HomeMy WebLinkAbout2013-00032 - mechanical VV* CITY OFORONO * 2013 - 00032 * 2750 KELLEY PARKWAY DATE ISSUED: 01/15/2013 ORONO, MN 55356- (952) 249-4600 FAX: (952) 249-4616 ADDRESS Lr 45 WATERTOWN RD �j d PIN 04;, -21-0003 LEGAL DESC AUDITOR'S SUBD.NO.230 LOT 008 BLOCK 000 PERMIT TYPE MECHANICAL(>$500) PROPERTY TYPE : RESIDENTIAL CONSTRUCTION TYPE : MECHANICAL-MULTIPLE VALUATION : $ 64,690.00 NOTE: (1)GEOCOMFORT-GXT060-60,000 OUTPUT BTU'S, 1800 CFM (1)GEOCOMFORT-GWT048-48,000 OUTPUT BTU'S (1)TRIANGLE TUBE-SOLO 175-NATURAL GAS-3"FLUE- 175,000 INPUT BTU'S, 168,00 OUTPUT BTU'S (1)GEOCOMFORT-COOLING SYSTEM-GXT060-5 TONS- 1.5 H.POWER (1)KITHCEN EXHAUST-6"DUCT-300 CFM APPLICANT MECHANICAL 808.63 MASSMANN,GEOTHERMAL&MECH STATE SURCHARGE MECH(VALUATION) 32.35 27944 96TH STREET ZIMMERMAN,MN 55398 TOTAL 840.98 (763)416-5066 OWNER Watertown Properties LLC 16440 41ST AVE N PLYMOUTH,MN 55446- AGREEMENT AND SWORN STATEMENT The work for which this permit is issued shall be performed according to the approved plans and specifications,applicable City approvals,and the State Building Code. This permit is for only the work described and does not grant permission for additional or related work which requires separate permits. All provisions of laws and ordinances governing this type of work shall be compied with whether or not specified herein.This permit will expire and become null and void if construction authorized is not commenced within 180 days of the date of issuance,or if construction is suspended for a period of 180 days at any time after work has commenced. The applicant is responsible for assuring all required inspections are requested in con rmance with the State Building Code.This permit may be revoked at an "ime for due se. Ap is erre tee ureDate slu�ySign ure Date SEPARATE PERMITS REQUIRED FOR WORK OTHER THAN DESCRIBED ABOVE. FOR CTTY USE ONLY City of Orono O4 �O P.O.Box 66 Date Received: Permit# 2750 Kelley Parkway Crystal Bay,MN 55323 Approved By: Amount$: Phone(952)249-4600 Fax(952)249-4616 CITY OF ORONO–MECHANICAL PERMIT (All Commercial permits must be approved by the Building Official or Inspector and/or Fire Marshall) GENERAL INFORMATION I. You may apply for mechanical permits by mail or in person at the City offices. Applications will be reviewed and a permit will be issued within two working days. 2. Permit cards will be sent by return mail after a review is completed. PERMITS ARE NOT VALID UNTIL YOU RECEIVE A PERMIT. WORK MUST NOT BEGIN UNTIL THE PERMIT CARD IS POSTED ON THE JOB SITE. 3. Mechanical Designs—Complete calculations,details and specifications are required for each heating,ventilation,humidification-dehumidification,and air conditioning installation including heat loss/heat gain calculation,design temperatures,equipment ratings and identification as to type,manufacturer and model. Data shall be presented on form provided. 4. When any new construction or remodeling is involved,a separate building permit must be obtained. 5. All work must be done in accordance with the Uniform Mechanical Code/State Building Code requirements. 6. All work must be inspected(rough-in and final). Call(952)249-4600. (24-48 hour notice required) 7. House Heating Test Record must be submitted before final. TYPE OF PERMIT Check All That Apply) ❑■ Residential ❑Commercial(Approval Required) ■❑ New ❑Additional ❑Repairs ❑Replace Job Site/Owner Information: O Dr-H f O-C40t— d n tI 6p S j Site A dyes • Watertown RD F12q Vt/la.d2 j'►'tISaft, owner: Gordon James Mailing Address: P.O. BOX 306 City: Maple Plain MN Zip: 55359 Home Phone: (612) 369-3736 Alternate Phone: Contractor Information: Contractor: MassmannGeothermal&Mech. Contact Person: Jason Massmann Address: 27944 96th Street North west State Bond#: M B 0 0 3 9 81 City: Zimmerman MN Zip:55398 Expiration Date: 10/15/14 Phone: (763) 389-0376 Alternate Phone: (763) 286-5769 ❑ Insurance–Current: Cornerstone Insurance Group 1 Note: All Geothermal Systems will now require a Site Plan&Review by our Building Official. IS THIS GEOTHERMAL? ❑■ Yes ❑No HEATING SYSTEMS Quantity: 1 1 1 Make: GeoComfrot GeoComofort Triangle tube Model: GXT060 GWT048 Solo175 Fuel: Geothermal Geothermal Natural Gas Flue