HomeMy WebLinkAboutOnsite sewage treatment system CITY OF ORONO 0. Municipal Offices O O Post Office Box 66 Crystal Bay, MN 55323-0066r` r ON–SITE SEWAGE TREATMENT . A r � � T n INSPECTION REPORT 9kESI3.Og� Owner: / yam i..;4,13-6/ api Address: /14.46/Z04 .e4 /4/h46911:9 Q'&4 Permit #'s: I)iiv, Dates: -- Contractors: — City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is -an existing system [ ] new construction) SYSTEM CONFORMITY (1-3): 2 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input 6) without discharging any pollutants into ground or surface waters. "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic [ ] has or ,j,41 has not been identified at this time. If the limiting soil characteristic has not been identified, this classification may be subject to revision.) TANK CONDITION (5-10): - Taq(C inspection indicates: C57 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped out now. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been pumped out within the last three years, they should be pumped out now. DRAINFIELD CONDITION (11-14): s/ Dnfield inspection indicates: Drainfield is dry, no surfacing evident. 12 Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (slope,setbacks,etc.): POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): ,M; COMMENTS: Sirs Rrr/ , Date of Inspection -eptic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the system location and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner CITY OF ORONO Municipal Offices O O Post Office Box 66 = �, Crystal Bay, MN 55323-0066 ‘,4 " 1 ON-SITE SEWAGE TREATMENT A).' � INSPECTION REPORT . Sv kesrao Owner: /4 �A ra4,1- 7 / /�/� Address: evg99 .141'rgi9 &fris ( o si - /fret Permit #'s: //a1)2, Dates: Contractors: — City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is 34 an existing system [ ] new construction) SYSTEM CONFORMITY (1-3): 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting-isoil characteristics. (The limiting soil characteristic [ ] has or 14 has not been identified at this time. If the limiting soil characteristic has not been identified, this classification may be subject to revision.) TANK CONDITION (5-10): /0 Tank inspection indicates: 5 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped out now. 10 Inspection pipe is located direct, over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been pu out within the last three yearsthey should be pumped out now. DRAINFIELD CONDITION (11-14): t,' Drainfield inspection indicates: 11 Drainfield is dry, no surfacing evident. 12 Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. 1?Drainfield extent and condition unknown. LIMITING SITE FACTORS (slope,setbacks,etc.): POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): /'Rhee 1' COMMENTS: Y-aJ-`fa Date of Inspection ptic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the system location and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner CITY OF ORONO 641---- ) Municipal Offices O Post Office Box 66 - � Crystal Bay, MN 55323-0066 t ON—SITE SEWAGE TREATMENT ,� 14. iir 4INSPECTION REPORT �•. ,M4Io if...4/Zafia ktsxoOwner: thfl1 ekUAddress: cf203 /,4z7! E71 (ik n', Permit #'s: Ay2r>€, Dates: `--- Contractors: id?k.01.,),—.. City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This isan existing system [ ] new construction) SYSTEM CONFORMITY (1-3): 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. "CONFORMING SYSTEM"-A system which does not meet alt the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic [ ] has or has not been identified at this time. If the limiting soil characteristic has not been identified, this classification may be subject to revision.) TANK CONDITION (5-10): qinspection indicates: Pumpout not needed at this time. Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped out now. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been pupped out within the last three years, they should be pumped out now. DRAINFIELD CONDITION (11-14): < Drainfield inspection indicates: 11 Drainfield is dry, no surfacing evident. 12 Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. 0 Drainfield extent and condition unknown. LIMITING SITE FACTORS (slope,setbacks,etc.): POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): 1����1�ii/ --�, COMMENTS: �'�f Date of Inspection Sep` c Sys em I Spector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the system location and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner CITY OF ORONO O Municipal Offices O O Post Office Box 66 Crystal Bay, MN 55323-0066 \ ;74r Al ON-SITE SEWAGE TREATMENT IA 1.411 ' kEsHag INSPECTION REPORT Owner: UdayZ464.149/61.1Address: V-e93 hGL Z kt ad. Of;K.)- -<1}eikt)r- Permit #'s: Pal . Dates: Contractors: 11/)YYJ/.1/Y--, City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is i 4 an existing system [ ] new construction) SYSTEM CONFORMITY (1-3): eve 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input Vwithout discharging any pollutants into ground or surface waters. ?/ "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic [ ] has or has not been identified at this time. If the limiting soil characteristic has not been identified, this c assification may be subject to revision.) TANK CONDITION (5-10): Tinspection indicates: PPumpout not needed at this time. Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next punpout. If tanks have not been pumped out within the last three years, they should be pumped out now. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulatic If tanks have not been pumped out within the last three years, they should be pumped out now. DRAINFIELD CONDITION (11-14): / ' Dpi field inspection indicates: (1Y Drainfield is dry, no surfacing evident. 2 Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspecto immediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (slope.setbacks,etc.): POTENTIAL FOR SYSTEM FAILURE (depends on soils,watertable,etc.): ,,e.,/. COMMENTS: �ff�� i' I_ 46111r ,i/Zi Date of Inspection Septi Syste Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the system location and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner , 017. ° 0 I - ` "c CITY of ORONO **..4,4 �►� 4;1 . (� .yE'' Municipal Offices ''?f' i G Street Address: �� 1t=.