: James A. Kuempel
Address: 324 Harding Street NE State License#: CO21
City: Minneapolis Zip: 55413 Expiration Date: 6/30/10
Phone: (612)331-1411 Alternate Phone:
S .... 1 t I g£i IS S',.t'.,. !..tl... ! µS P: .. iAt1 i T .-....!.., .
Ol Commercial—Fire Sprinkler ❑ Residential—Fire Sprinkler
Fire Systems Permit Fire Systems Permit
*Base Price=Contract Price:$ 7,984.00 x.0125 =$ 99.80 (Minimum$35.00)
*Surcharge=Contract Price: $ 7,984.00 x.0005 =$ 3.99 (Minimum $ .50)
*Mail-In Fee(Only On Mail In Applications) .$ 2.00
*Total Cost of Permit: ..-.$ 105.79
The ersig•ed herby applies to the City for issuance of a Sprinkler Systems Permit. Applicant agrees
at all system. shall be designed,installed and maintained to N.F.P.A-13,N.F.P.A.-25, Minnesota State
Building Code 4 innesota State Fire Code and Standards, and certifies that all statements made on this
application ar:/mplete,true and correct.
04/12/10
Applicant Date
Remi Fpm II
P
4. 4 t1:d
n 136 Rev.O OD
Reliabld Model F1FR
Model F1 FR Recessed 5.
Quick Response
Sprinklers o
Model Fl FR Sprinkler Types
Standard Upright _�
Standard Pendent �„
Conventional
Vertical Sidewall F
Horizontal Sidewall ._
<„ `
— HSW 1 Deflectork.
Model Fl FR Recessed SpY rinkler Types •_ '- �
Recessed Pendent Upright Pendent
Recessed Horizontal Sidewall
— HSW 1 Deflector • �,
Listings &Approvals
1. Listed by Underwriters Laboratories, Inc. (UL)
2. Listed by Underwriters'Laboratories of Canada(ULC) j
3. Certified by FM Approvals r
4. Loss Prevention Council (LPC, UK)
5. NYC BS&A No. 587-75-SA Pttt sc'
6. Meets MIL-S-901C and MIL-STD 167-1 .�
7. Verband der Schadenversicherer(VdS, Germany) Z
8. NYC MEA 258-93-E `�
UL Listing Category Vertical Sidewall Conventional
Sprinklers, Automatic & Open
Quick Response Sprinkler
UL Guide Number
VNIV ,.
Patents: US Patent No. 6,374,920 Applies to " ,_
Model Fl FR Vertical Sidewall Sprinklers.
Product Description Horizontal Sidewall Recessed Pendent
Reliable Models F1 FR and F1 FR Recessed Sprinklers are HSW 1 Deflector (Model FP Shown)
quick response sprinklers which combine the durability of a pands,forcing the bubble smaller and smaller as the liquid
standard sprinkler with the attractive low profile of a decorative pressure increases.Continued heating forces the liquid to
sprinkler. push out against the bulb, causing the glass to shatter,
The Models Fl FR and Fl FR Recessed automatic sprinklers opening the waterway and allowing the deflector to distrib
utilize a 3.0 mm frangible glass bulb. These sprinklers have ute the discharging water.
demonstrated response times in laboratory tests which are
five to ten times faster than standard response sprinklers.This Application
quick response enables the Model Fl FR and Fl FR Recessed Quick response sprinklers are used in fixed fire protec-
sprinklers to apply water to a fire much faster than standard tion systems:Wet,Dry,Deluge or Preaction.Care must be
sprinklers of the same temperature rating. exercised that the orifice size,temperature rating,deflector
The glass bulb consists of an accurately controlled amount style and sprinkler type are in accordance with the latest
of special fluid hermetically sealed inside a precisely manu- published standards of the National Fire Protection Asso-
factured glass capsule. This glass bulb is specially con- ciation or the approving Authority Having Jurisdiction.
structed to provide fast thermal response. The balance of Quick response sprinklers are intended for installation as
parts are made of brass,copper and beryllium nickel. specified in NFPA 13, FM Global Loss Prevention Data
At normal temperatures,the glass bulb contains the fluid Sheet 2-8N or other applicable standards.Quick response
in both the liquid and vapor phases.The vapor phase can sprinklers and standard response sprinklers should not be
be seen as a small bubble.As heat is applied,the liquid ex- intermixed.
The Reliable Automatic Sprinkler Co., Inc. 103 Fairview Park Drive, Elmsford, New York 10523
Model F1 FR Quick Response Upright, Pendent& Conventional Sprinklers
Installation Wrench: Model D Sprinkler Wrench
Installation Data:
K Factor Sprinkler Approval Sprinkler Identification
Sprinkler Type Number(SIN)
US Metric Height Organization
SSU SSP
Standard-Upright(SSU and Pendent(SSP)Deflectors Marked to Indicate Position
X"(15mm)Standard Orifice with X"NPT(R)'J Thread 5.6 80 2.2"(56mm) 12,3,4,5,6,7 83625111 R3615
'X,"(20mm)Large Orifice with X"NPT(R34)Thread 8.0 115 2.3"(58mm) 1,2,3,4,7,8 R362211i R3612
%6"(17mm)Small Orifice with X"NPT(RX)Thread 4.2 60 2.2"(56mm) 1,2,8 R3623(1) R3613
g" (10mm)Small Orifice with y NFT(RX)Thread 2.8 40 2.2"(56mm) 1,2,8 R362111i R3611
lomm Orifice XLH with FIX"Thread 4.2 60 56mm 4,6,7 R3624 R3614
Conventional-Install in Upright or Pendent Position
10mm Orifice XLH with RX Thread 4.2 60 56mm R3674
15mm Standard Orifice with X"NPT(RX)Thread 5.6 80 56mm 4,6,7 R3675
20mm Large Orifice with 3,"NPT(R34)Thread 8.0 115 58mm 4,7 R3672
(1)Polyester coated upright UL and ULC listed corrosion resistant.
I
r tj I.
it
c.�0, :.
Upright Pendent Conventional
Model F1 FR Quick Response Recessed Pendent Sprinkler
Installation Wrench: Model GFR1 Sprinkler Wrench
Installation Data:
Nominal Thread K Factor Sprinkler Approval(1) Sprinkler Identification
Orifice Size US Metric Height Organizations Number(SIN)
X" (15mm) X"NPT(R'h) 5.6 80 2.2"(56mm) 1,2,3,4,5,7,8 R3615
'732"(20mm) X"NPT(RSA) 8.0 115 2.3"(58mm) 1,2,3,8 R3612
XB" (11mm) X"NPT(R'/) 4.2 60 2.2"(56mm) 1,2,8 R3613
X" (10mm) X"NPT(R1/2) 2.8 40 22'(56mm) 1,2,8 R3611
10mm RX 4.2 60 56mm 4,7 R3614
(1)Refer to escutcheon data table for approvals and dimensions.
