HomeMy WebLinkAbout2002-P05337 - mechanical CITY OF ORONO PERMIT 2750 Kelley Parkway - PO Box 66 Permit Number: P05337 Crystal Bay, Minnesota 55323 Permit Type: Mechanical Permits (952) 249-4600 Date Issued: 6/212002 SITE ADDRESS: 280 Wakefield Rd Wayzata,MN 55391 PID: 36-118-23-31-0013 DESCRIPTION: Proposed Use: Residential Permit Class: General Permit Type: Mechanical Permits Permit Sub-type(s): Multiple Mechanical Items DETAILS: Approved per resolution#: Separate permits required: NOTICES/REMARKS: FEE SUMMARY: Permit Fee: $ 78.25 Valuation: $ 6,260.00 State Surcharge Fee: $ 3.13 Misc. Fee: $ 1.50 TOTAL FEE: $ 82,88 APPLICANT: Ditter Inc. &Ditter Properties OWNER: Thomas&Katherine Batina 820 Tower Drive 280 Wakefield Rd Medina,MN 55340 Wayzata,MN 55391 THE UNDERSIGNED HEREBY REQUESTS PERMISSION TO MAKE THE REAL IMPROVEMENTS SPECIFIED AND AGREES TO DO ALL WORK IN STRICT COMPLIANCE WITH ALL CITY OF ORONO ORDINANCES AND STATE OF MINNESOTA BUILDING CODE REQUIREMENTS. Z22ad' ,,� APPL CANT PERMITEE SIGNATURE OVID BY SIGNATURE Copies: 1-File(Siznitures Reauired), 1-Applicant, 1-Monthly Renorts, 1-Assessing, 1-Finance Page 1 CITY OF ORONO APPLICATION FOR MECHANICAL PERMIT Pagel of 3 ' CITY OF ORONO APPLICATION FOR MECHANICAL PERMIT 9"b Box 66 (2750 Kelley Parkway) Crystal Bay,MN 55323 GENERAL INFORMATION 1. You may apply for mechanical permits by mail or in person at the City offices. Applications will be reviewed and a permit will be issued within two working days. 2. Permit cards will be sent by return mail after a review is completed. PERMITS ARE NOT VALID UNTIL YOU RECEIVE A PERMIT. WORK MUST NOT BEGIN UNTIL THE PERMIT CARD IS POSTED ON THE JOB SITE. 3. Mechanical Designs-Complete calculations,details and specifications are required for each heating, ventilation, um idification-dehum idification, and air conditioning installation including heat loss/heat gain calculation, design temperatures, equipment ratings and identification as to type, manufacturer and model. Data shall be presented on form provided. Identification of and specifications for water heating equipment shall also be provided. 4. When any new construction or remodeling is involved, a separate building permit must be obtained. 5. All work must be done in accordance with the Uniform Mechanical Code/State Building Code requirements. 6. All work must be inspected(rough-in and final). Call (952)249-4600. 24-hour notice required. 7. House Heating Test Record must be submitted before final. Instructions Complete all items on this application. Compute the permit fee. Sign and date the certification. INCOMPLETE APPLICATIONS WILL NOT BE PROCESSED. If you have questions, call (952) 249-4600. Please check one: New Addition Repair Replace Residential Commercial JOB SITE: L 0alkt 1 Q (A40ad Zip: 5�-1 Owner's Name: KLV tIrit nw Phone Number: q,5-2--q � — l� Mailing Address: 53(br-L— City: /LewM-f-c— Zip: Contractor's Name: �!'1C Phone Number: Mailing Address: 5 20 T-cl.ty— / City: d6 GSL( . Zip: 253q IZ SYSTEM DESCRIPTION HEATING SYSTEMS Quantity: Make: Q 1i`r /`L r7ol 0/ Model: (J Model: W,W) Fuel: Flue Size: A CID Input BTUs: too 'S U Output BTUs: CFM: http://www.ci.orono.mn.us/mechanical%20permit.html 6/17/2002 CITY OF ORONO APPLICATION FOR MECHANICAL PERMIT Page 2 of 3 COOLING SYSTEMS Quantity: Make: Model: Tons: 2 Z- H.Power FIREPLACES Gas factory fireplace Wood burning factory fireplace with flue Wood Stove Wood stove with flue Brand Name Model No. VENTILATION No. Kitchen Exhaust duct recalculating cfm No. Bath Exhaust(must have duct outside) cfm No. Other Fans: Locations cfm FUEL STORAGE(MUST BE APPROVED BY FIRE MARSHAL) Installation or Removal Fuel oil: gallons underground inside outside LP Gas: gallons Other Gas opening PERMIT FEE CALCULATION(S) 2002 State Statute Yes This Section Applies The replacement of a Residential fixture or appliance that meets all three of the following requirements: 1) Does not require modification to electrical or gas service. 