+ �` � Mailing Address: kE8>~Idg2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 Owner: w c'c't 2A'c6\ °v'N t r._ C\ Address: c),Oo w c\yZ-4 fiti t3 I V().- City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFORMITY (1-3): �) "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. 2" "COMPLIANT SYSTEM" An ISTS which does notee m tall the location,design and construction standards of the current Orono Municipal Code but does meet the three foot separation requirement,and which is not failing or an imminent threat to public health or safety. "NON-COMPLIANT NON-COMPLIANT SYSTEM A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. TANK CONDITION(5-10): (-) Tank inspection indicates: 5 Pumpout not needed at this time. 0 Tank must be pumped out this year (city code requires tanks to be pumped out every 3 years. Tank was last pumped V r r`O weN ) 7 Solids accumulation in tanks is at a critical a critical leveL Tanks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. 9 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank at next pumpout If tanks have not been pumped out within the last three years,they should be pumped out now. 10 Inspection pipe is located directly over tank baffle(does not give accurate measurement of solids accumulation). If tanks have not been pumped out within the last three years,they should be pumped out now. Di IELD CONDITION(11-14): \\ 11 Drainfield is dry,no surfacing evident. Some evidence of surfacing,not critical yet. • • 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately.Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. COMMENTS: S 1 St(c— \OAKS b‘(-,_ P 0 Pr.1 -ti4,,S \O —�--o \ G)1,\ cc . 8-ctUt/zn,p.,,, Date of Inspection Septic System Inspector { Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current ennrt;r;,,,,,..,—a,....t,.nvn;tnht. CITY OF ORONO O Municipal Offices O Post Office Box 66 = p_ Crystal Bay, MN 55323-0066 ON—SITE SEWAGE TREATMENT Art. INSPECTION REPORT 9kESIOA Owner: W4----12/ 7 r COu /2-1(Jt1 Address: 2OD W4-/Z4114- &v1) (5539 i) lO r l8 Permit #'s: /O/19 Dates: Li— ZO— 78 Contractors: C�/O t.'E L (4, 1/ Co, City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is te an existing system l ] new construction) SYSTEM CONFORMITY (1-3): I "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic I ] has or l ] has not been identified at this time. If the limiting soil characteristic has not been identified, this classification may be subject to revision.) TANK CONDITION (5-10): S inspection indicates: �L55JJ Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped out now. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been pumped out within the last three years, they should be pumped out now. DRAINFIELDCONDITION (11-14): /r = Dield inspection indicates: Drainfield is dry, no surfacing evident. Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (slope.setbacks,etc.): w o4-te,z-1-f idt. POTENTIAL FOR SYSTEM FAILURE (depends on soits.water table,etc.): /0(A) COMMENTS: M v Su l'LP-14-cutq UJi e/ l b'L 57 S? LV Ci 'PA.() I vl Sp,P G7'C%8/l2 04j Date of Inspection Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the system location and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner °4 0 &,7 ,Y N CITY of ORONO . •1A ;i , : h A Municipal Offices \� t 1:;} t ;�. 4/ Street Address: Mailing Address: �E81; %' 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 To Current Owner: Address: a©0 \^--,yZe= =, 1 IVCD . City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFORMITY (1-3): t \./ "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and which is not failing or an imminent threat to public health or safety. 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. TANK CONDITION(5-7): S T�nlc inspection indicates: 5 Pumpout not needed at this time. c 6 Septic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years. Tank was last pumped _). Make sure septic tanks are pumped through manhole and not through white inspection pipes. This allows for the proper cleaning. Keep water softner and iron filter discharge out of septic system. 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4" dia.pipe)must be installed in each tank. If tanks have not been pumped out within the last three years,they should be pumped out now. D INFIELD CONDITION(8-10): d' 8 Drainfield is dry,no surfacing evident. 9 Some evidence of surfacing,not critical yet. 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. COMMENTS: b`e<.;r••.tO 1066 dk Pe.cd C4/ �'� :of. j- inS `rc4.z1., pio k Q^ 54, I(= - ..r. n•Cc bu:0i i- I z-3--01 GN-Not,<hilITL:, - Date of Inspection Matt Bolterman - Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. Telephone(952)249-4600 • Fax(952)249-4616 www.ci.orono.mn.us 4!), fO \ . _� ., 1 , CITY of ORONO \s, It. p;;; 4:•: - Is, Municipal Offices 4 ` \ s ',,c,t -1'•' `.. G Street Address: 9 ,: , ; .e 4�/ Mailing Address: 2750 Kelley Parkway P.O. Box 66 �ESI;� Orono, MN 55356 Crystal Bay, MN 55323.0066 To Current Owner: Address: `a.0 C levcvy-z_Pct-4‘ t)V G) City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFORMITY (1-3): 1 CJ "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and which is not failing or an imminent threat to public health or safety. 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. TANK CONDITION(5-7): oikinspection indicates: Pumpout not needed at this time. 6 Septic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years. Tank was last pumped ). Make sure septic tanks are pumped through manhole and not through white inspection pipes. This allows for the proper cleaning. Keep water softner and iron filter discharge out of septic system. 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If tanks have not been pumped out within the last three years,they should be pumped out now. DRAINFIELD CONDITION(8-10): CODrainfield is dry,no surfacing evident. 9 Some evidence of surfacing,not critical yet. 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. COMMENTS: pj D,,-:rc,A.\l d-- fi�c.-1(- \obk- 4t--.,_ \ 0 ,--L.,- ._,- 6)---42r-, a__, Date of Inspection Matt Bolterman- Septic System Inspector Note:In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion ofthe adequacy of the system under current conditions based on the available information. Telephone(952) 249-4600 • Fax(952)249-4616 www.ci.orono.mn.us