HomeMy WebLinkAboutOnsite sewage treatment systems CITY of ORONO f Municipal Offices Street Address: Mailing Address: 1 ti 2750 Kelley Parkway P.0. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 To: The Current Owner of Address C f F0c-r,U City Ordinance requires that onsite sewage treatment systems in Orono be inspected on a periodic basis. The onsite sewage treatment system at the above address has been inspected and the following is known about the system. A sketch of the known components of the system is available for most properties at the Orono City Hall. Imminent Public Health Threat Yes No If yes, please contact the Onsite Systems Manager at 952-249-4626 within 10 days of receipt of this notice. The septic system must be brought into compliance within 90 days. Failure to do so will result in referral to the City Attorney for legal action. System Ide fied as Non-Compliant Yes No If yes, system must be brought into compliance by: December 31, 2007 December 31, 2010 Other Septic Tank(s) Pump out Needed Yes No The City recommends the septic tank(s) and/or lift tank be serviced and pumped out every three years. City records indicate the tank(s) were last pumped out on 1 t .21 -U S . The tank(s) should be cleaned through the manhole and not through the inspection pipes, this allows for proper cleaning. Comments: •kg • Inspector: Date of Inspection / 0 T Telephone(952)249-4600 • Fax(952)249-4616 www.ci.orono.mn.us o o 4„. , I _rs .k. __ CITY of ORONO '�(( O . E, Municipal Offices * ,c l! Y�i`• Gj Street Address: Mailing Address: ,,•t, E88 j ' 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 5323-0066 To Current Owner: Address: 4) )-o ' ' W i-`^-' tkc City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFORMITY (1-3): 3 1 "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and which is not failing or an imminent threat to public health or safety. 0"NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. TANK CONDITION(5-7): 7 Tank inspection indicates: CDPumpout not needed at this time. 6 Septic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years. Tank was last pumped 0..14,--1—c\-- ). Make sure septic tanks are pumped through manhole and not through white inspection pipes. This allows for the proper cleaning. Keep water softner and iron filter discharge out of septic system. 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If tanks have not been pumped out within the last three years,they should be pumped out now. INFIELD CONDITION(8-10): 8 Drainfield is dry,no surfacing evident. Some evidence of surfacing,not critical yet. 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately.Repairs must be completed within 90 days. COMMENTS: `�-sC�--(--,�:e.\ \S eNof- 0 IV civ \-,:i c__ c�\o..t_ b --1 N Z.,-.3) -2010 , V.2O --a Glr'', b4)1\77.::—___ Date of Inspection Matt Bolterman- Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion ofthe adequacy of the system under current conditions based on the available information. Telephone(952)249-4600 • Fax(952)249-4616 www.ci.orono.mn.us - e- _ CITY of ORONO •pa.„. � ,' . ' I ,�tipf Municipal offices ii41ll1 G ° Street Address: EggOg' 2750 Kelley Parkway Mailing Address: P.O. Box 66 Orono, MN 55356 ` Crystal Bay, MN 55323-0066 Owner: c .c) 0Q_.-``-r" v\/ y o. Address: L-11)-0 \--'cl- r-)-(s— City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFORMITY (1-3): 3 1 "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono Municipal 111 Code but does meet the three foot separation requirement,and which is not failing or an imminent threat to public health or safety. "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISIS which may or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. TANK CONDITION(5-10): C Tank inspection indicates: 5 Pumpout not needed at this time. Tank must be pumped out this year (city code requires tanks to be pumped out every 3 years. Tank was last pumped -16_ ) ), 7 Solids accumulation in tanks is at a critical a critical level. Tanks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. 9 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank at next pumpout. If tanks have not been pumped out within the last three years,they should be pumped out now. 10 Inspection pipe is located directly over tank baffle(does not give accurate measurement of solids accumulation). If tanks have not been pumped out within the last three years,they should be pumped out now. e.e.• I LD CONDITION(11-14): \ • .' eld is dry,no surfacing evident 12 Some evidence of surfacing,not critical yet • 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately.Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. COMMENTS: 5 -E5'y°r-- :5 r\b..- Co^1)1 ham- bvc -i-6 °,C(C 01— -3 66,1- .Sq°600-:Q,-, bey_<°,_., ' p o S Q-A 5 a,-�\ s---c0-,r-)--v� �_ 0 t-r-G . 0 -1-r k-nl'�c \ h s - Re���(t �� I)-31-1616 . J "' -oc-,ks r\0��- Sy C.c.() , \\—\L-O \ Pet-t---------2.rvv-r;1/4.-------- Date of Inspection Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other tiansfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. 0 0 CITY of ORONO • G�ti .� Municipal Offices Street Address: Mailing Address: \\9�tEggO� 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 June 12, 2000 Bob Wyatt 4220 Watertown Road Maple Plain, Mn 55359 Dear Mr. Wyatt: This letter is in regards to the damage to your septic system by Northern States Power Company(NSP) on or around December 20, 1999. The existing septic system is a non-compliant septic system due to the fact that the drainfield does not meet the required three (3) foot separation to the seasonally high watertable. A soil boring was conducted by Orono City staff to determine the depth to the watertable. Due to the fact that the septic system is non-compliant, the septic system will need to be replaced. Orono Municipal Code does not allow an existing non-compliant septic system to be repaired. This is found in Section 12.30, Subdivision 5, Letter C, Number 3: "Existing non-compliant systems shall be replaced by code systems whenever such classification is reasonably attainable. If a code system is not achievable due to soil, watertable, or lot limitations, the ISTS may be replaced or repaired such that it becomes a compliant system." The existing septic system cannot be repaired as per Orono Municipal Code. Orono Code requires that a"code" septic system be installed. A septic design submitted by S-P Testing appears to meet all the requirements of a "code" system required by Orono. The septic tanks will need to be pumped and inspected by Orono Staff. The tanks can be used if they are water tight and of the appropriate size. If the tanks do not meet both criteria, new tanks will need to be installed. Please contact me if there are any questions regarding this letter at(952) 249 -4600. R pec , V.614,// ris Pence On-Site Systems Manager Telephone(952)249-4600 • Fax(952)249-4616 www.ci.orono.mn.us CITY OF ORONO0 Municipal Offices (10:6; Ato.‘ Post Office Box 66 '_ Crystal Bay, MN 55323-00661 ON—SITE SEWAGE TREATMENT 411' 44 K.. INSPECTION REPORT k �sKo Owner: (?ob��4- iFl?CE- Address: it 12-0 ke4te 1OwA! Ad O Permit #'s: 5.118/ J?'l Dates:olc/23 'IId--Y-9/ Contractors:(i 6FPFER+ , e.7I,4y's cxe., City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is J".an existing system [ ] new construction) SYSTEM CONFORMITY (1-3): I "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic has or [ ] has not been identified at this time. If the limiting soil characteristic has not been identi ie , this classification may be subject to revision.) TANK CONDITION (5-10): b Tank inspection indicates: 5 Pumpout not needed at this time. Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped out now. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been pumped out within the last three years, they should be pumped out now. DRAINFIELD CONDITION (11-14): 1I Wield inspection indicates: Drainfietd is dry, no surfacing evident. Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (slope,setbacks,etc.): -- POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): /00 COMM•ENTS: Ow YP,'rtd,s Sim() Ji Bilis 045 B--7—?. . City 'J) 1(., „,y,,;. Ail Date of Iilispection Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the system location and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner At CITY OF ORONO 0 Municipal Offices 14; O Post Office Box 66 '-=- Crystal Bay, MN 55323-0066 \ l ON—SITE SEWAGE TREATMENT IA ' ^Ir1 INSPECTION REPORT '4 104)4(i,'a,HM;�1�40 4;4 kESo Owner: ' G G f Address: '(z70 Ella f ,& (&12-itiOel !f o&-4 (57,,q50 Permit #'s: 76 q Dates: /0 (2- 76 //'. 7 — ( 6Contractors: St( (ft V '� City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is X an existing system [ ] new construction) SYSTEM CONFORMITY (1-3): ,. 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic has or has not been identified at this time. If the limiting soil characteristic has not been identiie , this ssification may be subject to revision.) TANK CONDITION (5-10): 9 Tank inspection indicates: 5 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. (OP)(:4:, Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pooped out now. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been pumped out within the last three years, they should be pumped out now. DRAINFIELD CONDITION (11-14): /l 10 r field inspection indicates: � Drainfield is dry, no surfacing evident. Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (slope,setbacks,etc.): .._.-- POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): /0 COMMENTS: 5 /S -Cdl'17C�RGh/�tr / ` dy, • G.J (4 C`c d tiY %I s >! 11�2 Q�tJ )ra'l vl,("i ) 6.= 0. rJ✓� - 50ast1.tell n &lP. _4y6i44 4 ,; � Vu247ace/ &.y, /2-�I-XV7. /1 ~ v r- ?? -.s-' Date of Inspe6tion Sep is Sy'§tem Inspector Note: in the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the system location and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner '"-',0,(:).,--4 Oh ‘,,,, -, _ CITY of ORONO ,t, , ,s, 1vna , ,iptt,; ,--, �& Municipal Offices e*4 I �t 1', � - Street Address: Mailing Address: 'etrCEggO 2750 Kelley Parkway P.O. Box 66 . Orono, MN 55356 Crystal Bay, MN 55323-0066 Owner: knhec^t---T. 1r ft Address: 4220 Watertown Rd. Permit #'s: 4641 Dates: 10/12/76 Contractors: Sullivan (This is [ fs(an existing system [ ] new construction) . SYSTEM COMPLIANCE (1-3) : 3 1 Code System: Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. 2 Compliant System: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance with previous 0( codes and is functioning properly. Non-Compliant System: System may or may not meet current City standards for design, construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level. (The saturated soil level [ ✓] has or [ ] has not been identified at this time. If the saturated soil level has not been identified, this classification is subject to revision.) TANK CONDITION (5-9) : 9 5 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year. 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out within three years, they should be pumped out and risers installed now. aInspection pipe is located over tank baffle-can not measure solids accumulation. If tanks have not been pumped out within three years, they should be pumped out now. (During the last septic tank Maintenance Pumpout the tanks [ ] were or [ ] were not confirmed to be watertight by the licensed pumping contractor. If the tanks were not confirmed to be watertight, this classification is subject to revision.) DRAINFIELD CONDITION (11-14) : 11 (117 Drainfield is dry, no surfacing evident. 12 Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc. ) : medium COMMENTS: In order to confirm that your septic system meets Minnesota standards, soil borings were performed to verify a 3 foot separation between the drainfield and the seasonal water table. The separation is 0 feet and the system is non-compliant. Repair or replacement of the septic system is required by 12/31/2007. /jam', -/2 7 /9 7 _,.71_!/.61K I AK A �i A14l//-/ Date of Inspection Se. is System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicates the operation of the system under current conditions. Telephone (612) 473-7357 • FAX 473-0510 CITY OF ORONO 0 ' Y Municipal Offices O O Post Office Box 66 i<�_ Crystal Bay, MN 55323-0066 v:‘ '- " r ON—SITE SEWAGE TREATMENT ViliikINSPECTION REPORT kESHO�' Owner: Ri ff 4 S1 Address: 4/2700 Aidkle-15 /CQi. Permit #'s: 14‘4"/) / Dates: /0"/)—/6 Contractors: SIJ/A%/pY1, City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This iso an existing system [ ] new construction) SYSTEM CONFORMITY (1-3): 7 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input 6) without discharging any pollutants into ground or surface waters. "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic [ ] has orhas not been identified at this time. If the limiting soil characteristic has not been identified, this c assification may be subject to revision.) TANK CONDITION (5-10): In Tank inspection indicates: 5 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped out now. J_ 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been pumped out within the last three years, they should be pumped out now. DRAINFIELD CONDITION (11-14): ' t D field inspection indicates:/ 11 Drainfield is dry, no surfacing evident. Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (slope,setbacks,etc.): POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): //� ""'"/!y)\ COMM NTS: 1. ':i/ +c'Ea L. ' /1,S11'. 4!l 1i�91 G� 4< J PIT�v MA-) n f I. It ✓P y" '/ - " / � pr �s ______4E2,__ Jiff', i �y Date of Inspection Se! is S tem Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the system location and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner CITY OF ORONO Municipal Offices r(11?C0.