HomeMy WebLinkAbout2009-00042 - sprinkler system CITY OF ORONO PERMIT NO.: 2009-00042
2750 KELLEY PARKWAY
ORONO,MN 55356- DATE ISSUED: 03/03/2009
(952) 249-4600 FAX: (952)249-4616
ADDRESS : 200 WAYZATA BLVD W
PIN : 36-118-23-43-0001
LEGAL DESC : UNPLATTED 36 118 23
: LOT 000 BLOCK 000
PERMIT TYPE : FIRE SYSTEMS
PROPERTY TYPE : COMMERCIAL-BUSINESS
CONSTRUCTION TYPE : SPRINKLER SYSTEM
NOTE: INSPECTIONS ARE DONE BY FIRE MARSHALL,JAMES VAN EYLL.
PLEASE CALL JAMES VAN EYLL DIRECTLY AT:(952)473-9701 TO SET UP AN INSPECTION.
ENTER THE VALUTATION 11900
APPLICANT FIRE SPRINKLER-COMMERCIAL 148.75
SUMMIT FIRE PROTECTION STATE SURCHARGE VAL OTHER 5.95
575 MINNEHAHA AVE. W.
ST. PAUL,MN 55103- MISC FEE 1.50
(651)251-1880 TOTAL 156.20
Minnesota State License#: C-075
OWNER
CLUB,WAYZATA COUNTRY
200 WAYZATA BLVD W
,MN 55391-
AGREEMENT AND SWORN STATEMENT
The work for which this permit is issued shall be performed according to
the approved plans and specifications,applicable City approvals,and the
State Building Code. This permit is for only the work described and does
not grant permission for additional or related work which requires separate
permits. All provisions of laws and ordinances governing this type of work
shall be compied with whether or not specified herein.This permit will
expire and become null and void if construction authorized is not
commenced within 180 days of the date of issuance,or if construction is
suspended for a period of 180 days at any time after work has commenced.
The applicant is responsible for assuring all required inspections are
requested in conformance with the State Building Code.This permit may be
revoked at any time for due cause.
Applic ermitee Signature Date Issu By Signature Date
SEPARATE PERMITS REQUIRED FOR WORK OTHER THAN DESCRIBED ABOVE.
inatAi /303A coq- eao4/0Z.;
❑ New 1541 Addition ❑ Remodel n Replace
Site Address: 0OO WeST t,da yq,,ciTck Qtua
Owner: Wc%yZQkA CoyAtr/ cLo Mailing Address: A0 LJ. (oaf*Ara 13(vc,
City: k•f4,,A'1' Zip: 55 39 1
Home Phone: 15 a-I-113 -11.4644, Alternate Phone:
Contractor/App.: Sim hn tT Fife Contact Person: Sco1T'5e,Ad f
Address: 511 144eha ktc Ave 1)• State License#: C O 11—
City:
City: StPA:44 A Zip: 55103 Expiration Date: 0./71 /c,'
Phone: CV- aC i-i 8430 Alternate Phone:
5(1 Commercial—Fire Sprinkler ❑ Residential—Fire Sprinkler
Fire Systems Permit p Fire Systems Permitit
*Base Price=Contract Price:$ (J� `00 x.0125 =$ 141.0).45--
'7 Tc),"��j
(Minimum$35.00)
*Surcharge=Contract Price:$ 11,q OO x.0005 =$ CIS (Minimum $ .50)
*Mail-In Fee(Only On Mail In Applications) =$ 1.50
*Total Cost of Permit: =$ 1 5p.ao
The undersigned herby applies to the City for issuance of a Sprinkler Systems Permit. Applicant agrees
that all systems shall be designed, installed and maintained to N.F.P.A.-13,N.F.P.A.-25, Minnesota State
Building Code, Minnesota State Fire Code and Standards,and certifies that all statements made on this
application are complete,true and correct.
