HomeMy WebLinkAbout2002-P05337 - mechanical CITY OF ORONO PERMIT
2750 Kelley Parkway - PO Box 66 Permit Number: P05337
Crystal Bay, Minnesota 55323 Permit Type: Mechanical Permits
(952) 249-4600 Date Issued: 6/212002
SITE ADDRESS: 280 Wakefield Rd
Wayzata,MN 55391
PID: 36-118-23-31-0013
DESCRIPTION:
Proposed Use: Residential
Permit Class: General
Permit Type: Mechanical Permits Permit Sub-type(s): Multiple Mechanical Items
DETAILS:
Approved per resolution#:
Separate permits required:
NOTICES/REMARKS:
FEE SUMMARY: Permit Fee: $ 78.25 Valuation: $ 6,260.00
State Surcharge Fee: $ 3.13
Misc. Fee: $ 1.50
TOTAL FEE: $ 82,88
APPLICANT: Ditter Inc. &Ditter Properties OWNER: Thomas&Katherine Batina
820 Tower Drive 280 Wakefield Rd
Medina,MN 55340 Wayzata,MN 55391
THE UNDERSIGNED HEREBY REQUESTS PERMISSION TO MAKE THE REAL IMPROVEMENTS SPECIFIED
AND AGREES TO DO ALL WORK IN STRICT COMPLIANCE WITH ALL CITY OF ORONO ORDINANCES AND STATE OF
MINNESOTA BUILDING CODE REQUIREMENTS.
Z22ad' ,,�
APPL CANT PERMITEE SIGNATURE OVID BY SIGNATURE
Copies: 1-File(Siznitures Reauired), 1-Applicant, 1-Monthly Renorts, 1-Assessing, 1-Finance Page 1
CITY OF ORONO APPLICATION FOR MECHANICAL PERMIT Pagel of 3
' CITY OF ORONO APPLICATION FOR MECHANICAL PERMIT 9"b
Box 66 (2750 Kelley Parkway)
Crystal Bay,MN 55323
GENERAL INFORMATION
1. You may apply for mechanical permits by mail or in person at the City offices. Applications will be reviewed and a
permit will be issued within two working days.
2. Permit cards will be sent by return mail after a review is completed. PERMITS ARE NOT VALID UNTIL YOU
RECEIVE A PERMIT. WORK MUST NOT BEGIN UNTIL THE PERMIT CARD IS POSTED ON THE JOB SITE.
3. Mechanical Designs-Complete calculations,details and specifications are required for each heating, ventilation,
um idification-dehum idification, and air conditioning installation including heat loss/heat gain calculation, design
temperatures, equipment ratings and identification as to type, manufacturer and model. Data shall be presented on form
provided. Identification of and specifications for water heating equipment shall also be provided.
4. When any new construction or remodeling is involved, a separate building permit must be obtained.
5. All work must be done in accordance with the Uniform Mechanical Code/State Building Code requirements.
6. All work must be inspected(rough-in and final). Call (952)249-4600. 24-hour notice required.
7. House Heating Test Record must be submitted before final.
Instructions
Complete all items on this application. Compute the permit fee. Sign and date the certification. INCOMPLETE
APPLICATIONS WILL NOT BE PROCESSED. If you have questions, call (952) 249-4600.
Please check one: New Addition Repair Replace Residential Commercial
JOB SITE: L 0alkt 1 Q (A40ad Zip: 5�-1
Owner's Name: KLV tIrit nw Phone Number: q,5-2--q � — l�
Mailing Address: 53(br-L— City: /LewM-f-c— Zip:
Contractor's Name: �!'1C Phone Number:
Mailing Address: 5 20 T-cl.ty— / City: d6 GSL( . Zip: 253q IZ
SYSTEM DESCRIPTION
HEATING SYSTEMS
Quantity:
Make: Q 1i`r /`L r7ol 0/
Model: (J
Model: W,W)
Fuel:
Flue Size: A
CID
Input BTUs: too 'S U
Output BTUs:
CFM:
http://www.ci.orono.mn.us/mechanical%20permit.html 6/17/2002
CITY OF ORONO APPLICATION FOR MECHANICAL PERMIT Page 2 of 3
COOLING SYSTEMS
Quantity:
Make:
Model:
Tons: 2 Z-
H.Power
FIREPLACES
Gas factory fireplace
Wood burning factory fireplace with flue
Wood Stove
Wood stove with flue
Brand Name Model No.
VENTILATION
No. Kitchen Exhaust duct recalculating cfm
No. Bath Exhaust(must have duct outside) cfm
No. Other Fans: Locations cfm
FUEL STORAGE(MUST BE APPROVED BY FIRE MARSHAL)
Installation or Removal
Fuel oil: gallons underground inside outside
LP Gas: gallons
Other Gas opening
PERMIT FEE CALCULATION(S)
2002 State Statute Yes This Section Applies
The replacement of a Residential fixture or appliance that meets all three of the following requirements:
1) Does not require modification to electrical or gas service.
2) Has a total cost of$500.00 or less;excluding the cost of the fixture or appliance:
and
3) Is improved, installed or replaced by the homeowner or licensed contractor.
