Loading...
HomeMy WebLinkAbout2015-00416 - mechanical CITY OF ORONO 2750 KELLEY PARKWAY * 20 1 5 - 0 0 4 1 6 DATE ISSUED: 04/15/2015 ORONO,MN 55356- 952 249-4600 FAX: 952 249-4616 ADDRESS 3445 WATERTOWN RD PIN 32-118-23-43-0009 LEGAL DESC UNPLATTED 32 118 23 LOT 000 BLOCK 000 PERMIT TYPE MECHANICAL(>$500) PROPERTY TYPE RESIDENTIAL CONSTRUCTION TYPE FIXTURES-MULTIPLE VALUATION $ 48,000.00 NOTE: GEOTHERMAL 3 HEATING SYSTEMS,3 COOLING SYSTEMS, 1 KITCHEN EXHAUST,4 BATH EXHAUSTS APPLICANT MECHANICAL 600.00 STATE SURCHARGE MECH(VALUATION) 24.00 MASSMANN,GEOTHERMAL&MECH TOTAL 624.00 27944 96TH STREET Payment(s) ZIMMERMAN,MN 55398 CHECK 4284 624.00 (763)416-5066 OWNER Gordon James P O BOX 306 MAPLE PLAIN,MN 55359- AGREEMENT AND SWORN STATEMENT The work for which this permit is issued shall be performed according to the approved plans and specifications,applicable City approvals,and the State Building Code. This permit is for only the work described and does not grant permission for additional or related work which requires separate permits. All provisions of laws and ordinances governing this type of work shall be compied with whether or not specified herein.This permit will expire and become null and void if construction authorized is not commenced within 180 days of the date of issuance,or if construction is suspended for a period of 180 days at any time after work has commenced. The applicant is responsible for assuring all required inspections are requested in conformance with the State Building Code.This permit may be revoked at any time for due cause.thid I'M4 Applicant Permitee Signature Date Issued By Signature Date City of Orono FOR CITY USE ONLY P.O.Box 66 Date Received:"��j,..t3—IS Permit# 90/,'g— L' t - 2750 Kelley Parkway �.�n` Crystal Bay,MN 55323 Approved By: Amount$: Phone(952)249-4600 Fax(952)249-4616 c1c Y p CITY OF ORONO—MECHANICAL PERMIT kES N O� (All Commercial permits must be approved by the Building Official or Inspector and/or Fire Marshall) GENERAL INFORMATION I. You may apply for mechanical permits by mail or in person at the City offices. Applications will be reviewed and a permit will be issued within two working days. 2. Permit cards will be sent by return mail after a review is completed. PERMITS ARE NOT VALID UNTIL YOU RECEIVE A PERMIT. WORK MUST NOT BEGIN UNTIL THE PERMIT CARD IS POSTED ON THE JOB SITE. 3. Mechanical Designs—Complete calculations,details and specifications are required for each heating,ventilation,humidification-dehumidification,and air conditioning installation including heat loss/heat gain calculation,design temperatures,equipment ratings and identification as to type,manufacturer and model. Data shall be presented on form provided. 4. When any new construction or remodeling is involved,a separate building permit must be obtained. 5. All work must be done in accordance with the Uniform Mechanical Code/State Building Code requirements. 