1oi
Applicant Date
l/ottogy J/1 t VAN Cyl/ 3.2.0.1 OP-C)
RECEIVE®
40/1; FEB 0 4
2000
• SUMMIT c"yoFORONo
FIRE PROTECTION
LETTER OF TRANSMITTAL
Date: 02/03/09 Send Via: Mail
To: CITY OF ORONO UPS
2750 KELLEY PKWY Delivery
ORONO, MN 55356 1-hour •
Attn: FIRE MARSHAL Enclosed is (are): Shop Drawings
Close-Out Documents
Job # 128519 Product Submittals
Change Order Letter
Job: WAYZATA COUNTRY CLUB Request for Proposal
Payment Application
Other
Copies Date Description
3 1/5/2009 FIRE PROTECTION PLANS
3 1/5/2009 PRODUCT SUBMITTAL
1 1/29/2009 PERMIT APPLICATION
1 1/30/2009 CHECK FOR PERMIT
These are Transmitted:
For Approval Returned after use
=As Requested Rejected
For your Information Revise and Resubmit
=Approved as submitted For Review
-Approved as Noted For Your Use •
For Bids Due:
Remarks:
Signed: SCOTT SEGNER
575 MINNEHAHA AVE.W. 3020 40TH AVENUE NW 418 GREAT OAK DRIVE
ST.PAUL,MN 55103 ROCHESTER,MN 55901 ST.CLOD,MN 56387
PHONE(651)251-1880 PHONE(507)280-0622 PHONE(320)257-6390
FAX(651)251-1879 FAX(507)280-0577 FAX(320)257-6392
Bulletin 157 Rev.F
R Model F3QR ; 04 .:, . 03
,-
Reliable
Quick Response 5
Dry Sprinklers i
Features �'
1 . The Model F3QR sprinkler utilizes Belleville Spring
Closure Technologvi Reliable is the first in the - ' ' •,1
inaustr; to produce C., Quid; Response Dr
.
Concealed sprinkler utilizing this technology. . t , .
Concealed • ,;.
2. Styles available .
. ..
•
•
• Pendent .�•
• Recessed Pendent - A,t
• Concealed F - 4 ,,
• Horizontal Sidewall '_ : •' . ',,
• Recessed Horizontal Sidewall .. i- .> .. •;.4
11/2' (38mm) escutcheon adjustment•on pendent Concealed
sprinkler.
4. 1/2' (13mm) escutcheon adjustment on recessed
sprinkler with push-on/ thread-off FP Model
Escutcheon ring. —
5. /" (9.5mm) cover plate adjustment on concealed
sprinkler with push-on/thread-off CCP Cover Plate. `
6. Attractive appearance. Employs 3mm frangible •
glass bulb and galvanized nipple.
7. Lengths available to accommodate installation
dimensions from 2"-to-48"(51 mm-to- 1219mm),
in 1/4" (6mm) increments. Recessed Pendent
8. Available in a variety of plated and painted finishes.
U.S. Patent Numbers 5,775;431 and 5,967,240.
Approvals ;
1. Listed by Underwriters Laboratories Inc. and
UL Certified for Canada (cULus)
, Sprinkler
Style i Response System em Type Hazard
I Pendent ,-1....i
;Recessed Pendent
;CCP Concealed Wet Pipe
(R5714) Quick Dry Pipe Light Pendent
Ordinary
Horizontal Sidewall All Preaction
Recessed Horizontal Sidewall "1 .
(R5734) g Ik
2. Certified by FM Approvals
Style Response Sprinkler Hazard 1.'1',. ;am' ,r''
System Type ,.., ,
Light 4.. ,,„
Wet Pipe:
Pendent Ordinary,
l(R5714) Quick Single
Interlock Groups
Preaction 1&2
Horizontal Sidewall Wet Pipe,
(R5734) Quick Single Interlock Light
Preaction
3. NYC MEA 258-93-E Horizontal Sidewall
The Reliable Automatic Sprinkler Co.,Inc., 525 North MacQuesten Parkway,Mount Vernon,New York 10552
` Model F3QR Dry Pendent Sprinkler
"A"Dim. 2'to 48'(51 mm to 1219mm)in 1/4"(6mmJ increments
Finishes"' Inlet Protrusion Elevated
Above Inside Pipe
Sprinkler Escutcheon - ____ ____ --
I Bronze • Brass c --i----1-4--4,--r _
Chrome Plated • Chrome Plated •
White Painted`z' White -"m RA �
r == ti
Other finishes and colors are available on special order system Tee
•
Consult factor,' or details. —
h .