‘ Post Office Box 66 Crystal Bay, MN 55323-0066 '� PA,r ON—SITE SEWAGE TREATMENT r `` INSPECTION REPORT kEsno� Owner: &b Tflllnl'yQ ___Address: 171O}X Aid4142/tAe—• Permit #'s: 7/ '--Dates: Contractors: 5011/1121,--- City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is D41. an existing system [ ] new construction) SYSTEM CONFORMITY (1-3): 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic [ ] has or has not been identified at this time. If the limiting soil characteristic has not been identified, this classification may be subject to revision.) TANK CONDITION (5-10): 5 TpNc inspection indicates: (y Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped out now. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been pumped out within the last three years, they should be pumped out now. DRAINFIELD CONDITION (11-14): 7 I Drainfield inspection indicates: 11 Drainfield is dry, no surfacing evident. Some evidence of surfacing, not critical yet. �/ , 13 rainfield is saturated and visibly dischargin ug ntreated effluent to the surface. Contact the City Inspector o inmqcij .. Repairs must pe Pomp-re-tea wit in 90 days. 14 Drainfie ent and condition unknown. LIMITING SITE FACTORS (slope,setbacks,etc.): POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): --a COMMENTS: Date of Inspection ptic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the system location and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner On the North Shore of Lake Minnetonka ON-SITE SEWAGE TREATMENT CITY INSPECTION REPORT OF POST OFFICE BOX 66 ORONO 1335 S. Brown Rd. Crystal Bay, MN 55323 '' r 473-7357 OWNER / 2L4r7L ✓I 4.1.47-# ADDRESS < 4Jahv-144-4 ICCr�. PERMIT NO.'S. 7b / DATES /0`/a-7Z CONTRACTORS .I4ZA --, City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is an existing system 0 new construction) 1 Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating properly. i2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, 1�� located, and constructed generally in accordance with previous codes.System appears to be functioning properly;no major upgrading of the system is required at this time. O 3 Does not meet current City standards in many respects relating to design,construction,or location.Appears to be operating adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at this time. O 4 System may or may not meet current City standards for design,construction or location, but is failing to properly treat and dispose of the current input,and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is creating a safety hazard, or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/ replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan must be submitted for review.Your contractor must obtain a permit before work is started. SYSTEM CONDITION ( m Checked items may require your action) Tank inspection indicates: Inspection pipe is located directly over tank baffle.(Does not ❑ Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks ❑ Solids accumulation in tanks indicates they should be pump- have not been pumped out within the last three years,they ed out this year to help prevent future problems. should be pumped out now. ❑ Solids accumulation in tanks is at a critical level. Tanks Drai field inspection indicates: should be pumped out as soon as possible. Drainfield is dry,no surfacing evident. ❑ System is discharging to surface. Tanks must be pumped 0 Some evidence of surfacing,not critical yet. within 48 hours to eliminate surface discharge. 0 Drainfield is saturated and visibly discharging untreated ❑ Inspection risers missing—tanks could not be inspected. effluent to the surface. This condition may require replace- Inspection risers (4"dia. pipe)must be installed in each tank ment or additions to drainfield. Contact the City Inspector at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days. the last three years,they should be pumped out now. 0 Drainfield extent and condition unknown. SITE CHARACTERISTICS: Limiting Site Factors Potential for System Failure Site Capabilities for ❑ Slope (depends on soil types,water Future Expansion ❑ Soil table,and system condition) 0 Adequate ❑ High water table ❑ Low 93-Fair ❑ Lot size 'Medium 0 Poor ❑ Lake,wetland,or stream 0 High 0 Inadequate ❑ Drainage 0 System is causing visible surface discharge. COMMENTS: Date of Inspection 'Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with system location and pumping records. WHITE COPY/Inspector's File GOLD COPY/Homeowner