6. All work must be inspected(rough-in and final). Call(952)249-4600. (24-48 hour notice required) 7. House Heating Test Record must be submitted before final. TYPE OF PERMIT Check All That Apply) Residential ❑Commercial(Approval Required) [ New ❑ Additional ❑Repairs ❑Replace Job Site/Owner Informaation: Site Address: Owner. Uorl n,'�a mes Uru Mailing Address: C� � City:' -PAC \ Zip: Home Phone: Alternate Phone:" Contractor Information: IC cj Contractor:M Wier;��nt,act Person: Address: �_�I r C-'-C ate Bond#: City: ::b %-n)MP Yff)jM 1ZipM. Y\3 Expiration Date: Phone: IU9) _���_ U� Alternate Phone: Insurance—Current: �( 1 Note: All Geothermal Systems will now require a Site Plan&Review by our Building Official. IS THIS GEOTHERMAL? X Yes ❑No HEATING SYSTEMS Quantity: 1f Make: Y 'C.C' UVW-oi Model: AS 16q oU ��.�`?�OLA N 09 r) XV/a6Cj Fuel: "il hRt/ � &,11,9 Flue Size: Obyt�— W Input BTUs: 1/y, y gl 0 -Q / 6 0 Output BTUs: IteJ CD° Y V 'O<S0 96,z/6') CFM: J,t,00 /UDS_ /I GOD COOLING SYSTEMS Quantity: i Make: rv� Q S A 1�V� Model: Tons: H. Power FIREPLACES ❑ Gas Factory Fireplace Brand Name: ❑ Wood Burning Fireplace ❑ Wood Stove Model No.: ❑ Wood Stove with Flue/Masonry VENTILATION i ��M No. Kitchen Exhaust / duct recirculating _/py cfm [� No. � Bath Exhaust(must have duct outside) 9D cfm ❑ No. Other Fans: Locations cfm FUEL STORAGE (Mast be approved by Fire Marshall if proposing to abandon tank in place.) Installation ❑ Removal Fuel Oil: gallons ❑ Underground ❑Inside ❑Outside LP Gas: gallons Other: GAS LINE ONLY ❑ Outdoor Grill ❑ Other/List What&Where: 2 PERMIT FEE CALCULATION(S) BASED OFF - 2002 STATE STATUE ❑ Yes,this section applies The replacement of a Residential fixture or appliance that meets all three of the following requirements: 1. Does not require modification to electrical or gas service. 2. Has a total cost of$500.00 or less;excluding the cost of the fixture or appliance: and 3. Is improved, installed or replaced by the homeowner or licensed contractor. Skip next section,if this applies; Cost of Permit $ 15.00 State Surcharge $ 5.00 Mail-In Fee(If Applicable) $ 2.00 Total Permit Fee $ PIP =`HERMIT FEE CALCULATION(S)—JOBS OVER$500.00 If above does not apply;follow guidelines below: 1. CONTRACT PRICE * is 1.25%of contract price with a(Minimum Fee of$50.00) 79,CVO X .0 125$ 4600,C70 contract price) (minimum$50.00) 2. STATE SURCHARGE 76'D x .0005 $ 7'i O Lo (contract price) 3. POSTAGE&HANDLING(Only on Mail-In Applications) $ 2.00 4. TOTAL PERMIT FEE(Add Lines 1-3 Above) $ `pzt 00 ■ * CONTRACT PRICE or JOB COST means the actual or estimated dollar amount charged for the permitted work including materials, labor,profit,and other fixed costs. It is the amount to be charged to the customer for the work done. If any material, equipment, labor or installations are furnished by the owner, tenant or any other party, the reasonable market value of such items must be added to the estimated cost or contract price for permit fee purposes. In the event that there is a dispute on the amount of the job cost, the City may request the submission of a signed copy of the