Loading...
HomeMy WebLinkAbout2001 Certificate of Survey & Site Planc 2000 Westwood Professional Services, Inc. LEGAL DESCR/PT/ON.• Lot 4, Block 1, CARR/AGE HILL, according to the recorded plat thereof, Hennepin County, Minnesota. 1_ sEpT/c \ RE,q APPROX. FUTURE LOCATION I ` 48.80 N89058'51 "W �a 0 O O (0 o \\� v o -P �Ln , \moo 1 \edge of wetland 'L / 1 dreinag� and\___Z-X utility ea ement \'�,' \ IS89058'51"E) 48.80 \ v \ \ \ M55 °58'35 "I--32.9 -- 32.9 � I �� / 1 \10 OOQ j \ I NJ drainage and��� T W o utility easement 1 962 a II! A-5601716" P L=49.12 In R=50.00 1 r ' I i �� i Bearing are based on assumed data 0 Denotes iron monument set • Denotes iron monument found ®Westwood Professional Services, Inc. 104 Marty Drive, Suite 3 Buffalo, MN 55313 Phone: 612/682-2587 Fax: 612/682-2639 i I�Alternate Septic Sys em N I, '\ \,� 41�1f of 10 /D �� cD grovelless-trenc a and.----- W draina a \'� \ \ utility asement_ \ Naee I�I sb#42' �� \ 44' / t, OR Q -4e\ \W .-' \\ sb#44 sb#13 i--- o I 0.3 C� � • yR 1 \ /1 1 �j Pn ary Yep tic Sys tell, 416 If f 10 /D r9rv s trench i _ 2-1gallon pre- / cc septic tanks •h \ .. 200' buidling setback line � \ and utility easement t4 33 33 �O 33 1 33 drainage and utility_- GRAPHIC SCALE easement ��_,� 40 0 20 40 80 Milli I hereby certify#.t this survey was directsu and that I am a d wader the kof the State opXinp Dais 2/2'1/00 ane or under my Revlii= Surveyor 1/22/01 HOUSE AND DRIVEWAY 2/14/01 HOUSE AND DRIVEWAY 23002 ( IN FEET ) 1 inch = 40 ft. Crew. ss/JL Prepared for. Chwlma: sc Drawn: HCM Record Drawing by/daft 160 BUILDING ELEVA TIONS Top of foundation = 965.5± Lowest house floor = 955.5± Garage floor (upper)= 965.0± Garage floor (lower)= 955.0± *Elevations are approximate and may need to be adjusted in the field LEGEND Ow well ® soil boring Q percolation test x existing fence J existing deciduous tree existing coniferous tree existing elevation contour 92x4 existing spot elevation Fg--2—*4-1 proposed spot elevation ❑ Elevations relative and ossumed �d/ Bevations relative to U. S. G. S. 1929 N. G. V.D. Denotes proposed surface drainage Scott Winton 3420 Northome Raod Wayzata, Minnesota No tes. 1. Avoid compaction in septic area before, during and after construction 2. Trenches are to be installed parallel to the contours and the trench excavations are not to exceed a maximum depth of 24" inches below the existing ground surface. 3. Verify before dri/ling that no septic tanks or drainrields are within a 50 foot radius of proposed well location. (100 feet for shallow well) 4. Verify before construction that no shallow wells are within 100 feet, or deep wells within 50 feet of proposed septic tanks or drain field area. 5. To extend the life of septic system pump septic tanks o minimum of every 2 years 6. See attached sheets for additional construction detoils. 7. Soil classified as Hubbard loamy sand (HbO) 12-189 slooes, according to the U.S. Department of Agriculture soil Survey 8. Site plan prepared by or under the supervision of Bernie Miller- M. P. C.A. License No. 43 &7hq'Q ^[L, -d e o I�o o o �� I A S8S N�� e �o �o i s e e e i e HOUSE FOUNDATION y`3'�� not to scale �� 8 O 0 �1 0 �0 ,21 .0 4) �1 eo O s � R� � DETAIL e e 998 e e O e i NOTE: DIMENSIONS SHOWN ON THE DETII_ eTO THE EXTERIOR FOUNDATION BE VERIFIED PRIOR TO` CONSTRUC11ON e e e e ARE MEASURED h W a1_L AND SHOULD 0 ,o o 0 `.0 ?9 `. 0 I e etiry e e L J I Block CARRIAGE HIL kirono,, Date: 2/21/00 9 718 c t f. D WG job# 99%18 C ' 'cate of Survey Site Plan