size: None None 3" Input BTUs: 175,000 Output BTUs: 60,000 48000 168,000 CFM: 1800 None None COOLING SYSTEMS Quantity: 1 Make: GeoComfort Model: GXT060 Tons: 5 H.Power 1 .5 FIREPLACES e!Sj Qje4�S ❑ Gas Factory Fireplace Brand Name: ❑ Wood Burning Fireplace ❑ Wood Stove Model No.: ❑ Wood Stove with Flue/Masonry VENTILATION ❑ No. 1 Kitchen Exhaust 6„ duct recirculating 300 cf n ❑ No. 9 Bath Exhaust(must have duct outside) 80 cfm ❑ No. Other Fans: Locations cfm FUEL STORAGE (Must be approved by Fire Marshall ijproposing to abandon tank in place.) ❑ Installation ❑ Removal Fuel Oil: gallons ❑ Underground ❑Inside ❑Outside LP Gas: gallons Other: GAS LINE ONLY ❑ Outdoor Grill ❑ Other/List What&Where: 7 Gas lines including main. 2 S` M- WI-0 F ❑ Yes,this section applies The replacement of a Residential fixture or appliance that meets all three of the following requirements: 1. Does not require modification to electrical or gas service. 2. Has a total cost of$500.00 or less;excludine the cost of the fixture or appliance:and 3. Is improved,installed or replaced by the homeowner or licensed contractor. Skip next section,if this applies; Cost of Permit $ 15.00 State Surcharge $ 5.00 Mail-In Fee(If Applicable) $ 2.00 Total Permit Fee $ "'n If above does not apply;follow guidelines below: 1. CONTRACT PRICE * is 1.25%of contract price with a(Minimum Fee of$50.00) 64,690.00 _ x.0125$ 808.63 (contract price) (minimum$50.00) 2. STATE SURCHARGE 64,690.00 32.35 x.0005 $ (contract price) 3. POSTAGE&HANDLING(Only on Mail-In Applications) $ 2.00 4. TOTAL PERMIT FEE(Add Lines 1-3 Above) $840.98 ■ * CONTRACT PRICE or JOB COST means the actual or estimated dollar amount charged for the permitted work including materials, labor,profit, and other fixed costs. It is the amount to be charged to the customer for the work done. If any material, equipment, labor or installations are furnished by the owner,tenant or any other party,the reasonable market value of such items must be added to the estimated cost or contract price for permit fee purposes. In the event that there is a dispute on the amount of the job cost, the City may request the submission of a signed copy of the actual contract. The undersigned hereby applies to the City for issuance of a Mechanical Permit, agrees to do all work in strict accordance with the ordinances of the City and the regulations of the State of Minnesota, and certifies that all statements made on this application are complete, true and correct. Applicant's Signature: Date: / /S 3� 3 ao 13-0003-2- Load 3-00032Load Short Form Job: Z(oy6 Date: Sep 16,2012 Entire House By: Massmann Geothermal 27944 96th St NW,Zimmerman,MN 55398 Phone:763-389-0376 Fax:763-389-0386 Email:jason@massmanngeothermal.com Web:www.massmanngeothermal.com Project • • • "R0", For: Gordon James Con. Vanoverbeke Residence 2645 Watertown Rd, Orono, MN 10 Htg Clg Infiltration Outside db (°F) -22 97 Method Simplified Inside db (°F) 70 75 Construction quality Semi-tight Design TD (°F) 92 22 Fireplaces 0 Daily range - M Inside humidity(%) 30 50 Moisture difference (gr/Ib) 32 50 HEATING EQUIPMENT COOLING EQUIPMENT Make Enertech Manufacturing LLC. Make Enertech Manufacturing LLC. Trade GEOCOMFORT Trade GEOCOMFORT Model GT060 Cond GT060 AHRI ref no.3000398 Coil AHRI ref no.3000398 Efficiency 3.29 COP Efficiency 19.38 EER Heating input 46178 Btuh Sensible cooling 47885 Btuh Heating output 46178 Btuh Latent cooling 20522 Btuh Temperature rise 20 OF Total cooling 68407 Btuh Actual air flow 2207 cfm Actual air flow 2207 cfm Air flow factor 0.018 cfm/Btuh Air flow factor 0.047 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.94 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) Garage Zone p 1507 27210 0 477 0 Main Zone p 2395 41397 26305 726 1230 Upper Zone p 1528 31857 14956 559 699 Lower Zone p 2395 25382 10249 445 479 Entire House d 7825 125845 47098 2207 2207 Other equip loads 3026 0 Equip. @ 1.02 RSM 48040 Latent cooling 2981 TOTALS 7825 128872 51021 2207 2207 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri htsOft 2013-Jan-1109:04:50 9 Right-Suite®Universal 8.0.18 RS000282 Page 1 ...rmal\My Documents\Wrightsoft HVAC\Gordon James Vanoverbeke.rup Calc=MJS