actual contract. MECHANICAL PERMIT APPLICATION AGREEMENT _ The undersigned hereby applies to the City for issuance of a Mechanical Permit, agrees to do all work in strict accordance with the ordinances of the City and the regulations of the State of Minnesota, and certifies that all statements made on this application are complete, true and correct. Applicant's Signature: Date: 'Abo U0 3 0 Power Poll E,W Surveyor's Certi- ice_ ______________---------_ -------- 101 �\ / SURVEY FOR :Gordon James ) -007Vt j7 19184 DESCRIBED AS--:------------_- --- o�1 D_ii�" -------- -Marker i Sec 32, Township 118, Range 23 --------------- That ---------- .� 10186 "t q That port of the W._L59J_fsst_nL Sha___ _ie}� ; power Pole E,W �'@-aL_ 'aD4 3 Power Pole Ns,E,W E 1677.7 feet of the SE 1/4 Lying S _ _ / / of the Road _ --- _ - - - _ _ _ _ sat Fenne arker FND IP 16}G--- _ Note: Legal Desc. From County �i / _ N 1020.1 / / /� - 1020. Rock Const. y( Tax Description v[`y, ________________ _�If)9$____ / / ______ _ _ 1 Ent. INSTALL SILT FENCE&ROCK CONSTRUCTION ENTRAN_C_E _I-J j �- SILT FENCE MUST ALSO BE INSTA_LLEO_ARL- OUND-ALI / ^ STOCK PILES ------ rw_x\-11 _- I___--J 1 2. --- ________________ -- --�-' - --__-- O( ' x I �� _ ------------ r LOT SQ:"FOOTAGESeptpt I ic �g-3©-- I FENCE `' 61,,.5 Z 1---- TREE ILI 15&16' �91_ --- PROPOSED BUILDINGS SQ. FOOTAGE v ia31 s hExietin9 1 i _ A}0 INCLUDES ALL OF HOUSE = 6,068 - w--5-4'-a L ROPOSED BUILDING COVERAGE =9.8 o I _J - --- _-_-__ -L--- ' T'J O Ma ' -- r 3t _ Prod -�on , Proposed e ' I J y I • I_-- I-_ t3 10 .3--- / 19" r - 3:1 ° 03 _. - _� 0 i Slope 141 � �1O.,M T 40 W r B NAI ( 38.5 _1 +) Existing 10 .4 65.00 - ---- ---oma 44._00 036 BM: I ^ Home 1037. O 1 3. 13.50 0 040. 0 7.9 Z 30. 010.50 1037. 54.00 .70, O --� d/I r m 18.00Z 10�-44-------- _ v) 00 - m r•'7 031_ 'Rombld Garage 1p Brush nd Buckthorn � 9'pcw dA I h to be Removed M 2.0 I 039. 32.00 b3. 034. B. 32.00 Power P e N 6 1 e 040. Sport Court n h Guy ee 10 Below 32.00 1¢. 1 9.7 --------- , 10 9i9r -1-- - -----' ' ' SS.T a-- Proposed well EPs 9 37 7f ool 1 3 L L3'Existing P ti Existing Shed �N MIN. SETBACK REQUIREMENTS Front-50 House Side -30 Q I Rear -50 Gorage_Side -30 L ---_-- _ P - - - - - - - I - PROPOSED ELEVATIONS - �, I \ '-----T ------------ I j --- Top of Foundation =1041.0 Septic Garage Floor =1040.6 Basement Floor =1032.3 Aprox. Sewer Service =Septic I SCALE: 1 inch 30 feet Proposed Elev. = C_7 L---- ----- ----- Existing Elev. _ _ Drainage Directions- --- _-_-_----------159 70 °13'53"E 113L4 ---- Denotes Offset Stake = • I HEREBY CERTIFY THAT THIS IS A TRUE AND CORRECT REPRESENTATION HEDL llND OF THE BOUNDARIES OF THE ABOVE DESCRIBED PROPERTY AS SURVEYED BY ME OR UNDER MY DIRECT SUPERVISION AND DOES NOT PURPORT TO JOB NO: PLANNING 6NGIN66RING SURV6riNG SHOW IMPROVEMENTS OR ENCROACHMENTS, EXCEPT AS SHOWN. 