2 I/4"HOLE DIA—�
F2 5/8"DIA. [66.7mNd
(57.2mmJ HOLE IN CEILING
115/16'OM-�J ..o2 5/16"DIA. [58.7mm)
[49.2mm] CUP
r - r _
I"X 1/2'REDUCER I I 1"X 1/1"REDUCER
TURN COLLAR
aunt TIGHT
ADANTSP TER
WRENCH CH BOSS eoss1
I- I
-I
I .�� I \ _ /
rV11�� FACEAEOF F
ITTTING�TO CEILINGimpb7�i
ALWS+ENr OD,as // /� IOD da M. FACE OF FITTWG
V
I � -1.1
,I TO FACE OF CEILING
IIDIMENSION(I)
"mmJ a k! rea 4 I
2 17„DIA I (1) __ fl_ A"(I)
_. (72.Imm) 136FOOI_f ADJUSTMENT __ __
tI.I6FGOS_A
(I)REFER ro TI!F2 ESCUTCHEON DATA TABLE FOR APPROVALS AND DIMENSIONS (7)REFER TO FP ESCUTCHEON 1:14 TA TABLE FOR APPROVALS AND DIMENSIONS.
2.
Model F1 FR Quick Response Vertical Sidewall Sprinkler
Installation Wrench: Model D Sprinkler Wrench
Installation Position: Upright or Pendent
Approval Type: Light Hazard Occupancy
Installation Data:
Nominal Thread I K FactorSprinkler Sprinkler Approval Identication
Orifice Size US Metric Height Organizations Number(SIN)
1/2" 1/2"NPT(RY) 5.6 80 2.2"(56mm) 1,2,3,6,8
R3685
15mm /2"NPT(RY) 5.6 80 2.2"(56mm) 41 1
(1)LPC Approval is for Pendent position only.
Orientation Deflector to Ceiling
Dimension(Min.-Max.)
Upright 4"- 12"(102mm-305mm)
Pendent 6"- 12"(152mm-305mm)
a.,,
t
Vertical Sidewall
US Patent No. 6,374,920
Model F1 FR Quick Response Horizontal Sidewall Sprinkler
Deflector: HSW 1
Installation Wrench: Model D Sprinkler Wrench
Installation Data:
Approval Organizations
K Factor and Type of Approval Sprinkler
Nominal Thread Sprinkler Identification
Light Ordinary Number(SIN)
Orifice Size US Metric Length Hazard Hazard
}2"(15mm) }2"NPT(R'h) 5.6 80 2.63"(67mm) 1,2,3,5,8 1,2,5,8 R3635
NOTE: UL,ULC and MEA Listing permits use with El or F2 recessed escutcheon.
') A
y a tic r — ��.i
a I, )kIE -/0/..
Ir. �, e A� Jl.:
E r t.� ,r m ,.4 e,,,
ir--_—:.
Horizontal Sidewall - ly— { 'y
-
3.
Installation
Quick response sprinklers are intended for installation as tie vacuuming. Remove any sprinkler which has been
specified in NFPA 13,FM Global Loss Prevention Data Sheet painted (other than factory applied) or damaged in any
2-8N or other applicable standards. Quick response sprin- way. A stock of spare sprinklers should be maintained to
klers and standard response sprinklers should not be inter- allow quick replacement of damaged or operated sprin-
mixed. klers. Prior to installation,sprinklers should be maintained
The Model F1 FR Recessed Quick Response Sprinklers are to in the original cartons and packaging until used to mini-
be installed as shown.The Model Fl or F2 Escutcheons illus- mize the potential for damage to sprinklers that would
trated are the only recessed escutcheons to be used with the cause improper operation or non-operation.
Model Fl FR Sprinklers. The use of any other recessed escutch- Sprinkler Types
eon will void all approvals and negate all warranties.
When installing Model Fl FR Sprinklers,use the Model D Sprin- Upright
kler Wrench. When installing Model Fl FR Recessed Pendent or Standard Pendent
Sidewall Sprinklers,use the Model GFR1 Sprinkler Wrench. Any Conventional
other type of wrench may damage these sprinklers. Sidewall(Vertical, Horizontal HSW1)
Glass bulb sprinklers have orange bulb protectors to minimize Recessed Pendent
bulb damage during shipping, handling and installation. RE- Recessed Horizontal Sidewall HSW1
MOVE THIS PROTECTION AT THE TIME THE SPRINKLER l+)(2)
SYS I EM IS PLACED IN SERVICE FOR FIRE PROTECTION.Re- Finishes
moval of the protectors before this time may leave the bulb vul- Standard Finishes
nerable to damage. RASCO wrenches are designed to install Sprinkler Escutcheon
sprinklers when covers are in place. REMOVE PROTECTORS Bronze Brass
BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS Chrome Plated Chrome Plated(3)
TO REMOVE THE PROTECTORS. White Polyester Coated(4) White Painted(3)
Temperature Ratings Special Application Finishes
Sprinkler Sprinkler Escutcheon
Classification Temperature Max.Ambient Bulb Bright Brass Bright Brass
Sc
Temp. Color Black Plated Black Plated
Ordinary 57 135 100°F(38°C) Orange Black Paint Black Paint
Ordinary 68 155 100°F(38'C) Red Off White Off White
Intermediate 79 175 150°F(66°C) Yellow Satin Chrome Satin Chrome
Intermediate 93 200 150°F(66°C) Green
High(t) 141 286 225°F(107°C) Blue 111 Other finishes and colors are available on special order.
Consult the factory for details.
(11 Not available for recessed sprinklers. (2) FM Approvals is limited to bronze and brass,chrome or black
Escutcheon Data plated finishes only.
(3) FP Push-on/Thread-off escutcheon.
Escutcheon „A, Face of Fitting 141 UL and ULC listed corrosion resistance.
Model Approvals Adjustment p SIN numbers:R3621,R3622,R3623,R3625.
Wail Dimension
1y„ Note: For y" orifice pendent FM approved white
Fl 1,2,4,8 Max Recess (38.1mm) 316°-1.16 polyester coated and UL approved white polyester
Min Recess 3;° (5mm-24mm) corrosion resistant sprinklers refer to Bulletin 014.
(19.1mm)
1y„ Ordering Information
F2 12,3,4,5,7,8 Max Recess (38.1mm) 316°-11161
Min Recess tr,6 ( -17mm) Specify:
(24mm) 1. Sprinkler Model
FP 1,2 "Recessed '/,s l 1y°(38.1mm) 2. Sprinkler Type
Push (11mm) 3. Orifice Size
Thread-off 1,2 Min Recessed (24 m) 1"(25.4mm) 4. Deflector Type
No Dimensional Figure for FP 5. Temperature Rating
6. Sprinkler Finish
Maintenance 7. Escutcheon Type
The Models F1 FR and Fl FR Recessed Sprinklers 8. Escutcheon Finish (where applicable)
should be inspected quarterly and the sprinkler system
maintained in accordance with NFPA 25. Do not clean Note: When Model F1 FR Recessed sprinklers are
sprinklers with soap and water, ammonia or any other ordered, the sprinklers and escutcheons are packaged
cleaning fluids. Remove dust by using a soft brush or gen- separately.