''White painted sprinklers will have chrome plated cans. 2 1/8" D . I "PT
.Dmm]
"A" Dimension ..f.54,;?Zing
Ceiling
Adjustment Range
Standard Temperature Ratings +1/4"[4.6.4mm] 1 43/64-D10-
.._.._...__-_ I - [-31.8mm] [42.5mm] I I 1 1/2" [38.1mjostmem)
fSprinkler Bulb / I Sprinkler Con r. °t°I Adjustment
Temperature Max. i r Ce 10-° FI—T1 1/4."[31.8mm]
_Classification Rating Ambient Temp. 1 Color I i .•;;; ;----- "1/4" [mean]
Escutcheon ----- I Escutcheon
0 0 0 ° Ceding' -C ng 1 Adjustment
Ordinary 135°F (57°C) 100°F (38°C) IOrange I 1
Ordinary 155°F (68°C) 100°F (38°C) Red t • i --- i-T" t
Intermediate 200°F (93°C) 150°F (66°C) !Green `
High 286°F (141°C) 225°F (107°C) I Blue Nominol Position (114111 [q,3mm]
• of Escutcheon `„�
•
1/4" ,]
Classi •fication R3"Dia.
• "".—[76.2mm] 157FG0/-C
Sprinkler Guard: Model C-2
- Sprinkler•Installation Wrench Note: The sprinkler Can protrudes 1/4"when escutcheon is
Model G3 Sprinkler Wrench in nominal position. Escutcheon adjustment pro-
Sprinkler Identification Number (SIN): R5714 vides+1/4''(+6mm)to -11/4"(-32mm) "A"dimension
adjustment range.
Model F3QR Dry Recessed Pendent. Sprinkler
. ,"A"Dim. 31/2'to 48"(89mm to 1219mm)in 1/4"(6mm) increments }}
Inlet Protrusion Elevated C__-_ r T----r--11iPIG___.:,
Finishes") " Above Inside Pipeil{<I L,
Sprinkler 1 Escutcheon A=4--,- i_-- ;lj-- j
I ,.s-7, r-i 4
Bronze Brass r __ [,
Chrome Plated • Chrome Plated I ,- _ , " System Tee
White Painted White
''Other finishes and colors are available on special order. Consult • 2 1/2" Dio. -- 1." NPT
factory for details.Cup remains unfinished.Only the escutcheon [63.50mm]
will contain desired finish. "A" Dimension Hole in Ceiling
Adjustment Range
±1/4" 2 19/64.'• Dia.
Standard Temperature Ratings [±6.35mm] [58.34mm]
Sprinkler j.
II
Temperature I Max. I Bulb - Nominal Position Sprinkler
Classification Rating i Ambient Temp. Color of Escutcheon Cup Assembly
Ordinary 135°F (57°C) 1100°F (38°C) Orange __
— �- r �Escuichecn
Ordinary 155°F (68°C) 100°F (38°C) Red I } 4 + ;�Ceiling I oil-
Intermediate 200°F (93°C) :150°F (66°C) Green ' 1 1 Il I1'" Ceiling
High" 286°F (141°C) 225°F (107°C) Blue(
Escutcheon Adjustment
1/4" [5.35mm] 3 7/32" Dio.
"Listed and Certified only by cULus Escutcheon Adjustment [81.76mm]
1/2" [12.7mm] —
Total Adjustment 1572-002-C
Sprinkler Installation Wrench
Model G3 R/C Sprinkler Wrench Note: Do not install the Model F3QR Dry Pendent
Recessed Sprinkler in ceilings which have positive
Sprinkler Identification Number (SIN): R5714 pressure in the space above.
2.
Model F3QR Dry Pendent Concealed Sprinkler
"A"Dim. TA"to 48"(89mm to 1219mm)in 1/4'(6mm) increments
Inlet Protrusion Elevated
CCP Cover Plate"' Finishes(2) Above Inside Pipe
c __;;r—i---t----r----it F===,r•;l
Standard Finishes I Special Application Finishes ( - _I--14i- V
Chrome Plated i Bright Brass Plated '1 ' '"
White 1 Black Plated ,_-r-,E. -ti
Black Paint r 5
L. o u System Tee
!Off Write i
Sa rome N
"' Utilizes the}2"cover plate with-�'total adjustment. 1" NPT
(21 Other finishes and colors are available on special order.
