HomeMy WebLinkAbout2001-P04676 - mechanical PERMIT
0ITY OF ORONO Permit Number:
2750 Kelley Parkway- PO Box 66 P04676
Crystal Bay, Minnesota 55323 Permit Type: Mechanical Permits
(952) 249-4600 Date Issued: 11/29/2001
SITE ADDRESS: 320 Wakefield Rd
Wayzata,MN 55391
PID: 36-118-23-31-0014
DESCRIPTION:
Proposed Use: Residential
Permit Class: General
Permit Type: Mechanical Permits Permit Sub-type(s): Heating Systems
DETAILS:
Approved per resolution#:
Separate permits required:
NOTICES/REMARKS:
FEE SUMMARY: Permit Fee: $ 35.00 Valuation: $ 2,139.00
State Surcharge Fee: $ 1.07
Misc.Fee: $ 1.50
TOTAL FEE: $37.57
APPLICANT: Differ Inc.&Ditter Properties OWNER: Mr.&Mrs.Botos
820 Tower Drive 320 Wakefield Rd
Medina,MN 55340 Wayzata MN 55391
THE UNDERSIGNED HEREBY REQUESTS PERMISSION TO MAKE THE REAL IMPROVEMENTS SPECIFIED
AND AGREES TO DO ALL WORK IN STRICT COMPLIANCE WITH ALL CITY OF ORONO ORDINANCES AND STATE OF
MINNESOTA BUILDING CODE REQUIREMENTS.
144
4
W lim wool
APIkICANT PERMITEE SIGNATURE AEDBYSIGNATURE
Conies: 1-File(Siznitures Required). 1-ADDlicant, 1-Month1y Reports. 1-Assessin¢. 1-Finance Page 1
3'Zr�
CITY OF ORONO APPLICATION FOR MECHANICAL PERMIT
Box 66 (2750 Kelley Parkway)
Crystal Bay, MN 55323
GENERAL INFOR-NIATION Uul
1. You may apply for mechanical permits by mail or in person at the City offices. Applications will be
reviewed and a permit will be issued within 2 working days. Q1 I Y Ur URO
2. Permit cards will be sent by return mail after a review is completed. PERMITS ARE NOT VANUNTIL
YOU RECEIVE A PERMIT. WORK MUST NOT BEGIN UNTIL THE PERMIT CARD IS POSTED ON
THE JOB SITE.
3. Mechanical Designs - Complete calculations, details and specifications are required for each heating,
ventilation, humidification-dehumidification, and air conditioning installation including heat loss/heat gain
calculation, design temperatures, equipment ratings and identification as to type, manufacturer and model.
Data shall be presented on form provided. Identification of and specifications for water heating equipment
shall also be provided.
4. When any new construction or remodeling is involved, a separate building permit must be obtained.
5. All work must be done in accordance with the Uniform Mechanical Code/State Building Code requirements.
6. All work must be inspected (rough-in and final). Call 249-4600. 24-hour notice required.
7. House Heating Test Record must be submitted before final.
Instructions Complete all items on this application. Compute the permit fee. Sign and date the certification.
INCOMPLETE APPLICATIONS WILL NOT BE PROCESSED. If you have questions, call 249-4600.
Please check one: New Addition Repair 1)( Replace 04-5�kA&v FOWAC,t;
Residential Commercial
JOB SITE: �JZ U VI�Q,�!��i L� �LDA1� Zip: S5
Owner's Name: SU{ Y�I[X jB' pjDS Telephone Number: C1SZ— 7& -A—e2,3
Mailing Address: UD w 116L IUAW City: ply Zip: 55-31/
Contractor's Name: Tele hone Number: 71P3-q'7Q ySs�
Mailing Address: 1- City: Zip: $!-No
SYSTEM DESCRIPTION
HEATING SYSTEMS
Quantity:
Make: n h
Model: 17M3-7s-3
Fuel:
Flue Size:
Input BTUs: 0 O
Output BTUs:
CFM:
COOLING SYSTEMS
Quantity:
Make:
Model:
Tons:
H. Power
FIREPLACES
Gas factory fireplace
Wood burning factory fireplace with flue
Wood Stove
Wood stove with flue
Brand Name Model No.
VENTILATION
No. Kitchen Exhaust ducted recirculating cfm
No. Bath Exhaust (must be ducted outside) cfm
No. Other Fans: Locations cfm
FUEL STORAGE (MUST BE APPROVED BY FIRE MARSHAL)
Installation .Removal
Fuel oil: gallons underground inside outside
LP Gas: gallons
Other Gas opening
PERMIT FEE CALCULATION
1. 1.25% of Contract Price* or Minimum Fee ($35.00)
2113q,V0 x .0125 $ .�
(contract price)
2. State Surcharge. ** Add the State Building Code Division
Surcharge to each permit. Z(3q1V0 x .0005 $
or $.50, whichever is greater (contract price)
3. Postage and Handling (Only mail-in applications) $ 1.50
4. TOTAL PERMIT FEE (Add lines 1-3 above) $ 7j1,61A—
* CONTRACT PRICE or JOB COST means the actual or estimated dollar amount charged for the permitted
work including materials, labor, profit, and other fixed costs. It is the amount to be charged to the customer
for the work done. If any material, equipment, labor, or installation are furnished by the owner, tenant or
any other party the reasonable market value of such items must be added to the estimated cost or contract
price for permit fee purposes. In the event that there is a dispute on the amount of the job cost, the City may
request the submission of a signed copy of the actual contract.
