HomeMy WebLinkAbout1998 Site Plan101998 Westwood Professional Services, Inc,
t
u7
N
L0
N
I S89050'08 -W 99.30
—� J y
OD
t Drainage acrd—Y C"I
', i uti/rty Easement � i �
ISO
ysb1 0 84.{3 Lt3 N
l
��., °�� Sept 2 c r-
17.5
\\ S'Zte
�- ested d s'
o ` well lo�aM0/7 1306lump tank �.'
,CPsb2
� \ '
e
�¢ 1 ! 39.5 ' W
50 fol70\goCCon
d� \ cost Sea tic t ks 1 sA
/ i M
sb3 �
0S SJtic t!7!?CCSCA-
C;.'.
sb4�,.�,�, i 1
09
..� 20
5
ED
ao
Benchmark
Top of rebar
elegy =100 0
LEGEND
ff ( lCPCP
65.6 as \
1611.b
k arrd1`i/r't�E ase \ C1
S788055, 0
05-t''-- \
424.E «6
\ ~
_\O
.__
percolation test hole
soil boring
- - - - - existing elevation contour
92*4 existing spot elevation
F9_2_*_41 proposed spot elevation
ECevctions relative and assumed
❑ Fle vations relative to U S. G. S. 1029 N G VD
Denotes proposed surface drainage
Bearing are based on assumed data
0 Denotes iron monument set
i Denotes iron monument found
REVISIONS
L •�
Westwood
Westwood Professional Services, Inc
104 Marty Dr. Suite 3
Buffalo, MN 55313
612 682-2587
GRAPHIC SCALE
40 0 20 40 80
( IN FEET )
1 inch = 40 ft.
I hereby certify at this pion was prepared by me
x under my r t supervision and that 1 am a
July
register ROl^ESSIONAL LAN SURVEYOR under
the laws of a State of Minn
' I �► _' - t�No.23002
DRAWN BCM
CHECKED SAG
4 CL_k C")us_ L I C-6
I --� C�' C '_ )_X P .
ORONO
COPY
LEGAL DESCRIPTION.-
Lot 5, Block 2 CRYSTAL CREE_A< according to the recorded ..,
plat thereof, Hennepin County, Vl;?nesota.
160
CITY OF ORONU
SITE PLAN GRADING PLA
U-APPROVED 6-W ("55
0 D) SAPR 0 `EI7
sy
DATE
ELEVA TIONS
Lowest floor elev. = 88.2
Top of foundation elev. = 96.9
Garage floor elev. = 96.5
Primary Mound Quantities
3/4"-2 1/2" clean rock for rock bed — 2_.3f cubic yards
Clean Sand fill — 140t cubic yards
topsoil for cover — 70± cubic yards
Loamy sand for cap — 18f cubic yards
Quantities do not include waste
Notes:
1. Avoid compaction of mound area before, durintc and
after construction
2. Verify before drilling that no septic tanks or septic areas
are within a 50 foot radius of proposed well location.
(100 feet for shallow well)
J. Verify before construction that no shallow wells are within
100 feet, or deep wells within 50 feet of proposec septic
tanks or mound area.
4. To extend the life of septic system pump septic tanks a
minimum of every 2 ,years
5. See attached sheets for additional construction details.
6. Soil Classified as Lester loam(i-rB) 2-69' slopes:
according to the U.S. Department of Agriculture soil Survey
7. Site plan prepared by or under the supervision of Bernle
Miller- M.P. C.A. License No. 4.3
Septic System Site Pian
Certificate of Survey
Date
PERPARED FOR:
DATE
10!113198
Pillar lues
18995 31st Puce N.
,sae Na.
Plymoew M.
98761
9P
� t
�' '�� `�---F` x
S
?.;.. ..;;.•t'.:
s° ria==,. i