Consult factory for details. 2 1/2" Dia.
[6.35mm] I
"A" Dimension Hole in Ceiling
Standard Temperature Ratings Adjustment Range 2 19/64" Dia
3/16'
I I Sprinkler [±4.76r.] [58.34mm]
1 Temperature Cover Plate Max
Classification I Rating 'Temp.Rating •Ambient Temp. :: Nominal Position Sprinkler
of Coverplote Cup Assembly
1135°F (57°C) 135°F (57°C) 100°F (38°C)
Ordinary 1155°F (68°C) 135°F (57°C) 100°F (38°C) I
---
__ °►i Coverplote
Intermediate 1200°F (93°C) 165°F (74°C) 150°F (66°C) 1 Celing i ,t„' Assembly
. --HI . •
High* 1286°F (141°C) 165°F (74°C) 150°F (66°C) 1 ` - ll��irl,r Cell_ng>�,
—_u=-
3/16” [4.76mm]
Coverplote Adjustment
Listed and Certified only by cULus.
Note: Do not install the Model F3QR Dry Pendent
Sprinkler Installation Wrench: Concealed Sprinkler in ceilings which have
Model G3 R/C Sprinkler Wrench positive pressure in the space above.
Sprinkler Identification Number (SIN): R5714
Model F3QR .Dry Horizontal Sidewall Sprinkler
"A"Dim. 1 2"to 48'(51 mm to 1219mm)in 14"(6mm) increments .
Finishes`'' 1 1/2" [38.10mm]
Total Adjustment _ ---------�
I Sprinkler Escutcheon
F- r Ceiling
•
Bronze Brass °
.Chrome Plated Chrome Plated L_^] 1.-3-] 4" [101.60mm] Min.
/4" [31.75mm] 12" [304.80mm] Mon
White Painted' White i Escutcheon Adjustment
Ip '� 1/4" [6.35mm]
Other finishes and colors are available on special order. System Tee i V �Escutoheon Adjustment
Consult.factory for details. 1" Np7If
`21 White painted sprinklers will have chrome plated can. \.1 —�;,, I 2 3/32" I._.
IMD
i [53 18mm]i, ;^�` Ill l4 .
llStandard Temperature Ratings -`4 4-, 11-4Ill 1 - n6.omn']
S 'rider _ _ — ——
Pr
Temperature Max. Bulb 2 1/8" Dio. - .-
Classification Rating Ambient Temp. Color [53.98mm] °I'
Hole in Wall t �—1/4" [6.35mm]
Ordinary 135°F (57°C) 100°F (38°C) Orange Protrusion
Sprinkler Car.
Ordinary 155°F (68°C) 100°F (38°C) Red ' �
Intermediate 200°F (93°C) 150°F (66°C) Green .•A" Dimen51on Nominal Position
nt
High 286°F (141°C) 225°F (107°C) Blue Range + 1/4"Ad1/4 [
MJrLO�-C ]
' +6.35mm of Escutcheon
Sprinkler Installation Wrench: Note: The sprinkler Can protrudes 1/4"when escutcheon is
Model G3 Sprinkler Wrench in nominal position. Escutcheon adjustment pro-
vides+1/4"(+6mm)to -11/4"(-32mm)"A"dimension
Sprinkler Identification Number (SIN): R5734 adjustment range.
3.
• Model F3QR Dry Horizontal Recessed Sidewall Sprinkler
I"A"Dim. 3W to 48"(89mm to 11219mm)in 1/4"(6mm) increments
r----- a,n9cc
Finishes"] L. .r _. 4
1 13/32
Sprinkler Escutcheon Escutcheon
r N [35.7r,,,,,]
I_ 4"[101.6mm]Min..
