2750 KELLEY PARKWAY DATE ISSUED: 04/12/2018
ORONO,MN 55356-
952 249-4600 FAX: 952 249-4616
ADDRESS : 1020 TONKAWA RD
PIN : 08-117-23-13-0014
LEGAL DESC : REG.LAND SURVEY NO.0617
: LOT 000 BLOCK 000
PERMIT TYPE : ACCESSORY STRUCTURE
PROPERTY TYPE : RESIDENTIAL
CONSTRUCTION TYPE : POOL-IN GROUND
ACTIVITY : 329-STRUCTURES OTHER THAN BUILDINGS
VALUATION : $ 25,000.00
NOTE: SEPARATE PERMITS REQUIRED: MECHANICAL,ELECTRICAL(STATE)
APPLICANT PERMIT FEE SCHEDULE 433.67
PRESTIGE POOLS STATE SURCHARGE(VALUATION) 12.50
87 COUNTY ROAD C WEST TOTAL 446.17
ST.PAUL,MN 55117- Payment(s)
CHECK 18300 446.17
OWNER
BURKE,FORREST
380 LEAF ST
LONG LAKE,MN 55356-
AGREEMENT AND SWORN STATEMENT
The work for which this permit is issued shall be performed according to
the approved plans and specifications,applicable City approvals,and the
State Building Code. This permit is for only the work described and does
not grant permission for additional or related work which requires separate
permits. All provisions of laws and ordinances governing this type of work
shall be compied with whether or not specified herein.This permit will
expire and become null and void if construction authorized is not
commenced within 180 days of the date of issuance,or if construction is
suspended for a period of 180 days at any time after work has commenced.
The applicant is responsible for assuring all required inspections are
requested in conformance with the State Building Code.This permit may be
revoked at any time for due cause.
Applicant Permitee Signa Issue Signature Date
City of Orono
Building Permit Application
for Swimming Pools and Hot Tubs
�0 Mailing Address: Permit number: p�P`F 00-315 0
PO Box 66 p
Crystal Bay, MN 55323-0066 Date received: 3 v O
�l' b Street Address: Received by: G
y� ti 2750 Kelley Parkway Plan review fee:
SHO��G Orono, MN 55356 0210 _ 003 Total Fee:
Main: 952-249-4600 Fax: 952-249-4616 www.ci.orono.mn.us
This application form must be completed in full and all required information must be submitted.
Incomplete applications will be returned. (Please print)
GENERAL INFORMATION: �-
Job Site Address:
CONTRACTOR/APP,LrICANT INFO,k2M,QTION:
Name: P,/? si76 c- S
State License# Expiration Date:
Phone: 6S/-y90 i3Q4 Fax:
Address: City: T' ZIP: �-
Contact Person: nit Contact's phone number _ G/� 7--70_i7 z 3�—
Email: a Applicant is: Contractor Homeowner (Circle One)
PROPERTY OWNER INFORMATION:
Name: 14- D. "A-, * --�
Phone (day): /007o Tar�i«:,v.4
Mailing Address: ZIP:
Email and/or Fax:
ENGINEER INFORMATION:
Name:
Phone:
Address: City: ZIP:
Email: Fax:
PROJECT INFORMATION:
1. Pool/ Hot Tub Dimensions: 4.Accessory to: 5.Type: 7. Retaining Walls?
/41 X 3r- feet
2. Heated? yes ❑ no ❑Above ground El yes no Height
�-Single Family � i
3. Excavated materials will be: ❑ Multiple Family/Condo 9�In-ground "A building permit is required
removed from site for any wall 4-feet or greater in
used on site El Public ❑ Other(specify) height measured from the
❑ Other: (specify) ❑ Commercial bottom of the footing to the top
Total Cubic Yardsof the wall, even if it replaces
❑ Industrial 6.Sewage Disposal& an existing wall.
***Any earth movement may require ❑ Other:(specify) Water Supply
Tiered walls are considered
MCWD review and permits.
one wall unless they are
Minnehaha Creek Watershed District(MCWD) ❑ Public Sewer
separated by twice the height
15320 Minnetonka Blvd
Minnetonka, MN 55345 El Private Sewer of the higher wall.
