HomeMy WebLinkAboutFire System Inspection & Maint Report Kitchen Hood Fire System Inspection & Maintenance Report DATE OF SERVICE TIME A.M. RM. o,-pENDAR1F t7 F ! mac° N 0 RTFI LAN D ANNUAL SEMI-ANNUAL RECHARGE INSTALLATION RENOVATION NQS ;¢, Yy FIRE & SECURITY LOCATION OF SYSTEM CYLINDERS 990 Lone Oak Road, Suite 114 Eagan, MN 55121 MANUFACTURER MODEL NUMBER WET CHEMICAL` DRY CHEMICAL Phone: (651) 287-8555 -', ; ,_-,,...- X Fax: (651) 287-8540 CYLINDER SIZE MASTER CYLINDER SIZE SLAVE CYLINDER SIZE SLAVE www.nfs-mn.com ':'( 11 t t,1,. „„ MANIFOLDERJ1 PIRANHA WATERFLOW PRESSURE - ❑YES ❑ NO Name FUSE LINKS 360°F FUSE LINKS 450°F FUSE LINKS 500°F OTHER • Address ; - -4 - i . . •�tF' --:: Th MECHANICAL GAS VALVE(S)&SIZE(S) ELECT.GAS VALVE(S)&SIZE(S) MANUAL RESET RELAY City /t i, i ) i' ;1 3 '+ : 1 r ❑ YES ❑ NO SERIAL NUMBER LAST HYDRO TEST DATE LAST RECHARGE DATE Telephone , >� - • - i., 5 Store No. OWrter or`IVlehager MANUFACTURER'S MANUAL REFERENCE NOTE:NON COMPLIANT SYSTEMS MAY FAIL TO EXTINGUISH/SUPPRESS A FIRE. COOKING APPLIANCE LOCATIONS&SIZES:LEFT TO RIGHT YES NO N/A YES NO N/A 1. System interlocked with building fire alarm -2`❑ ❑ 20. Proper separation between fryers&flame /12' ❑ El 2. Duct and plenum covered with correct nozzles p r❑ El 21. Proper clearance-flame to filters ❑ ❑ 3. Check positioning of all nozzles -f2'"❑ ❑ 22:Exhaust fan in operating order ? ❑ ❑ 4. System installed per U.L. 300 standard& meets 23. All filters replaced El ❑ manufacturers U.L. listing & N.F.P.A. standards ,Z.-❑ ❑ 24. Fuel shut-off in on position /" ❑ ❑ 5. Hood/duct penetrations sealed with weld or UL device ,Z-❑ ❑ 25. Manual & remote set/seals in place ', E ❑ 6. Check if seals intact, evidence of tampering ❑„21' ❑ 26. Replace system covers r,,J2.❑ ❑ 7. Pressure gauge in proper range (if gauged) ❑ ❑ 27. System operational &seals in place ❑ 8. Check cartridge weight(if applicable) . '❑ ❑ 28. Slave system operational 'LI,,,C7"" 9. Dry system 6 year maintenance date/wet system 29. Clean cylinder& mount "❑ El 12 year hydro-test date d ❑ ❑ 30. Fan warning sign on hood ,e1 El ❑ 10. Inspect cylinder and mount pet El El 31. Proper signage and personnel instructed in 11. Operate system from terminal link .LJ ❑ CI _ manual operation of system , ''❑ CI12.Test for proper operation from remote ,Pr❑ ❑ .4Proper hand portable extinguishers , f` ❑ ❑ 13. Check operation of micro switch „IZ❑ ❑ '33T1K class fire extinguisher in cooking area ❑..11-- 14. Check operation of gas valve ,,0 ❑ ❑ 34. Portable extinguishers properly serviced ,''❑ ❑ 15. Clean nozzles X ❑ ❑ 35. Service&Certification tag on system ,f '❑ ❑ 16. Proper nozzle covers in place X CI 11136. Safety chains on all gas appliances attached and secured '❑ CI17. Replaced fuse links ❑ ❑ 37. Status of grease buildup in the hood and duct opening 18.Check travel of cable J❑ ❑ V Clean ❑ Light ❑ Medium ❑ Heavy ❑ Excessive 19. Piping &conduit securely bracketed 2(❑ ❑ * NOTE DISCREPANCIES OR DEFICIENCIES BELOW* COMMENTS: I--, - ,` On this date, the above system was tested and inspected in accordance with procedures of the presently adopted editions of NFPA 17„:17A,,,.96 apd the manufacturer's manual and was operated according to these procedures with results indicated above. X , "1' (--..,_ i,`/: -)a S1 pt TECHNICIAN PERMIT NO. DATE: TIME: AM PM CUSTOMERS AUTHORIZED AGENT The bo'ie service technician certifies that the system was personally inspected and found conditions to be as indicated on this report. WHITE-CUSTOMER • YELLOW- DISTRIBUTOR • PINK-AUTHORITY HAVING JURISDICTION