HomeMy WebLinkAboutseptic info Minnesota Pollution Compliance Inspection For
Control Agency
Control
Road North Existing Subsurface Sewage Treatment Systems (SST
)
StPauL,MN SS1S5-4194 Doc Type:Compliance and Enforcer nt
Inspection results based on Minnesota Pollution Control Agency(MPCA) For local tracking purposes:
requirements and attached forms—additional local requirements may also appy.
Submit completed form to Local Unit of Government(LUG)and system owner
within 15 days
System Status
System status on date(mm/dd/yyyy): April 20, 2018
® Compliant—Certificate of Compliance ❑ Noncompliant— Notice of Noncomplian e
(Valid for 3 years from report date, unless shorter time (See Upgrade Requirements on page 3.)
frame outlined in Local Ordinance.)
Reason(s)for noncompl lance(check all applicable)
❑ Impact on Public Health (Compliance Component 01)—Imminent threat to public health and safety
❑Other Compliance Conditions(Compliance Component#3)—Imminent threat to public health and safety
❑Tank Integrity(Compliance Component#2)—Failing to protect groundwater
❑Other Compliance Conditions(Compliance Component#3)—Failing to protect groundwater
❑Soil Separation(Compliance Component#4)—Failing to protect groundwater
❑Operating permit/monitoring plan requirements(Compliance Component#5)—Noncompliant
Property Information Parcel ID#or Sec/Twp/Range: PID# 31-118-23-24-0013
Property address: 465 Tumham Road Orono,MN.55359 Reason for inspection: Property Transfer
Property owner. Owner's phone:
or
Owner's representative: Edina Realty attn:Bruce&Sue Wolf Representative phone: 612 270-2220
Local regulatory authority: City of Orono Regulatory authority phone: 952 249-4625
Brief system description: A 1250 gal Septic,a 1000 gal Septic,a 1000 gal Pum (Tanks), &a 50 ft x 100ft Pressure Mound
Comments or recommendations:
See sketch for Configuration:-1 0 ft x 53 ft Rods Bed
Consulted Constuction&AS-BUILT Data from LGU files
Certification
I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No
determination of future system performance has been nor can be made due to unknown conditions during system construction,
possible abuse of the system,Inadequate malntenance, or future water uaage.
Inspector name: Thomas Klanchnik Certification number: R 5945
Business name: Advanced OnSite, Inc. License number: L 2656
Inspector signature: Phone number: 612 232-9737
Necessary or Locally Req red Attachments
® Soil boring logs ®System/As-built drawing ® Forms per local ordinance
®Other information(list): Pumping Data
www.pca.state.mn.us • 651-296-6300 • 800-657-3864 TTY 651-282-5332 or 800-657-3864 • Available in altemative rmats
wq.ww1sts4-31b • 614114 PaSe 1 of 3
Property address: 465 Tumham Road Orono,MN.55359 Inspector initials/Date: I April 20,201
(mm/dd/yyyy)
1. Impact on Public Health—Compliance component#1 of 5
Compliance criteria: Verification method(s):
System discharges sewage to the ❑Yes ®No ®Searched for surface outlet
round surface. ®Searched for seeping in yard/backup in home
System discharges sewage to drain ❑Yes ® No ❑ Excessive ponding in soil system/D-boxes
tile or surface waters. ❑Homeowner testimony(See Comments/Explanation)
System causes sewage backup into ❑Yes ® No ❑"Black soil"above soil dispersal system
dwelling or establishment. 1 ❑ System requires"emergency'pumping
Any"yes"answer above indicates the ❑Performed dye test
system is an imminent threat to public ❑Unable to verify(See Commants/Explanation)
health and safety. ❑Other methods not listed(See Comments/Explanation)
Comments/Explanation:
2. Tank Integrity—Compliance component#2 of 5
Compliance criteria: Verification method(s):
System consists of a seepage pit, ❑Yes ® No ® Probed tank(s)bottom
cesspool,drywell,or leaching pit. ®Examined construction records
Seepage pits meeting 7080.2550 may be ❑ Examined Tank Integrity Form(Attach)
compliant if allowed in local ordinance.
