December 5, 2000
Todd Irvine
Keenan& Sveiven
15600 Wayzata Boulevard,Suite 4106
Wayzata, MN 55391
11111111111 1111111111,
Re: PEM Project 074003 3020 Watertown Road, Orono
Dear Todd:
you requested, we have examined the stone gravity rztaining structure at the above-
Asreferenced address.The purpose of my examination was to collect information needed to
analyze the structure for stability.
The structure is a stone%mvity retaining wall with a maximum height of 5' 8". The
highest portion of the wall has four courses of boulders, each boulder weighing
approximately 500 pounds. The back face of the boulder wall is lined with a filter fabric
to reduce erosion of the grdnular backfUl through the wall face.
of the highest
theion of
topof the
the wall,we measured approximately 2' .8"batter from he
wall, corresponding to a 25-degree angle from vertical.
Based on our analyses, the structure has safety factors of.2.3 against overturning,and 1,5
against sliding along its base. These safety factors meet professional engineering
standards for this type of construction.
Please call if we can provide further assistance.
Sincerely,
PROJECT ENGINEERING & MANAGEMENT. INC.
Chris Arlaudson,P.E.
Vice President thereby certify that this report wits prepared by me or under my direct
tie.,
s(on and that l am a duly regluered Profes!jional Engineer under
he laws of t S to;fM1I1Znota.
-. igned:
ter -
innesota Registration Number:26806
Z0 39Vd N3AI3AS (INV NVN33M L9919Lb 60:91 000Z/50/ZT