The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association,Factory Mutual Research
Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable
Products manufactured and distributed by Reliable have been protecting life and property for over 80 years,and are installed and serviced by the most highly qualified and reputa-
ble sprinkler contractors located throughout the United States,Canada and foreign countries.
Manufactured by
MOMMOMMINEMMEMEMN_ O The Reliable Automatic Sprinkler Co.,Inc. ® oe
I . e
ab'e (800)431-1588 Sales Offices
(800)848-6051 Sales Fax
Corporate Offices Revision lines indicate updated or new data
(914)829-2042
www.reliablespnnkler.com Internet Address EG PnnteO in U.S.A 3/07 PIN9999970027
Bulletin 157 Rev.E
® Model F3QR
Reliable Quick Response 1
Dry Sprinklers
DJ
CD
Features m
1. The Model F3QR sprinkler utilizes Belleville Spring .,,• •.
Closure Technology. Reliable is the first in the t.' ' t'i:.
industry to produce a Quick Response Dry „ i •,y ..1 '• .., •
Concealed sprinkler utilizing this technology. :..:• .T-1 6•
•
•
2. Styles available : , *;:--7.:!-)'.i--..
.
• Pendent . 'Y.- t.- ,:` z *-
• Recessed Pendent
• Concealed ,�``` •
• Horizontal Sidewall M a-^rx
4
• Recessed Horizontal Sidewall • - 4M•, t,
3. 11/2' (38mm) escutcheon adjustment on pendent Concealed
sprinkler. . - : _ - _ • •
4. 1/2' (13mm) escutcheon adjustment on recessed
sprinkler with push-on/ thread-off FP Model -- .•) ti
Escutcheon ring.
5. %" (9.5mm) cover plate adjustment on concealed ' •`y
r _
sprinkler with push-on/thread-off CCP Cover Plate. � �' "��
6. Attractive appearance. Employs 3mm frangible
glass bulb and galvanized nipple. . - `
• r - -
7. Lengths available to accommodate installation _
dimensions from Z-to-48"(51 mm-to-1219mm), -
in 1/4" (6mm) increments. Recessed Pendent
8. Available in a variety of plated and painted finishes. Z ,.
* s :
U.S. Patent Numbers 5,775,431 and 5,967,240. ms • ' :.
.1-
Approvals .• •.
1. Listed by Underwriters Laboratories Inc. and "-
UL Certified for Canada cULus S n
rinkler 1 Style Response S is em T Haard
Pendent I i .r—
Recessed Pendent i
I CCP Concealed
(R5714) Quick I Dry Pip Ordinary
Light
I Pendent
Horizontal Sidewall 1 All Preaction
l Recessed Horizontal Sidewall 1
i R5734 ;
2. Certified by FM Approvals ' if` ,
Style i Response Sprinkler Hazard ,'� �'�
S stem T •-
I Light `-~�� �' y
Pendent Wet Pi `'
t I Quick SingleInt nock Ordinary, , - u > t
I(R5714) Preaction G iV,-"!" /
Horizontal Sidewall I Wet Pipe, I
(R5734) Quick Single In O I Light
"'
Pr
3. NYC MEA 258-93-E Horizontal Sidewall
The Reliable Automatic Sprinkler Co.,Inc., 525 North MacQuesten Parkway,Mount Vernon,New York 10552
Model F3QR Dry Pendent Sprinkler ' ,
"A"Dim. 2"to 48"(51 mm to 1219mm)in 1/4'(6mm)increments
Finishes") Inlet Protrusion Devoted
Above Maid.Pipe
Sprinkler iEscutcheonF=zz, ---, ___ ____rJVF___
1 Bronze Brass ij . _.'- --1-.-i.- .-
Chrome Plated Chrome Plated ,__ , [__ __
White Painted"' White „ --1. F �
''Other finishes and colors are available on special order. `_= ' System Tee
Consult factory for details. p�
”White painted sprinklers will have chrome plated cans. 2 1/8'Die. p I'NPT
"A"Dimension ..f in[54.OmmaInQ 1111
Adjustment Range
Standard Temperature Ratings .1/4-1.6.•,-m] 1 43/b4'Dio. MI
-1 1/e'(-31.8mrn] [42.Smm] 111I1 1/2"[38._mm]
Tolol Adjustment
Sprinkler Sp iKIN Con i il;;,g, -1 1/4'[31.emm]
Temperature Max. Bulb _,r
Classification ' RatingAmbient Temp. Color IC`=-- '/'"(6.4mm]
.._- 1 Escutcheon
Escutcheon �Ceiling i Adjustment
!Ordinary 135°F (57°C) 100°F (38°C) Orange Q -car..-7
Ordinary 155°F (68°C) 1100°F (38°C) Red -AGNII -?-
(Intermediate 200°F (93°C) 150°F (66°C) Green
lHigh 286°F (141°C) 225°F (107°C) Blue Nominal Position fro [�,3m8"of Escutcheon
1/4' (6.emm]
Protrusion 3" Da
[76.2mm] rvrcm-C
Sprinkler Guard: Model C-2
Sprinkler Installation Wrench Note: The sprinkler Can protrudes 1/4"when escutcheon is
Model G3 Sprinkler Wrench in nominal position. Escutcheon adjustment pro-
Sprinkler Identification Number (SIN): R5714 vides+1/4"(+6mm)to -1h/4"(-32mm)"A"dimension
adjustment range.
Model F3QR Dry Recessed Pendent Sprinkler
l"A"Dim. . 31/2"to48"(89mm to12191rsr1)in'/;'(6mm)increments
Inlet Protrusion Elevated =.7=.7,':---1----t
ti }
---_ ----r-s-, _ -_L`1
Finishes'" Above Inside Pipe Ili Ti 5 _- h1
Sprinkler Escutcheon _aig�--1 N (-- ilL___'
Bronze .Brass ,.r-,_ r-tit
Chrome Plated I Chrome Plated . ,...7_...=
= .' System Tee
White Painted I White ilia_
"'Other finishes and colors are available on special order. Consult 2 1/2" Dia. M.111" NPT
factory for details.Cup remains unfinished.Only the escutcheon (63.50mm] IIIII
will contain desired finish. "A" Dimension Nole in Ceiling
Adjustment Runge
11/4" 2 19/6-4" Dia.
Standard Temperature Ratings [t6.35mm] [58.34mm)
Sprinkler
Temperature Max. Bulb Nominol Position I Sprinkler
of Escutcheon Cup Assembly
Classification Rating Ambient Temp. Color
Ordinary {135°F (57°C) 100°F (38°C) Orange Kr
�i Escutcheon
I Ordinary j 155°F (68°C) 100°F (38°C) Red cei"ng ' r _IIntermediate 200°F (93°C) 150°F (66°C) Green ! rir Ceiling 1,
High' 286°F (141°C) 225°F (107°C) Blue I __
1/4" [6.35mm] i i
Escutcheon Adjustment
1/4" [6.35mm] 3 7/32" Dia._.]
'Listed and Certified only by cULus Escutcheon Adjustment [81.76mm]
1/2" [12.7mm]
Total Adjustment 157FCO2-C
Sprinkler Installation Wrench
Model G3 R/C Sprinkler Wrench Note: Do not install the Model F3QR Dry Pendent
Recessed Sprinkler in ceilings which have positive
Sprinkler Identification Number (SIN): R5714 pressure in the space above.