❑Observed liquid level below operating depth
Sewage tank(s)leak below their ❑Yes ® No C[Examined empty(pumped)tanks(s)
designed operating depth.
If yes,which sewage tank(s)leaks: El Probed outside tank(s)for"black soil"
Any "yes"answer above indicates the ❑ Unable to verify(See Comments/Explanation)
system is failing to protect groundwater. [I Other methods not listed(See CommentslExp/anatlon
Comments/Explanation:
Pumped-See attached
3. Other Compliance Conditions—Compliance component#3 of 5
a. Maintenance hole covers are damaged,cracked,unsecured,or appear to be structurally unsound. ❑Yes* ®No ❑Unk iown
b. Other issues(electrical hazards,etc.)to immediately and adversely impact public health or safety. ❑Yes* ®No ❑Unk iown
*System is an imminent threat to public health and safety.
Explain:
c. System is non-protective of groundwater for other conditions as determined by inspector. ❑Yes* ®No
*System is failing to protect groundwaW
Explain:
www.pca.state.mn.us - 651.296-6300 800-657-3864 TTY 651-282-5332 or 800-657-3864 - Available in alternative f Drmats
wq-wwists4-31b - 614114 Pose 2of3
Property address: 465 Tumham Road Orono MN.55359 Inspector initials/Date: 401AZI Aril 20 201
tl (mnVdd/yyyy)
4. Soil Separation—Compliance component#4 of 5
Date of installation: 6/18/2003 ❑ Unknown Verification method(s):
('r"rj1 y) Sal observation does not expire.Previous soil
ShorelandNVellhead protecdonlFood beverage ❑Yes ® No observations by two independent parties are sufficient
lodging? unless site conditions have been altered or local
Compliance criteria: requirements differ.
For systems built prior to April 1, 1996, and ❑Yes ❑No ®Conducted soil observation(s)(Attach boring logs)
not located in Shoreland or Wellhead ❑Two previous verifications(Attach boring logs)
Protection Area or not serving a food,
beverage or lodging establishment: ❑Not applicable(Holding tank(s),no drainfield)
Drainfield has at least a two-foot vertical ❑ Unable to verify(See Comments/Explanation)
separation distance from periodically ❑Other(See CommentsE cplanation)
saturated soil or bedrock.
Non-performance systems built April 1, ®Yes [] No Comments/Explanation:
1996, or later or for non-performance
systems located in Shoreland or Wellhead
Protection Areas or serving a food,
beverage, or lodging establishment.
Drainfield has a three-foot vertical
separation distance from periodically
saturated soil or bedrock.*
"Experimental" "Other', or Performance" ❑Yes ❑ No Indicate depths or elevations
systems built under pre-2008 Rules,Type IV
or V systems built under 2008 Rules(7080. A. Bottom of distribution media T102.0
2350 or 7080.2400 (Advanced Inspector
License required) S. Periodically saturated solUbedroclk 99.0
Drainfield meets the designed vertical C. System separation 36"
separation distance from periodically
saturated soil or bedrock. D. Required compliance separation* 36"
Any "no"answer above indicates the system is *May be reduced up to 15 percent if allowed by Local
failing to protect groundwater. Ordinance.
5. Operating Permit and Nitrogen BMP*—Compliance component#5 of 5 ® Not applicable
Is the system operated under an Operating Permit? ❑Yes ❑No If"yes",A below Is required
Is the system required to employ a Nitrogen BMP? ❑Yes ❑ No If"yes",B below Is required
BMP=Best Management Practice(s)specified in the system design
If the answer to both questions is "no'; this section does not need to be completed.
Compliance criteria
a. Operating Permit number:
Have the Operating Permit requirements been met? []Yes El No
b. Is the required nitrogen BMP in place and properly functioning? 0 Yes No
Any"no"answer indicates Noncompliance.
