Loading...
HomeMy WebLinkAboutseptic info CITY of ORONO Municipal Offices G Street Address: Mailing Address: �AxES1pg 2750 Kelley Parkway P.O, Box 66 Orono, MN 55356 Crystal Bay, MN 55323.0066 To: The Current Owner of Address 30 1..3 A City Ordinance requires that onsite sewage treatment systems in Orono be inspected on a periodic basis. The onsite sewage treatment system at the above address has been inspected and the following is known about the system. A sketch of the known components of the system is available for most properties at the Orono City Hall. Imminent Public Health Threat Yes / No If yes, pleasecontactthe Onsite Systems Manager at 952-249-4626 within 10 days of receipt of this notice. The septic system must be brought into compliance within 90 days. Failure to do so will result in referral to the City Attorney for legal action. System Identified as Non-Compliant Yes No If yes, system must be brought into compliance by: December 31, 2007 December 31, 2010 Other Septic Tank(s)-Pump out Needed Yes N6 � The City recommends the septic tank(s) and/or lift tank be serviced and pumped out every three years. City records indicate the tank(s) were last pumped out on J2 . The tank(s) should be cleaned through the manhole and not through the inspection pipes, this allows for proper cleaning. Comments: Inspector:.,. �- Date of Inspection Telephone(952)249-4600 a Fax(952)249-4616 www.ci.orono.mn.us o , o CITY of ORONO Municipal Offices �Ht Street Address: Mailing Address: p¢� 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN (5532366 To Current Owner: Address. City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFORMITY 0-3 : 1 1 "CODE SYSTEM"An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. 2 "COMPLIANT SYSTEM" An ISIS which does not meet all the location,design and construction standards of the current Orono Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and which is not failing or an imminent threat to public health or safety. 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISIS which may or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. TANK CONDITION(5-7): Tank inspection indicates: Pumpout not needed at this time. 6 Septic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years. Tank was last pumped tA3o`63 ). Make sure septic tanks are pumped through manhole and not through white inspection nines. This allows for the proper cleaning. Keep water softner and iron filter discharge out of septic system. 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If tanks have not been pumped out within the last three years,they should be pumped out now. DRAINFIELD CONDITION(8-10): Drainfield is dry,no surfacing evident. 9 Some evidence of surfacing,not critical yet. 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately.Repairs must be completed within 90 days. COMNErtTS: M 0 V�-� a- s�Q�—L j-l^ \x 0 Date of Inspection Matt Boltermatn- Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion ofthe adequacy ofthe system undercurrent conditions based on the available information. Tdephone(952)?49-4600 • Fax(952)249-4616 wwvrciorono.mn.� 0 g-� CITYof ORONO e' ,k0"! Municipal Offices "'%` �;,•'`u��yG Street Address: Mailing Address: '�k'Eg8Ca4` 2150 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323.0066 Owner: TIP M G n Address:_ 3 0 65 Wgfie,-to—,r\ R� City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFORMITY (1-3): 1 © "CODE SYSTEM" An ISTS which meets all the location,design and construction standards ofthe current Orono Municipal Code. 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location.design and construction standards orthe current Orono Municipal Code but does meet the three foot separation requirement,and which is not failing or an from:,, threat to public health or safety. 3 "NON-COMPLIANT SYSTEM" Aprohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. TANK CONDITION(5-10): s Tank inspection indicates: OPumpout not needed at this time. 6 Tank must be pumped out this year (city code requites tanks to be pumped out every 3 years. Tank was last pumped 5�3 -O, ) 7 Solids accumulation in tanks is at a critical a critical level. Tanks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. 9 Inspection risers missing-tanks could not be inspected Inspection risers(4"dia.pipe)must be installed in each tank at nest pumpout. If tanks have not been pumped out within the last three years,they should be pumped out now. 10 Inspection pipe is located directly over tank baffle(does not give accurate measurement of solids accumulation). If tanks have not been pumped out within the last three years,they should be pumped out now. DBARMIELD CONDITION 11-14,1: 11 11 Drainfield is dry,no surfacing evident. 