HomeMy WebLinkAboutOnsite sewage treatment system O O '
0./V.
(, I' CITY of ORONO
!; Municipal Offices
•
Street Address: Mailing Address:
�kESIIp¢ 2750 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323-0066
To: The Current Owner of Address 1--/ 5 `i S (---) ,44-e-1:4oc-A-1
City Ordinance requires that onsite sewage treatment systems in Orono be
inspected on a periodic basis. The onsite sewage treatment system at the above
address has been inspected and the following is known about the system. A
sketch of the known components of the system is available for most properties at
the Orono City Hall.
Imminent Public Health Threat
Yes _
No ✓
If yes, please contact the Onsite Systems Manager at 952-249-4626 within 10
days of receipt of this notice. The septic system must be brought into compliance
within 90 days. Failure to do so will result in referral to the City Attorney for
legal action.
System Identified as Non-Compliant
Yes
No ✓
If yes, system must be brought into compliance by:
December 31, 2007
December 31, 2010
•
Other
Septic Tank(s) Pump out Needed
Yes
No
The City recommends the septic tank(s) and/or lift tank be serviced and pumped
out every three years. City records indicate the tank(s) were last pumped out on
- 7-0 S . The tank(s) should be cleaned through the manhole and
not through the inspection pipes, this allows for proper cleaning.
Comments:
•
.0.6.),ZZLe 4,V
Inspector: ate of Inspection .
Telephone(952)249-4600 • Fax(952)249-4616
www.ci.orono.mn.us
O
0 0
- CITY of ORONO
•,�'. y �'� s • titi/i Municipal Offices
,t, ' •' ' "/ Street Address: Mailing Address:
\Egger 2750 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323-0066
To Current Owner: Address: y S. 4 S Wa-i-cr to wry
City Ordinance 199 requires that each existing on-site sewage treatment system in Orcno be inspected every two years.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below.
SYSTEM CONFORMITY (1-3): L
` .j) "CODE SYSTEM" An ISTS which meets all the location,design and construction stand.:...,-:15 of the current Orono Municipal Code.
2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location.design and cc.-struct:on standards of the current Orono Municipal
Code but does meet the three foot separation requirement or two foot requirement for syster:s instaJed 1996 or earlier,and which is not failing or
an imminent threat to public health or safety.
3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISIS located within a desiar z d IOC-year flood plain,any ISTS which may
or may not meet all the location,design,or construction standards of the current Orono M.:icipal Code and which is failing for any reason:and
any ISTS with less than three feet of unsaturated soil or sand between the distribution devi and the limiting soil characteristics.
TANK CONDITION(5-7):
Tank inspection indicates:
5 Pumpout not needed at this time.
Septic tanks must be pumped out this year (city code requires tanks to be pumped or.t once every 3 years.
Tank was last pumped C-11— b 0 ).
Make sure septic tanks are pumped through manhole and not through white inspection pipes. This allows for the
proper cleaning. Keep water softner and iron filter discharge out of septic system.
7 Inspection risers missing-tanks could not be inspected. Inspection risers(4",f.a. pipe)must be installed in each tank_ If
tanks have not been pumped out within the last three years,they should be pumped out now.
INFIELD CONDITION(8-10): T3
8 Drainfield is dry,no surfacing evident.
9 Some evidence of surfacing, not critical yet.
10 Drainfield is saturated and visibly discharging untreated effluent to the surface_ Contact the City Inspector
immediately. Repairs must be completed within 90 days.
COMMENTS: IAo u'^ \ O ckS O�-, P 'r1$ Ser fic,r k5 )4‘/-t )",v
no 4- b(L. \c\5)r v
m41.1 C-v1 CI-34; G i(S VO Cr'
tcaS
C\ ) ric1,-U
o 5-0 o c ��' -t�,►►�c�
Date of Inspection Matt Bolter.-.;t - Septic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transferafprcperty,be advised that this report does not guarantee
or certify that an existing system will continue to function properly,but is merely an opinion ofthe adequacy of±e s}c-m under current conditions based on the available
information.
Telephone(952)249-4600 • Fax(952)249-4616
www.ci.orono.mn.us
i: ()40
, 0,,. CITY of ORONO
\ Ij ,; _. ,I� 4, Municipal Offices
� lil,�-�' �G Street Address: Mailing Address:
g04'
P.O. Box 66 2750 Kelley Parkway
Orono, MN 55356 Crystal Bay, MN 55323-0066
Owner: D-e-c-s,-- l , `6 \ Address: I-15H 5 vvck+ertow-,. Ki
City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below.
SYSTEM CONFORMITY (1-31: I
10 "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code.
2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono Municipal
Code but does meet the three foot separation requirement,and which is not failing or an imminent threat to public health or safety.
3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may
or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any reason;and
any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics.
TANK CONDITION(5-10): S
T inspection indicates:
5 Pumpout not needed at this time.
T
6 Tank must be pumped out this year (city code requires tanks to be pumped out every 3 years. Tank was last pumped C—J r
—6 C) ).
7 Solids accumulation in tanks is at a critical a critical level Tanks should be pumped out as soon as possible.
8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge.
9 Inspection risers missing-tanks could not be inspected Inspection risers(4"dia.pipe)must be installed in each tank at next pumpout If tanks
have not been pumped out within the last three years,they should be pumped out now.