Phone: 952-471-0590
El Public Water
Fax: 952-471-0682
www.minnehahacreek.org ❑ Private Well RECEIVEn
Estimated Construction Value $
Packet Last Updated., April 2016MAR � n �(tl 1.,
Page 22 U
CITY OF ORONO
REQUIRED SUBMITTALS:
All of the information must be submitted in order for your application to be processed:
Not
Enclosed Applicable
❑ ❑ Building Permit Escrow Agreement and Fees
❑ ❑ Plan Review Fee
❑ ❑ Completed Application Form
❑ ❑ Proposed Pool or Hot Tub Plans—2 sets,full-size, to scale
❑ ❑ Survey—2 full size, to scale(meeting ALL survey requirements)
❑ ❑ Hardcover Information
❑ ❑ Septic System Certification
❑ ❑ Minnehaha Creek Watershed District(MCWD) Permit or
documentation from MCWD stating no permit is required
❑ ❑ Landscape Walls and/or Retaining Wall Plans
❑ ❑ Stormwater Pollution Prevention Plan
❑ ❑ Data Privacy Advisory Form
❑ ❑
APPLICANT ACKNOWLEDGEMENT:
• Agrees to provide all information required or requested by the Planning&Building Departments;
• Understands, if applicable, an as-built survey and as-built hardcover cover calculations, are required to be submitted after the
project is complete( including final grading and landscaping)prior to refunding the escrow;
• Certifies that the information supplied is true and correct to the best of his/her knowledge. The applicant recognizes that they are
solely responsible for submitting a complete application being aware that upon failure to do so,the staff has no alternative but to
reject it until it is complete;
• Some or all of the information that you are asked to provide on this application is classified by State law as either private or
confidential. Private data is information which generally cannot be given to the public but can be given to the subject of the data.
Confidential data is information which generally cannot be given to either the public or the subject of the data. Our purpose and
intended use of this information is to annually update our records and records of other governmental agencies required by law. If
you refuse to supply the information,the permit may not be issued.
Applicants Signature: 2- lam— Date:
Owner's Signature Date:
Packet Last Updated., April 2016
Page 23
PLAN REVIEW CHECKLIST FOR NEW STRUCTURES / ADDITIONS
Address: 'N-o -mn 6awa- Ep�? Permit No.: ZOLL -Oa3l90
Description of work: -a&P4 ' Date Rec'd: ✓ � ' C�
Septic review by: Date Approved:
Zoning review by: Date Approved:—+
, '� O
Building review by: J Date Approved:
Grading review by: W Date Approved:
Zoning District: 'I IE> Zoning File M 11 3q51
Resolution? Yes ddReso#:I Reso Date:ALa_- 1_1 Signed: Yes No Resolution /NA
Zoning: Lot Area: •O SFAC Width: Structural Coverage: SF %
Su5n M, Iv
l:
�
: � 0 s No Date of Survey: 1' 2
w/1.1 ( Revised date(?):
Landscape plan submitted? 0 Yes Landscaper: Ya&UY210 _7_2&1-7 0 No/ None proposed
Proposed Setbacks: Unn(ri Q52—• 06�• 27 "1
Fr t(Lake) R�(Street) ((N�S E W ) ( N E W ) Other Buildings Wetland
/ ��....// Side de
N �v 51 ' 5 '
Building Height Analysis:
Distance Between First Floor and defined Top of Roof*,S6e"building height" (a)
definition
First Floor Elevation from building lans : (b)
Highest Existing ground level (per ey) or 10' above lowest ground level, (c)
whichever is lower:
Difference between b c *: (d)
i
DEFINEDHE T
"If highest sting adjacent grade is above FFE-Height is(a)-(d): (e)// ED
"If highest existing adjacent grade is below FFE-Height is a + d
Shoreland District MCWD Permit Average Lakeshore Setback Bluff
Met?
