Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2006-P00174 - alarm system
CITY OF ORONO ®®11111111111111111111111113 2750 KELLEY PARKWAY * 2 0 1 2 - 0 0 1 7 4 DATE ISSUED: 03/19/2012 ORONO,MN 55356- 952 249-4600 FAX: 952 249-4616 REPRINTED ON 3/22/2012 ADDRESS 2605 WAYZATA BLVD W PIN : 33-118-23-13-0015 LEGAL DESC VAN DALE ADDN LOT 000 BLOCK 000 PERMIT TYPE FIRE SYSTEMS PROPERTY TYPE COMMERCIAL-BUSINESS CONSTRUCTION TYPE ALARM SYSTEM NOTE: INSPECTIONS ARE DONE BY FIRE MARSHALL,JAMES VAN EYLL. PLEASE CALL JAMES VAN EYLL DIRECTLY AT:(952)473-9701 TO SET UP AN INSPECTION. ADDITION TO FIRE EXTINQUISHER- ENTER CONTRACT PRICE 1586 ENTER THE VALUTATION 1586 APPLICANT FIRE ALARM 60.75 ADT SECURITY SYSTEMS STATE SURCHARGE VAL OTHER 0.79 ' 5910 RICE CREEK PARKWAY#700 SHOREVIEW,MN 55126- MISC FEE 0.00 (763)792-6966 TOTAL 61.54 Minnesota State License#: TS0021 PAID WITH CC# 5919 OWNER WJM Properties,LLC LLC, WJM PROPERTIES, 12550 WAYZATA BLVD. MINNETONKA,MN 55305- AGREEMENT AND SWORN STATEMENT The work for which this permit is issued shall be performed according to the approved plans and specifications,applicable City approvals,and the State Building Code. This permit is for only the work described and does not grant permission for additional or related work which requires separate permits. All provisions of laws and ordinances governing this type of work shall be compied with whether or not specified herein.This permit will expire and become null and void if construction authorized is not commenced within 180 days of the date of issuance,or if construction is suspended for a period of 180 days at any time after work has commenced. The applicant is responsible for assuring all required inspections are requested in conformance with the State Building Code.This permit may be revoked at any time for due cause. Applicant Permitee Signature Date Issued By Signature Date SEPARATE PERMITS REQUIRED FOR WORK OTHER THAN DESCRIBED ABOVE. , CITY OF ORONO * 2 0 1 2 - 0 0 1 7 4 2750 KELLEY PARKWAY DATE ISSUED: 03/19/2012 ORONO, MN 55356- 952 249-4600 FAX: 952 249-4616 ADDRESS 2605 WAYZATA BLVD W PIN 33-118-23-13-0015 LEGAL DESC VAN DALE ADDN LOT 000 BLOCK 000 PERMIT TYPE FIRE SYSTEMS PROPERTY TYPE : COMMERCIAL-BUSINESS CONSTRUCTION TYPE : EXT HER Pj,-4mr� NOTE: INSPECTIONS ARE DONE BY FIRE MARSHALL,JAMES VAN EYLL. PLEASE CALL JAMES VAN EYLL DIRECTLY AT:(952)473-9701 TO SET UP AN INSPECTION. ADDITION TO FIRE EXTINQUISHER- ENTER CONTRACT PRICE 1586 ENTER THE VALUTATION 1586 APPLICANT FIRE ALARM 60.75 ADT SECURITY SYSTEMS STATE SURCHARGE VAL OTHER 0.79 5910 RICE CREEK PARKWAY#700 SHOREVIEW,MN 55126- MISC FEE 0.00 (763)792-6966 TOTAL 61.54 Minnesota State License#:TS0021 PAID WITH CC# 5919 OWNER WJM Properties,LLC LLC,WJM PROPERTIES, 12550 WAYZATA BLVD. MINNETONKA,MN 55305- AGREEMENT AND SWORN STATEMENT The work for which this permit is issued shall be performed according to the approved plans and specifications,applicable City approvals,and the State Building Code. This permit is for only the work described and does not grant permission for additional or related work which requires separate permits. All provisions of laws and ordinances governing this type of work shall be compied with whether or not specified herein.This permit will expire and become null and void if construction authorized is not commenced within 180 days of the date of issuance,or if construction is suspended for a period of 180 days at any time after work has commenced. The applicant is responsible for assuring all required inspections are requested in conformance with the State Building Code.This permit may be revoke any time for due cause. A ant Permitee Signature Date Issue y Signature Date SEPARATE PERMITS REQUIRED FOR WORK OTHER THAN DESCRIBED ABOVE. o'ID/a D d 7`f FIRE ALARM OR KITCHEN EXTINQUISHER PERMITS Please Check One: ❑ New Addition © Remodel ❑ Replace Job Site/Owner Information: Site Address: 2605 Wayzata Blvd W,Long Lake,MN 55356 Owner: WJM Properties LLC Mailing Address: 12550 Wayzata Blvd Minnetonka 55305 City: Zip: Home