Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
International Buld code review summary
INTERNATIONAL BUILDING CODE REVIEW SUMMARY PROJECT: Wayzata Country Club Renovation and Addition Project Address PROJECT NUMBER: WCC0301 DATE: January 2004 APPLICABLE CODES INTERNATIONAL BUILDING CODE: 2000 Edition ACCESSIBILITY CODE 2003 Chapter 1341 STATE BUILDING CODE: 2003 Amendments A.OCCUPANCY CLASSIFICATION [Section 302.1,Table 302.3.3) GROUP DESCRIPTION OF AREA A-2 Restaurant/Ballroom B Offices S-2 Storage ACCESSORY USE AREA(IF ANY): [Section 302.2] (No fire barrier is required between areas occupying 10%or less than the total floor area of a building.) MIXED OCCUPANCY RESTRICTIONS(IF ANY): [Section 302.3] A-2 to B=1-hour separation required B to S-2=1-hour separation required INCIDENTAL USE AREAS(IF ANY): [Table 302.1.1] Storage locations over 100 sq.ft.as indicated on plan-1 hour separation required. Laundry rooms over 100 square feet-1 hour separation required. Boiler rooms over 15 psi and 10 horsepower-automatic sprinkler system. Waste and linen collection rooms over 100 square feet-1 hour separation required. B.TYPE OF CONSTRUCTION [Table 601,Section 602] TYPE 3II-B (new construction at addition) TYPE V-B (existing construction and remodeling) C.EXTERIOR WALL AND OPENING PROTECTION [Table 602,Section 704.12] FIRE RESISTANCE REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCE: Less than 5 feet-Group A,B,M,S-2;1 hour required separation Greater than or equal to 5 feet and less than 10 feet-Group A,B,M.S-2;1 hour required separation Greater than or equal to 10 feet and less than 30 feet-Group A,B,M,S-2;no required separation At least or greater than 30 feet-Group A,B,M,S-2;no requirement D.ALLOWABLE HEIGHTS AND BUILDING AREA [Table 503] HEIGHT MODIFICATIONS: [Section 504] ALLOWABLE AUTOMATIC ACTUAL CONST.TYPE OCCUPANCY HEIGHT SPRINKLER INCREASE HEIGHT II-B S-2 55 feet +20 feet=75 feet ?feet(average height) ALLOWABLE AUTOMATIC ACTUAL CONST.TYPE OCCUPANCY STORIES SPRINKLER INCREASE STORIES V-B A-2 1 +1 story=2 stories 1 B 2 +1 story=3 stories 1 S-2 2 +1 story=3 stories 2/3 AREA MODIFICATIONS: [Section 506,Equations 5-1 and 5-2] Sprinkler Increase= 200%(multi-storied buildings) Frontage Increase= 100[256/929-0.25]30/30=2.56% (Public way on north side only) Floor area increase= Group A-2: 6,000+[(6,000 x 75)1100]+[(6,000 x 200)/100]=22,500 s.f.per floor Group B: 9,000+[(9,000 x 75)/100]+[(9,000 x 200)/100]=33,750 s.f. per floor Group S-2: 13,500+[(13,500 x 75)/100]+[(13,500 x 200)/100]=50,625 s.f. per floor UNLIMITED AREA ALLOWANCE APPLICABLE: [Section 507] YES NO BUILDING AREA: ACTUAL AREA ALLOWABLE AREA Sub-basement Group S-2 Shop/Office 291 Trash 222 Receiving 408 Smoking Room 118 Electrical Room 209 FLOOR TOTAL= 1,248 50,625 Ground Floor Group B Women's Locker Room 4,047 Men's Locker Room 5,315 Employee Lockers 190 Employee Break 500 Offices 450 Group M Pro Shop 1,700 Group S-2 Seasonal Storage 410 Laundry 583 Mech/Storage 480 Mechanical 1,687 Future use 2,172 Golf Bag Storage 1,180 FLOOR TOTAL= 18,714 33,750 First Floor Group A-2 Casual Dining 2,220 Bar 1,234 Formal Dining 1,860 Living Room 920 Garden Room 387 Wayzata Room 750 Pre-function Area 1,088 Grand Ballroom 3,486 Bar Deck 910 Casual Dining Deck 722 Group B Kitchen 6,246 Valet 90 Group S-2 Coats 200 Wine Room 150 Storage 1,090 FLOOR TOTAL = 21,353 22,500 Second Floor Group B Offices 1041 Board Room 696 Work Room 105 Reception 330 Accounting 594 Storage 529 Mechanical 7000 FLOOR TOTAL= 10,295 33,750 BUILDING TOTAL 51,610 140,625 E.FIRE RESISTIVE REQUIREMENTS BY TYPE OF CONSTRUCTION [Table 601] CONSTRUCTION