Yes 0 No Permit Number: _ 0 Yes No N/A 0 Yes No
0 N/A-see attached U_ CUSetback:
Stormwater Quality Existing Proposed
Overlay District Tier Hardcover Hardcover Variance Required CUP Required
circle one % and sf % and sf
2Z-772-0b. Yes 0 No 0 Yes o
1 2 3 4 5Type(s): Type(s):
I(P, N/W
Updated: June 2017
z:\forms\plan review checklist 06-2017.docx
S
Fees to be Charged YES NO
Permit
Plan Review
Stats Surcharge
Investigation Fee
SAC—Number of SAC Units
Other(specify)
Square Footage $ per Square Footage
Basement X $
1 st Floor X = $
2nd Floor X = $
Garage X = $
Estimated Construction Value: $ coo
Orono Inspections Required Work Requiring Separate Permits
Footing d Site , 'D Plumbing 0 Grading/Filling
0 Poured Wall 0 Silt Fence/Erosion Control XMechanical 0 Fire
0 Foundation Survey Cl Hardcover Removal -0 Fireplace 0 Water Connection
D Framing 0 Other(specify) 0 Masonry 0 Sewer Connection
0 Waterproofing/Drain tile 0 Mfg. 0 Lawn Irrigation
0 Foundation Waterproofing 0 Other(specify) 0 Landscaping
0 Framing 0 Septic
0 Insulation
-Built Survey
Final
0 Lathe Required State Permits
0 Other(specify)
0 Well Electrical
REMARKS (in-house):
OFFICIAL REMARKS -TO BE NOTED ON PERMIT AND INITIALLED:
0 See Builder Acknowledgement Form
- Prtor to release of escrow money areas-built survey,and hardcover calculations must be submitted and approved.
Updated: June 2017
z:\forms\plan review checklist 06-2017.docx
..�..,
�: _�
.���
�`�.
���
����
`�>:'
�.
„�
�.
_,
;�.
�y,
��a
��
,�
� "
u�--
�-1
�a "
Win.`
�;���
_� �r�...
A. .'
x
�, � ..
��,
N sr =ff
`�
} �+.
a ,,
� �F
'�
aa,
�+;.
+?std'
."��r„
� ,
j i
��
},�,.
,r g
�FFk�'
R� �
t��€q�
��
�„='�
�,�','
r��
��3
��v
.:
-�'F.
'& ;yam
e�k,
`.",,<rt
�{��£
te'�t:
Jeff Schmit
From: Chase Vanderbilt <cvanderbilt@minnehahacreek.org>
Sent: Thursday, March 29, 2018 10:17 AM
To: Melanie Curtis;Christine Mattson (Orono)
Cc: forrest_burke@uhc.com;Jeff Schmit
Subject: MCWD Permit 17-256 Amendment: 1020 Tonkawa Road,Orono
Attachments: MCWD Permit 17-256 Amendment.pdf; 17-256 Permit.pdf
Good Morning,
Please see the attached file for a permit amendment to MCWD Erosion Control Permit 17-256.The proposed addition of an in-
ground pool has been deemed in compliance with MCWD rules and therefore has been amended to permit 17-256. 1 have
attached a copy of permit 17-256 and it should be noted that this permit expires 6/14/2018, but can be renewed if needed.
Thank you and please let me know if you have any questions regarding this permit.
Best regards,
Chase Vanderbilt
District Representative
Minnehaha Creek Watershed District
Direct 952.641.4580
M{NNEHAHA CREEK 15320 Minnetonka Blvd., Minnetonka, MN
WATERSHED DISTRICX www.minnehahacreek.org
RECEIVED
MAR 10 ?(j 18
1 CI'T'Y OF ORONO
Permit Application: Self-Checklist for Completeness
Please note, the applicant must initial in the boxes below to acknowledge the minimum
required information is included with the submittal. If not, the application will NOT be
accepted. Call 952.249.4620 to schedule a meeting with staff if you have questions on
application submittal requirements.
Completed Application
-' Plan Review Fee Paid
Signed Escrow Agreement & Escrow Payment
El' Building
Plans (to scale) x2
11 Certificate of Survey (to scale) showing the proposed project &
meeting all requirements x2
j' Hardcover Calculations (if applicable)
I am aware that Orono will not issue a building permit without is
copy of MCWD permits (or documentation from the MCWD stating
the proposed project does not trigger their permitting
requirements). I will contact the MCWD at 952-471-0590
regarding this project.