14R-175 2005 Pin Oak Drive Eagan, MN 55122 DATE 2 /-24/-?5 CAD FILE: Phone: (651)405-6600 Y D. LINDGREN, D SURVEYOR Fax : (651) 405-6606 MINNESOTA LICENSE NUMBER 14376 Misc 14 Load Short Form Job: 1 Date: Dec 06,2014 MA_SSM_AN_N Entire House By: 6fOl„FF Mid 8 MfCiNiC41. Massmann Geothermal 27944 96th St NW,Zimmerman,MN 55398 Phone:763-389-0376 Fax.763-389-0386 Email:jason@massmanngeothermal.com Web:wwwmassmanngeothermal.com Project Information For: Gordon James, McPherson/Model Orono, MN Design Information Htg Clg Infiltration Outside db(F) -22 97 Method Simplified Inside db (F) 72 75 Construction quality Semi-tight Design TD (F) 94 22 Fireplaces 0 Daily range - M Inside humidity(%) 35 50 Moisture difference (gr/Ib) 41 50 HEATING EQUIPMENT COOLING EQUIPMENT Make Enertech Manufacturing LLC. Make Enertech Manufacturing LLC. Trade GEOCOMFORT Trade GEOCOMFORT Model GT060 Cond GT060 AHRI ref 3000398 Coil AH R I ref 3000398 Efficiency 3.29 COP Efficiency 19.53 EER Heating input 13.5 kW Sensible cooling 48046 Btuh Heating output 46178 Btuh Latent cooling 20591 Btuh Temperature rise 28 'F Total cooling 68637 Btuh Actual air flow 1566 cfm Actual air flow 1566 cfm Air flow factor 0.017 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.93 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) LL Stor Zone p 1088 3050 0 50 0 ML Zone p 2544 44754 24479 739 1108 Garage Zone p 1108 20584 0 340 0 Sport Zone p 1472 14582 7843 241 355 LL Zone p 2544 11832 3454 195 156 Entire House d 8756 94801 33413 1566 1566 Other equip loads 18385 0 Equip. @ 1.02 RSM 34081 Latent cooling 2345 TOTALS 8756 113186 36427 1 1566 1566 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. Wrl htsoft 2014-Dec-0609:30:47 9 Right-Suite®Universal 2013 13.0.11 RS000282 Page 1 Projectl.rup Calc=MA Front Door faces: N Project Summa Job: MA$SMANN � � Date: Dec 06,2014 t o,FaM<, ME aA. 4 Entire House By: Massmann Geothermal 27944 96th St NW,Zimmerman,MN 55398 Phone:763-389-0376 Fax:763-389-0386 Email:jason@massmanngeolhermal.com Web:www.massmanngeothermal.com Project Information For: Gordon James, McPherson/Model Orono, MN Notes: Design Information Weather: Minneapolis-St. Paul, MN, US Winter Design Conditions Summer Design Conditions Outside db -22 1= Outside db 97 'F Inside db 72 1= Inside db 75 'F Design TD 94 1= Design TD 22 'F Daily range M Relative humidity 50 % Moisture difference 50 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 94801 Btuh Structure 33413 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent (164 cfm) 8249 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 10135 Btuh Equipment load 113186 Btuh Use manufacturer's data n Rate/swing multiplier 1.02 Infiltration Equipment sensible load 34081 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2345 Btuh Ducts 0 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft') 8756 6560 Equipment latent load 2345 Btuh Volume(ft') 43860 32800 Air changes/hour 0.25 0.13 Equipment total load 36427 Btuh Equiv.AVF (cfm) 183 71 Req. total capacity at 0.70 SHR 4.1 ton Heating Equipment Summary Cooling Equipment Summary Make Enertech Manufacturing LLC. Make Enertech Manufacturing LLC. Trade GEOCOMFORT Trade GEOCOMFORT