Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Septic System Management Plan for Above Grade
UNIVERSITY OF MINNESOTA Septic System Management Plan for Above Grade Systems The goal of a septic system is to protect human health and the environment by properly treating wastewater before returning it to the environment. Your septic system is designed to kill harmful organisms and remove pollutants before the water is recycled back into our lakes, streams and groundwater. This management plan will identify the operation and maintenance activities necessary to ensure long- term performance of your septic system. Some of these activities must be performed by you, the homeowner. Other tasks must be performed by a licensed septic maintainer or service provider. However, it is YOUR responsibility to make sure all tasks get accomplished in a timely manner. The University of Minnesota's Septic System Owner's Guide contains additional tips and recommendations designed to extend the effective life of your system and save you money over time. Proper septic system design, installation, operation and maintenance means safe and clean water! Property Owner Matthew Nyquist Property Address 1125 Pine View Drive Property ID 2811823420007 System Designer Joseph J Olson Phone 763-498-8779 System Installer Phone Service Provider/Maintainer Phone Permitting Authority C 0F_ a‘y (ew A.shone SZ- -Z l— /f�j Permit# t'Date Inspected Keep this Management Plan with your Septic System Owner's Guide. The Septic System Owner's Guide includes a folder designed to hold maintenance records including pumping, inspection and evaluation reports. Ask your septic professional to also: • Attach permit information,designer drawings and as-builts of your system,if they are available. • Keep copies of all pumping records and other maintenance and repair invoices with this document. • Review this document with your maintenance professional at each visit; discuss any changes in product use,activities or water-use appliances. For a copy of the Septic System Owner's Guide,call 1-800-876-8636 or go to http://shop.extension.umn.edu/ http://septic.umn.edu Version 11/03/2010 - 1 - System stem Mana ement Plan UNIVERSITY p y g for Above Grade Systems OF MINNESOTA Your Septic System .Cleanout Manhole Inspection pipe_ rump TAnk __1111111 ,u o� pump—— ,>�• m:,� s* .�,. "y" Mould. Lateral Cleanout._ Cross-section of mound _ DRfnhuLan nseda 4 ��' Inspection pipe -"z �[oanryfU�: i 1 y. Topsad_ AI a a - San 4c' . d... Y s'. from punt[.mks ^." ['k�Ycrtkgs} r ,tfafura�,sdl olyntm?candchar..2 Septic System Specifics nSystem is subject to operating permit* System Type:Cy 011I 0w*0 V* System uses UV disinfection unit* (Based on MN Rules Chapter 7080.2200—2400) Type of advanced treatment unit *Additional Management Plan required Dwelling Type Well Construction Number of bedrooms: 5 Well depth(ft): Not in System capacity/design flow(gpd): 750 n Cased well Casing depth: Anticipated average daily flow(gpd): 750 n Other(specify): Comments Distance from septic(ft): Business? What type? Is the well on the design drawing?0Y ® N Septic Tank One tank Tank volume: gallons 7 Pump Tank 1300 gallons Does tank have two compartments?OY ON ❑ Effluent Pump make/model: Two tanks Tank volume: 1300 gallons Pump capacity GPM ❑ Tank is constructed of TDH Feet of head Effluent Screen type: ❑ Alarm location Soil Treatment Area (STA) Mound/At-Grade area(width x length): 48 ft x 91 ft Cleanouts or inspection ports Rock bed size(width x length): 10 ft x 63 ft Surface water diversions Location of additional STA: On drawing Additional STA not available -2 - UNIVERSITY Septic System Management Plan for Above Grade Systems OF MINNESOTA Homeowner Management Tasks These operation and maintenance activities are your responsibility. Use the chart on page 6 to track your activities. Identify the service intervals recommended by your system designer and your local government. The tank assessment for your system will be the shortest interval of these three intervals. Your pumper/maintainer will determine if your tank needs to be pumped. System Designer: check every 0 months My tank needs to be checked Local Government: check every 36 months every 24 months State Requirement: check every 36 months Seasonally or several times per year • Leaks. Check(listen, look)for leaks in toilets and dripping faucets. Repair leaks promptly. • Surfacing sewage. Regularly check for wet or spongy soil around your soil treatment area. If surfaced sewage or strong odors are not corrected by pumping the tank or fixing broken caps, call your service professional. Untreated