Signed by:
Address: w
Permit #: 4 C)
Packet Last Updated: April 2016
Page 2
ATA PRIVACY ADVISORY
In accordance with Minnesota State Statute 13.04 Rights of Subjects of Data, Subd. 2, "Tennessen warning", We
would like to inform you that your request for a permit or license from the City of Orono or any of its departments
may require you to furnish certain private or confidential information.
You are notified that:
1. The information you furnish will be used to determine your qualification for the permit or license
requested.
2. You may refuse to supply data, but refusal may require that the City deny the permit or license.
3. The information may be shared with other local, state or federal agencies to the extent necessary
to process the permit or license.
4. If your requested permit or license requires Council action to approve, some information may
become public.
5. You have certain rights under Minnesota State Statute 13.04(see following page)to review private
data on yourself.
6. Your full name is required to process this application or permit.
4772<</<' �l�v>�4�2D ���/!/2
First Middle Last
e�7 ifs i
Address
/2-•7.T0 -/23.J
City State Zip Phone
I understand my n hts as stated above.
nature
KECEIVED
MAR 30ZU'id
Packet Last Updated: April 2016
Page 9 CITY OF ORONO
7, PRESTIGE
1
rrrrrrrrrrrrrrr - -r r� rrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrr
rrrrrrrrrrrrrrrt� I' -rrrrrrrrrrrrrrrrrrrrrrrfrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrr-rrrrrrrrrrrrrrrr
' 651.490.1399
'••.•. prestigepools.com
87 County Road C West • St. Paul, MN • 55117
Attached are documents pertaining to the equipment that is installed on each one of our pools. If you
are in need of further information on any specific item, please refer to our website and go to the
equipment tab, or contact us at our office and we would be glad to get you additional information.
for Code
Thank • compliance t., •
Pat Y e+wy Dat
Reviewer
AM~
firWrt
i'lli-I COPY
RECEIVED
MAR 13 0, 1 •
CITY OF •-• •
"
Rc�! t 1r �� _ rrct5l IVt YVULS
`0 87 Co.Rd.C.W.
St.
J "NO DIVING"LABELS MUST BE INSTALLED '
V' AROUND SHALLOW END OF POOL IN N -'
L..4 :g '� ACCORDANCEWITHLINERMFG.DIRECTIONS.
c_� f
CORNER DETAIL
PANEL
it *ER
COFIA X 12' rT G CORNER
U
'NUT&BOLT
' I
c.z RIM COPING
OPTIONAL STEP CONCRETE
r` a coPwG
POOL SIZE
`-•3:rtPOINT'A
DIM] 18X36 20X40
A 16'-0' 18'=0' 20=0' TEK SCREW PANEL
V_0, LINE
WATER 8 32'-0' 36`-0' 40'-0'
.10"
MIN. D i MIN ` 42" C 8'-O -0' B'-O`
MIN. ^� D 3'-4` S-4' 3'-4
C E 4'-0' 0!0' 4'-0'
UNDISTURBED F 6'-O' 8'0' 10'-O'
EARTH G 14'-0' W-W 14-O'
2"SAI0
ND OR -H 8'-0' - 12
0` `-O'
VERMICULITE I 4'-0' 4'.-0' 4'-0'
J 81-O' IO'-O' 12'-O'
E #-- F G H H 9` BRACE DETAIL
NOTES:
DIAGONAL BRACE
1 THUS IS A TYPE 11 POOL IN ACCORDANCE NMI N.S.P.1 STANDARDS
JAN. 1969 AND BOCA CODE 1993 - SECTION 421GTH NO.OF.PANEL LEN
2 EACH CONCRETE. 4'- O' LEN
CH RCE TALI, BE MOUNDED WITH A MINIMUM OF 1 FOOT OF 9'-O" BRACE FyINEt
3 MAXINUM LENGTH OF DIVING BOARD - 8'; JUMPSTAND - 61. 16 LENG TH 4 — 3
4 'NO DIVING' LADEIS MUST BE INSTAIJED AROUND SWALLOW END " W DTH — 2 I SEE NOTE 2
OF POOL IN ACCORDANCE WITH LINER MANUFACTURES 1 ENG _ _ 4 3
INSTRUCTIONS i T — 2 I ,;Ky
Ax NGT
RNING
40 WIDTH I 2 2 MOR120NTAL.BRACE
SWIMMING POOLSARE DANGEROUSWHEN USED IMPROPERLY!CONSULT YOUR TAKE
DEALER FOR SAFETY INFORMATION ON THE SAFE USE OF SWIMMING POOLS.