Model GT060 Cond GT060 AHRI ref 3000398 Coil AH R I ref 3000398 Efficiency 3.29 COP Efficiency 19.53 EER Heating input 13.5 kW Sensible cooling 48046 Btuh Heating output 46178 Btuh Latent cooling 20591 Btuh Temperature rise 28 'F Total cooling 68637 Btuh Actual air flow 1566 cfm Actual air flow 1566 cfm Air flow factor 0.017 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.93 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. htsoft 2014-Dec-0609:30:47 WI1 9 Right-Suite®Universal 2013 13.0.11 RS000282 Page 1 /4C0'. Projectl.rup Calc=MJ8 Front Door faces: N Load Multizone Summary Report Job: t MASSMANN p Date: Dec 06,2014 GEOIMEP NAI i MECYAMICAI By: Massmann Geothermal 27944 96th St NW,Zimmerman,MN 55398 Phone:763-389-0376 Fax:763-389-0386 Email:jason@massmanngeothermal.com Web:www.massmanngeothermal.com Infiltration Summary Heating Cooling ZONE NAME Volume ACH AVF HTM Volume ACH AVF HTM ft' cfm Btuh/ft' ft' cfm Btuh/ft' LL Stor Zone 1088 0.20 4 5.3 0 0 0 0 ML Zone 22896 0.26 98 5.3 22896 0.13 48 0.6 Garage Zone 9972 0.20 34 5.3 0 0 0 0 Sport Zone 7360 0.30 36 5.3 7360 0.14 18 0.6 LL Zone 2544 0.26 11 5.3 2544 0.13 5 0.6 Entire House 43860 0.25 183 5.3 32800 0.13 71 0.6 • • and AVF Summary ROOM NAME Area Htg load Clg load Htg AVF C1gAVF ft' Btuh Btuh cfm cfm LL Storage 1088 3050 0 50 0 LL Stor Zone 1088 3050 0 50 0 Bedroom 1 208 4835 2432 80 110 Main Bath 81 1793 522 30 24 Bedroom 2 195 4913 2194 81 99 Den 165 3260 1692 54 77 Living 361 5714 3569 94 162 Foyer 234 5346 3055 88 138 Dining/Kitchen 322 5016 3287 83 149 Laundry 88 2122 1182 35 54 Garage Entry 160 2993 1555 49 70 Pantry 30 62 32 1 1 Mudroom 78 161 161 3 7 Master Bed 262 4997 2878 83 130 Master Closet 84 174 89 3 4 Master Bath 196 3202 1746 53 79 Main Hall 80 165 85 3 4 ML Zone 2544 44754 24479 739 1108 Garage 1108 20584 0 340 0 Garage Zone 1108 20584 0 340 0 Sport Court 736 3094 901 51 41 Open To Below 736 11487 6942 190 314 Sport Zone 1472 14582 7843 241 355 LL Living 1540 4684 1622 77 73 Mech Room 436 2413 249 40 11 LL Stairs 126 794 22 13 1 LL Bath 48 359 28 6 1 WIC 3 36 179 17 3 1 WIC 4 24 179 14 3 1 Bedroom 3 165 1366 743 23 34 Bedroom 4 169 1859 759 31 34 LL Zone 2544 11832 3454 195 156 wri htsoft' 2014-Dec-06 09:30:47 �. g Right-Suite®Universal 2013 13.0.11 RS000282 Page 1 /'C*� Projectl.rup Calc=MJ8 Front Door faces: N Entire House 8756 94801 33413 1566 1566 2014-Dec-06 09:30:47 L " W CIh tSOft`9 Right-Suite®Universal 2013 13.0.11 RSW0282 Page 2+�^ Projectl.rup Calc=MJ8 Front Door faces: N DATE TIME bkF ORONO CALLED IN INSPECTIOPERMIT ON NOT 1C �O/I f SCHEDULED U[ �'t COMPLETED ADDRESS OWNER TELEPHONE NO.A 3.31_ 3- CONTRACTOR DESCRIPTION A <� — t~al ❑ FOOTING [IDEMO-FINAL [3SEPTIC FINAL Q ❑ POURED WALL ❑ PLUMBING RI ❑ EXCAV/GRADING/FILLING y ❑ FOUNDATION WATERPROOF ❑ PLUMBING FNAL ❑ TREE REMOVAL Z ❑ RADON SLAB MECHANICAL RI SITE INSPECTION Q ❑ FRAMING CHANICAL FINAL ❑ PROGRESS ❑ INSULATION ❑ WOOD BURNER/FIREPLACE ❑ COMPLAINT Q ❑ FINAL ❑ WATER HOOK-UP ❑ FOLLOW-UP W ❑ AS BUILT-SURVEY ❑ SEW HOOK-UP ❑ HARD COVER REMOVAL v ❑ DEMO-SITE ❑ SE INSTALL ❑ FOUNDATION/REMOVAL 2 OWNERlCONTRACTOR TO MEET YOU: ES—NO COMMENTS: W cc 4 W cc Q ` 2 W J LU,, Y:EBRKSATISFACTORPROCEED 0 PROJECT COMPLETE W 0 CORRECT WORK&PROCEED 0 ISSUE CERTIFICATE OF OCCUPANCY 0 CORRECT WORK,CALL FOR REINSPECTION TEMPORARY V BEFORE COVERING PERMANENT 0 CORRECT UNSAFE CONDITION WITHIN HOURS. 