Phone: (952)473-6961 Alternate Phone: Contractor/Applicant Information: ADT Security Joe Robinson Contractor/App.: Contact Person: Address: 5910 Rice Creek Pkwy 700 State License #: TS00021 Shoreview 55126 07/31/12 City: Zip: Expiration Date: (763)792-6981 Phone: Alternate Phone: TYPES OF FIRE PERMITS ❑� Commercial—Fire Alarm ❑ Commercial—Fire Extinguisher Fire Systems Permit Fire Systems Permit *Con�tract)Price. $ ���� *Contract Price: $ ❑ Residential—Fire Alarm Fire Systems Permit *Contract Price: $ I herby apply for a Fire Alarm/Extinguisher Permit and I acknowledge that the information above is complete and accurate; that the work will be in conformance with the Ordinances and Codes required by Minnesota State Building Code(MUBC)or Minnesota State Fire Code(MUFC)shall be installed and maintained as per National Fire Protection Association (NFPA) 72 and 72E, 1996 edition, National Electrical Code and manufacturers requirements;that I understand this is not a permit and work is not to start without a permit; and that the ill be in accordance with the approved plan. App Date Reset Form s o 5 G"ql f F !; c; ov ,e CA � s C-30 f� 2 u H1k Ri P C-3 �• VCL N ? cor, -- NCL W CL C:2o w. a ft N < DF-52121:C•E V5 MMF.300(A) Series, MDF-300(A) @Rre-UTUALarms ( ) Addressable Monitor Modules by Honeywell Addressab— le Devices J General Four different monitor modules are available for Fire•Lite's intelligent control panels to suit a variety of applications.Moni- tor modules are used to supervise a circuit of dry-contact input devices,such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (MMF-302(A)). MMF-300(A)is a standard-sized module(typically mounts to a 4' [10.16 cm) square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. MMF-301(A)is a miniature monitor module a mere 1.3"(3.302 cm)H x 2.75"(6.985 cm)W x 0.5"(1.270 cm)D used to super- vise a Style B(Class B)circuit of dry-contact input devices.Its compact design allows the MMF-301(A) to be mounted in a single-gang box behind the device it monitors. $ MMF-302(A)is a standard-sized module used to monitor and supervise compatible two-wire,24 volt,smoke detectors on a Style D(Class A) or Style B(Class B)circuit. MDF-300(A)is a standard-sized dual monitor module used to MMF-300(A)(Type H) monitor and supervise two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at two may be wired as an NFPA Style B(Class B)or Style D(Class separate,consecutive addresses in intelligent,two-wire systems. A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor LiteSpeedTm is a communication protocol developed by (provided) terminates the Style B circuit. No resistor is Fire•Lite Engineering that greatly enhances the speed of com- required for supervision of the Style D circuit. munication between analog intelligent devices. Intelligent MMF-300(A) OPERATION devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU Each MMF-300(A) uses one of the available module stops the group poll and concentrates on single points. The addresses on an SLC loop. It responds to regular polls from net effect is response speed greater than five times that of the control panel and reports its type and the status(open/nor- other designs.designs. mal/short)of its Initiating Device Circuit(IDC).A flashing LED indicates that the module is in communication with the control MMF-300(A) Monitor Module panel. The LED latches steady on alarm (subject to current • Built-in type identification automatically identifies this device limitations on the loop). as a monitor module to the control panel. MMF-300(A) SPECIFICATIONS • Powered directly by two-wire SLC loop.No additional power Nominal operating voltage:15 to 32 VDC. required. Maximum current draw:5.0 mA(LED on). • High noise(EMF/RFI)immunity. Average operating current: 350 NA (LED flashing), 1 com- • SEMS screws with clamping plates for ease of wiring. munication every 5 seconds,47k EOL. • Direct-dial entry of address: 01 –159 on MS-9600 series Maximum IDC wiring resistance:40 ohms. panels,01–99 on other compatible systems. EOL