R IS THE RESPONSIBILITY OF TOWN OFFICIALS,BUILDERS AND HOME OWNERS TO S P E C IF I CAT 1 ON r~ HUSTON SUPPLY CO.
..�...� u.� „
FOLLOW ALL SAFETY RECOMMENDATIONS OF N.S.P.L,ALL LOCAL ORDANCES 16X321 IBX 36 20 X 40 o _....ALBERTP•4
AND EQUIPMENT MANUFACTURERS. AREA-SQ.FT 512 648 800 ^�•�--� � STANDARD RECTANGLES
GALLONS (9,500 1 24600 1 30.500 1 ,w1/4' WITH 6' RADIUS CORNERS
INTELLIFLO® 2 VST VARIABLE SPEED
:z
HIGH PERFORMANCE PUMP
TRADEGRADE
BY PENTAIR
Featured Highlights
•Control keypad can be rotated for convenient
orientation on the pump or wall mounted with
t E Relocation Kit
Select
• Intuitive,easy to use menu structure for programming
t�PENTAIR and monitoring
• Interfacesperfectly with Pentair automation systems
that give you the convenience of mobile device control
_ i •Can be programmed to deliver exactly the speed/flow
required for filtration,water features,heating options,
ORP and.pH testing and dispensing,salt chlorine
m generators,suction cleaning and spas
Intelli Flo 2 VST Appliance .Totally enclosed fan cooled design for quiet operation
Efficient
Variable Speed Pump and long life
Database
•Top-mounted field wiring compartment makes access
Protected by U.S.Patent No.7,686,587;7,854,597;8,043,070;8,469,675; and installation easter
s
8,573,952;D568,340;D606,562,D611,430 and Patent Pending and all
ccrresponging foreign counterparts. •8-programmable speed settings and built in timer
IntelliFlo 2 VST Variable Speed pump is the next generation of Pentair's variable-speed pump technology. With energy savings
x; up to 90%versus conventional pumps,near-silent operation and advanced programming capabilities,this pump continues to
deliver everything a pool owner wants and reliability no other competitor can match.
y 9- P Y P
Ordering Information
Full Load Primary Listings and Port size Carton
Product Mode( voltage ,-Amps kW HP SF SFHP FREQ. Certifications' INP7) Wt,ILbs l
ENERGY EFFICIENT VARIABLE SPEED1NON-SVR5 MODEL)
011055 IntelliFlo 2 VST 230 16 3.2 3 1.32 3.95 50Hz/60Hz UL',NSF',APSP' 2 in.x 2 in. 55
ACCESSORIES
521109 IntelliCom 2-Rated 9 30 V DC with 4 inputs 1
350122 Communication Cable-50 ft.-Included with pump 2
357156 Chemical-Resistant-Lid
356904Z Keypad Relocation Kit 2
34
st
11201-0154 2 in.x 2 in.Union 12 in.NPT male x 2 in.female NPT quick connect) *Note:two required per pump(sold individually) 2
,
St`
U indicates that pump bears a UL mark signifying evaluation to U.S. 'APSP'Pump has been evaluated to ANSIiAPSP/ICC-15 and CaGfoniiia
Standards UL1081 for Permanently Connected Swimming Pool and Spa Title 20 and is certified to use on Residential Swimming Pool Filtration
m` Pumps and to Canadian Standards CAN/CSA 0222 No 108-01 Liquid Systems.