Bronze Brass • -System Tee Cup o I , 12'[304.8mm)Moz.*
Chrome Plated Chrome Plated 1 i;
White Painted White ! I.Nrr
"'Other finishes and colors are available on special order. Consult HIM
factory for details.Cup remains unfinished. "See page 2" '"-
_L1'I���1,-ii i t_�_ _ 3 7/ Dec
Y
• 2 1/2'Din. - i .
[63.5mm]
Note in Won It,
2 19/64'Dio. [_-J .
[58.3mm] i
Standard Temperature Ratings Adjustment"Ronge ~— m]
c"
Escutcheon
AAdjdjustment
157'DO3 +1/2 -0
Sprinkler Max.
[+,2.7m. -0]
Temperature MBulb *.FOR FACTORY MUTUAL(FM)
•
Classification Rating Ambient Temp. Color •4' - 6'FOR UNDERWRITERS LABORATORIES(UL)
Ordinary 135°F (57°C) 100°F (38°C) Orange
Ordinary 155°F (68°C) 100°F (38°C) Red I • .
Intermediate 200°F (93°C) 150°F • (66°C) Green
High* 286°F (141°C) 225°F (107°C) Blue ' Notes:Do not install the Model F3QR Dry Horizontal.
Listed and Certified only by cULus. Recessed Sidewall Sprinkler in walls which have
positive pressure in their side space.
. • Listed by cULus for Quick Response.Approved
Sprinkler Installation Wrench: •
by FM for Standard Response.
ModelGSprinkler Wrench:.
• Recessed Horizontal sidewall sprinklers are listed
p with cULus for installation of min.4"(100mm)-to-
Sprinkler Identification Number (SIN): R5734 max.6"(150mm)below ceiling and approved by
FM for installation of min.4"(100mm)-to-max.
12"(300mm)below ceiling.
Technical Data: Ordering Information
Orifice Size: 1/2" (15mm) Specify:
Thread Size: 1" NPT per ANSI B2.1
Working Pressure: 175 psi (12 bar) 1. Sprinkler Type(select dne): •
Nominal K Factor- US/(Metric): 5.6/(80) (a) Model F3QR Dry Pendent •
Product Description (b)Model F3QR Dry Recessed Pendent
(c) Model F3QR Dry Concealed Pendent
Reliable Model F3QR Dry Sprinklers are quick response
sprinklers utilizing a durable 3mm frangible glass bulb. This (d)Model F3QR Dry Horizontal Sidewall
quick response enables these sprinklers to apply water to a (e)Model F3QR Dry Recessed Horizontal Sidewall
fire much sooner than standard response sprinklers of the 2. Sprinkler Temperature Rating.
similar temperature rating. 3. Sprinkler Finish.
Model F3QR Dry Sprinklers are intended for use in enclosed
dry and preaction systems and in enclosed areas subjected 4. Cover Plate/Escutcheon Finish.
to freezing temperatures, such as freezers and unheated 5. Length:
portions inside buildings. "A" Dimension (face of tee to face of ceiling or wall)
Environments wherein dry sprinklers are employed can be in 1/4°(6mm) increments.
corrosive.For this reason,Model F3 Sprinklers have a special 6. Model F3QR DryPendentis available without
wax fillet placed in the gad between the cup that supports the (a)
bulb and the wrenching Doss.This wax will not interfere with sprinkler can and escutcheon.
the operation of the sprinkler, and it prevents contaminents
from entering the internal portion of the drop nipple.The wax Note:
•
must not be removed.
Operation 1. The "A" dimension is based on a nominally gauged
Theglass bulb consists of an accuratelycontrolled amount B2.1e thread `ads a up" of 0.600" (15mm) per ANSI
B2.1 [7/2 threads approximately].
of special fluid hermetically sealed Inside a precisely 2. All platings and paintings are decorative and
manufactured glass capsule. This glass bulb is specially intended for interior use.
constructed to provide fast thermal response. When the
temperature increases sufficiently, due to a fire, the bulb
shatters allowing operating parts to clear the waterway This
enables the inlet seal to release air or water and subsequently,
cause water flow over the deflector in a uniform spray pattern,
controlling or extinguishing the fire.
4.