2) Has a total cost of$500.00 or less;excluding the cost of the fixture or appliance: and 3) Is improved, installed or replaced by the homeowner or licensed contractor. Skip next section; Cost of Permit $ 15.00 State Surcharge $ .50 Mail-In Fee $ 1.50 If above does not apply, follow guidelines below: 1. Contract Price* is .0125%of job with a Minim/um Fee of($35.00) x .0125 $ (contract price) (minimum$35.00) 2. State Surcharge. ** Add the State Building Code Division aMinimum Fee of($.50) CPu�0 x.0005 $ J http://www.ci.orono.mn.us/mechanical%20permit.html 6/17/2002 CITY OF ORONO APPLICATION FOR MECHANICAL PERMIT Page 3 of 3 (contract price) (minimum$.50) 3. Postage and Handling(Only mail-in applications) $ 1.50 4. TOTAL PERMIT FEE(Add lines 1-3 above) $ ZZ -22 — *CONTRACT PRICE or JOB COST means the actual or estimated dollar amount charged for the permitted work including materials,labor,profit, and other fixed costs.It is the amount to be charged to the customer for the work done.If any material,equipment, labor,or installation is furnished by the owner,tenant or any other party the reasonable market value of such items must be added to the estimated cost or contract price for permit fee purposes.In the event that there is a dispute on the amount of the job cost,the City may request the submission of a signed copy of the actual contract. **The STATE SURCHARGE is.0005 of the contract price under$1,000,000 or$.50-whichever is greater.For valuations over$1,000,000 call the Department of Inspectional Services for the price. The undersigned hereby applies to the City for issuance of a Mechanical Permit,agrees to do all work in strict accordance with the ordinances of the City and the regulations of the Minn ota State Building Code,and certifies that all statements made on this application are complete,true and correct. Applicant's Signature: r Date: Approved By: Date: http://www.ci.orono.mn.us/mechanical%20permit.html 6/17/2002 PATINA HVAC LOAD ANALYSIS for Kathrine Patina 280 Wakefield Rd Wayzata, Mn RHVACFUDINM WAC LoADs Prepared By: Doug Bjork Diner Cooling and Heating 820 Tower Drive Medina, MN. 55340 (763)-478-8558 RHVAC-Residential;& Light Commercial HVAC Loads Elite Software Development, Inc. Program Detter. Inc Patinai I Project: Patina Company: Differ Cooling and Heating Client: Kathrine Patina Representative: Doug Bjork Address: 280 Wakefield Rd Address: 820 Tower Drive City: Wayzata,Mn City: Medina,MN.55340 Phone: Phone: (763)-478-8558 Fax: Fax: (763)-478-2426 Comment: Design Data Project Name: Patina Reference City: Minneapolis,Minnesota Daily Temperature Range: Medium Latitude: 44 Degrees Elevation: 834 Feet Elevation Sensible Adj.Factor: 1.000 Elevation Total Adj.Factor: 1.000 Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum. Dry Bulb Difference Winter: -20 N/A WA 72 WA Summer. 95 75 50% 75 36 Check Figures — Total Building Supply CFM: 1000 CFM per square foot: 0.49 Square feet of room area: 2,040 Square feet per ton: 396.785 Building Loads Total heating required with outside air: 136,509 Btuh 136.509 MBH Total sensible gain: 47,506 Btuh 78 % Total latent gain: 13,657 Btuh 22 % Total cooling required with outside air: 61,163 Btuh 5.097 Tons(based on sensible+latent) 5.141 Tons(based on 77%sensible capacity) Notes Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. I I Tuesday,June 18,2002 RHVAC-Residential&Light Commercial HVAC Loads Program Elite Software Development,Inc. Differ,Inc. Patina Hamel,MN 55340-9691 Page 3 Total Building Summary Loads Component Area Sen. Lat. Sen. Total Description Quan Loss Gain Gain Gain 3A Window Double Pane Clear Glass Wood Frame 468 23,725 0 20,700 20,700 8M Glass Door Double Clear Glass Wood Frame 42 2,129 0 1,932 1,932 10F Door Wood Solid Core&Metal Storm 42 1,236 0 318 318 12D Wall R-11 + 1/2"Asphlt Board(R-1.3) 4,336 31,913 0 8,186 8,186 16H Ceiling R-38 Insulation 2,040 4,880 0 2,334 2,334 21A Basemt Floor 2'or More Below Grade 2,040 4,504 0 0 0 Subtotals for structure: 8,968 68,387 0 33,470 33,470 Active People: 6 0 1,380 1,800 3,180 Inactive People: 0 0 0 0 0 Appliances: 0 0 0 1,200 1,200 Lighting: 0 0 0 Ductwork: 0 0 0 0 0 Infiltration:Winter CFM: 618.8, Summer CFM: 442.0 552 60,758 10,496 9,435 19,931 Ventilation:Winter CFM: 75.0, Summer CFM: 75.0 0 7,364 1,781 1,601 3,382 Sensible Gain Total: 47,506 Temperature Swing Multiplier: X1.00 Building Load Totals: 136,50 13,657 47,506 61,163 9 Check Figures Total Building Supply CFM: 1000 CFM per square foot: 0.49 Square feet of room area: 2,040 Square feet per ton: 396.785 Building Loads Total heating required with outside air: 136,509 Btuh 136.509 MBH Total sensible gain: 47,506 Btuh 78 % Total latent gain: 13,657 Btuh 22 % Total cooling required with outside air: 61,163 Btuh 5.097 Tons(based on sensible+ latent) 5.141 Tons(based on 77%sensible capacity) Notes Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. I Tuesday,June 18,2002