Front Door faces: Loads for Multiple Orientations Job: Date: Sep 16,2012 Entire House By: Massmann Geothermal 27944 96th St NW,Zimmerman,MN 55398 Phone:763-389-0376 Fax:763-389-0386 Email:jason@massmanngeothermal.com Web:www.massmanngeothermal.com ProjectInformation ' For: Gordon James Con. Vanoverbeke Residence 2645 Watertown Rd, Orono, MN CIS Design Conditionsp Location: Indoor: Heating Cooling Minneapolis-St. Paul, MN, US Indoor temperature (°F) 70 75 Elevation: 837 ft Design TD (°F) 92 22 Latitude: 45°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 32.4 50.0 Dry bulb (°F) -22 97 Infiltration: Daily range(°F) - 19 ( M ) Wet bulb (°F) - 78 Wind speed (mph) 15.0 7.5 Front Door North Northeast East Southeast South Southwest West Northwest Sensible Load (13tuh) 48040 40919 34336 41196 44608 43561 37388 46886 Latent Load (Btuh) 2981 2981 2981 2981 2981 2981 2981 2981 Total Load (Btuh) 51021 43900 37317 44177 47588 46542 40369 49866 Heating AVF (cfm) 2207 1880 1577 1892 2049 2001 1717 2154 Cooling AVF (cfm) 2207 1880 1577 1892 2049 2001 1717 2154 Building Orientation Cooling Load 60000- 50000 L �,✓ 7 / co 40000-- o 0000 a o 0 J m S 30000 o 0 U 6 20000-- 10000-- 0 0000100000 N NE E SE S SW W NW Direction Front Door faces Current Orientation: Front Door faces North Highest Cooling Load: Front Door faces North Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-Jan-1109:04:50 wri htsofRight-Suite®Universal 8.0.18 RS000282 Page 1 rmal\My Documents\Wrightsoft HVAC\Gordon James Vanoverbeke.rup Calc=MJ8 Front Door faces: BuildingAnalysis Job: J Date: Sep 16,2012 Entire House By. Massmann Geothermal 27944 96th St NW,Zimmerman,MN 55398 Phone:763-389-0376 Fax:763-389-0386 Email:jason@massmanngeothermal.com Web:www.massmanngeothermal.com '" • ect Information For: Gordon James Con. Vanoverbeke Residence 2645 Watertown Rd, Orono, MN Design Conditions Location: Indoor: Heating Cooling Minneapolis-St. Paul, MN, US Indoor temperature (°F) 70 75 Elevation: 837 ft Design TD (°F) 92 22 Latitude: 45°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 32.4 50.0 Dry bulb (°F) -22 97 Infiltration: Daily range (°F) - 19 ( M ) Method Simplified Wet bulb (°F) - 78 Construction quality Semi-tight Wind speed (mph) 15.0 7.5 Fireplaces 0 -77 Heating 'Ie:r Component Btuh/ft' Btuh % of load Walls 5.4 38246 29.7 ..� Glazing 43.2 37039 28.7 Doors 28.2 14839 11.5 Ceilings 2.3 9201 7.1 Floors 0.8 3305 2.6 Infiltration 3.7 23216 18.0 Ducts 0 0 Piping 3026 2.3 Humidification 0 0 Ventilation 0 0 Adjustments 0 Total 128872 100.0 Coolin• Component Btuh/ft2 Btuh % of load Walls 0.9 6518 13.8 /`— Glazing 37.3 31979 67.9 Doors 5.0 2640 5.6 Ceilings 1.0 3841 8.2 Floors 0 0 0 Infiltration 0.3 2120 4.5 Ducts 0 0 Ventilation 0 0 Internal gains 0 0 Blower 0 0 Adjustments 0 Total 47098 100.0 Latent Cooling Load = 2981 Btuh Overall U-value = 0.070 Btuh/ft2-°F Data entries checked. 2013-Jan-1109:04:52 wri ht50fRight-Suite®Universal 8.0.18 RS000282 Page 1 rmal\My Documents\Wrightsoft HVAC\Gordon James Vanoverbeke.rup Calc=MJ8 Front Door faces: Component Constructions Job: p Date: Sep 16,2012 Entire House By: Massmann Geothermal 27944 96th St NW,Zimmerman,MN 55398 Phone:763-389-0376 Fax:763-389-0386 Email:jason@massmanngeothermal.com Web:www.massmanngeothermal.com Project Information " 1 For: Gordon James Con. Vanoverbeke Residence 2645 Watertown Rd, Orono, MN Design Conditions Location: Indoor: Heating Cooling Minneapolis-St. Paul, MN, US Indoor temperature (°F) 70 75 Elevation: 837 ft Design TD (°F) 92 22 Latitude: 45°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 32.4 50.0 Dry bulb (°F) -22 97 Infiltration: Daily range (°F) - 19 ( M ) Method Simplified Wet bulb (°F) - 78 Construction quality Semi-tight Wind speed (mph) 15.0 7.5 Fireplaces 0 ------------ Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft' Btuh/ft?'F W°F/Btuh Btuh/ft' Btuh Btuh/ft' Btuh Walls 12E-Osw:Firm wall,wd ext,3/8"wood shth, r-19 cav ins,5/8" n 1174 0.068 19.0 6.26 7345 1.34 1578 gypsum board int fnsh,2"x6"wood firm a 1117 0.068 19.0 6.26 6991 1.08 1212 S 1069 0.068 19.0 6.26 6688 1.20 1283 w 1063 0.068 19.0 6.26 6650 1.10 1164 all 4423 0.068 19.0 6.26 27673 1.18 5237 15813-4wc-6: Bg