0 PHOTOTAKEN INSPECTOR WILL RETURN 0 STOP ORDER POSTED.CALL INSPECTOR 0 CITATION ISSUED 0 INSPECTION REQUIRED.CALL TO ARRANGE ACCESS. Call for the next inspection 24 hours in advance. (952) 249-4600 OwnerfContractor on site: Inspector. t� White CopyAnapectoes File Canary Copy/Site Notice 1(5 .;, DTE VIAE CITY OF ORONO CALLEDIN INSPECTION NQTICESCHEDULED ,S- ./S l0•" PERMIT NO. -6 'y Co LET D ADDRESS OWNER TELE ONE NO. 'O3 CONTRACTOR DESCRIPTIO ?4V W ❑ FOOTING ❑ DEMO-FINAL ❑ SEPTIC FINAL Q ❑ POURED WALL [:1 PLUMBING RI ❑ EXCAV/GRADING/FILLING H ❑ FOUNDATION WATERPROOF ❑ PLUMBING FINAL ❑ TREE REMOVAL Z ❑ RADON SLAB d2 KMCHANICAL RI G,4 ❑ SITE INSPECTION Q ❑ FRAMING ANICAL FINAL ❑ PROGRESS ❑ INSULATION ❑ WOOD BURNER/FIREPLACE ❑ COMPLAINT Q ❑ FINAL ❑ WATER HOOK-UP ❑ FOLLOW-UP ❑ AS BUILT-SURVEY ❑ SEWER HOOK-UP ❑ HARD COVER REMOVAL zt v ❑ DEMO-SITE ❑ SEPTIC INSTALL ❑ FOUNDATION/REMOVAL OWNERICONTRACTOR TO MEET YOU:_YES_NO COMMENTS: Cc 0 uc,f wvrK 50, J W QC Q Cc �i�!•Ski, S¢4 �i•s� .� o�..�C S ' W J d W ❑WORK SATISFACTORY:PROCEED O PROJECT COMPLETE W RRECT WORK&PROCEED ❑ISSUE CERTIFICATE OF OCCUPANCY ❑CORRECT WORK,CALL FOR REINSPECTION TEMPORARY BEFORE COVERING PERMANENT ❑CORRECT UNSAFE CONDITION WITHIN HOURS. p PHOTOTAKEN INSPECTOR WILL RETURN ❑STOP ORDER POSTED.CALL INSPECTOR CITATION ISSUED ❑INSPECTION REQUIRED.CALL TO ARRANGE ACCESS. Call for the xt inspection 244 hours in advance. (952) 249-4600 Owner tractor on si -�,` Inspector. White CopylInspector's File Canary Copy/Site Notice �/DATE TIM CITY OF ORONO CALLED IN 7 2 4 S INSPECTION NOTIC 0j SCHEDULED 7-�3/S �• PERMIT NO.��� "� COMPLETED ADDRESS 3 s G' - OWNER TFI.EPAD E 70 CONTRACTOR DESCRIPTION W ❑ FOOTING ❑ DEMO-FINAL ❑ SEPTIC FINAL Q ❑ POURED WALL ❑ PLUMBING RI ❑ EXCAV/GRADING/FILLING y ❑ FOUNDATION WATERPROOF ❑ PLU NG FINAL ❑ TREE REMOVAL Z ❑ RADON SLAB ❑ CHANICAL RI ❑ SITE INSPECTION Q ❑ FRAMING CHANICAL FINAL ❑ RATED WALLS ❑ INSULATION WOOD BURNER/FIREPLACE ❑ COMPLAINT Q ❑ FINAL ❑ WATER HOOK-UP ❑ FOLLOW-UP ❑ AS BUILT-SURVEY ❑ SEWER HOOK-UP ❑ FOUNDATION/REMOVAL ZU v ❑ DEMO-SITE ❑ SEPTIC INSTALL 2 OWNER=NTRACTOR TO MEET YOU:_YES_NO y COMMENTS- cc 0 W cc Q 12 2 W Z W cc J d W ❑WORK SATISFACTORY PROCEED OJECT COMPLETE W ❑CORRECT WORK&PROCEED ❑ ISSUE CERTIFICATE OF OCCUPANCY ❑CORRECT WORK,CALL FOR REINSPECTION TEMPORARY BEFORE COVERING PERMANENT ❑CORRECT UNSAFE CONDITION WITHIN HOURS. ❑PHOTO TAKEN INSPECTOR WILL RETURN [ISTOP ORDER POSTED.CALL INSPECTOR ❑CITATION ISSUED ❑INSPECTION REQUIRED.CALL TO ARRANGE ACCESS. Call for the next inspection 24 hours in advance. (952R49-4600 OwnedContractor on site: Inspector. White CopyAnspectoes File Canary CopylSite Notice