2.
'Model F3QR Dry Pendent Concealed Sprinkler
"A"Dim. 3%"to 48"(89mm to 1219mm)in 1/4'(6(rm) increments
Inlet Protrusion Elevoted
(1) (2) Above Inside Pipe
CCP Cover Plate Finishes r_ r
Standard Finishes Special Application Finishes r - F. -4-�
Chrome Plated Bright Brass Plated ',=__a, .--J NA r1---ii='
White Black Plated ter' ti
Black Paint _-_ System Tee
Off White
Satin Chrome lilt.i"' Utilizes the, cover plate with%"total adjustment. ' NPT
"
" Other finishes and colors are available on special order.
Consult factory for details. 2 1/2" Dio.
[6.35mm] II 1
"A• Dimension Hole m Ceiling
Standard Temperature Ratings Adjustment Range 2 19/64 Dio. II
l
± 3/16"
1 Sprinkler I [±4,76mm] [58.34mm]
Temperature Cover Plate Max.
Classification Rating Temp.Rating I Ambient Temp. Nominol Position
of Coverplote Sprinkler
!Ordinary 135°F (57°C) 135°F (57°C) 100°F (38°C) Cup Mxmbly
Ordinary 155°F (68°C) 135°F (57°C) 100°F (38°C) _ _ _moi Coverplote
':Intermediate 200°F (93°C) 165°F (74°C) 1150°F (66°C) Cailing "�,, Assembly
;High' 286°F (141°C) 1165°F (74°C) 1150°F (66°C) ,....7..!!!_
al�.1 r ceiling?
I__Aid _
3/16` [4.76mm] IrilliV
•
"Listed and Certified only by cULus. cowrplote Adjustment
Note: Do not install the Model F3QR Dry Pendent
Sprinkler Installation Wrench: Concealed Sprinkler in ceilings which have
Model G3 R/C Sprinkler Wrench positive pressure in the space above.
Sprinkler Identification Number (SIN): R5714
Model F3QR Dry Horizontal Sidewall Sprinkler
l"A"Dim. 2"to 48"(51 mm to 1219r n II)in 1/4"(6mm) increments
Finishestil1/2" [38.1Dmm1
l _.__ total Ad:ustmenl
!Sprinkler Escutcheon •i r__; 1-r.._..____.._.__..-'F
Bronze 'Brass 3 [101.60mm Mir,.
Chrome Plated ;Chrome Plated _•J L ] 12" [304.80mm) Mo.
p 1 1/4" (31.75mm]
I White Painted' White Escutcheon Adjustment '
1„ t.� 1/4" [6.35mm]
Other finishes and colors are available on special order. system Tee . 1 IEscutcheon Adjustment
Consult factory for details. 1" NPT i k [•'6
'11 White painted sprinklers will have chrome plated can. 1.____,, r\ 53 183mm
2 ' � 111111111 it __ �° 3
Standard Temperature Ratings � 1111111141 or----L. [76.20mm)
I Sprinkler - -`= �� _
I Temperature Max. Bulb 2 1/8" Dio. I , 1
I Classification Rating Ambient Temp. Color [53.9dmm]
I Hole in Woll L'•� 1/4" [6.35nun]
IOrdinary 135°F (57°C) 1100°F (38°C) Orange Protrusion
Ordinary 155°F (68°C) 100°F (38°C) Red Sprinkler Con
Intermediate 200°F (93°C) 150°F (66°C) Green "A" Dimension Nominol Position
286°F Adjustment
l High !286G F (141o C) 1225o F (107o C) Blue r11,Go.-c Range + 1/4' (+6.35mm] of Escutcheon
Sprinkler Installation Wrench: Note: The sprinkler Can protrudes 1/4"when escutcheon is
Model G3 Sprinkler Wrench in nominal position. Escutcheon adjustment pro-
vides+/4 (+6mm)to -11/4"(-32mm)`A"dimension
Sprinkler Identification Number (SIN): R5734 adjustment range.
3.
Model F3QR Dry Horizontal Recessed Sidewall Sprinkler . .
"A"Dim. 3Y2"to48"(89rtrn to1219rrm)iiW(6mm)increments
I-----'cainy-
Finishes"' Li--
Sprinkler !Escutcheon E,cutcheoo ( "n32
Bronze 1 Brass r' 4 [,o1.6mm]M,n.
Chrome Plated Chrome Plated System lee `°° I s I 12 `w+.emm].,..»
White Painted White 1-MP,
1' Other finishes and colors are available on special order. Consult ;\-1-.` MM�factory for details.Cup remains unfinished."See page 2" it i11��l 1____ �l+ /" /11111111 �•I 3 7/32•a°.
��r [BI.Bmm]
�- ___�___• 2 1/2'Dia. = • •"1 1
[63.5mm]
MWe in WWI I
2 19/64•D"o. Li'(SB 3mm]
Standard Temperature Ratings •A-Dimension 1/2 [t2.7mm,
Adjustment Rape Escutcheon Adjustment
r31rf0, •1/2•-0
Sprinkler j [+t2.7mm -0]
Temperature Max Bulb
1 Classification i Rating Ambient Temp. Color *, FOR FACTORY MUTUAL(nu)
• - A roil MT
s LaoRAiOR Es NO
]
Ordinary I 135°F (57°C) 100°F (38°C) Orange
Ordinary 155°F (68°C) 100°F (38°C) Red
Intermediate ' 200°F (93°C) 150°F (66°C) Green
High- 286°F (141°C) 225°F (107°C) ! Blue Notes:Do not install the Model F3QR Dry Horizontal
* Listed and Certified only by cULus. Recessed Sidewall Sprinkler in walls which have
positive pressure in their side space.
• Listed by cULus for Quick Response.Approved
Sprinkler Installation Wrench: by FM for Standard Response.
Model G3 R/C Sprinkler Wrench • Recessed Horizontal sidewall sprinklers are listed
with cULus for installation of min.4"(100mm)-to-
Sprinkler Identification Number (SIN): R5734 max. 6"(150mm)below ceiling and approved by
FM for installation of min. 4"(100mm)-to-max.
12"(300mm)below ceiling.
Technical Data: Ordering Information
Orifice Size: 1/2" (15mm) Specify:
Thread Size: 1" NPT per ANSI B2.1
Working Pressure: 175 psi (12 bar) 1. Sprinkler Type(select one):
Nominal K Factor- US/(Metric): 5.6/(80) (a)Model F3QR Dry Pendent
Product Description (b)Model F3QR Dry Recessed Pendent
Reliable Model F3QR Dry Sprinklers are quick response (c)Model F3QR Dry Concealed Pendent
sprinklers utilizing a durable 3mm frangible glass bulb. This (d)Model F3QR Dry Horizontal Sidewall
quick response enables these sprinklers to apply water to a (e) Model F3QR Dry Recessed Horizontal Sidewall
fire much sooner than standard response spnnklers of the 2. Sprinkler Temperature Rating.
similar temperature rating. 3. Sprinkler Finish.