wall, light dry soil,2"x4"wood int firm,concrete n 514 0.046 17.0 4.69 2413 0.31 160 wall, r-2 ins, r-13 cav ins, 10"thk, 1/2"gypsum board int fnsh e 675 0.046 17.0 4.79 3236 0.34 230 s 549 0.046 17.0 4.79 2632 0.34 187 w 524 0.046 17.0 4.37 2291 0.15 80 all 2262 0.046 17.0 4.67 10573 0.29 657 Partitions 12C-Osw: Firm wall,stucco ext, r-13 cav ins,2N4"wood frm 360 0.091 13.0 0 0 1.73 624 Windows 4A5-2ow:2 glazing,clr low-e outr,argon gas,wd firm mat,clr innr, n 98 0.470 0 43.2 4238 16.2 1586 1/4"gap, 1/4"thk n 35 0.470 0 43.2 1513 16.2 567 e 155 0.470 0 43.2 6684 35.2 5440 s 68 0.470 0 43.2 2940 18.9 1287 w 371 0.470 0 43.2 16042 37.6 13936 w 130 0.470 0 43.2 5621 39.3 5103 all 857 0.470 0 43.2 37039 32.6 27920 Doors 11 P0: Door,mtl pur core type in 21 0.290 10.5 26.7 560 9.85 207 e 63 0.290 10.5 26.7 1681 9.85 620 s 35 0.290 10.5 26.7 934 9.85 345 w 63 0.290 10.5 26.7 1681 9.85 620 w 21 0.290 10.5 26.7 560 9.85 207 all 203 0.290 10.5 26.7 5416 9.85 1999 11 GO: Door,wd pnl type a 35 0.540 0 49.7 1739 18.3 642 11 P0:Door,ovhd mtl,pur core type a 144 0.290 10.5 26.7 3842 0 0 s 144 0.290 10.5 26.7 3842 0 0 all 288 0.290 10.5 26.7 7684 0 0 2013-Jan-1109:04:52 Wrl htSOft Right-Suite®Universal 8.0.18 RS000282 Page 1 rmal\My Documents\Wrightsoft HVAC\Gordon James Vanoverbeke.rup Calc=MJ8 Front Door faces: Ceilings 16B-44ad:Attic ceiling,asphalt shingles roof mat,r-44 veil ins 3902 0.022 44.0 2.02 7898 0.78 3027 C part ceiling,:C part ceiling,frm fir,12"thkns 40 0.354 1.0 32.6 1303 20.3 814 Floors 21 B-28t:Bg floor,heavy dry or light damp soil,full ext ins cov,6.5' 2395 0.015 3.0 1.38 3305 0 0 depth,r-10 ins,tile flr fnsh 4380:Radiant panel over room,3/4"ply subflr,Omega heat xfer 1507 0 0 0 0 0 0 plates 2013-Jan-11 09:04:52 W rightSOft Right-Suite®Universal 8.0.18 RS000282 Page 2 ...nnalUWy Documents\Wrightsoft HVAC\Gordon James Vanoverbeke.rup Calc=MJ8 Front Door faces: Project Summary Job: 7 Date: Sep 16,2012 Entire House By: Massmann Geothermal 27944 96th St NW,Zimmerman,MN 55398 Phone:763-389-0376 Fax:763-389-0386 Email:jason@massmanngeothermal.com Web:www.massmanngeothermal.com ''`'� • t • .tea' For: Gordon James Con. Vanoverbeke Residence 2645 Watertown Rd, Orono, MN Notes: Design Inf• • Weather: Minneapolis-St. Paul, MN, US Winter Design Conditions Summer Design Conditions Outside db -22 °F Outside db 97 °F Inside db 70 °F Inside db 75 °F Design TD 92 °F Design TD 22 °F Daily range M Relative Humidity 50 % Moisture difference 50 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 125845 Btuh Structure 47098 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 3026 Btuh Equipment load 128872 Btuh Use manufacturer's data n Rate/swing multiplier 1.02 Infiltration Equipment sensible load 48040 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2981 Btuh Ducts 0 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area (ft') 7825 6318 Equipment latent load 2981 Btuh Volume (ft') 56755 41685 Air changes/hour 0.25 0.13 Equipment total load 51021 Btuh Equiv.AVF (cfm) 236 90 Req. total capacity at 0.70 SHR 5.7 ton Heating Equipment Summary Cooling Equipment Summary Make Enertech Manufacturing LLC. Make Enertech Manufacturing LLC. Trade GEOCOMFORT Trade GEOCOMFORT Model GT060 Cond GT060 AHRI ref no.3000398 Coil AHRI ref no.3000398 Efficiency 3.29 COP Efficiency 19.38 EER Heating Input 46178 Btuh Sensible cooling 47885 Btuh Heating output 46178 Btuh Latent cooling 20522 Btuh Temperature rise 20 °F Total cooling 68407 Btuh Actual air flow 2207 cfm Actual air flow 2207 cfm Air flow factor 0.018 cfm/Btuh Air flow factor 0.047 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.94 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-Jan-11 09:04:52 wrightsoft Right-Suite®Universal 8.0.18 RS000282 Page 1 ...rmal\My Documents\Wrightsoft HVAC\Gordon James Vanoverbeke.rup Calc=MJ8 Front Door faces: AED Assessment Job: Date: Sep 16,2012 Entire House By: Massmann Geothermal 27944 96th St NW,Zimmerman,MN 55398 Phone:763-389-0376 Fax:763-389-0386 Email:jason@massmanngeothermal.com Web:www.massmanngeothermal.com Project Information For: Gordon James Con. Vanoverbeke Residence 2645 Watertown Rd, Orono, MN Design Conditions Location: Indoor: Heating Cooling Minneapolis-St. Paul, MN, US Indoor temperature(°F) 70 75 Elevation: 837 ft Design TD (°F) 92 22 Latitude: 45°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 32.4 50.0 Dry bulb (°F) -22 97 Infiltration: Daily range (°F) - 19 ( M ) Wet bulb (°F) - 78 Wind speed (mph) 15.0 7.5 Test for • • Exposure Dive 7W, rsity ` Hourly Glazing Load 40,000 35,000-- 30,000-- 25,000-- o 5,00030,00025,000o 20,000-- 15,000-- 10,000-- 5,000-- 0 0,00015,00010,0005,0000 — 8 9 10 11 12 13 14 15 16 17 18 19 20 Hour of Day Hourly A s AED limit Maximum hourly glazing load exceeds average by 46.3%. House does not have adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 4059 Btuh (PFG - 1.3*AFG) Wrl htSOft 2013-Jan-1109:04:52 9 Right-Suite®Universal 8.0.18 RS000282 Page 1 ...rmal\My Documents\Wrightson HVAC\Gordon James Vanoverbeke.rup Calc=MJ8 FrontDoor faces: Right-M Worksheet Job: Entire House Date: Sep 16,2012 By: Massmann Geothermal 27944 96th St NW,Zimmerman,MN 55398 Phone:763-389-0376 Fax:763-389-0386 Email:jason@massmanngeothermal.com Web:www.massmanngeothermal.com 1 Room name Entire House Garage Zone 2 Exposed wall 878.0 ft 166.0 ft 3 Ceiling height 9.2 ft d 10.0 ft p 4 Room dimensions 5 Room area 7825.0 ft' 1507.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat TC001 Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Ic�W 12E-Osw 0.068 n 6.26 1.34 1293 1174 7345 1578 240 240 1501 0 LI-- 4A5-2ow 0.470 n 43.24 16.19 98 0 4238 1586 0 0 0 0 - 11 PO 0.290 n 26.68 9.85 21 21 560 207 0 0 0 0 %f�-G 15B13-4wc-6 0.068 n 4.69 0.31 549 514 2413 160 0 0 0 0 11 4A5-2ow 0.470 n 43.24 16.19 35 0 1513 567 0 0 0 0 12E-Osw 0.068 a 6.26 1.08 1514 1117 6991 1212 560 400 2502 0 4A5-2ow 0.470 a 43.24 35.19 155 0 6684 5440 16 0 692 0 11G0 0.540 a 49.68 _ 18.33 35 35 1739 642 0 0 0 0 11130 0.290 a 26.68 9.85 63 63 1681 620 0 0 0 0 11 PO 0.290 a 26,68 0.00 144 144 3842 0 144 144 3842 0 W 15B13-4wc-6 0.068 a 4.79 0.34 675 675 3236 230 0 0 0 0 l(V 12E-Osw 0.068 s 6.26 1.20 1316 1069 6688 1283 470 310 1939 0 4A5-2ow 0.470 s 43.24 18.93 68 0 2940 1287 16 0 692 0 11P0 0.290 s 26.68 9.85 35 35 934 345 0 0 0 0 11 PO 0.290 s 26.68 0.00 144 144 3842 0 144 144 3842 0 W 151313-4wc-6 0.068 s 4.79 0.34 549 549 2632 187 0 0 0 0 \� 12E-Osw 0.068 w 6.26 1.10 1497 1063 6650 1164 390 374 2340 0 I-G 4A5-2ow 0.470 w 43.24 37.56 371 0 16042 13936 16 0 692 0 11 PO 0.290 w 26.68 9.85 63 63 1681 620 0 0 0 0 15B134wc-6 0.068 w 4.37 0.15 675 524 2291 80 0 0 0 0 4A5-2ow 0.470 w 43.24 39.26 130 0 5621 5103 0 0 0 0 D 11 PO 0.290 w 26.68 9.85 21 21 560 207 0 0 0 0 P 12C-Osw 0.091 0.00 1.73 360 360 0 624 0 0 0 0 C 1613-44ad 0.022 2.02 0.78 3902 3902 7898 3027 1507 1507 3050 0 C C part ceiling, 0.354 32.58 20.34 40 40 1303 814 0 0 0 0 F 21 13-28t 0.015 1.38 0.00 2395 2395 3305 0 0 0 0 0 F 4380 0.042 0.00 0.00 1507 1507 0 0 1507 1507 0 0 6 c)AED excursion 4059 0 Envelope loss/gain 102629 44978 21092 0 12 a) Infiltration 23216 2120 6117 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants 230 0 0 0 0 Appliances/other 0 1 0 Subtotal(lines 6 to 13) 125845 47098 27210 0 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 125845 47098 27210 0 15 Duct loads 1 0% 0% 0 0 0% 0%1 0 0 Total room load 125845 47098 27210 0 Air required(cfm) 2207 2207 477 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri htsoft` 2013-Jan-1109:04:53 9 Right-Suite®Universal 8.0.18 RS000282 Page 1 ...rmal\My Documents\Wrightsoft HVAC\Gordon James Vanoverbeke.rup Calc=MJ8 Front Door faces: Right-J®Worksheet Job: Entire House Date: Sep 16,2012 By: Massmann Geothermal 27944 96th St NW,Zimmerman,MN 55398 Phone:763-389-0376 Fax:763-389-0386 Email:jason@massmanngeothermal.com Web:www.massmanngeothermal.com 1 Room name Main Zone Upper Zone 2 Exposed wall 232.0 ft 208.0 It 3 Ceiling height 9.0 ft p 9.0 ft p 4 Room dimensions 5 Room area 2395.0 ft2 1528.