** The STATE SURCHARGE is .0005 of the contract price under$1,000,000 or $.50 - whichever is greater.
For valuations over $1,000,000 call the Department of Inspectional Services for the price.
The undersigned hereby applies to the City for issuance of a Mechanical Permit, agrees to do all
work in strict accordance with the ordinances of the City and the regulations of the Minnesota
State Building Code, and certifies that all statements made on this application are complete, true
and correct.
Applicant's Signature: / 1 Date:
Approved By: Date:
IL
BOTOS
HVAC LOAD ANALYSIS
for
CATHRINE BOTOS
320 WAKEFIELD RD
WAYZATA, M N
wait,-
RVRI
MOULS
SEWS
RoDMIAL
mKHVMAV
WAC LOADS
Prepared By:
Doug Bjork
Ditter Inc.,Cooling and Heating
820 Tower Drive
Medina,MN.55340
(612)478-9558
11-27-2001
R
• RHVAC-Residential&Light Commercial HVAC Loads Program Elite Software Development,Inc.
Ditter,Inc. BOTOS
Hamel,'MN 55340-9691 11-27-2001 Page 2
System#1 Summary Loads
Component Area Sen. Lat. Sen. Total
Description Quan Loss Gain Gain Gain
3E Window Double Pane Low Emit TIM Frame 482 17,693 0 16,630 16,630
8M Glass Door Double Clear Glass Wood Frame 56 2,839 0 4,032 4,032
11D Door Metal Polystyrene Core&Storm 21 612 0 157 157
12H Wall R-19 + 1/2" Gypsum Board(R-0.5) 4,857 26,810 0 6,877 6,877
16H Ceiling R-38 Insulation 1,894 4,530 0 2,167 2,167
20J Floor Over Open Crawl Carpet+ R-30 154 496 0 81 81
21A Basemt Floor 2'or More Below Grade 1,740 3,842 0 0 0 !i
Subtotals for structure: 9,204 56,822 0 29,944 29,944
Active People: 8 0 1,840 2,400 4,240
Inactive People: 0 0 0 0 0
Appliances: 0 0 0 1,200 1,200
Lighting: 0 0 0
Ductwork: 0 0 0 0 0
Infiltration: Winter CFM: 323.5, Summer CFM: 242.6 559 31,761 5,761 5,178 10,939
Ventilation: Winter CFM: 25.0, Summer CFM: 25.0 0 2,455 594 534 1,127
Sensible Gain Total: 39,256
Temperature Swing Multiplier: X1.00
System Load Totals: 91,038 8,195 39,256 47,450 1
Check Figures
_ I
Supply CFM: 1,814 CFM per square foot: 0.958
Square feet of room area: 1,894 Square feet per ton: 445.81
System Loads - --- -- ---- -
Total heating required with outside air: 91,038 Btuh 91.038 MBH
Total sensible gain: 39,256 Btuh 83 %
Total latent gain: 8,195 Btuh 17 %
Total cooling required with outside air: 47,450 Btuh 3.954 Tons (based on sensible+ latent)
4.248 Tons(based on 77% sensible capacity)
i
Notes - ------- -- - �
Calculations are based on 7th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
I II
I
i
i
i
Tuesday,November 27,2001
DATE TIME
CITY OF ORONO CALLED IN
INSPECTION T SCHEDULED
PERMIT NO. / ' 9 7 61:2 COMPLETED
ADDRESS
OWNER GATR.
TELEPHONE NO. �J 7(1�2 g�OpZ
DESCRIPTION
44 01 FOOTING 11 MECHANICAL RI 18 EXCAV/GRADING/FILLING
Q 02 FRAMING 3 MECHANICAL FINAL 19 LAKESHORE/WETLANDS
ti 03 INSULATION 2 /25 WOOD BURNER/FIREPLACE 34 TREE REMOVAL
Z04 WALL BD. 12 WATER HOOK-UP 17 SITE INSPECTION
Q 05 FINAL 14 SEWER HOOK-UP 06 PROGRESS
07 DEMO-SITE 27 SEPTIC MAINT. 21 COMPLAINT
J 07 DEMO-FINAL 15 SEPTIC INSTALL. 22 FOLLOW-UP
? 09 PLUMBING RI 23 SEPTIC FINAL 35 HARD COVER REMOVAL
v 10 PLUMBING FINAL 36 FOUNDATION/REMOVAL
OWNER/CONTRACTOR TO MEET YOU: YES NO
COMMENTS:
W
CL
J
O
cc
O
W
W
cc
Q
Z
W
W
CC
L1 ORKSATISFACTORY:PROCEED ROJECTCOMPLETE
W c❑vCORRECT WORK&PROCEED 11 ISSUE CERTIFICATE OF OCCUPANCY
CO ❑CORRECT WORK,CALL FOR REINSPECTION TEMPORARY
C.) BEFORECOVERING PERMANENT
❑CORRECT UNSAFE CONDITION WITHIN HOURS. ❑ PHOTO TAKEN
INSPECTOR WILL RETURN
❑STOP ORDER POSTED.CALL INSPECTOR
❑CITATION ISSUED
❑INSPECTION REQUIRED.CALL TO ARRANGE ACCESS.
Call for the next inspection 24 hours in advance. (952) 249-4600
Owner/Cont�raa or on site:
Inspector zz, 4:: z—e4�2 o-,
White Copy/Inspector's File Canary Copy/Site Notice