12 Some evidence of surfacing,not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contactthe Citylispector immediately.Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. CO11 NMNTS: Syst tr%n k04,s o(C . Replgce ^Spey+'on caps D,� SeA+.c Date of Inspection Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or Certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the information system under cancan conditions baud on the available CITY OF ORONO O Municipal Offices O O Post Office Box 66 Crystal Bay, MN 55323-0066 ON—SITE SEWAGE TREATMENT r� INSPECTION REPORT �9kESHO4`� ` 3o w� 5� � Owner: Y 0 1 /�0 iAddress: Permit #'s: Dates: w�d2` i0 Contractors: F�Jc �L ' P/�SG37 C-CI. City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is Xan existing system I I new construction) SYSTEM CONFORMITY 1-3 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system which does not meet all the Location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system Located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic has or I ) has not been identified at this time. If the limiting soil characteristic has not been ident fie his classification may be subject to revision.) TANK CONDITION (5-10): inspection indicates: Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next punpout. If tanks have not been pumped out within the last three years, they should be pumped out now. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been pumped out within the last three years, they should be pumped out now. DRAINFIELD CONDITION (11-14): D,PfWieLd inspection indicates: Drainfield is dry, no surfacing evident. Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City inspector immediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (slope.setbacks.etc.): .� POTENTIAL FOR SYSTEM FAILURE (depends on soils.water table.etc.): 6 COMMENTS: 1 44 Date of In pection Septic Sy tem Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the system location and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner 0 0 �a���-� CITY of ORONO Municipal Offices Street Address: Mailing Address: 2150 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 Owner: CwtJC,4�nAddress: 3065 Watertown Rd. Permit #'s: 8510 Dates: 10/22/96 Contractors: E. J. Peterson Co. (This is ( ] an existing system (A new construction) . YSTEM COMPLIANCE (1-3) : 1 1 Code System: Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. 2 Compliant System: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance with previous codes and is functioning properly. 3 Non-Compliant System: System may or may not meet current City standards for design, construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level. (The saturated soil level is [>Q or is not [ ] identified under this septic system. If the saturated soil level is not i entified, this classification is subject to revision.) K CONDITION (5-9) : 5 5 Pumpout not needed at this time. Solids accumulation in tanks indicates they should be pumped out this year. 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out within three years, they should be pumped out and risers installed now. 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks have not been pumped out within three years, they should be pumped out now. 10 One or more tanks are cesspools, which means the septic system is non-compliant. (The tanks are [A or are not [ ] water tight or the condition is [ ] unknown. If the tanks are not confirmed to be watertight, this classification is subject to revision.) INFIELD CONDITION (11-14) : it �'111 Drainfield is dry, no surfacing evident. Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : low COMMENTS: Dateo�spection Sep c System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicates the operation of the system under current conditions. Telephone (612) 473-7357 9 FAX 473-0510 Aug 12 14 06:14p Joseph Olson 763-498-8290 p.2 Minnesota Pollution Compliance Inspection Form Control Agency 520 Lafayette Road North Existing Subsurface Sewage Treatment Systems SL Paul,MN 55155-4194 (SSTs) Doc Type:Compliance and Enforcement Instructions: tnspection results based on Minnesota Pollution Control Agency(MPGA) For local tracking purposes: requirements and attached forms—additional local requirements may also apply. Submit completed form to Local Unit of Government(LUG)and system owner within 15 days i System Status System status on date(mm/ddlyyyy): 