resistance:47K ohms. • LED flashes during normal operation and latches on steady to Indicate alarm. Temperature range:32•F to 120°F(0°C to 49°C). The MMF-300(A)Monitor Module is intended for use in intelli- Humidity range:10%to 93%noncondensing. gent,two-wire systems,where the individual address of each Dimensions 4.5' (11.43 cm) high x 4' (10.16 cm) wide x module is selected using the built-in rotary switches. It pro vides either atwo-wire or four-wire fault-tolerant Initiatin1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x g 2 125'(5.398 cm)deep box. Device Circuit(IDC)for normaly-open-contact fire alarm and supervisory devices.The module has a panel-controlled LED indicator. The MMF-300(A)can be used to replace M300(A) modules in existing systems. MMF-300(A)APPUCATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterlow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit DF-52121:0.10/06/2010 Page 1 of 4 MMF-301(A) Mini,Monitor'Module Dimensions: 1.3'(3.302 cm)high x 2.75" (6.985 cm)wide x • Built-in type Identification automatically identifies this device0.65'(1.651 cm)deep. as a monitor module to the panel. Wire length:6'(15.24 cm)minimum. • Powered directly by two-wire SLC loop.No additional power required. MMF-302(A) Interface Module • High noise(EMF/RFI)Immunity. • Supports compatible two-wire smoke detectors. • Tinned,stripped leads for ease of wiring. • Supervises IDC wiring and connection of external power • Direct-dial entry of address:01 —159 on MS-9600 series source. panels,01—99 on other compatible systems • High noise(EMF/RFI)immunity. a • SEMS screws with clamping plates for ease of wiring. 1415 0 1 0 1 • Direct-dial entry of address: 01 —159 on MS-9600 series s S. . 2 2 panels,01 —99 on other compatible systems. - LED flashes during normal operation. 14 O 4 • LED latches steady to indicate alarm on command from 9 6 5 control panel. TENS ONES The MMF-302(A)Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors.It transmits the status(nor- 0 O _= U mal,open,or alarm)of one full zone of conventional detectors W ' Q back to the control panel. All two-wire detectors being moni- } " m tored must be UL compatible with the module. The MMF- 302(A) can be used to replace M302(A) modules in existing systems. MMF-302(A)APPLICATIONS Use the MMF-302(A) to monitor a zone of two-wire smoke The MMF-301(A) Mini Monitor Module can be installed in a detectors. The monitored circuit may be wired as an NFPA single-gang junction directly behind the monitored unit. Its Style B(Class B)or Style D(Class A)Initiating Device Circuit. small size and light weight allow it to be installed without rigid A 3.9 K ohm End-of-Line Resistor(provided) terminates the mounting. The MMF-301(A) is intended for use in intelligent, end of the Style B or D (class B or A)circuit(maximum IDC two-wire systems where the individual address of each module loop resistance is 25 ohms). Install ELR across terminals 8 is selected using rotary switches. It provides a two-wire initiat- and 9 for Style D application. ing device circuit for normally-open-contact fire alarm devices. The MMF-301(A)can be used to replace M301(A)modules in MMF-302(A)OPERATION existing systems. Each MMF-302(A) uses one of the available module MMF401(A)APPLICA TIONS addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status(open/nor- Use to monitor a single device or a zone of four-wire smoke mal/short)of its Initiating Device Circuit(IDC).A flashing LED detectors,manual fire alarm pull stations,waterflow devices,or indicates that the module is in communication with the control other normally-open dry-contact devices.May also be used to panel. The LED latches steady on alarm (subject to current monitor normally-open supervisory devices with special super- limitations on the loop). visory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B(Class B)Initiating Device Circuit. MMF-302(A)SPECIFICATIONS A 47K ohm End-of-Line Resistor(provided)terminates the cir- Nominal operating voltage:15 to 32 VDC. cuit. Maximum current draw:5.1 mA(LED