•
- • General Installation Instructions • Model G3 Wrench (Fig. 4) is used for installation of
Model F3QR dry sprinklers must be installed only in Pendent and Horizontal Sidewall sprinklers.
standard (ANSI B 16.3 class 150 and ANSI B 16.4 class
125)pipe tees even at branch line ends. They should not • Glass bulb sprinklers have orange bulb protectors to
be installed into elbows and pipe couplings located on minimize bulb damage during shipping, handling and
drop nipples to the sprinklers. For these and other fittings installation. REMOVE THIS PROTECTION AT THE TIME
including CPVC*, the dry sprinkler should be installed THE SPRINKLER SYSTEM IS PLACED IN SERVICE
into a fitting to conform to protrusion into the fitting in ac- FOR FIRE PROTECTION. Removal of the protectors
cordance with the diagrams.The"A"dimension of the dry before this time may leave the bulb vulnerable to
sprinkler, which extends into the freezers or a freezing damage. MASCO wrenches are designed to install
zone from wet pipe systems, should be selected to pro- i sprinklers when covers are in place. REMOVE
vide. as a.,minimum, the specified lengths in inches PROTECTORS BY UNDOING THE CLASP BY HAND.
shown in the following chart, between face of the fitting DO NOT USE TOOLS TO REMOVE THE
and the outside wall or ceiling of the protected area. The PROTECTORS.
following chart is used for freezing zones.when the ambi •
-
ent temperature around the wet pipe system is kept at 40 Maintenance
°F/4°C).and specifies the minimum length for fitting face The Model F3QR Quick Response Dry Sprinklers should
to ceiling or wall (outside) for different protected area be inspected quarterly and the sprinkler system
temperatures. maintained in accordance with NFPA 25. Do not remove
I Length(Face to Ceiling/Wall) Temperature(Protected Area)* the factory applied thermally sensitive wax fillet between
the bulb supporting cup and the wrenching boss. Do not
12 inches/300 mm -20°F/-29°C replace this wax with a substitute substance. An Alternate
1 18 inches/450 mm -40°F/-40°C substance may interfere with proper operation of the
24 inches/600 mm ' -60°F/-51°C°C sprinkler. Do not clean sprinklers with soap and water,
"For temperatures falling between those in the above chart,the ammonia or any other cleaning fluids. Remove dust by .
minimum t lengtheratmay be determined interpolation. using a soft:brush or gently vacuuming. Remove any
sprinkler which has been painted (other than factory
applied) or damaged in any way. A stock of spare
During installation,the following steps must be followed: sprinklers should be maintained to allow quick .
replacement of damaged or operated sprinklers. Prior to
1. Cut the specified size hole (see illustrations) for the installation, sprinklers should be maintained in the original
sprinkler in the ceiling or wall directly in line with the cartons and packaging until used to minimize the potential .
tee. for damage to sprinklers that would cause improper
2. Apply pipe joint compound to the 1" (25mm) pipe operation or non operation.
threads and install sprinkler using the Model G3 or
G3 R/C Sprinkler Wrench as specified. *Spears CPVC sprinkler adapter tees(with steel thread
3. Install the Model FP push-on/thread-off escutcheon or insert) can only be used with horizontal sidewall
CCP cover plate if required. sprinklers which do not require protrusion into tees to
is not rec- prevent ice or debris blockage of sprinkler inlets. These
Note: Installation of the Model F3QR Sprinklers
CPVC tees do not permit sufficient sprinkler inlet
ommended in copper pipe systems, as this may reduce protrusion as required for pendent installation.
the life expectancy of the sprinklers.
•
Model F3QR Concealed and Recessed
Installation Instructions •
• The Model G3 R/C wrench(Fig. 1)is designed to locate
on the wrenching pads of the recessed sprinkler while
centering in the cup. A standard 1/2" drive ratchet may
be used to drive this wrench. Figures 1 and 2 show •
sequentially the insertion of the wrench.First the wrench,
with its jaws above the sprinkler deflector, is moved •
laterally until centered with the cup. Then raise the •
wrench inside of the cup until its jaws engage the
sprinkler's square wrenching pads (Fig. 3). To remove
the wrench,follow this procedure in reverse order. Care
should be taken to avoid striking the deflector, with the
wrench.
•
5.
F
l,W err .. Aii ;
r
•
`s , "7-.•:••.;':,.;::.