sewage may make humans and animals sick. • Alarms. Alarms signal when there is a problem; contact your maintainer any time the alarm signals. • Lint filter. If you have a lint filter, check for lint buildup and clean when necessary. Consider adding one after washing machine. • Effluent screen. If you do not have one, consider having one added the next time the tank is cleaned. Annually • Water usage rate. A water meter can be used to monitor your average daily water use. Compare your water usage rate to the design flow of your system (listed on the next page). Contact your septic professional if your average daily flow over the course of a month exceeds 70% of the design flow for your system. • Caps. Make sure that all caps and lids are intact and in place. Inspect for damaged caps at least every fall. Fix or replace damaged caps before winter to help prevent freezing issues. • Water conditioning devices. See Page 5 for a list of devices. When possible, program the recharge frequency based on water demand (gallons) rather than time (days). Recharging too frequently may negatively impact your septic system. • Review your water usage rate. Review the Water Use Appliance chart on Page 5. Discuss any major changes with your pumper/maintainer. During each visit by a pumper/maintainer • Ask if your pumper/maintainer is licensed in Minnesota. • Make sure that your pumper/maintainer services the tank through the manhole. (NOT though a 4" or 6"diameter inspection port.) • Ask your pumper/maintainer to accomplish the tasks listed on the Professional Tasks on Page 4. - 3 - UNIVERSITY Septic System Management Plan for Above Grade Systems tea, OF MINNESOTA `L Professional Management Tasks These are the operation and maintenance activities that a pumper/maintainer performs to help ensure long-term performance of your system. Professionals should refer to the O/M Manual for detailed checklists for tanks,pumps, alarms and other components. Call 800-322-8642 for more details. • Written record provided to homeowner after each visit. Plumbing/Source of Wastewater • Review the Water Use Appliance Chart on Page 5 with homeowner. Discuss any changes in water use and the impact those changes may have on the septic system. • Review water usage rates(if available)with homeowner. Septic Tank/Pump Tanks • Manhole lid. A riser is recommended if the lid is not accessible from the ground surface.Insulate the riser cover for frost protection. • Liquid level. Check to make sure the tank is not leaking. The liquid level should be level with the bottom of the outlet pipe. (If the water level is below the bottom of the outlet pipe,the tank may not be watertight. If the water level is higher than the bottom of the outlet pipe of the tank, the effluent screen may need cleaning,or there may be ponding in the drainfield.) • Inspection pipes.Replace damaged caps. • Baffles. Check to make sure they are in place and attached, and that inlet/outlet baffles are clear of buildup or obstructions. • Effluent screen. Check to make sure it is in place; clean per manufacturer recommendation. Recommend retrofitted installation if one is not present. • Alarm. Verify that the alarm works. • Scum and sludge. Measure scum and sludge in each compartment of each septic and pump tank, pump if needed. Pump • Pump and controls. Check to make sure the pump and controls are operating correctly. • Pump vault. Check to make sure it is in place; clean per manufacturer recommendations. • Alarm.Verify that the alarm works. • Drainback. Check to make sure it is operating properly. • Event counter or run time. Check to see if there is an event counter or run time log for the pump. If there is one, calculate the water usage rate and compare to the anticipated average daily flow listed on Page 2. Soil Treatment Area • Inspection pipes.Check to make sure they are properly capped.Replace caps that are damaged. • Surfacing of effluent. Check for surfaced effluent or other signs of problems. • Lateral flushing. Check lateral distribution; if cleanouts exist,flush and clean as needed. • Ponding. Check for ponding. Excessive ponding in at-grade and mound beds indicates problems. All other components—inspect as listed here: -4- r � UNIVERSITY Septic System Management Plan for Above Grade Systems OF MINNESOTA Water-Use Appliances and Equipment in the Home Appliance Impacts on System Management Tips • Uses additional water. • Use of a garbage disposal is not recommended. • Adds solids to the tank. • Minimize garbage disposal use.Compost instead. Garbage disposal • Finely-ground solids may not settle. • To prevent