Loading...
HomeMy WebLinkAbout1998 Site Plan101998 Westwood Professional Services, Inc, t u7 N L0 N I S89050'08 -W 99.30 —� J y OD t Drainage acrd—Y C"I ', i uti/rty Easement � i � ISO ysb1 0 84.{3 Lt3 N l ��., °�� Sept 2 c r- 17.5 \\ S'Zte �- ested d s' o ` well lo�aM0/7 1306lump tank �.' ,CPsb2 � \ ' e �¢ 1 ! 39.5 ' W 50 fol70\goCCon d� \ cost Sea tic t ks 1 sA / i M sb3 � 0S SJtic t!7!?CCSCA- C;.'. sb4�,.�,�, i 1 09 ..� 20 5 ED ao Benchmark Top of rebar elegy =100 0 LEGEND ff ( lCPCP 65.6 as \ 1611.b k arrd1`i/r't�E ase \ C1 S788055, 0 05-t''-- \ 424.E «6 \ ~ _\O .__ percolation test hole soil boring - - - - - existing elevation contour 92*4 existing spot elevation F9_2_*_41 proposed spot elevation ECevctions relative and assumed ❑ Fle vations relative to U S. G. S. 1029 N G VD Denotes proposed surface drainage Bearing are based on assumed data 0 Denotes iron monument set i Denotes iron monument found REVISIONS L •� Westwood Westwood Professional Services, Inc 104 Marty Dr. Suite 3 Buffalo, MN 55313 612 682-2587 GRAPHIC SCALE 40 0 20 40 80 ( IN FEET ) 1 inch = 40 ft. I hereby certify at this pion was prepared by me x under my r t supervision and that 1 am a July register ROl^ESSIONAL LAN SURVEYOR under the laws of a State of Minn ' I �► _' - t�No.23002 DRAWN BCM CHECKED SAG 4 CL_k C")us_ L I C-6 I --� C�' C '_ )_X P . ORONO COPY LEGAL DESCRIPTION.- Lot 5, Block 2 CRYSTAL CREE_A< according to the recorded .., plat thereof, Hennepin County, Vl;?nesota. 160 CITY OF ORONU SITE PLAN GRADING PLA U-APPROVED 6-W ("55 0 D) SAPR 0 `EI7 sy DATE ELEVA TIONS Lowest floor elev. = 88.2 Top of foundation elev. = 96.9 Garage floor elev. = 96.5 Primary Mound Quantities 3/4"-2 1/2" clean rock for rock bed — 2_.3f cubic yards Clean Sand fill — 140t cubic yards topsoil for cover — 70± cubic yards Loamy sand for cap — 18f cubic yards Quantities do not include waste Notes: 1. Avoid compaction of mound area before, durintc and after construction 2. Verify before drilling that no septic tanks or septic areas are within a 50 foot radius of proposed well location. (100 feet for shallow well) J. Verify before construction that no shallow wells are within 100 feet, or deep wells within 50 feet of proposec septic tanks or mound area. 4. To extend the life of septic system pump septic tanks a minimum of every 2 ,years 5. See attached sheets for additional construction details. 6. Soil Classified as Lester loam(i-rB) 2-69' slopes: according to the U.S. Department of Agriculture soil Survey 7. Site plan prepared by or under the supervision of Bernle Miller- M.P. C.A. License No. 4.3 Septic System Site Pian Certificate of Survey Date PERPARED FOR: DATE 10!113198 Pillar lues 18995 31st Puce N. ,sae Na. Plymoew M. 98761 9P � t �' '�� `�---F` x S ?.;.. ..;;.•t'.: s° ria==,. i