Pumps For Swimming Pools Only 16nclosure 3). Product may have been evaluated to other state and local regulatory
NSF indicates that um bears a NSF mark signifyingevaluation to standards.Listing status may change.Always confirm status with
ftp pump y Y 9 Y
x p NSF Standard 50 For Self-Priming Centrifugal Pumps For Swimming appropriate agency if in doubt.
Pools Only.
.r, Note:Pump must be used with current collectors when installed on spas
or hot tubs in Canada.
Refer to catalog page 45 for a selection of 2-Pole GFCI breakers
7�o4 which offer 6 milliamp personnel protection while meeting
2008 to current NEC Standards for Pool Pumps.
jr+
F
t e-
a.
MASTERTEMP° HEATER
HIGH PERFORMANCE ECO-FRIENDLY HEATERS
ot� PENTAIR
Featured Highlights
Heats up fast sono long waits before enjoying
rte'
_ your pool or spa
- ''
select • Best-in-class energy efficiency*
• Manual gas shut-off when service is required
�PENTAIR"
• Eco-friendly MasterTemp Heater is certified for
"' low NOx emission and outperforms industry
standards
• Rotating digital display allows for easy viewing
f • Tough,rustproof exterior handles the heat and
weathersthe elements
F._ MasterTemp High Performance Heater • Certified for outdoor and indoor installations
a For Air Intake Kit order part number 461031
Master-Temp heaters offer at[the efficiency,convenience and reliability features you want in a pool heater,plus a lot more.As
easy to use as your home heating system, plus, user-friendly indicator lights make system operation and monitoring a snap.
The compact design and super-quiet operation won't intrude on your poolside leisure time. Heavy-duty(HD)unit with cupro-
k nickel exchanger stands up to the harshest of applications,like low pH,high flow or heavy use.
Ordering Information
Product Gas Type BTU(000's)' Carton Qty, Carton Wt.
_EMP HEATERS
460792 Natural 175 1 128
460793 Propane 175 1 128
460730 Natural 200 1 128
460731 Propane 200 1 128
461000 Natural 200 ASME 1 138
461001 Propane 200 ASME 1 138
460732 Natural 250 1 133
460733 Propane 250 1 133
460771 Natural 250 ASME 1 140
460772 Propane 250 ASME 1 140
t 461020 Natural 250ASME HD 1 140
460806 Natural 250HD 1 136
460734 Natural 300 1 136
460735 Propane 300 1 136
,. 460736 Natural 400 1 136
460737 Propane 400 1 136
460805 Natural 40OHD 1 136
h' I
460775 Natural 400ASME 1 149 f'
461021 Natural 400 ASME HD 1 149
Ik 460776 Propane 400ASME 1 149
Note:The MasterTernp Heater is certified for low NOx emissions.
Standard Copper Heat Exchanger 841,- Effiaent.
t== Heavy Duty(HDI Cupro-Nicket Heat Exchanger 829jo Efficient.
CLEAN & CLEAR® PLUS FILTERS
FIBERGLASS REINFORCED POLYPROPYLENE TANKx
0011� PENTAIR
Featured Highlightsk
• NSF listed
•Superior strength ` +
• Large filter area for increased j
dirt capacity
•1-1/2 in.,100%drain clean-out port select
r�.
•
Continuous High Flow'Internal PENTAIR'� R
Air Relief'*
• Base and plumbing kits now available
Clean & Clear
• Injection molded tank Plus Filter
• Balanced hydraulic flow
•Tension Control'Clamp
• 100%factory tested Clean&Clear Plus Filters have a corrosion resistant injection molded
• Black bulkhead unions filter tank featuring superior strength and reliability. The cartridge
assembly uses four easy to clean, non-woven, polyester cartridges.
• High Flow manual air relief valve Each filter is supplied with a bulkhead union set for easy installation.
Ordering Information
Tgrnaver Capacity
Product Madel Effective Filtration Flow Rate' 6n Gatlansi Carton Carton
Area[Sq.Ft.) (GPM Res) Qty._ Wt.Us.)