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat C001 Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 T 12E-Osw 0.068 n 6.26 1.34 549 496 3103 838 504 438 2740 740 4A5-2ow 0.470 n 43.24 16.19 53 0 2292 858 45 0 1946 728 11 PO 0.290 n 26.68 9.85 0 0 0 0 21 21 560 207 V�J 15613-4wc-6 0.068 n 4.69 0.31 0 0 0 0 0 0 0 0 11 -G 4A5-2ow 0.470 n 43.24 16.19 0 0 0 0 0 0 0 0 12E-Osw 0.068 a 6.26 1.08 522 390 2440 659 432 327 2048 553 4A5-2ow 0.470 a 43.24 35.19 76 0 3286 2983 63 0 2706 2457 11 GO 0.540 a 49.68 18.33 35 35 1739 642 0 0 0 0 11 PO 0.290 a 26.68 9.85 21 21 560 207 42 42 1121 414 11 PO 0.290 a 26.68 0.00 0 0 0 0 0 0 0 0 W 151313-4wc-6 0.068 a 4.79 0.34 0 0 0 0 0 0 0 0 VjJ 12E-Osw 0.068 s 6.26 1.20 342 271 1695 458 504 488 3053 825 1--•G 4A5-2ow 0.470 s 43.24 18.93 36 0 1557 891 16 0 692 396 LI-_pp 11 PO 0.290 s 26.68 9.85 35 35 934 345 0 0 0 0 11 PO 0.290 s 26.68 0.00 0 0 0 0 0 0 0 0 W 15613-4wc-6 0.068 s 4.79 0.34 0 0 0 0 0 0 0 0 12E-Osw 0.068 w 6.26 1.10' 675 392 2452 662 432 297 1858 502 4A5-2ow 0.470 w 43.24 37.56 262 0 11329 10285 93 0 4021 3651 11 PO 0.290 w 26.68 9.85 21 21 560 207 42 42 1121 414 TJ15613-4wc-6 0.068 w 4.37 0.15 0 0 0 0 0 0 0 0 4A5-2ow 0.470 w 43.24 39.26 0 0 0 0 0 0 0 0 11 PO 0.290 w 26.68 9.85 0 0 0 0 0 0 0 0 P 12C-Osw 0.091 0.00 1.73 360 360 0 624 0 0 0 0 C 166-44ad 0.022 2.02 0.78 867 867 1755 1096 1528 1528 3093 1931 C C part ceiling, 0.354 32.58 20.34 0 0 0 0 0 0 0 0 F 21 B-28t 0.015 1.38 0.00 0 0 0 0 0 0 0 0 F 43BO 0.042 0.00 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion 4596 1283 Envelope loss/gain 33702 25351 24959 14100 12 a) Infiltration 7695 954 6899 855 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 1 41397 26305 31857 14956 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 41397 26305 31857 14956 15 Duct loads 0% 0% 0 0 0% 0% 0 0 Total room load 41397 26305 31857 14956 Air required(cfm) 1 1 726 12301 1 559 699 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. +I+ wrightsoft' Right-Suite®Universal 8.0.18 RS000282 2013-Jan-11 OPage 2 rmal\My Documents\Wrightsoft HVAC\Gordon James Vanoverbeke.rup Calc=MJ8 Front Door faces: Right-J®Worksheet Job: Entire House Date: Sep 16,2012 By: Massmann Geothermal 27944 96th St NW,Zimmerman,MN 55398 Phone:763-389-0376 Fax:763-389-0386 Email:jason@massmanngeothennal.com Web:www.massmanngeothermal.com 1 Room name Lower Zone 2 Exposed wall 272.0 ft 3 Ceiling height 9.0 ft p 4 Room dimensions 5 Room area 2395.0 ft2 Ty Construction U-value Or HTM Area (ftp Load Area Load number (Btuh/ft2°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 12E-Osw 0.068 n 6.26 1.34 0 0 0 0 4A5-2ow 0.470 n 43.24 16.19 0 0 0 0 D 11 PO 0.290 n 26.68 9.85 0 0 0 0 %t15B13-4wc-6 0.068 n 4.69 0.31 549 514 2413 160 11 �G 4A5-2ow 0.470 n 43.24 16.19 35 0 1513 567 12E-Osw 0.068 a 6.26 1.08 0 0 0 0 4A5-2ow 0.470 a 43.24 35.19 0 0 0 0 11GO 0.540 a 49.68 18.33 0 0 0 0 11 PO 0.290 a 26.68 9.85 0 0 0 0 11 PO 0.290 a 26.68 0.00 0 0 0 0 W 15813-4wc-6 0.068 a 4.79 0.34 675 675 3236 230 12E-0sw 0.068 s 6.26 1.20 0 0 0 0 -G 4A5-2ow 0.470 s 43.24 18.93 0 0 0 0 �-D 11 PO 0.290 s 26.68 9.85 0 0 0 0' II--D 11 PO 0.290 s 26.68 0.00 0 0 0 0 W 15B13-4wc-6 0.068 s 4.79 0.34 549 549 2632 187 12E-Osw 0.068 w 6.26 1.10 0 0 0 0 4A5-2ow 0.470 w 43.24 37.56 0 0 0 0 ��--DD 11P0 0.290 w 26.68 9.85 0 0 0 0 \�/ 15813-4wc-6 0.068 w 4.37 0.15 675 524 2291 80 I-G 4A5-2ow 0.470 w 43.24 39.26 130 0 5621 5103 LLL D 11 PO 0.290 w 26.68 9.85 21 21 560 207 P 12C-Osw 0.091 0.00 1.73 0 0 0 0 C 16B-44ad 0.022 2.02 0.78 0 0 0 0 C C part ceiling, 0.354 32.58 20.34 40 40 1303 814 F 21 B-28t 0.015 1.38 0.00 2395 2395 3305 0 F 43BO 0.042 0.00 0.00 0 0 0 0 6 c)AED excursion 2592 Envelope loss/gain 22876 9939 12 a) Infiltration 2506 311 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal(lines 6 to 13) 25382 10249 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 25382 10249 15 Duct loads 0% 0% 0 0 Total room load 25382 10249 Air required(cfm) 1 445 479 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft' Right-Suite®Universal 8.0.18 RS000282 2013-Jan-11 OPage 3 ...nnal\My Documents\Wrightsoft HVAC\Gordon James Vanoverbeke.rup Calc=MJ8 Front Door faces: Load Multizone Summary Report Job: Date: Sep 16,2012 By: Massmann Geothermal 27944 96th St NW,Zimmerman,MN 55398 Phone:763-389-0376 Fax:763-389-0386 Email:jason@massmanngeotherrnal.com Web:www.massmanngeothermal.com Infiltration Summary Heating Cooling ZONE NAME Volume ACH AVF HTM Volume ACH AVF HTM ft3 cfm Btuhlft2 ft3 cfm Btuhlft2 Garage Zone 15070 0.25 62 3.7 0 0 0 0 Main Zone 21555 0.22 78 3.7 21555 0.11 41 0.5 Upper Zone 13752 0.31 70 3.7 13752 0.16 36 0.5 Lower Zone 6378 0.24 26 3.7 6378 0. 