solids from exiting the tank,have your Unsettled solids can exit the tank tank pumped more frequently. and enter the soil treatment area. • Add an effluent screen to your tank. • Washing several loads on one day • Choose a front-loader or water-saving top-loader, uses a lot of water and may overload these units use less water than older models. your system. • Limit the addition of extra solids to your tank by • Overloading your system may using a liquid or easily biodegradable detergents. Washing machine prevent solids from settling out in • Install a ling filter after the washer and an effluent the tank.Unsettled solids can exit screen on your tank. the tank and enter the soil treatment • Wash only full loads. area. • Limit use of bleach-based detergents. • Think even—spread your laundry loads throughout the week. • The rapid speed of water entering • Install an effluent screen in the septic tank to 2"d floor laundry the tank may reduce performance. prevent the release of excessive solids to the soil treatment area. • Be sure that you have adequate tank capacity. • Powdered and/or high-phosphorus • Use gel detergents. Powdered detergents may add detergents can negatively impact the solids to the tank. Dishwasher performance of your tank and soil • Use detergents that are low or no-phosphorus. treatment area. • Wash only full loads. • New models promote"no scraping". • Scrape your dishes anyways to keep undigested They have a garbage disposal inside. solids out of your septic system. • Finely-ground solids may not settle. • Expand septic tank capacity by a factor of 1.5. Grinder pump(in Unsettled solids can exit the tank • Include pump monitoring in your maintenance home) and enter the soil treatment area. schedule to ensure that it is working properly. • Add an effluent screen. • Large volume of water may • Avoid using other water-use appliances at the Large bathtub overload your system. same time.For example,don't wash clothes and (whirlpool) • Heavy use of bath oils and soaps can take a bath at the same time. impact biological activity in your • Use oils,soaps,and cleaners in the bath or shower tank and soil treatment area. sparingly. Clean Water Uses Impacts on System Management Tips High-efficiency • Drip may result in frozen pipes • Re-route water into a sump pump or directly out furnace during cold weather. of the house.Do not route furnace recharge to your septic system. • Salt in recharge water may affect • These sources produce water that is not sewage Water softener system performance. and should not go into your septic system. Iron filter • Recharge water may hydraulically • Reroute water from these sources to another Reverse osmosis overload the system. outlet,such as a dry well,draintile or old drainfield. • Water from these sources will likely • When replacing consider using a demand-based Surface drainage overload the system. recharge vs.a time-based recharge. Footing drains • Check valves to ensure proper operation;have unit serviced per manufacturer directions - 5 - Septic System Management Plan UNIVERSITY tail for Above Grade Systems OF MINNESOTA ` Maintenance Log Track maintenance activities here for easy reference. See list of management tasks on pages 3 and 4. Activity Date accomplished Check frequently: Leaks: check for plumbing leaks Soil treatment area check for surfacing Lint filter: check,clean if needed Effluent screen: if owner-maintained Check annually: Water usage rate(monitor frequency ) Caps: inspect,replace if needed Water use appliances—review use Other: Notes: Mitigation/corrective action plan: "As the owner of this SSTS, I understand it is my responsibility to properly operate and maintain the sewage treatment system on this property, utilizing the Management Plan. If requirements in this Management Plan are not met, I will promptly notify the permitting authority and take necessary corrective actions. If I have a new system, I agree to'adequately protect the reserve area for future use as a soil treatment system." 40 0 j Property Owner Signature: At ;I '� Date LO 1-SI 4Management Plan Prepared By OSe• J olso• V Certification# 1255 Permitting Authority: C;l - Occi\J4J - c (-.4_....AAKL........:%'12;2, ©2010 Regents of the University of Minnesota. All rights reserved. The University of Minnesota is an equal opportunity educator and employer. This material is available in alternative formats upon request Contact the Water Resources Center,612-624-9282. The Onsite Sewage Treatment Program is delivered by the University of Minnesota Extension Service and the University of Minnesota Water Resources Center. - 6-