To: The Current Owner of Address WA+-er+e) N
City Ordinance requires that onsite sewage treatment systems in Orono be
inspected on a periodic basis. The onsite sewage treatment system at the above
address has been inspected and the following is known about the system. A
sketch of the known components of the system is available for most properties at
the Orono City Hall.
Imminent Public Health Threat
Yes
No
If yes, please contact the Onsite Systems Manager at 952-249-4626 within 10
days of receipt of this notice. The septic system must be brought into compliance
within 90 days. Failure to do so will result in referral to the City Attorney for
legal action.
System Identified as Non-Compliant
Yes
No
If yes, system must be brought into compliance by:
December 31, 2007
December 31,2010
Other
Septic Tanks ump out Needed
Yes
No
The City recommends the septic tank(s) and/or lift tank be serviced and pumped
out every three years. City records indicate the tank(s) were last pumped out on
�j o fe Cut D . The tank(s) should be cleaned through the manhole and
not through the inspection pipes, this allows for proper cleaning.
Comments:
Inspector: Date of Inspection
Telephone(952)249-4600 a Fax (952)249-4616
www.ci.orono.mn.us
O
O O
CITYof ORONO
Municipal Offices
f '
',;•'���;;.� ,�G Street Address: Mailing Address:
yHp¢ 2750 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323.0066
lav
To Current Owner: Address: d 3aT q-Rrwr\ ki
City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below.
S STEM CONFORMITY 1-3 : �
�)"ICOMPLIANT
CODE SYSTEM" An ISTs which meets all the location,design and construction standards of the current Orono Municipal Code.SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono Municipal
Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and which is not failing or
an imminent threat to public health or safety.
3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may
or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any reason;and
any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics.
TANK CONDITION(5-7): Co
Tank inspection indicates:
5 Pumpout not needed at this time.
0-eptic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years.
Tank was last pumped ).
Make sure septic tanks are pumped through manhole and not through white inspection pines. This allows for the
proper cleaning. Keep water softner and iron filter discharge out of septic system.
7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If
tanks have not been pumped out within the last three years,they should be pumped out now.
D1&2jELD CONDITION(8-10):
Drainfield is dry,no surfacing evident.
9 Some evidence of surfacing,not critical yet.
10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately.Repairs must be completed within 90 days.
COMAEivTS: ac^_a,�-:�� foo OK- MD
ti-b fir- \bCc D-\) -,- h is C Q
�C' t- Gr�, k
Date of Inspection Matt Bolterman- Septic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee
or certify that an existing system will continue to function properly,but is merely an opinion ofthe adequacy of the system under current conditions based on the available
information.
Telephone(952)2494600 • Fax(952)2494616
wWWAA orono.mn ns
0 0
r, CITY of ORONO
Municipal Offices
Street Address: Mailing Address:
2150 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323.0066
Owner: Address: a3DS wg-teft-ow,
City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below.
SYSTEM CONFORMITY (1-3): �
O "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code.
2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono Municipal
Code but does meet the three foot separation requirement,and which is not failing or an imminent threat to public health or safety.
3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may
or may not meet all the location,design,or construction standards ofthe current Orono Municipal Code and which is failing for any reason;and
any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics.
TANK CONDITION(5-10): 6
Tank inspection indicates:
5 Pumpout not needed at this time.
60 Tank must be pumped out this year (city code requires tanks to be pumped out every 3 years. Tank was last pumped
7 Solids accumulation in tanks is at a critical a critical level. Tanks should be pumped out as soon as possible.
8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge.
9 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank at next pumpout. If tanks
have not been pumped out within the last three years,they should be pumped out now.
10 Inspection pipe is located directly over tank baffle(does not give accurate measurement of solids accumulation). If tanks have not been pumped
out within the last three years,they should be pumped out now.
DRAWFIELD CONDITION(11-14): V\
Drainfield is dry,no surfacing evident.
12 Some evidence of surfacing,not critical yet.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately.Repairs must be
completed within 90 days.
14 Drainfield extent and condition unknown.
COMMENTS: S y5�Z, \0 ok-S 0k
y <�'c co �5
o t �1rllazr
Date of Inspection Septic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee
or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available
information.