Upgrade Requirements(Minn.Stat.§115.55)An imminent threat to public health and safety(1TPHS)must be upgraded,replaced,orits use
discontinued within ten months of receipt of this noboe or within a shorter period if required by local ordinance.If the system is failing to prt 4ect
ground water,the system must be upgraded,replaced,or its use discontinued within the time required by local ordinance.If an existing sydem
is not failing as defined in law,and has at least two feet of design soil separation,than the system need not be upgraded,repaired,replact d,or
its use discontinued,notwithstanding any local ordinance that is more strict. This provision does not apply to systems in shoreland areas,
Wellhead Protection Areas,or those used in connection with food,beverage,and lodging establishments as defined in law.
www.pca.state.mn.us - 651-296-6300 800-657-3864 TTY 651-282-5332 or 800-657-3864 - Available in alternativef rmats
wq-wwlsts4-31b • 614114 P03 of 3
r , CA G,
Qg_ :
Y
AR
cwlloelk
Numboaft dw wm moa an watt wet smdmk m owwramm.
dam
sS�ac sad�4ih RAW sts x.-Ad buildings. Fi •
.�!s"far tK. Lsj m%v=d. ) 'Lifesc:.
(DRcm
iex www.depth 4 a=b&m.-Sat soil t� *. '�i_. '��:oc�: z^�d s:an v��ster.
. the mewaw is fill. -
3�MA'! -Cot
� �l.tG�'IZ,L�G;S�tsmt►st•
fI
�^
' r
1
I,
......... -- -_ -
Tank Report
Date: May 25,2018
Elmer I Peterson Co.
5921 Dague Ave.
Delano,MN 55328
Phone 763-972-2420
Fax 763-972-7217
MPCA License#219
Bruce Wolf—Edina Realty
465 Tumham Road
Orono,MN 55356
612-270-2220
Battles. ON OFF
Tank Capacity: 2-1250 Gallon Tanks,1-1000 Gallon Lift Station Per City Records
#of Tanks: 3
Type of Tanks. Concrete
Gallons Pumped: 3000
Manholes to Grade: YES l NO
I
Comments:
On May 25,2018,Elmer J.Peterson Co.uncovered manholes(181 manhole to grade,2nd manhole-2
inches deep and lift station manhole to grade)and pumped tanks. No cracks or water leaking in tanks at
that time.
I
i
3
NOTE:This is only a tank report. This is not a compliance inspection for point of sale nor does it
replace a compliance inspection.
j
I
i
I
i
Property address: 485 Tundham Road Inspector initielsOate: 525! _..
1. Impact on Public Health—Compliance component#1 of 5
Compliance criteria: Verification method(s):
System discharge sewage to the ❑Yes ❑No ❑ Searched for surface outlet
ground surface. ❑ Searched for seeping In yardfiackup In home
— ---�� ❑ Excessive ponding in soft systernJO-boxes
System discharge sewage to drain file I ❑Yes ❑No [:1 Homeowner testimony(See Comrtlerr�Expiarrafion)
or surface waters.._- - _
_ ----__.—. ❑ 'Black sok"above soil diepersal system
System cause sewage backup into ❑Yes ❑No ❑ System recluires•emos ,.y pumping
dweling or establishment. _
_-.— ❑ Performed dye test
Any"yes"answer above indketes the system is ❑ Unable to verify(See ConvrrenftE rpranatlan)
an Imminent Threat to Publk Health and Safety. ❑ Other methods not listed(See comm r&,E rptanaaon)
Comments/Explanation:
2. Tank integrity–Compliance component#2 of 5
Compliance criteria: Verification method(s):
System consists of a seepage pit, ❑Yes ON. ❑ Probed tank(s)bottom
cesspool,drywei,or leaching pit. ` ❑ Examined construction records
Seepage pits meeting 7080.2550 may be ❑ Examined Tank Integrity Foran(Attach)
M a6fowed a�rocs!ardblence. — ___._ ❑ Observed liquid level below operating depth
Sewage tank(s)leak below their ❑Yes ®No ® Examined amply(pumped)tanks(s)
—desig!rsd.gx___ __P......_. _____..._..____...-.---.------ ❑ Probed outside tank(s)for Uedk sac"
If yes,which sewage tank(s)leaks:
Any`yes"answer above indicates the ❑ unable to verily(sae Cd(Serrts&wnertalion)
system is Failing to Protect Groundwater. ❑Outer methods not fisted(sae t:anxrrentslFxpiarwlion)
Comments/Explanation:
On 525/18,Elmer J.Peterson Co.pumped tanks.