12 13 0.5 Entire House 56755 0.25 236 1 3.7 1 41685 0. 13 90 0.5 2013-Jan-11 09:04:54 Wr19htSOft` Right-Suite®universal 8.0.18 RS000282 Page 1 ...rrnal\My Documents\Wrightsoft HVAC\Gordon James Vanoverbeke.rup Calc=MJ8 Front Door faces: • • and AVF Summary ROOM NAME Area Htg load Clg load Htg AVF Clg AVF ftZ Btuh Btuh cfm cfm Garage 1507 27210 0 477 0 Garage Zone 1507 27210 0 477 0 Main Bath 50 549 324 10 15 Mudroom 91 184 399 3 19 Mud WIC 40 824 394 14 18 Laundry 58 117 69 2 3 Pantry 45 1417 904 25 42 Stairs 108 2471 1108 43 52 Foyer 196 2628 1671 46 78 Study 156 3488 942 61 44 Master WIC 126 2905 1294 51 60 Master Bath 154 3204 1893 56 89 Master Bedroom 333 6409 4319 112 202 Powder Bath 35 0 0 0 0 Dining 153 8974 6853 157 321 Kitchen 376 4127 1795 72 84 Great Room 474 4100 4340 72 203 Main Zone 2395 41397 26305 726 1230 Play Area 382 3919 2446 69 114 Office WIC 56 1187 276 21 13 Office Bath 60 121 69 2 3 Office 223 6848 3473 120 162 Upper laundry 70 1959 735 34 34 Upper Stairs 108 2837 1382 50 65 Reading/TV 117 2258 675 40 32 Bedroom #2 169 4691 2370 82 111 Bath 2&3 156 2463 602 43 28 Bedroom #3 187 5575 2927 98 137 Upper Zone 1528 31857 14956 559 699 Mech Room 539 6183 1146 108 54 Lower Stairs 108 1249 88 22 4 Wine 104 824 55 14 3 Lower Bath 60 83 0 1 0 Storage 318 2743 185 48 9 Game Room 802 8644 5926 152 277 Exercise 216 1450 93 25 4 Guest Bedroom 248 4206 2755 74 129 Lower Zone 2395 25382 10249 445 479 Entire House 7825 125845 47098 2207 2207 2013-Jan-11 09:04:54 Wr19htSOft" Right-Suite®Universal 8.0.18 RS000282 Page 2 ...rmal\My Documents\Wrightsoft HVAC\Gordon James Vanoverbeke.rup Calc=MJS Front Door faces: °�•�R��Ii�E€��€I�S�����7����3����6a�s$�¢��da3e?��aR���$�AI}�s��� m s a ° \ 0- \ 402.12` (: ti W GO Jr J; jl C R l r + CJ �•u II rj � a +�"+bi i � R ,�—a Om•d r a� I r "�. I r� I 12 A. � E CILL4 3.0000•[05 � I / /' �\ !� '• g 'y £I'� ! I iv vv��i'rvi�:: .navvy !A �' °,i^, I i �� 9 sfl o kg fF a T 9�< as k e q�'�sA@i aaFi� s e� g 5i3 n �?• & �$ 550 1S '�y¢i��+ � A� ��y- - `33 ilE'a CERTIFICATE OF SURVEY ` „ m PREPARED FOR p SATHRE-BERGQUIST, INC. GORDON JAMES CONSTRUCTION (* sosouTNeaonownrwnv2ATn,NN.ssasiIssz)476-6 1 O Ln Z $ t5 RFRe vt (n �??_ ��Alfo 7 f �t� DATE TIME CITY OF ORONO CALLED ININSPECTION NOTICE /�( �{� SCHEDULED ' r�� PE IT NO.-L't�" Cty� COMPLETED 2"A�ESS OWNER LloI _4' TELEPHONE NO. 3 317 -G37(, CONTRACTOR ` 7 a e— L / DESCRIPTION " �t�.ln. ❑ FOOTING ❑ PLUMBING FINAL ❑ EXCAV/GRADING/FILLING Q ❑ POURED WALL ❑ MECHANICAL RI ❑ LAKESHORE/WETLANDS y ❑ FRAMING ❑ MECHANICAL FINAL ❑ TREE REMOVAL Z ❑ INSULATION ❑ WOOD BURNER/FIREPLACE ❑ SITE INSPECTION Q ❑ RADON SLAB ❑ WATER HOOK-UP ❑ PROGRESS ❑ FINAL ❑ SEWER HOOK-UP ❑ COMPLAINT ❑ DEMO-SITE ❑ SEPTIC MAINT. ❑ FOLLOW-UP ❑ DEMO-FINAL ❑ SEPTIC INSTALL ❑ HARD COVER REMOVAL v ❑ PLUMBING RI ❑ SEPI FINAL ❑ FOUNDATION/REMOVAL OWNER/CONTRACTOR TO MEET YOU: YES_NO COMMENTS: W a " a 0 U_ W cc Q z W Z W d WW IFFWOFittSATISFACTORY:PROCEED ElPROJECT COMPLETE W ❑CORRECT WORK&PROCEED ❑ ISSUE CERTIFICATE OF OCCUPANCY ❑CORRECT WORK,CALL FOR REINSPECTION TEMPORARY U BEFORECOVERING PERMANENT ❑CORRECT UNSAFE CONDITION WITHIN HOURS. ❑ PHOTO TAKEN INSPECTOR WILL RETURN L1 CITATION ISSUED ❑STOP ORDER POSTED.CALL INSPECTOR ❑ INSPECTION REQUIRED.CALL TO ARRANGE ACCESS. Call for the next inspection 24 hours in advance. (952) 249-4600 Owner/Contractor on !te: Inspector. l White Copy/Inspector's File Canary Copy/Site Notice V,`_ ATE TIME L CITY OF ORONO CALLED IN a-ji INSPECTION NOTICE SCHEDULED C2_a� PERMIT NO.o;1013-DD0L%Z COMPLETED ADDRESS 2,6J45 Gy OWNER TELEPHONE NO. 163 31Gj X1374 CONTRACTOR 3; DESCRIPTION ❑ FOOTING ❑ PLUMBING FINAL ❑ EXCAV/GRADING/FILLING ❑ POURED WALL ❑ MECHANICAL RI ❑ LAKESHORE/WETLANDS O ❑ FRAMING ❑ MECHANICAL FINAL ❑ TREE REMOVAL Z ❑ INSULATION ❑ WOOD BURNER/FIREPLACE ❑ SITE INSPECTION Q ❑ RADON SLAB ❑ WATER HOOK-UP ❑ PROGRESS ❑ FINAL ❑ SEWER HOOK-UP ❑ COMPLAINT J ❑ DEMO-SITE ❑ SEPTIC MAINT. ❑ FOLLOW-UP ❑ DEMO-FINAL ❑ SEPTIC INSTALL ❑ HARD COVER REMOVAL v ❑ PLUMBING RI ❑ SEPTIC FINAL ❑ FOUNDATION/REMOVAL OWNERICONTRACTOR TO MEET YOU:_YES_NO