Loading...
HomeMy WebLinkAboutRe: retaining wall 2 p.oNg:(612)70641299 Fat:(612)70&8202 29 ANTNQNY LAME SOU111 � rrWW'PM*WQ.0" ttE 100 Awt1ONY,(M�-40MA 36419-3277 �,1 l:!:�t]�.N'�', pwo.ih;t"r t•:�(;l\Ia�:t21 .� \t.\. t:MON1E[R! • AN��r6T! 6GlN1f01� Ef,uCATOPs December 5, 2000 Todd Irvine Keenan& Sveiven 15600 Wayzata Boulevard,Suite 4106 Wayzata, MN 55391 11111111111 1111111111, Re: PEM Project 074003 3020 Watertown Road, Orono Dear Todd: you requested, we have examined the stone gravity rztaining structure at the above- Asreferenced address.The purpose of my examination was to collect information needed to analyze the structure for stability. The structure is a stone%mvity retaining wall with a maximum height of 5' 8". The highest portion of the wall has four courses of boulders, each boulder weighing approximately 500 pounds. The back face of the boulder wall is lined with a filter fabric to reduce erosion of the grdnular backfUl through the wall face. of the highest theion of topof the the wall,we measured approximately 2' .8"batter from he wall, corresponding to a 25-degree angle from vertical. Based on our analyses, the structure has safety factors of.2.3 against overturning,and 1,5 against sliding along its base. These safety factors meet professional engineering standards for this type of construction. Please call if we can provide further assistance. Sincerely, PROJECT ENGINEERING & MANAGEMENT. INC. Chris Arlaudson,P.E. Vice President thereby certify that this report wits prepared by me or under my direct tie., s(on and that l am a duly regluered Profes!jional Engineer under he laws of t S to;fM1I1Znota. -. igned: ter - innesota Registration Number:26806 Z0 39Vd N3AI3AS (INV NVN33M L9919Lb 60:91 000Z/50/ZT