TYPE:II-B and V-B CONDITION REQUIREMENT NOTES 1.STRUCTURAL FRAME None 2.BEARING WALLS-EXTERIOR None 3.BEARING WALLS-INTERIOR None 4.NONBEARING WALLS-EXTERIOR None See item C above 5.NONBEARING WALLS-INTERIOR None 6.FLOOR CONSTRUCTION None 7.ROOF CONSTRUCTION None F.OCCUPANT LOAD AND EXITING REQUIREMENTS [Table 1003.2.2.2,Section 1003.2.2,1003.2.3,Table 1004.2.1] (Refer to plan for more information.) SQ.FT. ACTUAL OCC.LOAD REQ'D ACTUAL OCCUPANCY CATEGORY PER OCC. SPACE DESCRIPTION AREA FACTOR EXITS EXITS SUBBASEMENT Accessory Storage 300 Shop/Office 291 1 1 1 300 Trash 222 1 1 1 300 Receiving 408 2 1 1 300 Electrical Room 209 1 1 2 Business 100 Smoking Room 118 2 1 1 GROUND LEVEL SUBTOTALS 1,248 7 GROUND FLOOR Locker Rooms 50 Women's Locker Room 4,047 81 2 2 50 Men's Locker Room 5,315 107 2 2 50 Employee Lockers 190 4 1 2 Assembly 15 Employee Break 500 34 1 1 Business 100 Offices 450 5 1 1 Mercantile 30 Pro Shop 1,700 57 2 2 Accessory Storage/Meeh 300 Seasonal Storage 410 2 1 1 300 Laundry 583 2 1 1 300 Mech/Storage 480 2 1 1 300 Mechanical 1,687 6 1 1 300 Future use 2,172 8 1 1 300 Golf Bag Storage 1,180 4 1 1 FIRST LEVEL SUBTOTALS 18,714 312 FIRST FLOOR Assembly(tables&chairs) 15 Casual Dining 2,220 148 2 5 15 Bar 1,234 83 2 2 15 Formal Dining 1,860 124 2 4 15 Living Room 920 62 2 2 15 Garden Room 387 26 1 2 15 Bowman Room 750 50 1 3 15 Pre-function Area 1,088 73 2 2 1 15 Grand Ballroom 3,486 233 2 3 15 Bar Deck 910 61 2 3 15 Casual Dining Deck 722 49 2 2 Kitchen,commercial 200 Kitchen 6,246 32 1 7 Business 100 Valet 90 1 1 1 Accessory Storage 300 Coats 200 1 1 1 300 Wine Room 150 1 1 1 300 Storage 1,090 4 1 1 FIRST LEVEL SUBTOTALS 21,353 948 SECOND FLOOR Business 100 Offices 1041 11 1 1 100 Board Room 696 7 1 1 100 Work Room 105 2 1 1 100 Reception 330 4 1 2 100 Accounting 594 6 1 2 Accessory Storage/Mech 300 Storage 529 2 1 2 Accessory Storage/Mech 300 Mechanical 7000 24 1 2 SECOND LEVEL SUBTOTALS 10,295 56 BUILDING TOTALS 51,610 1323 G.EXITING REQUIREMENTS [Table 1003.2 3] OCCUPANCY F-1 OCC. REQ'D ACTUAL REQ'D ACTUAL AREA LOAD EXIT WIDTH* EXIT WIDTH STAIR WIDTH** STAIR WIDTH (inches per occupant=0.15) (inches per occupant=0.2) Ground Floor-North 1 42 6.30 72 8.40 N/A Ground Floor-North 2 29 4.35 36 5.80 N/A Ground Floor-North 3 358 53.70 68 71.60 N/A Ground Floor-South 1 41 6.15 36 8.20 N/A Ground Floor-South 2 54 8.10 36 10.80 N/A Ground Floor-South 3 203 30.45 36 40.60 48 First Floor-West Entry 194 29.10 72 38.80 N/A First Floor-South 1 1 0.15 36 0.20 N/A First Floor-South 2 38 5.70 64 7.60 N/A First Floor-South 3 61 9.15 72 12.20 N/A First Floor-South 4 116 17.40 36 23.20 N/A First Floor-North 194 29.10 72 38.80 48 Sub-basement 6 0.90 36 1.20 N/A * Door width shall not be less than 32 inches clear [Section 1003.3.1.1] ** Stairway width shall not be less than 44 inches [Section 1003.3.3] EXIT ACCESS TRAVEL DISTANCE: [Table 1004.2.4] OCCUPANCY ALLOWABLE* ACTUAL MAX. A,M 250 feet 210 feet B 300 feet 120 feet S-2 300 feet 185 feet *with sprinkler system H. PLUMBING SYSTEMS [Table 2902.1] MINIMUM NUMBER OF PLUMBING FACILITIES Occupancy Type No.of Occupants Water Closets/Urinals Lavatories Drinking Fountains Other Req'd Actual Req'd Actual Req'd Actual Req'd Actual Restaurant-First 838 6 male 7 male 2 male 3 male 2 1 1 service 1 service Floor 6 female 7 female 2 female 5 female sink sink Business-Second 1 male 1 male 1 service 0 service Floor 26 1 female 1 uni-sex* 1 female 1 uni sex 1 0*' sink sink Storage-Ground 2 male 6 m le 2 male 8 male 1 service 2 service Floor&Sub 283 2 female 7 fe le 2 female 6 female 1 1 sink sinks basement Imeiy- 1.12vil &e.ce,e-5.119(e,