6/25/2014 ® Compliant—Certificate of Compliance [] Noncompliant—Notice of Noncompliance (Valid for 3 years from report date, unless shorter time (See Upgrade Requirements on page 3) frame outlined in Local Ordnance.) Reason(s)for noncompliance(check all applicable) ❑ Impact on Public Heafth(Compliance Component #1)—Imminent threat to public health and safety ❑Other Compliance Conditions(Compliance Component#3)—Imminent threat to public health and safety ❑Tank Integrity(Compliance Component #2)—Failing to protect groundwater ❑Other Compliance Conditions(Compliance Component#3)—Failing to protect groundwater ❑Soil Separation(Compliance Component #4)—Failing to protect groundwater ❑Operating permit/monitoring plan requirements(Compliance Component #5)--Noncompliant Property Information Parcel Ipf#or Sec/TwpfRange: 04-117-23-22-0033 Property address: 3065 Watertown Road,Orono,MN Reason for inspection: Property Transfer Property owner: Chrysanne Manoles Owner's phone: 612-327-7779 or Owner's representative: Representative phone: Local regulatory authority: City of Orono Regulatory authority phone: 952-249-4600 2-1000 gallon septic tanks,1-1000 gallon lift station and 380 square feet of mound rockbed. per city Brief system description: records Comments or recommendations: Certification f hereby certify that all the necessary information has been gathered to determine the compliance status of this system.No determination of future system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system,inadequate maintenance, or future water usage. Inspector name: Joseph J Olson Certification number: 1255 Business name: _RysN O son's Soil& Perc.Testing License number: 810 Inspector signature: Phone number- 763-498-8779 Necessary or Locally Required Attachments ®Soil boring logs ® System/As-built drawing ❑Forms per local ordinance ❑Other information(list): www.pca.state.mn.us • 651.296-6300 • 800-657-3864 TTY 651-282-5332 or 800-657.3864 • Avaitabte in alternative formats ivq-wwl5ts4-31 • 1/24/12 Page t of 3 Aug 12 14 06:15p Joseph Olson 763-498-8290 p.3 Property address: 3065 Watertown Road,Orono,MN Inspector initials/Date: J.0.06/25/14 1. Impact on Public Health—Compliance component#1 of 5 Compliance criteria: Verification method(s): System discharge sewage to the ❑Yes ® No ® Searched for surface outlet _ round surface. ® Searched fior seeping in yardlbackup in home System discharge sewage to drain tile ❑Yes ®No ❑ Excessive ponding in soil system/D-boxes or surface waters. ❑ Homeowner testimony(See CommentalExplanation) ❑ "Black soil"above soil dispersal system System cause sewage backup into ❑Yes ® No ❑ System requires`emergency'pumping dwelling or establishment. ❑ Performed dye test Any"yes"answer above indicates the system is ❑ Unable to verify(See Comments/Explanation) an Imminent Threat to Public Health and Safety. ❑ Other methods not listed(See Comments/Explanation) CDmments/Exp lanation: 2. Tank Integrity—Compliance component#2 of 5 Compliance criteria: Verification method(s): System consists of a seepage pit, ❑ Yes ®No ® Probed tank(s)bottom cesspool,drywell, or leaching pit. ® Examined construction records Seepage pits meeting 7080.2550 may be ❑ Examined Tank Integrity Form(Attach) compliant if Mowed in kv.W ordinance. ❑ Observed liquid level below operating depth Sewage tank(s)leak below their [:]Yes 0 No ❑ Examined empty(pumped)tanks(s) designed operating geoh. If yes,which sewage tank(s)leaks: ❑ Probed outside tank(s)for`black soil" Any "yes"answer above indicates the ❑ Unable to verify(See CommenWExplanation) system is Failing to Protect Groundwater. El Other methods not fisted(See CommentslExplanation) CommentslExp lanation: 3. Other Compliance Conditions—Compliance component#3 of 5 a. Maintenance hole covers are damaged,cracked,unsecured,or appear to structurally unsound. []Yes* ® No ❑Unknown b. Other issues(electrical hazards,etc.)to immediately and adversely impact public health or safety. ❑Yes• ® No ❑Unknown `System/s an immirrent threat to public health and safety Explain: a System is non-protective of ground water for other conditions as determined by inspector ❑Yes* ®No '"tem is fairing to protect groundwater Explain: www.pca.state.mn.us - 651.296-6300 - 800.657-38(A TTY 651-282-5332 or 800-657-3864 - Available in altemative formats wq-ww1sts4-3f - 1124/12 Page 2 of 3 Aug 12 14 06:15p Joseph Olson 763-498-8290 p.4 Propertyaddress: 3065 Watertown Road,Orono,MN Inspector initials/Date: J.0.06125114 4. Soil Separation—Compliance component#4 of 5 Date of installation: 11119M ❑Unknown