CITY OF ORONO O
Municipal Offices O O
Post Office Box 66
Crystal Bay, MN 55323-0066 ON–SITE SEWAGE TREATMENT
INSPECTION REPORT
9ktsilo
Owner: �E��N /t P���/ //G(/�SPR Address: ej AJC AJA1z`W1641,n
Permit #19: Dates: _ e—;2r 7 Contractors: Vy IQknm, ,(SSS•
City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked below.
(This iSX an existing system [ ) new construction)
SYSTEM CONFORMITY (1-3): L
1"') "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
without discharging any pollutants into ground or surface waters.
2 "CONFORMING SYSTEM"-A system which does not meet all the Location, design, and construction standards of the
current City Codes, but was installed according to the code in effect at the time of installation, and which
is operating satisfactorily by treating and disposing of the entire current sewage input without discharging
any pollutants into ground or surface waters.
3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any
system which may or may not meet all the location, design, and construction standards of the current City
Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand
between the distribution device and the Limiting soil characteristics.
(The limiting soil characteristic�Q has or [ ) has not been identified at this time. If the Limiting soil
characteristic has not been identified, this classification may be subject to revision.)
TANK CONDITION (5-10):
inspection indicates:
5 Pumpout not needed at this time.
Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems.
7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible.
8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge.
9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each
tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped
out now.
10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation).
If tanks have not been pined out within the last three years, they should be pumped out now.
DRAINFIELD CONDITION (11-14):
field inspection indicates:
11 Drainfield is dry, no surfacing evident.
Some evidence of surfacing, not critical yet.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately. Repairs must be completed within 90 days.
14 Drainfield extent and condition unknown.
LIMITING SITE FACTORS (slope.setbacks.etc.): —
POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table.etc.): TO
COMMENTS:
Date of Inspection Septic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or certify that an existing system will continue to function
properly, but is merely an opinion of the adequacy of the system under current conditions based on the available
information.
This report must be kept on the premises with the system Location and pumping records.
WHITE COPY/Inspectors File YELLOW COPY/Homeowner
0 0
CITYof ORONO
Municipal Offices
G
Street Address: Mailing Address:
E$II 2150 Kelley Parkway P.O. Box 66
/ Orono, MN 55356 Crystal Bay, MN 55323.0066
Owner: 1 ke, � %� Address: 2325 Watertown Rd.
Permit #'s: 8313 Dates: 8/29/96 Contractors: Widmer Bros.
(This is [x] an existing system [ ] new construction)
YSTEM COMPLIANCE (1-3) :LT 1
Code System: Meets or exceeds current City standards in all respects relating to design,
construction, and location. Appears to be operating properly.
2 Compliant System: Does not meet all current City standards for new construction, but in
most respects appears to be designed, located, and constructed in accordance with previous
codes and is functioning properly.
3 Non-Compliant System: System may or may not meet current City standards for design,
input; and any system with less
construction, or location, but is failing to properly treat and dispose of the current
than three feet of vertical separation between the bottom
of the drainfield and the saturated soil level.
(The saturated soil level [x ] has or [ ] has not been identified at this time. If the
saturated soil level has not been identified, this classification is subject to revision.)
&tlK CONDITION (5-9) : 5
Pumpout not needed at this time.
6 Solids accumulation in tanks indicates they should be pumped out this year.
7 System is discharging to the surface. Tanks must be pumped out within 48 hours.
8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out
within three years, they should be pumped out and risers installed now.
9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks
have not been pumped out within three years, they should be pumped out now.
(During the last septic tank Maintenance Pumpout the tanks [ i were or 0<
I notto be watertight by the licensed pumping contractor. If the tanks were n ore confirmed coned
tbe
watertight, this classification is subject to revision.)
Qg8INFIELD CONDITION (11-14) : 11
Drainfield is dry, no surfacing evident.
2 Some evidence of surfacing, not critical yet. Repair is not required at this time.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface.
Contact the City Inspector immediately. Repair must be completed within 90 days.
14 Drainfield extent and condition unknown.
POTENTIAL FOR SYSTEM FAILURE: (system acre and condition, soils, etc.) : low
COMMENTS:
M I?-9?
Date of Inspection
4SVc System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a
transfer of property, this report does not guarantee that an existing system will continue to
function properly, but indicates the operation of the system under current conditions.
