Loading...
HomeMy WebLinkAbout2001-P04676 - mechanical PERMIT 0ITY OF ORONO Permit Number: 2750 Kelley Parkway- PO Box 66 P04676 Crystal Bay, Minnesota 55323 Permit Type: Mechanical Permits (952) 249-4600 Date Issued: 11/29/2001 SITE ADDRESS: 320 Wakefield Rd Wayzata,MN 55391 PID: 36-118-23-31-0014 DESCRIPTION: Proposed Use: Residential Permit Class: General Permit Type: Mechanical Permits Permit Sub-type(s): Heating Systems DETAILS: Approved per resolution#: Separate permits required: NOTICES/REMARKS: FEE SUMMARY: Permit Fee: $ 35.00 Valuation: $ 2,139.00 State Surcharge Fee: $ 1.07 Misc.Fee: $ 1.50 TOTAL FEE: $37.57 APPLICANT: Differ Inc.&Ditter Properties OWNER: Mr.&Mrs.Botos 820 Tower Drive 320 Wakefield Rd Medina,MN 55340 Wayzata MN 55391 THE UNDERSIGNED HEREBY REQUESTS PERMISSION TO MAKE THE REAL IMPROVEMENTS SPECIFIED AND AGREES TO DO ALL WORK IN STRICT COMPLIANCE WITH ALL CITY OF ORONO ORDINANCES AND STATE OF MINNESOTA BUILDING CODE REQUIREMENTS. 144 4 W lim wool APIkICANT PERMITEE SIGNATURE AEDBYSIGNATURE Conies: 1-File(Siznitures Required). 1-ADDlicant, 1-Month1y Reports. 1-Assessin¢. 1-Finance Page 1 3'Zr� CITY OF ORONO APPLICATION FOR MECHANICAL PERMIT Box 66 (2750 Kelley Parkway) Crystal Bay, MN 55323 GENERAL INFOR-NIATION Uul 1. You may apply for mechanical permits by mail or in person at the City offices. Applications will be reviewed and a permit will be issued within 2 working days. Q1 I Y Ur URO 2. Permit cards will be sent by return mail after a review is completed. PERMITS ARE NOT VANUNTIL YOU RECEIVE A PERMIT. WORK MUST NOT BEGIN UNTIL THE PERMIT CARD IS POSTED ON THE JOB SITE. 3. Mechanical Designs - Complete calculations, details and specifications are required for each heating, ventilation, humidification-dehumidification, and air conditioning installation including heat loss/heat gain calculation, design temperatures, equipment ratings and identification as to type, manufacturer and model. Data shall be presented on form provided. Identification of and specifications for water heating equipment shall also be provided. 4. When any new construction or remodeling is involved, a separate building permit must be obtained. 5. All work must be done in accordance with the Uniform Mechanical Code/State Building Code requirements. 6. All work must be inspected (rough-in and final). Call 249-4600. 24-hour notice required. 7. House Heating Test Record must be submitted before final. Instructions Complete all items on this application. Compute the permit fee. Sign and date the certification. INCOMPLETE APPLICATIONS WILL NOT BE PROCESSED. If you have questions, call 249-4600. Please check one: New Addition Repair 1)( Replace 04-5�kA&v FOWAC,t; Residential Commercial JOB SITE: �JZ U VI�Q,�!��i L� �LDA1� Zip: S5 Owner's Name: SU{ Y�I[X jB' pjDS Telephone Number: C1SZ— 7& -A—e2,3 Mailing Address: UD w 116L IUAW City: ply Zip: 55-31/ Contractor's Name: Tele hone Number: 71P3-q'7Q ySs� Mailing Address: 1- City: Zip: $!-No SYSTEM DESCRIPTION HEATING SYSTEMS Quantity: Make: n h Model: 17M3-7s-3 Fuel: Flue Size: Input BTUs: 0 O Output BTUs: CFM: COOLING SYSTEMS Quantity: Make: Model: Tons: H. Power FIREPLACES Gas factory fireplace Wood burning factory fireplace with flue Wood Stove Wood stove with flue Brand Name Model No. VENTILATION No. Kitchen Exhaust ducted recirculating cfm No. Bath Exhaust (must be ducted outside) cfm No. Other Fans: Locations cfm FUEL STORAGE (MUST BE APPROVED BY FIRE MARSHAL) Installation .Removal Fuel oil: gallons underground inside outside LP Gas: gallons Other Gas opening PERMIT FEE CALCULATION 1. 1.25% of Contract Price* or Minimum Fee ($35.00) 2113q,V0 x .0125 $ .