Skip next section; Cost of Permit $ 15.00
State Surcharge $ .50
Mail-In Fee $ 1.50
If above does not apply, follow guidelines below:
1. Contract Price* is .0125%of job with a Minim/um Fee of($35.00)
x .0125 $
(contract price) (minimum$35.00)
2. State Surcharge. ** Add the State Building Code Division aMinimum Fee of($.50)
CPu�0 x.0005 $ J
http://www.ci.orono.mn.us/mechanical%20permit.html 6/17/2002
CITY OF ORONO APPLICATION FOR MECHANICAL PERMIT Page 3 of 3
(contract price) (minimum$.50)
3. Postage and Handling(Only mail-in applications) $ 1.50
4. TOTAL PERMIT FEE(Add lines 1-3 above) $ ZZ -22 —
*CONTRACT PRICE or JOB COST means the actual or estimated dollar amount charged for the permitted work including materials,labor,profit,
and other fixed costs.It is the amount to be charged to the customer for the work done.If any material,equipment, labor,or installation is furnished
by the owner,tenant or any other party the reasonable market value of such items must be added to the estimated cost or contract price for permit fee
purposes.In the event that there is a dispute on the amount of the job cost,the City may request the submission of a signed copy of the actual
contract.
**The STATE SURCHARGE is.0005 of the contract price under$1,000,000 or$.50-whichever is greater.For valuations over$1,000,000 call the
Department of Inspectional Services for the price.
The undersigned hereby applies to the City for issuance of a Mechanical Permit,agrees to do all work in strict accordance with the ordinances of the
City and the regulations of the Minn ota State Building Code,and certifies that all statements made on this application are complete,true and
correct.
Applicant's Signature: r Date:
Approved By: Date:
http://www.ci.orono.mn.us/mechanical%20permit.html 6/17/2002
PATINA
HVAC LOAD ANALYSIS
for
Kathrine Patina
280 Wakefield Rd
Wayzata, Mn
RHVACFUDINM
WAC LoADs
Prepared By:
Doug Bjork
Diner Cooling and Heating
820 Tower Drive
Medina, MN. 55340
(763)-478-8558
RHVAC-Residential;& Light Commercial HVAC Loads Elite Software Development, Inc.
Program
Detter. Inc Patinai
I
Project: Patina Company: Differ Cooling and Heating
Client: Kathrine Patina Representative: Doug Bjork
Address: 280 Wakefield Rd Address: 820 Tower Drive
City: Wayzata,Mn City: Medina,MN.55340
Phone: Phone: (763)-478-8558
Fax: Fax: (763)-478-2426
Comment:
Design Data
Project Name: Patina
Reference City: Minneapolis,Minnesota
Daily Temperature Range: Medium
Latitude: 44 Degrees
Elevation: 834 Feet
Elevation Sensible Adj.Factor: 1.000
Elevation Total Adj.Factor: 1.000
Outdoor Outdoor Indoor Indoor Grains
Dry Bulb Wet Bulb Rel.Hum. Dry Bulb Difference
Winter: -20 N/A WA 72 WA
Summer. 95 75 50% 75 36
Check Figures —
Total Building Supply CFM: 1000 CFM per square foot: 0.49
Square feet of room area: 2,040 Square feet per ton: 396.785
Building Loads
Total heating required with outside air: 136,509 Btuh 136.509 MBH
Total sensible gain: 47,506 Btuh 78 %
Total latent gain: 13,657 Btuh 22 %
Total cooling required with outside air: 61,163 Btuh 5.097 Tons(based on sensible+latent)
5.141 Tons(based on 77%sensible capacity)
Notes
Calculations are based on 7th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
I
I
Tuesday,June 18,2002
RHVAC-Residential&Light Commercial HVAC Loads Program Elite Software Development,Inc.
Differ,Inc. Patina
Hamel,MN 55340-9691 Page 3
Total Building Summary Loads
Component Area Sen. Lat. Sen. Total
Description Quan Loss Gain Gain Gain
3A Window Double Pane Clear Glass Wood Frame 468 23,725 0 20,700 20,700
8M Glass Door Double Clear Glass Wood Frame 42 2,129 0 1,932 1,932
10F Door Wood Solid Core&Metal Storm 42 1,236 0 318 318
12D Wall R-11 + 1/2"Asphlt Board(R-1.3) 4,336 31,913 0 8,186 8,186
16H Ceiling R-38 Insulation 2,040 4,880 0 2,334 2,334
21A Basemt Floor 2'or More Below Grade 2,040 4,504 0 0 0
Subtotals for structure: 8,968 68,387 0 33,470 33,470
Active People: 6 0 1,380 1,800 3,180
Inactive People: 0 0 0 0 0
Appliances: 0 0 0 1,200 1,200
Lighting: 0 0 0
Ductwork: 0 0 0 0 0
Infiltration:Winter CFM: 618.8, Summer CFM: 442.0 552 60,758 10,496 9,435 19,931
Ventilation:Winter CFM: 75.0, Summer CFM: 75.0 0 7,364 1,781 1,601 3,382
Sensible Gain Total: 47,506
Temperature Swing Multiplier: X1.00
Building Load Totals: 136,50 13,657 47,506 61,163
9
Check Figures
Total Building Supply CFM: 1000 CFM per square foot: 0.49
Square feet of room area: 2,040 Square feet per ton: 396.785
Building Loads
Total heating required with outside air: 136,509 Btuh 136.509 MBH
Total sensible gain: 47,506 Btuh 78 %
Total latent gain: 13,657 Btuh 22 %
Total cooling required with outside air: 61,163 Btuh 5.097 Tons(based on sensible+ latent)
5.141 Tons(based on 77%sensible capacity)
Notes
Calculations are based on 7th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
I
Tuesday,June 18,2002