Loading...
HomeMy WebLinkAboutGrease Interceptor Replacement 0 H A '" 225 Bridgepolnt Drive CSouth St. Paul, MN 55075 MECHANICALS Ph651-292-9933 : 651-292-9929 Proposal Date •1 Date Cif See Visit Proposal Number 11/26/2013 I 11/8/2013 S13820 SUBMITTED TO: PROJECT NAME AND LOCATION: Wayzata Country Club Grease Interceptor Replacement 200 Wayzata Blvd West Wayzata,Minnesota 55391-1557 PHONE: (612)741-6280 ATTENTION: Rich Crosson rcrosstowniffivahoo.com CONTRACTOR WILL PROVIDE THE FOLLOWING Base Bid Furnish labor and materials to replace the existing grease interceptor with a larger capacity Interceptor including concrete cut, removal&disposal of old interceptor, setting of new interceptor,flow fitting, waste piping,vent piping,and concrete repair. TOTAL Alternate Furnish labor and materials to connect waste from rinse bowl to grease waste main including pipe&fittings. Note: Garbage disposal must be removed from service. TOTAL Note; Work to be schedule during club shutdown in February Exclusions: Premium Time Work Beyond Proposal Hazardous Material Exposure Please contact me at(651)292-9933 with any questions or concerns All material is guaranteed to be es speeded All work shall be 4omplet01 IA a wodorionhke•mater aocoeling to staciderdi praoiss Any aitersbo i ti'i deviation twin above speccrt:ettens invoking eadra costs wit become en era cheryw over end above the catenate ' to i o'4cn PPRR®F f 1,UT O '.€S 3C41 ANEW Mb 461a1CAL tt Pe'RFC-1RM T1i5.J 15+:+TICK AND MEPEBf ACCSPIlitniq TFRME:•NC'co -'TiON rT rrr i4l TJ T t f RCPv5•.L 0% down payment Is due with signed order. FINAL PAYMENT to be made as invoiced terms net 10 days. CONTRACTOR; Schadegg Mechanical CUSTOMER: Wayzata Country Club -. Signature: John L. Noe LEEDAP, Service Manager Name: Date: Note:This proposal may be withdrawn if not accepted within 45 days. SPECIFICATIONS(GB-75) 46' 1. 4"inlet/outlets Sch.40.(No-Hub) Outlet"A" 2- Max flow rate;75 GPM O Adjustable 3. Liquid capacity:125 Gallons (Optional)l) adapter 4. Max grease cap8d :616 lbs.(86 Gallons) s.' 1 5. Max seiids/sedtd.c gpackylbs. Gallons A 11P -01li� A /sR�R 6. Link weight wVstd.covers:130 lbs. t Di .. ..I�►•a �__ -� 'J 7. 16,000 lb.load rated,bolted,gas/water tight A .�•, ` 1 qi 8. um operating temperature 190"F continuous. Outlet"B" /1110, iu . ,,ir w (Standard) 11 NOTES • i" 1. Listed by IAPMO to ASME grease Interceptor 's —� t� i standardry #A112.14.3uil and CSA B4control. a( 2 �._, �. li 2. Factory installed euik�n flow mntrd. �I' I 3. For gravity drainage applications only. Do not use for pressure applications. 4. 3/8"thick seamless high density polyethylene walls. `., �,— J 5. Unit supplied with built-in adapter for up to 8"of +��� sus;4 adjustabfll .Additional risers)available for deeper �,l•l�•/Yl.i�..a.!►� _liktufg 1111_11 Deep structural burial depth. Outlet"C" Tie-down point reinforcing columns 6. Cover placement allows full access to tank (Optional) ---12" for anchor kit foroq maintenance_ 7. Ventproper not unless per local code. ISOMETRIC VIEW 8. Narrow footprint allows clearance through doorways TOP VIEW and down sfairwels. 9. Engineered inlet and outlet diffusers are removable to inspect/clean piping 10. For on-the-floor or buried applications. 024-1/2" - 32" 11. Integral Air Relief/Anti-siphon. 12. Three outlet options for easy rough in. Unit shipped with outlet diffuser in outlet"B". CE of inlet and outlet DIFFUSION FLOW TECHNOLOGY 1 he inlet diffuser splits incoming effluent into two paths that utilize the entire liquid volume of the tank for efficient I[i!t See note#11 grease separation. The calibrated openings greatlyreduce effluent turbulence. The effluent enters the main chamber _ __without disturbing the existing grease or sediment layers. 12-1/2" I\ rI, _The integral air relief/anti-siphon In the top of the outlet diffuser II.allows pressure stabilization within the unit during operation- \ i tThe bottom of the outlet diffuser allows only effluent which is free ofgrease to exit the tank. lili of the three outlets provideddtto ease Jobsite be pi ip ng llayoouts.ny 38 1C2" ENGINEER SPECIFICATION GUiDE 261 23-3/4"Schier Great Basin"'grease Inter eptor model#GB-75 stealInvertbe liife Ime guaranteed and made In USA of seamless,rotationaly- molded High Density Poyethylene with minimum 1/2'uniform wal thickness.Interceptor shall be furnished for above or below grade Installation.interceptor shall be built in accordance to ASME A112.14.3(type C),with field adjustable riser system,built-In lbw control,built-in test 111111 and three outlet options.Interceptor flow rate shall be 75 GPM. Interceptor grease capacity shall be 616 lbs.Cover shall provide Engineered inlet and water/gas-tight seal and have minimum 16,000 lbs load capacity. outlet diffuser (see description) OPTIONS: SECTION"A-A" END VIEW •a ide field adjustable risers for extending covers to grade • 6" le pipe thpipe connections O • 6"Plain end pipe connections(No-Hub) • High water anchor kit(set of 2) •• H2O rat d pitiable cast iron cover PART NUMBER:GB-75 ®kit SPECIFICATION S H EET cif DESCRIPTION: 0 0 0 O S00W Products 9809WoodeKS ' SCHIER ....• .. GREAT BASIN SERIES POLYETHYLENE Edwarckvllie,KS 66111 •++ rte- GREASE INTERCEPTOR 75 GPM, 125 LIQUID Tel:BOO.827-7119 -� ""` ""' raw N.. win. ' GALLONS, 616 GREASE POUNDS CAPACITY Fax:800-827-9664 www.schierproducts.com 3-) PRODUCTS PROPRIETARY weCONFIDENTIALi. Pioneering Droin Line Purity nrt INFORMATION aDirrN.10 Nn4WNW.■TNEWLE F"°FSTIOFE"1_RFN""""T"."NY Made In the U.S.A """"°" b1""°""'"""°''"" Ivo" gInmis'e"°r"."'"°"1 " DWG BY:TEU DATE: 1(14108 REV:5-513113 IMATL:PE