Telephone (612) 473-7357 0 FAX 473-0510
SEPTIC SYSTEM INVENTORY
Addr: 2325 Watertown Rd. PID: 03-117-23 22 0011
Building Type : nursery # BRs/GPD: # Systems/units : 1/1
Permit No: none Date of Permit : Installer: unknown
System Type : standard trench Appliances :
SYSTEM CONDITION
Conformity: 3 Tank Condition: 9 DF condition: 13
Failure Pot : failing
SEPTIC TANKS
Material : Capacity:
Setback to Bldg:
DRAINFIELD
Length of Lines : No. Lines : Trench Width:
Treatment Area: Type of Filter:
Tile Size : Under Tile : Perc Rate mn/in:
Setback DF-Bldg: DF Ht above WT:
Soil Type : Limitations : water table
WELL DATA
Setbacks - Well-Tanks : Well-DF:
Report in File? : Pump Type :
Depth: Diameter: Method:
INSPECTION RECORD PUMPOUT RECORD
Date Compliance Date Gallons
10/22/82 no surfacing-exact tank location unknown 2 1/1/85 1500
8/29/86 no surfacing 2 8/1/88 800
8/31/88 no surfacing 2 9/27/96 2000
5/3/91 DF surfacing 4
5/9/94 DF surfacing 3
8/30/95 DF surfacing-pump tanks 3
6/26/96 DF surfacing-repair by 9/31/96 3
_.
-_ _ .__
___
i
��
,;
� � ; ,
� ;
� � �
-�
ii
� � -+-
� � �
; �_� ��.
I
i --- ___-
_ _ _ ._ -
I
CITY of ORONO
titi Municipal Offices
Street Address: Mailing Address:
2750 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323-0066
Owner: �-/f� I� Address:2325 Watertown Rd.
Permit #'s:none Dates: Contractors:unknown
(This is A an existing system [ ] new construction)
SYSTEM COMPLIANCE (1-3) : 3
1 Code System: Meets or exceeds current City standards in all respects relating to
design, construction, and location. Appears to be operating properly.
2 Compliant System: Does not meet all current City standards for new construction,
but in most respects appears to be designed, located, and constructed in accordance
with previous codes and is functioning properly.
@3 Non-Compliant System: System may or may not meet current City standards for design,
construction, or location, but is failing to properly treat and dispose of the
current input; and any system with less than three feet of vertical separation
between the bottom of the drainfield and the saturated soil level.
(The saturated soil level [ ] has or ,Y,-'
]� has not been identified at this time. If the
saturated soil level has not been identified, this classification is subject to revision.)
TANK CONDITION (5-9) : 9
5 Pumpout not needed at this time
6 Solids accumulation in tanks indicates they should be pumped out this year.
7 System is discharging to the surface. Tanks must be pumped out within 48 hours.
8 Inspection risers missing-tanks could not be inspected. If tanks have not been
pumped out within three years, they should be pumped out and risers installed now.
Inspection pipe is located over tank baffle-can not measure solids accumulation. If
tanks have not
been pumped out within three years, they should be pumped out now.
(During the last septic tank Maintenance Pumpout the tanks [ ] were or V were not
confirmed to be watertight by the licensed pumping contractor. If the tanks were not
confirmed to be watertight, this classification is subject to revision.)
DRAINFIELD CONDITION (11-14) : 13
11 Drainfield is dry, no surfacing evident.
12 Some evidence of surfacing, not critical yet. Repair is not required at this time.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface.
Contact the City Inspector immediately. Repair must be completed within 90 days.
14 Drainfield extent and condition unknown.
POTENTIAL FOR SYSTEM FAILURE: (system acre and condition, soils etc. ) : failing
COMMENTS:The system must be repaired by 9/31/96.
4��_W '4�� ;4/'_/_M�
Date of Inspection S ptic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a
transfer of property, this report does not guarantee that an existing system will continue
to function properly, but indicates the operation of the system under current conditions.
Telephone (612) 473-7357 0 FAX 473-0510
o o
CITY of ORONO
��� ✓ �, Municipal Offices
ti
Street Address: Mailing Address:
0 2150 Kelley Parkway P.O. Box 66
SII
Orono, MN 55356 Crystal Bay, MN 55323.0066
January 6, 1994
Kelly & Kelly Nursery
2325 Watertown Road
Long Lake, Minnesota 55356
Dear Sirs:
Due to the extremely wet year, we realize that the required repair of your septic system may
have been difficult to complete last summer. This is a reminder that the septic system repair
will be required next year.