Model F3QR Dry Sprinklers are intended for use in enclosed
dry and preaction systems and in enclosed areas subjected 4. Cover Plate/Escutcheon Finish.
to freezing temperatures, such as freezers and unheated 5. Length:
portions inside buildings. "A" Dimension(face of tee to face of ceiling or wall)
Environments wherein dry sprinklers are employed can be in 1/4"(6mm)increments.
corrosive.For this reason,Model F3 Sprinklers have a special
wax fillet placed in the gap between the cup that supports the 6. Model F3QR Dry Pendent(a)is available without
bulb and the wrenching boss.This wax will not interfere with sprinkler can and escutcheon.
the operation of the sprinkler, and it prevents contaminents
from entering the internal portion of the drop nipple.The wax Note:
must not be removed.
Operation 1. The "A" dimension is based on a nominally gauged
pipe thread "make-up" of 0.600" (15mm) per ANSI
The glass bulb consists of an accurately controlled amount B2.1 [71 threads approximately].
of special fluid hermetically sealed inside a precisely 2. All platings and paintings are decorative and
manufactured glass capsule. This glass bulb is special
constructed to provide fast thermal response. When theintendedfor interior use.
temperature increases sufficiently, due to a fire, the bulb
shatters allowing operating parts to clear the waterway. This
enables the inlet seal to release air or water and subsequently,
cause water flow over the deflector in a uniform spray pattern,
controlling or extinguishing the fire.
4.
•
General Installation Instructions the bulb supporting cup and the wrenching boss. Do not
In steel pipe, the Model F3QR Dry Sprinklers must be replace this wax with a substitute substance.An Alternate
installed only in standard (ANSI B 16.3 class 150 and - substance may interfere with proper operation of the
ANSI B 16.4 class 125) pipe tees even at branch line sprinkler. Do not clean sprinklers with soap and water,
ends. For these and CPVC* Tees, the dry sprinkler ammonia or any other cleaning fluids. Remove dust by
should be installed and confirmed to have appropriate using a soft brush or gently vacuuming. Remove any
protrusion into the tee in accordance with the figures on sprinkler which has been painted (other than factory
pages 2 & 3. Dry sprinklers must not be installed into applied) or damaged in any way. A stock of spare
elbows and into pipe couplings located on drop nipples sprinklers should be maintained to allow quick
to the sprinklers. The "A' dimension of a dry sprinkler, replacement of damaged or operated sprinklers. Prior to
which extends into a freezer from a wet pipe system, installation, sprinklers should be maintained in the original
should be selected to provide at least 14" (356mm) cartons and packaging until used to minimize the potential
between the freezer's outside wall or ceiling and the wet for damage to sprinklers that would cause improper
pipe line. When the temperature inside the freezer will be operation or non-operation.
below-30°F(-35°C), increase the 14" to 20" (509mm).
1. Cut the specified size hole (see illustrations) for the
sprinkler in the ceiling directly in line with the tee. *Spears CPVC sprinkler adapter tees(with steel thread
2. Apply pipe joint compound to the 1" (25mm) pipe insert) can only be used with horizontal sidewall
threads and install sprinkler using the Model G3 or sprinklers which do not require protrusion into tees to
G3 R/C Sprinkler Wrench as specified. prevent ice or debris blockage of sprinkler inlets. These
3.Install the push-on escutcheon or coverplate. CPVC tees do not permit sufficient sprinkler inlet
P protrusion as required for pendent installation.
Note: Installation of the Model F3QR Sprinklers in
copper pipe systems is not recommended,
as this may reduce the life expectancy of the
sprinklers.
Model F3QR Concealed and Recessed
Installation Instructions
• The Model G3 R/C wrench(Fig. 1)is designed to locate
on the wrenching pads of the recessed sprinkler while
centering in the cup. A standard 1/2" drive ratchet may
be used to drive this wrench. Figures 1 and 2 show
sequentially the insertion of the wrench.First the wrench,
with its jaws above the sprinkler deflector, is moved
laterally until centered with the cup. Then raise the
wrench inside of the cup until its jaws engage the
sprinkler's square wrenching pads (Fig. 3). To remove
the wrench,follow this procedure in reverse order. Care
should be taken to avoid striking the deflector, with the
wrench.
• Model G3 Wrench (Fig. 4) is used for installation of
Pendent and Horizontal Sidewall sprinklers.
• Glass bulb sprinklers have orange bulb protectors to
minimize bulb damage during shipping, handling and
installation.REMOVE THIS PROTECTION AT THE TIME
THE SPRINKLER SYSTEM IS PLACED IN SERVICE
FOR FIRE PROTECTION. Removal of the protectors
before this time may leave the bulb vulnerable to
damage. RASCO wrenches are designed to install
sprinklers when covers are in place. REMOVE
PROTECTORS BY UNDOING THE CLASP BY HAND.
DO NOT USE TOOLS TO REMOVE THE
PROTECTORS.
Maintenance
The Model F3QR Quick Response Dry Sprinklers should
be inspected quarterly and the sprinkler system
maintained in accordance with NFPA 25. Do not remove
the factory applied thermally sensitive wax fillet between
5.
•
A
rite
4 a
t i
Fig. 1 - G3 R/C Wrench Fig. 2 - G3 R/C Wrench Fig. 3 - G3 R/C Wrench
tillq1111
-17
•
I ,
� -��7[� Baa•
•,•.ty
Fig. 4-G3 Wrench
The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association.Factory Mutual
Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.
Products manufactured and distributed by Reliable have been protecting lite and property for over 80 years,and are installed and serviced by the most highly qualified
and reputable sprinkler contractors located throughout the United States,Canada and loreign countries.
Manufacturedb
The Reliable Automatic Sprinkler Co.,Inc. Recycled
Reliable Paper
(800) 431-1588 Sales Offices
(800) 848-6051 Sales Fax
(914) 668-3470 Corporate Offices Revision lines indicate updated or new data
www.reliablesprinkler.com Internet Address E.G.Printed in USA 6/05 P/N9999970175
• ' ''
..-..;---
allied
.... ___
.,....._ _
TUBE & CONDUIT
-,. w.
V.
1.• 11,,,,
...,
; .
t .,'•'`if, '
1 •._:'; 1. •
I .
mag •
CO ,.". • .
TEl i
. ...
...,_-._ -
7---.- ..
: .
. .
• .-'-;,:-.:-..... ."'-' .,
...., .
. • . ,- '....4.'.i.i.:'.. ., ..:
tga. .. . .,...••:.-...••••...-.:..- ,;
, . ....,:.-...‘..•.;,,,.-,,,,,, I
. ..
, . • .....,---,,,...
....
. '117 •7:*11:,
. . r
,. ..
. r
':,,-• '.' -. : - : A ....?...ii:Li=;;-..-:.7;Fc.0..'i:
'....4-1, .,.. .
-...•.::- .,. , „..._..
•
. ' :' '• . :.....,z;.i ,'....Iv
' - •."...:1-.....-',-.z.',,,•`-i:, ,,"4-,,.
