Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Fire Alarm/kitchen etinguisher general permit
V -. ,p,� City of Orono n IIiiIii 1., . •` s fl,\ P.O.Box 66 AA -4,,,- 'or C5523" CITY OF ORONO—FIRE ALARM OR KITCHEN EXTINGUISHER/GENERAL PERMIT (All permits must be approved by the Fire i41arshalt and/or Building Official) 1. All fire alarm systems,voluntary or required by Minnesota State Building Code(MUBC)or Minnesota State Fire Code(MUFC)shall be installed and maintained as per National Fire Protection Association(NFPA)72 and 72E, 1996 edition,National Electrical Code and manufacturers requirements. 2. Permits are required for all fire alarm system installations. Permits can be obtained from the Orono Fire Marshal(952)473-0234 or Orono Building Official at,2750 Kelly Parkway Orono,MN, I phone(952)249-4600. Permits are also available online at: www.ci.orono.mn.us 3. Two sets of plans and specification sheets shall be submitted to the Orono Fire Marshal for approval at least 7 working days bethre start of installation and shall include: a. Specification data sheets on all components of system. b. Floor plans indicating locations of devices,fire alarm control panel,sub-panels,transponders, enunciator,interconnecting wiring and zoning. c. Power connections including source and branch circuit data. d. Type of back up power system. e. Fire alarm control panel shall be compatible with all devices. f. All components of the system shall be UL or FM listed for their applications. Smoke detectors shall be listed for commercial/industrial use. 4. All systems shall be addressable. Smoke detectors shall be photo-electric.No combination burglar/fire alarm systems are allowed unless approved by the Orono Fire Marshal. 5. Power supply for the system shall include battery back-up with a UL listed fire alarm panel. Alarm verification is required for all systems using smoke detectors. 6. The alarm system shall be audible above the ambient noise level in all areas of the building. Audio/visual signaling devices are required. 7. When central station notification is required or provided it must be through a UL or FM listed communicator or control panel. 8. If a smoke detecting system installed in the tenant space of a building is directly connected to the building fire alarm panel,then a. A zone on the alarm panel must identify the tenant space or zone of the building that the system is located(i.e., second floor,west wing). b. A visual annunciation light shall be installed on the corridor side of the main door of the tenants space and activate when the detection system in the tenants space activates. 9. The system shall be tested in the presence of the Orono Fire Marshal for final approval. The test will include: a. Random testing of system devices. b. Random testing for system trouble and ground fault trouble. c. Correct operation of back-up power system. 6/1/2004 c. ySSqqp$a .7.,„' yy !!.�..4.,'„,...;:.:tm ��,+ v4, ,sem 41,, r d+t,' c,,-.414),,,„r i &,wt -z�p K- 1..T`:h � ge S s°5 F,,L, w.'..41d§�v S hSk,< i ''' ., 4 T ❑ New ❑ Addition Xi Remodel ❑ Replace Site Address: Z Co C..J (.....)/I laid jJ(.tJ9 Owner: L..Ji4Y14'i 1 e&h.;1Z/ eL.-%a•S Mailing Address: Zoe U. (--iPim T1 iLLU© City: OZQL9 L Zip: S-7 -.X i Home Phone: Alternate Phone: _A_ ag- ' <t .1,.'61',I;,-:::11,1„,q1'911‘1 7 '"'fi r, Contractor/App.: c,Mkex 6R a 6seJ4. ti Contact Person: /lit/lax- Oa isrE Address: S` fieri f,44) cx-% State License#: City: 9f,))0iovrr/ Zip: MO Expiration Date: Phone: 763'"36) Ste' Alternate Phone: ` s. ,'�... -��.m, ..,,�;�'�.d 1,. ot..,. ...6,.�w.w�,dtz l '�,� 4 .,.,a .4,,i e,.. ...... y .,..,.... .=..M.< a. ,t:..x .z. ..,... `.r7k,';;a ❑ Commercial—Fire Alarm V Commercial—Fire Extinguisher Fire Systems Permit Fire Systems Permit *G 1.p * 1;: II *Contract Price:$ *Contract Price:$ 'L/ ..V ),c ❑ Residential—Fire Alarm FireS stems Permit *ai c,6,1;'-.) *Contract Price:$ F:-s*.," a9 '4..77:011Mt l a.i ,Iu_ R Cirt i aaa a a i? a s l.i -.@; ail.i t .: 'n":•. .. ®I I herby apply for a Fire Alarm/Extinguisher Permit and I acknowledge that the information above is complete and accurate;that the work will be in conformance with the Ordinances and Codes required by Minnesota State Building Code(MUBC)or Minnesota State Fire Code(MUFC)shall be installed and maintained as per National Fire Protection Association (NFPA) 72 and 72E, 1996 edition, National Electrical Code and manufac ers requirements;that I understand this is not a permit and work is not to start without a permit; and '.t the .. ac : d. e with the approved plan. Applicant Date € d,. ' r{ " ¢ , r ',,, �/ ,W 6c,Q'c4 ✓ /y /0 l ...,e_ i a Conf. i rmat i on Report — Memory Send Time : Nov-02-2004 10:55am Tel line : +9522494616 Name : CITY OF ORONO Job number 878 Date Nov-02 10:53am To 6123402644 Document pages 008 Start time Nov-02 10:53am End time Nov-02 10:55am Pages sent 008 Status : OK Job number : 878 *** SEND SUCCESSFUL *** o p o City of Oy-o n o 2750 Kelley Parkwcry O. Box 66 Crystall1ay, MN 55323 (932) 249-4600 Fax: (952) 249-4616 FAS£TRILNSMISSION COVER SI-Tr-.ET bate: 49 . o!' : A1.1 i J4 ._ �L.(�6roi-it 5 `�o�aT•o' 4 �JIJf �••� _....... xe: I.4• use-4::av�ivav YOU SHO ULD RECEIVE PAGE(.S), INCLUDING THIS CC)VER SHEET. IF YOU DO NOT RECEIVE_ALL THE PAGES PLEASE CALL (952) 249-4600. -r14-04-9" t.,1/41/45 ,e9N /D /v t c . . . ;i ° o� City ofOrono 9x'�sxoS` 2750 Kelley Parkway P.O. Box 66 Crystal Bay, MN 55323 (952) 249-4600 Fax: (952) 249-4616 FAX TRANSMISSION COVER SHEET Date: // Z'Q� To: AOP,2AUV/LL/a4^6M S `�O�56�'"1 `� Wk 1T Fax: 44z 390 - 240 Re: LAM Y 2111A CC W111IGoikNv1 G j VSA` vcie tt.ypith Sender: /i41kf' YOU SHOULD RECEIVE $ PAGE(S), INCLUDING THIS COVER SHEET. IF YOU DO NOT RECEIVE ALL THE PAGES, PLEASE CALL (952) 249-4600. AK/NG Fak.m SAT vlik5 M414-&b PN /P-2.5 -o fou , ,