on). MMF-301(A)OPERATION Maximum IDC wiring resistance:25 ohms. Each MMF-301(A) uses one of the available module Average operating current:300 IiA, 1 communication and 1 addresses on an SLC loop. It responds to regular polls from LED flash every 5 seconds,3.9k eol. the control panel and reports its type and the status(open/nor- mal/short)of its Initiating Device Circuit(IDC). EOL resistance:3.9K ohms. MMF-301(A) SPECIFICATIONS External supply voltage (between Terminals T3 and T4): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms Nominal operating voltage:15 to 32 VDC, maximum.Current:90 mA per module maximum. Average operating current:350 pA, 1 communication every Temperature range:320F to 120°F(0°C to 490C). 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Humidity range:10%to 93%noncondensing. Shorted). Maximum IDC wiring resistance:40 ohms. Dimensions: 4.5' (11.43 cm) high x 4" (10.16 cm) wide x 125" (3.175 cm)deep. Mounts to a 4" (10.16 cm)square x Maximum IDC Voltage:11 Volts. 2.125"(5.398 cm)deep box. Maximum IDC Current:400 pA. EOL resistance:47K ohms. Temperature range:32•F to 120•F(0•C to 49•C). Humidity range:10%to 93%noncondensing. Page 2 of 4—DF-W121:C•10/06/2010 MDF-300(A) Dual Monitor:Module Product Line Information The MDF-300(A) Dual Monitor Module is intended for use in NOTE:'A'suffix indicates ULC-listed model. Intelligent, two-wire systems. It provides two independent two MMF-300(A):Monitor module. wire initiating device circuits(IDCs)at two separate,consecutive addresses.It Is capable of monitoring normally open contact fire MMF-301(A):Monitor module,miniature. alarm and supervisory devices.The module has a single panel- MMF-302(A):Monitor module,two-wire detectors. controlled LED. NOTE:The MDF-300(A)provides fm Style 8(Class 8)IDC cir- MDF-300(A): Monitor module,dual,two independent Class B cults ONLY. Style D(Class A)IDC circuits are NOT supported in circuits. any appfication• SM0500:Optional surface-mount backbox. MDF-300(A)SPECIFICATIONS NOTE:See installation instructions and refer to the SLC Wiring Normal operating voltage range:15 to 32 VDC. Manual,PN 51309. Maximum current draw:6.4 mA(LED on). Architects'/Engineers' Specifications Average operating current:750 pA(LED flashing). Specifications of these devices and all FireLlte products are Maximum IDC wiring resistance:1,500 ohms. available from Firel-ite. Maximum IDC Voltage:11 Volts. Maximum IDC Current:240 pA EOL resistance:47K ohms. Maximum SLC Wiring resistance:40 Ohms. Temperature range:320 to 120°F(00 to 4WC). Humidity range:10%to 93%(non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 2.125"(5.398 cm)deep. MDF-300(A) AUTOMATIC ADDRESSING The MDF-300(A)automatically assigns itself to two address- able points,starting with the original address. For example, if the MDF-300(A) is set to address "26", then it will automati- cally assign itself to addresses"26"and"2T'. NOTE:"Ones"addresses on the MDF-300(A)are 0,2,4, 6, or 8 only. Terminals 6 and 7 use the first address,and terminals 8 and 9 use the second address. QCAUTION: Avoid duplicating addresses on the system. Installation MMF-300(A), MMF-302(A), and MDF-300(A) modules mount directly to a standard 4"(10.16 cm)square,2.125"(5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and Installa- tion instructions are provided with each module. All wiring must conform to applicable local codes,ordinances,and regu- lations. These modules are intended for power-limited wiring only. The MMF-301(A)module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes,ordinances,and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies,or listing may be in process. Consult fac- tory for latest listing status. • UL:S2424 • ULC:S2424 • FM Approved • CSFM:7300-0075:0185 • MEA:72-01-E DF-52121:C•10/06/2010—Page 3 of 4 t co Fire & ADT Security 472368 SIM GATEWAY For accomodating up to 72 SIM input/output points. Consists of a tampered circuit board that is housed in a separately ordered 471943 Housing Unit(same as Micro PID).Gateway comes with two terminal strips: one for connection to the RS-485 bus and one for connecting the gateway trunk,both of which use the 494465( B6465)Cable. AI=SI=50ma SIZE: 2 1/2" L X 2 3/4" W X 1 1/4" H SIM Gateway Physical Description: Item Purpose Terminal Strip TBI Makes connections to the RS-485 bus. Terminal Strip T132 Makes connections to the Gateway Trunk. RS-485 Address Dip Switches Establishes the Gateway address on the RS-485 bus. Tamper Switch Triggers a trouble when activated by removal of the cover. Receive LED(RED and Indicates the gateway communication status as follows: Transmit LED(YELLOW • Receive Red LED flashes when the gateway is receiving • Transmit Yellow LED flashes when the gateway is transmitting E1 Jumper Terminates the RS-485. TAMPER SWITCH OPERATOR ♦Q N ®- TAMPER SWITCH m 0 A TW Q� GATEWAY TRUNK j d G TEPA0 AL STRP GATEWAY NcROpRocessm _ _ TEPAWALSTM 751 CONNECTIONS TO RSJ66 SUS IfOLK)GdD 0 TRANSMIT LED(YEL) 0 2(RM)+12V Et JUMPER El 3(ya)COM• E AA4PEA RS-/06 Sys ADDRESSa 1( )COM* TO DISCONNECT RS-4W DIP SW ITCHES O T"LWATM RESISTOR] co D, 04 ON City of Orono FOR CITY USE ONLY P.O.Box 66 Date Received: 317/ Permit#Q7D ' 2750 Kelley Parkway C VCrystal Bay,MN 55323 Amount: $ /5 �1, (952)249-4600 'L Approved Bya Charge Plan Review Recommends: A oval / Denial ❑ C001- CITY OF ORONO—FIRE ALARM OR KITCHEN EXTINGUISHER/GENERAL PERMIT (All permits must be approved by the Fire Marshall and/or Building Official) 1. All fire alarm systems,voluntary or required by Minnesota State Building Code(MUBC)or Minnesota State Fire Code(MUFC)shall be installed and maintained as per National Fire Protection Association(NFPA)72 and 72E, 1996 edition,National Electrical Code and manufacturers requirements. 2. Permits are required for all fire alarm system installations. Permits can be obtained from the City of Orono-Building Official at,2750 Kelly Parkway Orono,MN or via phone(952)249-4600. Permits are also available online at: www.ci.orono.mn.us 3. Two sets of plans and specification sheets shall be submitted to the Orono Fire Marshal for approval at least 7 workiniz days before start of installation and shall include: a. Specification data sheets on all components of system. b. Floor plans indicating locations of devices,fire alarm control panel,sub-panels,transponders, enunciator,interconnecting wiring and zoning. c. Power connections including source and branch circuit data. d. Type of back up power system. e. Fire alarm control panel shall be compatible with all devices. f. All components of the system shall be UL or FM listed for their applications. Smoke detectors shall be listed for commercial/industrial use. 4. All systems shall be addressable. Smoke detectors shall be photo-electric.No combination burglar/fire alarm systems are allowed unless approved by the Orono Fire Marshal. 5. Power supply for the system shall include battery back-up with a UL listed fire alarm panel. Alarm verification is required for all systems using smoke detectors. 6. The alarm system shall be audible above the ambient noise level in all areas of the building. Audio/visual signaling devices are required. 7. When central station notification is required or provided it must be through a UL or FM listed communicator or control panel. 8. If a smoke detecting system installed in the tenant space of a building is directly connected to the building fire alarm panel,then a. A zone on the alarm panel must identify the tenant space or zone of the building that the system is located(i.e.,second floor,west wing). b. A visual annunciation light shall be installed on the corridor side of the main door of the tenants space and activate when the detection system in the tenants space activates. 9. The system shall be tested in the presence of the Orono Fire Marshal for final approval. Appointments can be made by calling the Fire Marshall at(952)473-9701, 24-hours notice is requested. The test will include: a. Random testing of system devices. b. Random testing for system trouble and ground fault trouble. c. Correct operation of back-up power system.