A licensed septic contractor must get a permit from the City of Orono by July 15, 1994 for the
repair of your septic system. The procedure for completing septic system repairs is shown
below. Please contact me at the City offices if there are any questions.
PROCEDURE FOR SEPTIC SYSTEM REPAIR
1. Hire a Site Evaluator/System Designer to do the soil testing and system design.
2. Submit the design to the City for approval.
3. Once the design is approved, have one or more contractors bid on the approved design.
4. The contractor you choose should then obtain a permit from the City before starting work.
He will call the City for the required inspections.
Sincerely,
Stephen Weckman
On-Site Systems Manager
SW/ch
Enc. Septic Report
List of Septic Contractors and Site Evaluators/Designers
Telephone (612) 473-7357 • FAx 473-0510
CITY OF ORONO O
Municipal Offices O O
Post Office Box 66
Crystal Bay, MN 55323-0066 a ON—SITE SEWAGE TREATMENT
INSPECTION REPORT
sHo4�G
Owner: �� L�Address: �'<'�> /� //.LnI47, /�L�f;►
Permit #'s: I'1L�1'1Q� Dates: Contractors:
City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked below.
(This is Ix an existing system I ) new construction)
SYSTEM CONFORMITY (1-3):
1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
without discharging any pollutants into ground or surface waters.
2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the
current City Codes, but was installed according to the code in effect at the time of installation, and which
is operating satisfactorily by treating and disposing of the entire current sewage input without discharging
any pollutants into ground or surface waters.
3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any
system which may or may not meet all the location, design, and construction standards of the current City
Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand
between the distribution device and the limiting soil characteristics.
(The limiting soil characteristic ( I has orhas not been identified at this time. If the limiting soil
characteristic has not been identified, this as ification may be subject to revision.)
TANK CONDITION (5-10):
Tank inspection indicates:
5 Punpout not needed at this time.
6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems.
7 Solids accumulation in tanks is at a critical level. of nks should be pumped out as soon as possible.
System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge.
Inspection risers missing-tanks could not be inspected. Ins ction risers (4" dia. pipe) must be installed to ea
tank at next f tanks of been ou wt in the
Out [IV
10 Inspe'ZRit —p pe is located directlyover tank baffle (does not give a solids accumulation).
If tanks have not been pumped out within the last three years, they should be pumped out now.
DRAINFIELD CONDITION (11-14):
Drainfield inspection indicates:
11 Drainfield is dry, no surfacing evident.
Some evidence of surfacing, not critical yet.
13 Drainf" t ar inr ect
ted effluent to the surface. Contact the City Insp
tm W dta1&L+V_ Reppaairs must be completed wit in YU days-.-------
14 Drainfl'e &extent and tbndition unknown.
LIMITING SITE FACTORS (slope.setbacks.etc.):
POTENTIAL FOR SYSTEM FAILURE (depends on soils.water table.etc.): /
COMMENTS:
Date of Inspection Syst m nspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or certify that an existing system will continue to function
property, but is merely an opinion of the adequacy of the system under current conditions based on the available
information.
This report must be kept on the premises with the system location and pumping records.
WHITE COPY/Inspectors File YELLOW COPY/Homeowner
CITY OF ORONO O
Municipal Offices O O
Post Office Box 66
Crystal Bay, MN 55323-0066 ON—SITE SEWAGE TREATMENT
INSPECTION REPORT
9kEsH.o��
Owner: k #--k,- Allrse Address:
Permit #'s: fie+ Dates: Contractors: //17 ugV
City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked below.
(This is lean existing system I ) new construction)
SYSTEM CONFORMITY (1-3):
1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
without discharging any pollutants into ground or surface waters.
2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the
current City Codes, but was installed according to the code in effect at the time of installation, and which
is operating satisfactorily by treating and disposing of the entire current sewage input without discharging
any pollutants into ground or surface waters.
"NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any
system which may or may not meet all the location, design, and construction standards of the current City
Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand
between the distribution device and the limiting soil characteristics.