Verification method(s): ShorelandNYellhead protectiordFood Beverage ❑Yes M No Soil observation does notexpire.Previous soil Lodging? observations by two independent parties are sufficient Compliance criteria: unless site conditions have been altered or local For systems built prior to April 1, 1996, and E]Yes ®No requirements differ. not located in Shoreland or Wellhead ® Conducted soil observation(s)(Attach boring logs) Protection Area or not serving a food, ❑ Two previous verifications(Attach boring logs) beverage or lodging establishment: ❑ Not applicable(Holding tank(s),no drainfreld) Drainfield has at least a two-foot vertical ❑ Unable to verify(See Comments/Explanation) separation distance from periodically saturated soil or bedrock. ❑ Other(See CommenrsJExplanat;on) Non-performance systems built April 1, [K Yes ❑No Comment&Explanation: 1996, or later or for non-performance systems located in Shoreland or Wellhead Protection Areas or serving a food, beverage,or lodging establishment. Drainfield has a three-foot vertical separation distance from periodmcally saturated soil or bedrock.' "Experimental, "Other"or "Performance" ❑Yes ❑ No Indicate depths of elevations systems built under pre-2008 Rules;Type 1V or V systems built under 2008 Rules(7080. A. Bottom of distribution media 98.0 2350 or 7060.2400 (Advanced Inspector License required) B. Periodically saturated soillbedrodk 95.3 Drairdeld meets the designed vertical C_ System separation 2.7 separation distance from periodically saturated soil or bedrock. _ D_ Required compliance separation' 2.6 Any "no"answer above indicates the system is *May be reduced up to 15 percent if allowed by Local Failing to Protect Groundwater. Ordinance. 5. Operating Permit and Nitrogen BMP*—Compliance component#5 of 5 ® Not applicable Is the system operated under an Operating Permit? ❑Yes ❑No If"yes",A below is required Is the system required to employ a Nitrogen BMP? ❑Yes ❑No If"yes",B below is required BMP--Best Management Practice(s)specified in the system design If the answer to both questions is "no", this section does not need to be completed. Compliance criteria a_ Operating Permit number: No Have the OperatingPermit o ! C]Yes ❑ requirements been met. b. Is the required nitrogen BMP in place and properly functioning? Yes ❑No Any"no"answer indicates Noncompliance. Upgrade Requirements(Minn.Stat.§115.55)An imminent threat to public health and safety OTPHS)must be upgraded,replaced,or its use discorknued within ten months of recefo of this notice or within a shorter period if required by local ordinance.If the system is falling to protect ground water,the system must be upgraded,replacer!,or its use discontinued within the time required by local ordinance.If an existing system is not lading as defined in law,and has at least two feet of design soil separation,then the system need not be upgraded,repaired,replaced,or its use discontinued,notwithstanding any local ordfnence that is more strict_This provision does not apply to systems in shoreland areas, Wellhead Protecffon Areas,or those used in connection with food,beverage,and lodging establishments as defined in few. www.pca.state.mn.us • 651-246-6300 800-657-386a TTY 651-282-5332 or 800.657-3864 • Available in alterative formats wq-wwists4-3t • 1124/11 Page 3 of 3 Aug 12 14 06:15p Joseph Olson 763-498-8290 p.5 Logs of Soil Borings License#810 Location or Project: 3065 Watertown Road Borings made by: Rusty Olson's Soil and Perc testing 6/25/2014 Classification System: AASHO ; USDS•USDS-SCS X ; Unified ; Other Auger used (check two): Hand_Xor Power_, Flight, Bucket or Probe_X_ Boring Number_1_Surface elevation_99.6_ Mottled Soil at X feet 0-26" Fill in original soils 26"48" Dark brown loam 10yr3/1 Boring Number_2—Surface elevation_95.6` Mottled Soil at 1.7 feet 0-20"Dark brown loam 10yi3/1 in original soils 20"-26"Rusty brown loam 10yr4/3 TBNI: Top of lift station manhole cover Elv.-100.0 assumed Bottom of rock bed Elv-98.0 Original soil under the rockbed Elv.- 97.0 There is 1.0 feet of sand under the rockbed Aug 12 14 06:15p Joseph Olson 763-498-8290 p.6 �J V♦�� I� +A �f'� t 1 I p i I I A TMn�?,Da'o r T30 S76 60 / l i Aug 12 14 06:14p Joseph Olson 763-498-8290 p.1 ,1 Fax Transmittal Form Date: 8/12/2014 Total Pages: 116 To. City of Orono Phone Number: Fax Number: 952-249-4616 E-mail: From: Joseph J Olson Phone Number: 763-498-8779 Fax Number: 763-498-8290 E-mail: rusty2654ncomcast.net [� urgent ❑Q For Review ❑ Please Comment ❑ Please Reply Message: This is the septic cert for 3065 Watertown Road.. Please file