10 Inspection pipe is located directly over tank baffle(does not give accurate measurement of solids accumulation). If tanks have not been pumped
out within the last three years,they should be pumped out now.
II• • I I LD CONDITION(11-141: \\
• eld is dry,no surfacing evident.
12 Some evidence of surfacing,not critical yet
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately.Repairs must be
completed within 90 days.
14 Drainfield extent and condition unknown.
COMMENTS: S —I S-TP 1 Dd\CS d K
•
Date of Inspection Septic System Inspector
Note: In the event that this inspectionreport is used to
ep satisfy the requirements'for a moitgage or other transfer of property,be advised that this report does not guarantee
or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available
information.
gv O
CITY OF ORONO
Municipal Offices O O
Post Office Box 66 '=-
,4 Vie.
Crystal Bay, MN 55323-0066 , 1' ON—SITE SEWAGE TREATMENT
IA 41) & INSPECTION REPORT
Prir 4s&
9-aZsHo4
Owner: \) E t t-- 'Ego 11 Address: (.7r`1 S (l,�c<4-6-7001.V /d (553759)
Permit #'s: 6 (71 Dates: 4 --(c(' 91 Contractors: 45/6=.5 6'KC c
City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked below.
(This is [, -an existing system [ ] new construCtion)
SYSTEM CONFORMITY (1-3):
(T.) "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
without discharging any pollutants into ground or surface waters.
2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the
current City Codes, but was installed according to the code in effect at the time of installation, and which
is operating satisfactorily by treating and disposing of the entire current sewage input without discharging
any pollutants into ground or surface waters.
3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any
system which may or may not meet all the location, design, and construction standards of the current City
Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand
between the distribution device and the limiting soil characteristics.
(The limiting soil characteristic has or [ ] has not been identified at this time. If the limiting soil
characteristic has not been ident fie , this classification may be subject to revision.)
TANK CONDITION (5-10): 5
erinspection indicates:
Punpout not needed at this time.
Solids accumulation in tanks indicates they should bepumped out this year to help prevent future problems.
7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible.
8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge.
9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each
tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pupped
out now.
10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation).
If tanks have not been pupped out within the last three years, they should be pumped out now.
DRAINFIELD CONDITION (11-14):
I
//
teld inspection indicates(:)
1Drainfield is dry, no surfacing evident.
Some evidence of surfacing, not critical yet.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately. Repairs must be completed within 90 days.
14 Drainfield extent and condition unknown.
LIMITING SITE FACTORS (slope,setbacks,etc.):
POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): 414.)
COMMENTS: _ -
— a . jt
--
Date of Inspe tion Septic Sy: em Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or certify that an existing system will continue to function
properly, but is merely an opinion of the adequacy of the system under current conditions based on the available
information.
This report must be kept on the premises with the system location and pumping records.
WHITE COPY/Inspectors File YELLOW COPY/Homeowner
----o
i-1:\\\\
. :*,„
,.....„, ,,,,
CITY of ORONO
,r,v;vi,_
11k �l4 Municipal Offices
M
,t ,,� ,. `�`` Street Address: Mailing Address:
iCEggOg' 2750 Kelley Parkway P.O. Box 66
/ Orono, MN 55356 Crystal Bay, MN 55323-0066
Owner: ] F1 'e. F. .Bre II Address: 4545 Watertown Rd.
Permit #'s: 6171 Dates: 6/14/94 Contractors: Hayes Exc.
(This is [v1 an existing system [ ] new construction) .
STEM COMPLIANCE (1-3) : 1
Code System: Meets or exceeds current City standards in all respects relating to design,
construction, and location. Appears to be operating properly.
2 Compliant System: Does not meet all current City standards for new construction, but in
most respects appears to be designed, located, and constructed in accordance with previous
codes and is functioning properly.
3 Non-Compliant System: System may or may not meet current City standards for design,
construction, or location, but is failing to properly treat and dispose of the current
input; and any system with less than three feet of vertical separation between the bottom
of the drainfield and the saturated soil level.
(The saturated soil level (!/1 has or [ ] has not been identified at this time. If the
saturated soil level has not been identified, this classification is subject to revision.)
TANK CONDITION (5-9) : 5
Pumpout not needed at this time.
6 Solids accumulation in tanks indicates they should be pumped out this year.
7 System is discharging to the surface. Tanks must be pumped out within 48 hours.
8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out
within three years, they should be pumped out and risers installed now.
9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks
have not been pumped out within three years, they should be pumped out now.
(During the last septic tank Maintenance Pumpout the tanks [ ] were or [ ] were not confirmed
to be watertight by the licensed pumping contractor. If the tanks were not confirmed to be
watertight, this classification is subject to revision.)
OD
CONDITION (11-14) : 11
�
C� Drainfield is dry, no surfacing evident.
12 Some evidence of surfacing, not critical yet. Repair is not required at this time.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface.
Contact the City Inspector immediately. Repair must be completed within 90 days.
14 Drainfield extent and condition unknown.
POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc. ) : low
COMMENTS:
- SJzo /9'7 1/ i_ _. _`. iTd . -
Date of Inspection S=.tic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a
transfer of property, this report does not guarantee that an existing system will continue to
function properly, but indicates the operation of the system under current conditions.
Telephone (612) 473-7357 • FAX 473-0510