(The limiting soil characteristic I ) has or 6"s not been identified at this time. If the limiting soil
characteristic has not been identified, this classification may be subject to revision.)
TANK CONDITION (5-10):
Tank inspection indicates:
5 Pumpout not needed at this time.
6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems.
7 Solids accumulation in tanks is at a critical level. 'tanks should be pumped out as soon as possible.
System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge.
9 inspection risers missing-tanks could not be inspected. Ins ction .
tank at next punpout. if tanks have not been ou wt to the last three years, they should be pu x�cl
10 Inspe ton p is located directly over tank baffle (does not give accurate measurement of solids accumulation).
If tanks have not been pumped out within the last three years, they should be pumped out now.
DRAINFIELD CONDITION (11-14):
Drainfield inspection indicates:
11 Drainfield is dry, no surfacing evident.
]2� Some evidence of surfacing, not critical yet.
( / Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately. Repairs must be completed within 90 days.
14 Drainfield extent and Condition unmown.
LIMITING SITE FACTORS (slope.setbacks.etc.):
POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table.etc.):
COMMENTS:
Date of Inspection p c Systd1m Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or certify that an existing system will continue to function
properly, but is merely an opinion of the adequacy of the system under current conditions based on the available
information.
This report must be kept on the premises with the system location and pumping records.
WHITE COPY/Inspectors File YELLOW COPY/Homeowner
W71_-qV
On the North Shore of
Lake Minnetonka
ON-SITE SEWAGE TREATMENT CITY
INSPECTION REPORT OF POST OFFICE BOX 66
_ONO 1335 S. Brown Rd.
Crystal Bay, MN 55323
473-7357
OWNER /�L�¢��J�� ADDRESS ay
PERMIT NO.'S. DATES CONTRACTORS
City Ordinance No. 210 requires that each onsite sewage treatment system in Orono be inspected on a regular basis.The on-site sewage
treatment system at the above address has been inspected and appears to fall into the category checked below.
(This is V an existing system ❑ new construction)
El1 Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating
properly.
2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed,
located, and constructed generally in accordance with previous codes.System appears to be functioning properly;no major
upgrading of the system is required at this time.
E33 Does not meet current City standards in many respects relating to design,construction,or location.Appears to be operating
adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at
this time.
104 System may or may not meet current City standards for design,construction or location,but is failing to properly treat and
dispose of the current input,and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is
creating a safety hazard,or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/
replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan
must be submitted for review.Your contractor must obtain a permit before work is started.
SYSTEM CONDITION!m Checked items may require your action)
Tank inspection indicates: ❑ Inspection pipe is located directly over tank baffle.(Does not
❑ Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks
❑ Solids accumulation in tanks indicates they should be pump- have not been pumped out within the last three years,they
ed out this year to help prevent future problems. should be pumped out now.
❑ Solids accumulation in tanks is at a critical level. Tanks Drainfield inspection indicates:
should be pumped out as soon as possible. ❑ Drainfield is dry,no surfacing evident.
❑ System is discharging to surface. Tanks must be pumped ❑ Some evidence of surfacing,not critical yet.
within 48 hours to eliminate surface discharge. eA416 Drainfield is saturated and visibly discharging untreated
1AIns ction risers missing—tankss cted. effluent to the surface. This condition may require replace-
Inspection risers 4"dia. pipe)must be installed in a nk ment or additions to drainfield. Contact the City Inspector
-at next pumpout. it tans nave not been Pumped out within immediately.Repairs must be completed within 90 days.
the last three years,t ey should be pumped out now. ❑ Drainfield extent and condition unknown.
SITE CHARACTERISTICS:
Limiting Site Factors Potential for System Failure Site Capabilities for
❑ Slope (depends on soil types,water Future Expansion
❑ Soil table,and system condition) Adequate
❑ High water table ❑ Low Fair
❑ Lot size ❑ Medium ❑Poor
❑ Lake,wetland,or stream ❑ High ❑ Inadequate
❑ Drainage .System is causing visible
surface discharge.
COMMENTS: � L.f
i
s 3-91
ze-
Date of Inspection Septic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that
this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy
of the system under current conditions based on the available information.
This report must be kept on the premises with system location and pumping records.
WHITE COPY/Inspector's File GOLD COPY/Homeowner