• i
Fig. 1 - G3 R/C Wrench Fig. 2 - G3 R/C Wrench Fig. 3 - G3 R/C Wrench
•
. ,,,,f:',':
.
__ ,'.',,:*4 .
k
•
• Fig. 4-G3 Wrench
•
•
•
•
•
•
The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association,Factory Mutual
Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.
Products manufactured and distributed by Reliable have been protecting life and property for over 80 years,and are installed and serviced oy the most highly qualified
and reputable sprinkler contractors located throughout the United States,Canada and foreign countries.
Manufactured b
The Reliable Automatic Sprinkler Co.,Inc. 0 Recycled
IleIja )I (800) 431-1588
(800) 848-6051 Sales Offices
Sales Fax
(914) 668-3470 Corporate Offices Revision lines indicate updated or newPaper data
www,reliablesprinkler corn Internet Address E.G.Printed in USA 3/06 P/N9999970175
Schedule-1O®/Schedule-40®
Fully Listed and FM Approved Sprinkler Pipe
When you specify Schedule-10/Schedule-40 sprinkler pipe you get a UL listed and FM approved product Althougt'these
products do not require separate approvals, Schedule-10/Schedule-40 gives you the extra quality assurance you demand.
Our Sch-10 (1'/4"-8")pipe and Sch-40 (1"-2''4")pipe have passed the same thorough lab testing as our other listed pipe
products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality.
Galvanized Pipe Sch-40 Specifications
• NPS Nominal I.D. Wt. Wt.(H20 Filled) Pcs/ WI/Lift(21') WI/Lift(24') WI/Lift(25')
Schedule-10/Schedule-40 product can be In;mm In;mm Lbs/Ft;Kg/m Lbs/Ft;Kg/m Lift Lbs;Kg Lbs;Kg Lbs;Kg
"hot-dip"galvanized to meet FM
1" 1.049 1.680 2.05 70 2,470 2,822 2,940
requirements for dry systems in
25 . 26.6 2.5 3.05 70 1,120 1,280 1,334
accordance with the zinc coating
specifications of ASTM A-123. 1'A" 1.380 2.270 2.93 51 2,431 2,778 2,894
32 ' 35.1 4.36 4.36 51 1,103 1,260 ' 1,313
Superior Coating 11/2" 1.610 2.720 3.61 44 2,513 2,872 2,992
• 40 40.9 4.0 5.37 44 1,140 1,303 1,357
Our advanced formula mill coating of- 2. 2.067 3.650 5.13 30 2,300 2,628 2,738
fers a clean, durable surface. It is also 50 ' 52.5 5.4 7.63 30 1,043 1,192 1,242
paint-ready for custom color applications --2Yz" 2.469 5.790 • 7.86 19 2,310 2,640 2,750
without special preparation. 65 62.7 8.6 11.73 19 1,048 1,197 1,247
• The internal surface of all black Allied
Tube& Conduit Fire Sprinkler pipe
products up to 4.5000"in diameter is SCh-10 Specifications
coated with our new Antibacterial For- NPS Nominal I.D. WI Wt.(H20 Filled) Pcs/ WI/Lift(21') Wt/Lift(24') Wt/Lift(25')
mula,`ABF". In scientific laboratory In;mm In;mm Lbs/Ft;Kg/m Lbs/Ft;Kg/m Lift Lbs;Kg Lbs;Kg Lbs;Kg
test,ABS proved to have superior resis- 1" 1.097 1.400 1.81 91 2,675 3,053 3,185
tance to microbial colonization of pipe 25 27.9 2.1 2.70 91 1,213 1,385 1,445