1 : f
*-4 1
. ' . ‘ ';;:."...^r',:*:.::'-',V21 '''"j';',:::0k• a . .,
.:•-...',
. • .. • ,.....1.....,14'i!'!.k' ,.
•.: i :; ''': ''s..'''.. :1 ' :li: ' ' . . . . . '; — :., ....d•r.,-„, -7,,'t...41-:• :,::-*•,tiVt'•
-••:-:•,, ••: . • ,,.„ .' • - ---: '• 012-,.... -,-: 4-‘,.2•:•:.-i‘g,,,,.:V-•
•,,..„,-.. - ,- • . - - - •-•.•.. , z---- , • •,-,,..4...4.-e*F-,--. ,
. .
. ,
. , . .. . . _ •
. . .. . , . ,,..
V . .4 . ... •.-..
. .,, -,, . . .!,:..-:2-;. .i :- -.,,,,,, :;4,`:,•;;:-..c,,,e...4,,,-,......!:t :, , ..$„•--ii.f.;.,::'• •:- 1
7ii. •,,•...?;•,..?..:1,,,,-,2.7i,-k•;•':;-...•-:•.-.'
- ---• •---.,•; ,••• •• • - ..•?.01..-;,...r-•.--!•••• .;• •• • 4,,..•4•••-•• •.',--.4%.:
•
... -:,, -•: -;: • .i.•;•--17.-40.:;,;•:::::,,-c• . •••,•••.• ••••• -...,,k....:,•; • -• •-•-.-•.,-4-14-ti„,i;••••
-.4 -.:-2.,,..,•,••••-•,-;•.-:::;z•;;....•-•.;-;;.,---4,.....•.
• - • •• - • k'''i''1.,'"'",,,,,,44•!,:7i. ...
:......,2'..',.:'.4.., Y...::..•:':'-''''''''';..i.4: '''''''' .., '..e.41::,,,' tit ..LAt;','*':<-. '' -,''..i."-s.'''"'',"' ';- ''.'....'-'..,...'',. 4 .i•• ••,.7• - :''''• '-'-'.•:••
•;,:....•..4.°,..:::..-:;„:.:;ri•c-,.. .-"!;*if,S ,", ' ' ''.4',,s.,i;:,''',,i: ijik:: ''';'-.. :,.. ;Zr-:'- -- '- .', - . ', ''.'''' 47.", '''-''''''''.. -:' .:'' ' ': '.:'
',•....'''..i;4.Y.,T'''-'-'4 1-1:.1.7 '. '7':' :;-,',',?'',..4:- •:,:',.,,t0 ti,, . . '- ': .': '
„ .
'' lam: • ' ' ,,`
'•• ','..''.' '• ,',4 ' '
., .
,
s ,.
, .
• -
•,
''4,,,•
bar
,..•
aftd! •
• - ''•
, • •••. ,-,...-
.,. ,
_ .
i•
'N§k• ''''':i':;:: .-:-- ' '''•'.'2,
......-
''''''''1.: .''":..g'.•..,-••'',7-...:
- i••,• ?,,...
.,,,,, •
-•
-••••,-,-4..,..
.... .
_._ .
...„
...
•
sob
. ..., ...
.. , .
- .. .,,, .... •
-; .,...,...k.....:•.-•
')''' ;Ili?' '•
vd
...-Iiii—• '' --...„ .
,51pJ ..," pt-C /0./7-,.
...
0
BLT
. , ,
XL°/BLT°
Galvanized and Black Lightwall Threadable Pipe
The original "Galvanized"and "Black" Threadable Lightwall pipes with exceptional hydraulics and economy.
XL®/BLT®'s proven hydraulic Specifications
advantage and lighter weight adds value NPS Nominal I.D. Wt. Wt.(H20 Filled) Pcs/ Wt/Lift(21') Wl/.ift(24') WIJlifl 25'
to any system.When you need a proven ( 1
sprinkler pipe,specify XL/BLT. In;mm /n;mm Lbs/Ft;Kg/m Lbs/Ft;Kg/m Lilt Lbs;Kg Lbs;Kg Lbs;Kg
1' 1.104 1.13 1.61 91 2,333 2,667 2,570
XL/BLT pipe are an exceptionally 25 28.0 1.8 2.40 91 1,060 1,211 1,228
strong steel sprinkler pipe of the class 11/4' 1.452 1.46 2.25 61 2,019 2,307 2,226
generally known as"lightwall 32 36.9 2.3 3.35 61 917 1,048 1,058
threadable pipe". Its wall thickness is 11/2' 1.687 1.76 2.84 61 2,409 2,753 2,684
less than that of Sch-40 or Sch-l0,but 40 42.8 2.8 4.23 61 1,094 1,250 1,294
the cold forming process undergone in 2' 2.154 2.35 4.06 37 1,959 2,239 2,173
manufacturing gives XL/BLT pipe 50 54.7 3.7 6.04 37 890 1,017 1,041
mechanical strength characteristics 21/2- 2.581 4.08 6.34 30 2,571 2,939 3,060
equivalent to those required for Sch-40. 65 65.5 6.05 9.45 30 1,168 1,335 1,390
It is designed for use in wet,dry,
preaction and deluge systems.XL/BLT 3" 3.200 5.01 8.49 19 1,999 2,285 2,380
can be joined with threaded couplings 80 81.2 7.43 12.7 19 908 1,038 1,081
(when in accordance with ANSI
*XL only
B 1.20.1),roll grooved or plain-end
couplings,or welded joints.
XL/BLT products have metallurgical XL/BLT pipe is manufactured to meet XL/BLT pipe offers the_maximum
properties which provide excellent ASTM A-135,Grade A for fire hydraulic advantage of any available
fabrication characteristics for end prep sprinkler applications up to 300 psi threadable sprinkler pipe. Its inside
finishes,welding and roll grooving. No working pressure. diameter is up to 5%larger than Sch-40.
special process or equipment are needed The use of XL/BLT in conjunction with
for fabrication and installation. ® ® ® Dyna-Flow pipe,can dramatically
improve the flow characteristics,
XL is manufactured with galvanized therebyincreasing the potential for
coating. Listed Approved Listedncreasg
"downsizing"system components.
BLT is black lacquer coated. It is UL listed for wet,dry, preaction
and deluge systems,and FM approved
The internal surface of all black Allied for wet sprinkler systems. XL/BLT is
Tube&Conduit Fire Sprinkler pipe ULC listed for wet,dry and preaction
products up to 4.5000"in diameter is systems.All threaded and welded
coated with our new Antibacterial fittings are approved in accordance with
Formula,"ABF". In scientific laboratory NFPA 13.
The clean surface quality of XL/BLT is
test,ABS proved to have superior
resistance to microbial colonization of FM requires 12' maximum hanger readily paintable. The lighter weight of
pipe walls,thereby delaying or possibly spacing for XL/BLT. C-Factors for XL/ XL/BLT is a distinct advantage for
retro fit installations and can also
BLT are 120 for wet systems,and
preventing the onset of C=100 for dry systems. Refer to Hazen- reduce labor costs.