COMMENTS: cc W Q_ cc S cc 0 W W cc Q z W z W CC K SATISFACTORY.PROCEED 11 PROJECT COMPLETE CC dW W CT WORK&PROCEED ElISSUE CERTIFICATE OF OCCUPANCY Q ❑CORRECT WORK,CALL FOR REINSPECTION TEMPORARY C1 BEFORECOVERING PERMANENT ❑CORRECT UNSAFE CONDITION WITHIN HOURS. ❑ PHOTOTAKEN INSPECTOR WILL RETURN ❑STOP ORDER POSTED.CALL INSPECTOR ❑CITATION ISSUED ❑ INSPECTION REQUIRED.CALLTO ARRANGE ACCESS. Call for the next inspection 24 hours in advance. (952) 249-4600 Owner/Contractor on site: Inspector. White Copy/Inspector's File Canary Copy/Site Notice DAT TIME/ CITY OF ORONO CALLED IN INSPECTION NOTICE SCHEDULED PERMIT NO. r�D���°Z. COMPLETED ADDRESS�o �� W OWNER TELEPHONE NO.7 �3 /1 ,,/�� CONTRACTOR ►��1�—`��/ �' 6� >; DESCRIPTION ❑ FOOTING ❑ PLUMBING FINAL ❑ EX AV GRADING/FI NG tjj Q ❑ POURED WALL ❑ MECHANICAL RI ❑ LAKESHORE/WETLANDS y ❑ FRAMING ❑ MECHANICAL FINAL ❑ TREE REMOVAL Z ❑ INSULATION ❑ WOOD BURNER/FIREPLACE ❑ SITE INSPECTION Q ❑ RADON SLAB ❑ WATER HOOK-UP ❑ PROGRESS ❑ FINAL ❑ SEWER HOOK-UP ❑ COMPLAINT v ❑ DEMO-SITE ❑ SEPTIC MAINT ❑ FOLLOW-UP ❑ DEMO-FINAL ❑ SEPTIC INSTALL ❑ HARD COVER REMOVAL v ❑ PLUMBING RI ❑ SEPTIC FINAL ❑ FOUNDATION/REMOVAL OWNERICONTRACTOR TO MEET YOU:_YES_NO o COMMENTS: CC W CL cc a Cr 0 LL W CC Q Z W Z W cc GW vWdUQaK SATISFACTORY:PROCEED ❑ PROJECT COMPLETE rc ❑CORRECT WORK&PROCEED ❑ ISSUE CERTIFICATE OF OCCUPANCY W O ❑CORRECT WORK,CALL FOR REINSPECTION TEMPORARY C 1 BEFORE COVERING PERMANENT ❑CORRECT UNSAFE CONDITION WITHIN HOURS. ❑ PHOTO TAKEN INSPECTOR WILL RETURN ❑STOP ORDER POSTED.CALL INSPECTOR 11 CITATION ISSUED ❑ INSPECTION REQUIRED.CALL TO ARRANGE ACCESS. Call for the next inspection 24 hours in advance. (952) 249-4600 Owner/Contractor on site: -� Inspector. - White Copy/Inspector's File Canary Copy/Site Notice DATE TIME I CITY OF ORONO CALLED IN INSPECTION NOTICE SCHEDULED PERMIT NO. 010/_5-0003 - COMPLETED ADDRESS OWNER TEu0 0.70 CONTRACTOR Q DESCRIPTION W ❑ FOOTING ❑ PLUMBING FINAL ❑ EXCAV/GRADING/FILLING ❑ POURED WALL ❑ MECHANICAL RI ❑ LAKESHORE/WETLANDS y O ❑ FRAMING El MECHANICAL FINAL ❑ TREE REMOVAL Z ❑ INSULATION ❑ WOOD BURNER/FIREPLACE ❑ SITE INSPECTION Q ❑ RADON SLAB ❑ WATER HOOK-UP ❑ PROGRESS ❑ FINAL ❑ SEWER HOOK-UP ❑ COMPLAINT \ v ❑ DEMO-SITE ❑ SEPTIC MAINT. ❑ FOLLOW-UP LU ❑ DEMO-FINAL ❑ SEPTIC INSTALL ❑ HARD COVER REMOVAL v ❑ PLUMBING RI ❑ SEPTIC FINAL ❑ FOUNDATION/REMOVAL OWNERICONTRACTOR TO MEET YOU:—YES_NO COMMENTS: Qc W C 0 cc o cc ( ) k /uSS LU ^j t Q Z W Z W W ORKSATISFACTORY:PROCEED ❑ PROJECT COMPLETE W ❑CORRECT WORK&PROCEED ElISSUE CERTIFICATE OF OCCUPANCY 0 ❑CORRECT WORK,CALL FOR REINSPECTION TEMPORARY V BEFORE COVERING PERMANENT ❑CORRECT UNSAFE CONDITION WITHIN HOURS. ❑ PHOTO TAKEN INSPECTOR WILL RETURN ❑STOP ORDER POSTED.CALL INSPECTOR El CITATION ISSUED ❑ INSPECTION REQUIRED.CALL TO ARRANGE ACCESS. Call for the next inspection 24 hours in advance. (J52) 249-4600 Owner/Contractor on site: Inspector. White Copy/Inspector's File Canary Copy/Site Notice CITY OF ORONO CALLED IN DATE TI INSPECTION NOTICE SCHEDULED PERMIT NO. 242 13 -O X3,2 COMPLETED ADDRESS 265f6l A,4 `-6611+ �• OWNER TELEPHONE NO. CONTRACTOR DESCRIPTION ❑ FOOTING ❑ PLUMBING FINAL ❑ EXCAV/GRADING/FILLING ❑ POURED WALL ❑ M ❑ LAKESHORE/1NETLANDS Q ❑ FRAMING �MECHANICAL FINAJ ❑ TREE REMOVAL 2 ❑ INSULATION WOO RNER/FIREPLACE ❑ SITE INSPECTION Q ❑ RADON SLAB ❑ WATER HOOK-UP ❑ PROGRESS ❑ FINAL C1SEWER HOOK-UP C1 COMPLAINT v ❑ DEMO-SITE ❑ SEPTIC MAINT. ❑ FOLLOW-UP ❑ DEMO-FINAL ❑ SEPTIC INSTALL ❑ HARD COVER REMOVAL v ❑ PLUMBING RI Cl SEPTIC FINAL ❑ FOUNDATION/REMOVAL Z OWNERICONTRACTOR TO MEET YOU:_YES_NO ti COMMENTS: �cr` r� - o? '�P'-/3 - AJ6'•k a j ^-e,A G'.t. —s-d J - 3 - `yra�o -Ckg--✓�cK s o a-b�•rt3 U. O �• W �6` Cr wt sL Uj ❑WORK SATISFACTORY.PROCEED �ROJECT COMPLETE W ❑CORRECT WORK&PROCEED ❑ISSUE CERTIFICATE OF OCCUPANCY O ❑CORRECT WORK,CALL FOR REINSPECTION TEMPORARY V BEFORE COVERING PERMANENT ❑CORRECT UNSAFE CONDITION WITHIN HOURS. ❑PHOTO TAKEN INSPECTOR WILL RETURN ❑CITATION ISSUED ❑STOP ORDER POSTED.CALL INSPECTOR ❑INSPECTION REWIRED.CALL TO ARRANGE ACCESS. Call for the next inspection 24 hours in advance. (952) 249-4600 OwnedContractor on site: Inspector. White Copyllnspector's File Canary CopylSite Notice