walls,thereby delaying or possibly pre- 11/4" 1.442 1.810 2.52 61 '2,319 2,664 2,760
venting the onset of Microbiologically 32 36.6 2.7 3.75 61 1,052 1,208 1,252
Influenced corrosion (MIC)when the 11/2' 1.682 2.080 3.04 61 2,664 3,045 3,172
First Sprinkler System is first installed. .40 42.7 3.1 4.52 61 1,208 1,381 1,439
American Made 2" 2.157 2.640 4.22 37 2,051 2,344 2,442
50 54.8 3.9 6.28 37 930 1,063 1,108
Meets "Buy American"requirement 21/2" 2.635 3.530 5.89 30 2,224 2,542 2,648
and is available through distributors in 65 66.9 5.3 8.77 30 1,009 1,153 1,201
the USA, Canada and Mexico. 3" 3.260 4.330 7:94 19 1,728 1,975 2,057
Specifications & Approvals 80 82.8 6.4 11.82 19 784 896 933
4" 4.260 5.610 11.78 19 2,238 2,558 2,665
90 108.2 • 8.3 17.53 19 1,015 1,160 1,209
Schedule-10/Schedule-40 pipe are in
compliance with the following: 5" 5.295 7.77 17.33 10. 1,632 1,865 1,943
125 134.5 11.56 25.80 10 740 846 881
ASTM A-135, and NFPA 13. Both pipe 6" 6.357 9.290 23.03 10 1,951 2,230 2,322
products have a working pressure rating 150 161.5 13.8 34.27 10 885 1,012 1,053
of 300 psi maximum and also meet the 8" . 8.249 16.490 40.15 7 2,424 2,770 2,885
stringent requirement for the following 200 209.5 24.5 59.75 7 1,100 1,256 1,309
tests:
•Welded Outlets el ® U LC
• Hydrostatic Pressure
• Side Wall Rupture Listed Approved Listed
•Vibration Test
Vico/Row Control allied 16100 S. Lathrop • Harvey, IL 60426 Customer Service:
11350 Norcom Rd. • Philadelphia, PA 19154 (800)882-5543
TUBE&CONDUIT 2525 N. 27th Ave. • Phoenix,AZ 85009 Fax 708-339-1806
S5 - 3
C �I SC± 'ATE/ TIME NV
CITY OF ORONOD IN �.�
INSPECTION NOTICE SCHEDULED / y\"
PERMIT NO.o7O//-DD a-L/9 /4:1 COMPLETED /� �I
ADDRESS 01DD W (0. JL Ui vim/ !/'/
OWNER TONE NO`70,3 "S�V3'�BTS`"
CONTRACTOR ..:.-S.4.400 a. i� 6��TJ K/
•
• DESCRIPTION i1 . s'� A
44 ❑ FOOTING NMBI INAL ❑ EXCAV/GRADING/FILLING
4.
Q ❑ POURED WALL ❑ MECHANICAL RI ❑ LAKESHORE/WETLANDS
h ❑ FRAMING ❑ MECHANICAL FINAL
TREE❑ REMOVAL
• ❑ INSULATION ❑ WOOD BURNER/FIREPLACE ❑ SITE INSPECTION
Q ❑ RADON SLAB ❑ WATER HOOK-UP ❑ PROGRESS
❑ FINAL ❑ SEWER HOOK-UP ❑ COMPLAINT
• ❑ DEMO-SITE ❑ SEPTIC MAINT. ❑ FOLLOW-UP
_ ❑ DEMO-FINAL ❑ SEPTIC INSTALL ❑ HARD COVER REMOVAL
❑ PLUMBING RI ❑ SEPTIC FINAL ❑ FOUNDATION/REMOVAL
Z OWNER/CONTRACTOR TO MEET YOU:_YES_NO
o COMMENTS:
CC
W
Q..
CC
0
CC
O
W
CC
coW
W
cc
O
WCC ❑WORK SATISFACTORY:PROCEED PROJECT COMPLETE
❑CORRECT WORK&PROCEED ❑ I UE CERTIFICATE OF OCCUPANCY
0 ❑CORRECT WORK,CALL FOR REINSPECTION TEMPORARY
✓ BEFORE COVERING PERMANENT
❑CORRECT UNSAFE CONDITION WITHIN HOURS. ❑ PHOTO TAKEN
INSPECTOR WILL RETURN
❑STOP ORDER POSTED.CALL INSPECTOR ❑CITATION ISSUED
❑ INSPECTION REQUIRED.CALL TO ARRANGE ACCESS.
Call for the next inspection 24 hours in advance. (952) 249-4600
Owner/Contractor on site: E
Inspector. /
White Copy/Inspector's File Canary Copy/Site Notice