Microbiologically Influenced corrosion Williams charts for accurate flow
(MIC)when the First Sprinkler System
is first installed. comparisons.
VICO/Flow ControlT
allied 16100 S. Lathrop• Harvey, IL 60426 Customer Service:
11350 Norcom Rd. • Philadelphia, PA 19154 (800)882-5543
TUBE S CONDUIT 2525 N. 27 th Ave. • Phoenix,AZ 85009 Fax 708-339-1806
S4-3
.... „ .. .
„. ,,-..-..'' .... . •
„ .. .
• •
.. ,. . , • .. . _ .
®
allied
ii:'...,:',...:'..f.•.:...,,,_..-.,..,„..1
,. . .. . ,. ,. . .. .. .. , .. •., .. . .
‘. . ... . , .
.,... • , .- .
7i, •:.:.,;-"r;;:„:..r...•:;,.,..7.-k.--31*.fi,•!'•,... ,..•,,,..•;;::,'••••••,,..., r,..„ ,.;.,..,„-.'.----,..-'......`-:-...-',.. ..
•,•,,'''.,' '-.. .,•:,,-;:,..:,:ti.,/.10t.-
:- ,.'-'-..,.V't,kj.: • •-....4-,:".P. t.1.,,fiit:-,'•-•,'"•4; 44.i:...;,•:.:,,;N3t•f•.„ -•,. .Th--,...,-.:....-. •-,,.•
gs,.!..'.1.:.,.4,•- .,•„.;.-1,-,-..'..' a — ,.7':,•,-,',-'''';' .' - ,, .....::..,t..?•!•,i..t?7,,, -,-;.1.1..f,,;•:',.' '.-.'..,. "'..,,t-,;.': '' ..., .• ', .:',...;.'..:' .. - . ,',•••,w14,51..:2,-4.!'
,1%;••Iziy,;:F'.:..f...,,,, .F1-.,:: ' a ' rah.... •,%••••.,. ;*,• ,,,,.....,i,,,,...-„?.!4„,r,,,,,,,,,•-•. ,,;••,,,,•• -,, •,.••••••.• •, , : -.. •:, „,:„ ••••244*-,,,„.„,,,
';'•••.A!..1:,-,..,.•':'-11:':''''.:',,,•15;::7':‘''''' .. 4.'-'-',`;,',.''.:.;e2;•,;,,..4,4p.i... ...,: ..,:::,.:,:,,::: ,,,., : , _.ii,,,, ‘,,,,,,,, ,,,,•,.., T::: 34.,_ ._,CONDUIT ,
4',;':--,44!.,:t:-„,,,,•••-••,,,,••?..,,•,,,,,„ -, tr, - ',•••••••••,:,..•.-,• , 4 :4 ‘-:-:•‘.1 -•••••• ' •-•-'• '----•; ' * ,'•• -2'2- ''• ••••,.:•,,,'-'-'-',-• - '• ' ',
,•• ,-,.-,. ... •• ••••••ii.•„: • 7' '',:k •H ••••?„ ' • 1.1 -''••t;' :;-' i -:::',:,, . '- i 1';',*, ite„."['-',..-• 2•4•'•""'•''.;'•'7.-`';';:,
'')•' -'''-.'..:-..:,:. - ''• . .-',..i.J,. MI '''.. " . : ',' ''., '''4r ;..- C.'7,7, 4,''''-.%i i'''. . P;:::'',r,,-, t" ' '•'41;.. .'-:',"-:' ' ;
D:';'•-•:...'f:i.--.... ''''.:.* Z ,..:,,'. '-. .' ' : IS ';'t.''' ;•.1:•,-;.'i 1' J'''''''r . .',!,'7.:
.ti.t. '.•:4.",.:,-'.•'..•':..:'.... '''::": Iti & '...i.:,..'''',':: CI . '':>;:::•••:t ...:?. ‘,0:',`;:s .,.,.-',:.i',, .,,:......:..;;',..'i !,.1,..'.4:-
":1..ti-i'.:1,i:;,.k'. ,'. ,• ..: —,., 4 :4 ,'2:4,..,..'t.,,,*;; . •
41......,!1,i..,',..;• : .:, • i
, . . . ....
Va-ili.,. ..k.'`..,:-;,..:-.-,..••,.... ti. ..".•`.''.4.' ; . „
- •• - - ..,.. ., .. ,
,,........,... ,-.-.:.,-,..: -. .
•. *"...".44,zi,7ilk•-••'•:: y
i , 1.1,•,..,,,,,,,,.,,,,,),,,,,,,„,,,.. -.,,,-
...,•.•4'.h.,',tilit,WAIE.'',',,,T''.
-*.t.40,444iFi', ',.,(•,:;
yvT0,4',.,4:04.t,-..-•.- .!,A,, ,,,...,„ ..
... . ..... .
...* 5,-„,.....
-,v, .!,-..*:., •
•Ai •••••.,.••,,•,,t •
.1.1,4, -,-,...,•;,...&:,
1,16, ,•• •:.-„,,,,,-,' ilt „., :•,,-,-.:,,,,.s , ••:'
...• •. • -4,2„,,,,,,,,,, ,.....„........••• • .;
' ::•-'3 v • ••:• ;••,•!•'.7•'" t .'. -..'-;',.',,, , . 4.'..71'.4 .•':,'. .', ..,i
. , .
R,-4,,,,:-Iit3ot .'4'::::-•
Et ;;-r 1 '.!.;:":if,-.
if-1-".;:;;;;1.4.:!,.044:;,;'`''.-.•* ,....,.....
'":";,,. '','•'414 •:,-
•T T• T '
. _ ....
.. ...
,. - - .: '• ''.. r 7,,::,:'41,,,ti-.- ,,:'::.•
t,,V,,tc.kr.:•,..',-1.::,::,' 1-:;- t,•-•',..T1 • •„. .-' .
... ,•, . .
. t ..
. • ,.,..
,1::::.:1: 11',":..k,:.-:.;1, .. .. „ • ,,......., ,,, ,,
• ... .. ,
.::.:
0'',:i4 ,0*, 4'.
.k,..„.',-T•.,N:,,,,,...N.:,-2.,... „.1, r:-.;,„:„-'5:, ...' 4 ., t, •••,., , .
.. •.,• - -„Ivilin-1,-,,,,,,,
•-,.‘„Nk'•• 4..••,---%•14, ,,•14.1i: , ..._ •!.,?-J 1--„,.-•.-se.,..„ ,,, . ....-„.•.,•,, • „ ••.„,
••••:-7'•,;-,'''•'.1•Ns1-1',4-, ••••• s ••,'„ 1,'.•,•:',,•••••.:- •••'' a '•illl ',‘•••.,:•,!• ., • ,
• , • •,:, ..
.:•'.';,,,i.:,,,,-7.•';•-•',ii,,-44;-'1;„:4*.r• ia ••• ,I.V.:. - raiz ••-•.•\-.• A
. • • .„
••• .•. ,. •• •
: ',- ••••••,.;•,,,,,,,,,,,;•„,-,,s.