3. Other Compliance Conditions—Compliance component#3 of 5
a. McWenarlce hole covers are damaged,cracked,unftcksed,or appear to structurally unsound. ❑vas• ❑No ❑Urkn wn
b. Other issues(ebra"haaards,alk.)to irmwdmt*and adversely impact pubic health or safety. ❑Yes• ❑No ❑Unknown
'Sysunr is an MrrW wtr trireat tlo puW ho Mr and osAW
Explain:
a System is non-protective of ground water for other otxrditiona as determined by inspector ❑Yee• 0 No
'System is Wft tb pvo/eot groun"Wer
Explain:
www.pca.state.mn.us • 651.296-63110 8DD•657.3864 TTY 651.282-5332 or s00-657.38frk Available in altemative formats
wq-ww1sts4-31 • 1/24112 P"r 2 of 3
I
4�`
CITY of ORONO
I Sa
Municipal Offices
ti
G ' Street Address: Mailing Address:
2150 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323 0066
To: The Current Owner of Address q c'�5 —r 4)
City Ordinance requires that onsite sewage treatment systems in Orono be
inspected on a periodic basis. The onsite sewage treatment system at the above
address has been inspected and the following is known about the system. A
sketch of the known components of the system is available for most properties at
the Orono City Hall.
Imminent Public Health Threat
Yes
No
If yes, please contact the Onsite Systems Manager at 952-249-4626 within 10
days of receipt of this notice. The septic system must be brought into compliance
within 90 days. Failure to do so will result in referral to the City Attorney for
legal action.
System Identified s Non-Compliant
Yes
No
If yes, system must be brought into compliance by:
December 31, 2007
December 31,2010
Other
Septic Tank(s) Pump out Needed
Yes
No
The City recommends the septic tank(s) and/or lift tank be serviced and pumped
out every three years. Citv records indicate the tank(s) were last pumped out on
n U _. The tank(s) should be cleaned through the manhole and
not through the inspection pipes, this allows for proper cleaning.
Comments:
Insp r: � 6� Date of Inspection
Telephone (952) 2149-4600 0 Fax (9-52) 249-4616
www.cLorono.mmus
CITY of ORONO
Municipal Offices
F i O „'�►G Sbut Address: 95a.--a49-460 o
Hallie`Address:.
2150 Kelley Parkway P.O. Bac 66
Orono, MN 55356 Crystal Bay, MN 55323-0066
To Current Owner: 6 j Ur
Address:
City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below.
SYSTEM CONFORMITY (1-3):
1 CODE SYSTEM"An
IN
O '
which meets all the location,design and construction standards of the current Orono Municipal Code.
"
2 COMPLIANT SYSTEM' An ISIS which does not meet all the location,design and construction standards of the current Orono
Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and
which is not failing or an immineot throat to public health or safety.
3 `NON-COMPLIANT SYSTEM" A prohibited ISYS;an ISIS located within a designated 100-year flood plain,any ISIS which may
Or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any
reason;and any'S's with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics.
TANK CONDITION(5-7):
Tank inspection indicates:
5� Pumpout not needed at this time.
6 -Septic.tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years.
Tank was last pumped. ).
Make sure septic tanks are Dumped thronah®manhole and not throu¢hwhite inspection`►lues This allows for the Droner
cleaning. Keep water.softner and iron filter discharge out of septic system to prolone life of drainfield Ask pumper to test
alarm float to yermfv alarm is still workme in your house The alarm warns owner that septnee is about to backup into basement.
7 Inspection risers missing-tanks could not be ms ( pipe)must be installed in each tank. If
peered. Inspection risers 4"dia. i
tanks have not been pumped out within the last three years,they should be pumped out now.
DRAINFIELD CONDITION(8-10):
$) Drainfield is dry,no surfacing evident.
9 Some evidence of surfacing,not critical yet.
10. Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately.Repairs must be completed within 90 days.
COMMENT'S:
a_u_d
Date of Inspection Matt Bolterman- Septic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does
not guarantee or certify that an existing system will continue to fimcbm properly, but is merely an opinion of the adequacy of the system under current
conditions based on the available information.