� (contract price) 2. State Surcharge. ** Add the State Building Code Division Surcharge to each permit. Z(3q1V0 x .0005 $ or $.50, whichever is greater (contract price) 3. Postage and Handling (Only mail-in applications) $ 1.50 4. TOTAL PERMIT FEE (Add lines 1-3 above) $ 7j1,61A— * CONTRACT PRICE or JOB COST means the actual or estimated dollar amount charged for the permitted work including materials, labor, profit, and other fixed costs. It is the amount to be charged to the customer for the work done. If any material, equipment, labor, or installation are furnished by the owner, tenant or any other party the reasonable market value of such items must be added to the estimated cost or contract price for permit fee purposes. In the event that there is a dispute on the amount of the job cost, the City may request the submission of a signed copy of the actual contract. ** The STATE SURCHARGE is .0005 of the contract price under$1,000,000 or $.50 - whichever is greater. For valuations over $1,000,000 call the Department of Inspectional Services for the price. The undersigned hereby applies to the City for issuance of a Mechanical Permit, agrees to do all work in strict accordance with the ordinances of the City and the regulations of the Minnesota State Building Code, and certifies that all statements made on this application are complete, true and correct. Applicant's Signature: / 1 Date: Approved By: Date: IL BOTOS HVAC LOAD ANALYSIS for CATHRINE BOTOS 320 WAKEFIELD RD WAYZATA, M N wait,- RVRI MOULS SEWS RoDMIAL mKHVMAV WAC LOADS Prepared By: Doug Bjork Ditter Inc.,Cooling and Heating 820 Tower Drive Medina,MN.55340 (612)478-9558 11-27-2001 R • RHVAC-Residential&Light Commercial HVAC Loads Program Elite Software Development,Inc. Ditter,Inc. BOTOS Hamel,'MN 55340-9691 11-27-2001 Page 2 System#1 Summary Loads Component Area Sen. Lat. Sen. Total Description Quan Loss Gain Gain Gain 3E Window Double Pane Low Emit TIM Frame 482 17,693 0 16,630 16,630 8M Glass Door Double Clear Glass Wood Frame 56 2,839 0 4,032 4,032 11D Door Metal Polystyrene Core&Storm 21 612 0 157 157 12H Wall R-19 + 1/2" Gypsum Board(R-0.5) 4,857 26,810 0 6,877 6,877 16H Ceiling R-38 Insulation 1,894 4,530 0 2,167 2,167 20J Floor Over Open Crawl Carpet+ R-30 154 496 0 81 81 21A Basemt Floor 2'or More Below Grade 1,740 3,842 0 0 0 !i Subtotals for structure: 9,204 56,822 0 29,944 29,944 Active People: 8 0 1,840 2,400 4,240 Inactive People: 0 0 0 0 0 Appliances: 0 0 0 1,200 1,200 Lighting: 0 0 0 Ductwork: 0 0 0 0 0 Infiltration: Winter CFM: 323.5, Summer CFM: 242.6 559 31,761 5,761 5,178 10,939 Ventilation: Winter CFM: 25.0, Summer CFM: 25.0 0 2,455 594 534 1,127 Sensible Gain Total: 39,256 Temperature Swing Multiplier: X1.00 System Load Totals: 91,038 8,195 39,256 47,450 1 Check Figures _ I Supply CFM: 1,814 CFM per square foot: 0.958 Square feet of room area: 1,894 Square feet per ton: 445.81 System Loads - --- -- ---- - Total heating required with outside air: 91,038 Btuh 91.038 MBH Total sensible gain: 39,256 Btuh 83 % Total latent gain: 8,195 Btuh 17 % Total cooling required with outside air: 47,450 Btuh 3.954 Tons (based on sensible+ latent) 4.248 Tons(based on 77% sensible capacity) i Notes - ------- -- - � Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. I II I i i i Tuesday,November 27,2001 DATE TIME CITY OF ORONO CALLED IN INSPECTION T SCHEDULED PERMIT NO. / ' 9 7 61:2 COMPLETED ADDRESS OWNER GATR. TELEPHONE NO. �J 7(1�2 g�OpZ DESCRIPTION 44 01 FOOTING 11 MECHANICAL RI 18 EXCAV/GRADING/FILLING Q 02 FRAMING 3 MECHANICAL FINAL 19 LAKESHORE/WETLANDS ti 03 INSULATION 2 /25 WOOD BURNER/FIREPLACE 34 TREE REMOVAL Z04 WALL BD. 12 WATER HOOK-UP 17 SITE INSPECTION Q 05 FINAL 14 SEWER HOOK-UP 06 PROGRESS 07 DEMO-SITE 27 SEPTIC MAINT. 21 COMPLAINT J 07 DEMO-FINAL 15 SEPTIC INSTALL. 22 FOLLOW-UP ? 09 PLUMBING RI 23 SEPTIC FINAL 35 HARD COVER REMOVAL v 10 PLUMBING FINAL 36 FOUNDATION/REMOVAL OWNER/CONTRACTOR TO MEET YOU: YES NO COMMENTS: W CL J O cc O W W cc Q Z W W CC L1 ORKSATISFACTORY:PROCEED ROJECTCOMPLETE W c❑vCORRECT WORK&PROCEED 11 ISSUE CERTIFICATE OF OCCUPANCY CO ❑CORRECT WORK,CALL FOR REINSPECTION TEMPORARY C.) BEFORECOVERING PERMANENT ❑CORRECT UNSAFE CONDITION WITHIN HOURS. ❑ PHOTO TAKEN INSPECTOR WILL RETURN ❑STOP ORDER POSTED.CALL INSPECTOR ❑CITATION ISSUED ❑INSPECTION REQUIRED.CALL TO ARRANGE ACCESS. Call for the next inspection 24 hours in advance. (952) 249-4600 Owner/Cont�raa or on site: Inspector zz, 4:: z—e4�2 o-, White Copy/Inspector's File Canary Copy/Site Notice