.• •••,„„•„-,•,,44,,,,,,,,,
,•.,,,,•••••„.,,,,,•''.*4,,,,••••„...'..,-.4 1441 ' H.q.,f,-.,` 4 •,:::-:,3'. ,,•J•A• . , , ,., •
Ai..•••1,,,,,,,•;•-„„?.,,,I,-••••,•••.• Lk . . i,..•:•••:.:;.. at .,t,,,...k. •,...,.f
: j.,,•. t„:„
. . .. .. ,,....., .
.:.,......
-'.• •'• • '''''4'''
,,,. ...-..,?,.6,....,,,,..,,,,....,......
4,•••, -.,i,,,,,,i7,4„,-,Ait-ts:,•••,•-,•••••• •A_ •••• ,•••••••,,-,,;„-- a •• 4.:.„. „. •
•••„tv•,,,,„,-*-394,„,••• ,1%, ,-. ;•••••••••,-,,F* „ •.*. ;.. - .
• , •••• •
0 '• ,
. . ,
.• „...„
T.N.i.„,,•._4-„,•,,•:1-,-,,•,e••=',..• t ,..:••,• '.• '—'„ --1 : •':•.,•-• ' ' , . '• k • , ....,
: ..
k„.... ... _ . ,„
. „ .
a• „ ,. lib
'• ''' • ,...„.:. 4 Ai , '• . ;,
! •••••
a : ••• ,• ..,
I4,,:' '•• • 1
, •••,.•
;.•••i
-':--',.•••••'• •, ,
- • ;..... •-- , ati •
. . •,—
....„,
•ii- '''. - ilk ;•'•!..' ‘. ft „' . ,
. ,..,
14: .';,: 4 . . ,.•
,.
—„
,'•;"'..,,.-,:?..i','„:0;.':•.4, . - -,,
, .t...' .'•,... *, T.'. ,,' ' Q ,:....'"-... : ., .,„,.
.•,W” I
,..
r.t,
tt.t
1".1*
At .
t t.tt
tt
, .
s..3 .: •t
AS '... I.•
,:z• ,
a .•
Lft , •
A' •
M -.1
p..,,
•.,4,1
a
t :
g
bbi . iga
k a ii;
....
th
414,
...
...,
Lt
'•;;'.2. ,,. „
•.,-4...,f,,;.„.:,•-?••,k•
,,,-,.•,„•-. 41)193p4Are.' se.e, /
,, Igts
„qtifilb
i
If
,.. ,,,......
1-i ,BF ,
. ,. .
,','• ,-•,,•ToPec....•
.,.,
.•, ..
• •• --• ...,....-....„....
DY nil A - FLOW ®
Dyna-Flow® VI . �W ..
High Strength Steel Pipe
The original high-strength lightwall sprinkler pipe with hydraulics superior to Schedule-10.
Dyna-Flow pipe is the"original"high- Specifications
strength lightwall sprinkler pipe. Dyna-
Flow has outstanding hydraulic NPS Nominal I.D. Wt. Wt.(H20 Filled) Pcs/ Wt/Lift(21') Wt/Lift(24') Wt/Lift(25')
capabilities and is recognized as the In;mm In;mm Lbs/Ft;Kg/m Lbs/Ft;Kg/m Lift Lbs;Kg Lbs;Kg Lbs;Kg
most popular alternative to Schedule-IO 1' 1.191 0.830 1.31 91 1,586 1,812 1,888
pipe. Lightweight,easy to cut and easy 25 30.3 1.2 1.95 91 719 822 856
to handle for installation. Dyna-Flow is a 1W 1.536 1.059 1.87 61 1,356 1,550 1,615
valuable addition to any fire protection 32 39.0 1.6 2.78 61 615 703 733
system. 1W 1.728 1.667 2.71 61 2,135 2,440 2,542
Superior Hydraulics 40 43.9 2.5 4.03 61 968 1107 1153
2" 2.203 2.104 3.79 37 1,634 1,868 1,946
With an inside diameter of up to 11% 50 56.0 3.1 5.64 37 741 847 883
larger than Schedule-40 and up to 7% 2W 2.703 2.564 5.10 30 1,615 1,846 1,923
larger than Schedule-10, Dyna-Flow 65 68.7 3.8 7.59 30 733 837 872
pipe hydraulics are exceptional. Larger 3' 3.314 3.387 7.18 19 1,351 1,544 1,608
I.D.s enable Dyna-Flow,and related 80 84.2 5.0 10.69 19 613 700 729
components,to be down-sized within the 4' 4.310 4.473 10.86 19 1,784 2,039 2,124
system, thus increasing the potential for 90 109.5 6.7 16.16 19 809 925 963
job cost savings.For complete Hazen-
Williams charts,refer to"Dyna-Flow
Hydraulic Data Tables."
Coatings & Fabrication Specifications & Approvals Additional Benefits
Dyna-Flow products are coated with Dyna-Flow/Super Flo pipe is manufac- • Lightweight and easy to install,
an environmentally approved and tured to meet'ASTM A-795 Type E, resulting in more efficient use of your
specially formulated modified-acrylic or Grade A and is in compliance with freight and labor dollars.
water-based coating. This durable coating NFPA-13 and NFPA-14.All sizes of
is paintable.The black coating acts as Dyna Flow/Super Flo are UL Listed, FM • Provides stability needed to comply
Approved and ULC Listed. with standard hanger spacing
an excellent primer and is resistant to pp (15 ft O.C.)per NFPA.
weathering and U.V. degradation from
outdoor storage. t ® ® • Available in Standard lengths for your
Metallurgical properties provide excellent Listed Approved Listed convenience,or can be ordered in
fabrication characteristics for end prep custom lengths upon approval.
Dyna-Flow/Super Flo is UL/ULC Listed
finishes,welding and roll grooving. for use with roll grooved, plain-end • Fast cutting and welding,as well as
There is no special process or equipment couplings,and welded joints for wet, dry, easy roll grooving and end preparation.
needed for fabrication and installation. preaction and deluge systems. It is FM
The internal surface of all black Allied Approved for roll grooved,plain-end,and • Available in Factory roll grooved form
Tube&Conduit Fire Sprinkler pipe welded joints for wet systems. Refer to for quicker shop turnaround.
products up to 4.5000" in diameter is appropriate documentation for up-to-date • Clean,durable mill coating provides
coated with our new Antibacterial listing and approval information. Dyna- longer"shelf life"and acts as an
Formula,"ABF". In scientific laboratory Flow/Super Flo is now available"hot- excellent primer for custom paint
test,ABS proved to have superior dip"galvanized and has been specifically applications.
resistance to microbial colonization of approved by FM for dry systems uses.
pipe walls,thereby delaying or possibly
preventing the onset of Microbiologically
Influenced corrosion(MIC)when the
First Sprinkler System is first installed.
*fl'iCO/Flow Control IIcJ
16100 S. Lathrop• Harvey, IL 60426 Custome'r Service:
` / 11350 Norcom Rd. • Philadelphia, PA 19154 (800)882-5543
TUBE 8 CONDUIT 2525 N. 27th Ave. • Phoenix,AZ 85009 Fax 708-339-1806
S2 - 3