B Hour 40 Hour - 12 Hour
CLEAN&CLEAR PLUS FILTERS
160310 CCP240 240 90 43,200 54,000 64,800 1 60
160340 CCP3201 320 120 57,600, 72,000 86,400 1 70'
160301 CCP4201 420 150 72,000 90,000 108,000 1 80
160332 CCP5201 520 150 72,000 90,000 108,000 1 90
NSF:_fisted
Residential rate.375 GPM per sq.ft of filter area.
�e a�eda�e O eTOP P eeTe�s ��� Dimensions and Performance
Dimension Table ►sHuissadso
Model A Dim. B Ohm,
s 160310 37' W Note:Actual system flow will depend on plumbing size and
A 160340 43° 62` other system components.
160301 49" 68' Note: Pentair Aquatic Systems does not recommend flow
160332 56' 74" rates above 150 GPM.
IS-N"
k'
* Integrated continuous High Flow internal air relief is
operational only when there is unobstructed flow in the
circulating system.
Note: Operating Limits - maximum continual operating
pressure of 50 PSI.Pool/spa(bather)applications,maximum
operating water temperature(internal filter) 104°F(4000.
See page 377 for replacement parts.
SAYET|MEREDUCEMANUALHANDL|NGUFCHEM|C4LS K4gDEL320FEEDER
Chamber Capadty—'1^Tablet BottomFeed Top Feed
youchoosethe freestanding Model 38Ofeeder or-
Quantity---------------'Y8----------Y8
,hei,-6ncModel,32Ofeeder, Rambowllecdcrswill take the Weight...........................................3.5tbe......................3.5tbs.
wno`arid worry out ofkeeping yourpool Spar kUngclean arid
Chamber Capmdty--3'Tablet
ro,idy to use. O ----------------1l ----------ll
We�hk--------------.4��e-------.�8�s
���DEL3OOF�EOE�
Ma�mumErwy�nin24Hours 067ibs.................... �5�s.
�ho�b�r�apac�y �umnU� Weight —
l'Tabtet------------Y8-----------3.5Ubs. Treat Pool/Spa Size inGallons per 24Hours*
3'Tablet....................................ll .................................4.8tbs. @1Oppm........................................6 -------' 500
@5ppm........................................l3,4OO.......................35,000
Maximum Erosion in24Hours ....................................1]Ytbs. @ ..................................... 6,8QO.......................?&0OU
Treats PooVSpaSize inGallons per 24Hours* Dimensions..............l73/4'Hx5lNx1U'D...173/4'Hx5Wx10'O
@10PPM.........................................................................ll
@5ppm...........................................................................23,8U0 Service Clearance for Lid Removal...lY' ..l9'
@ 216ppm........................................................................47,600
*Using 1 trichtor mus
Dimensions....................................................... 1^HxTV x1ZD
Service Clearance for Lid Removal..................................221/4'
*U5i"e1 mcuo tabs.
AVAILABLE FROM:
0(ushntion oNIvIodel 200 Feeder V/us/ralionof Model 320 Feeder
P E NTA I R
�6201-xwK/m5iWE.SAmFORD,NC27330 800.831,7133 WWWPENTx|RPO0LCOw
pumps ^ hhers ~ hea|ers ~ heai �urops ~ auk)mahon ° 6�hhng ^ c4eners ° saniiizeo ^meierfeaiures - mainienanceproduc�s
onsPart wR5-m/s020nPentair Water pomand Spa,Inc.wxrights reserved. N.�,ra=�°°*..=u~�.=.�.~° =��~,�=°��,,=~
e f
molk�� Professional Service Industries, Inc.
N Pittsburgh Testing Laboratory Division
TESTED FOR: Cover-Pools, Inc. PROJECT: Pool Cover Safety Tests
ATTN: Kelly Ragsdale
66 East 3335 South
Salt Lake City, Utah 84115
DATE: August 19, 1993 OUR REPORT NO.: 706-30110-001
On August 16, 1993, Professional Service Industries was contacted by Cover-Pools, Inc. and asked that
PSI review ASTM Standard F 1346-91 to see if tests performed by PSI in May and June of 1990 meet
the standard performance specification of ASTM F1346-91. The standard was reviewed, and tests
performed by PSI meet the requirements of ASTM F1346-91. The following is a report issued by PSI
to Cover Pools, Inc. are of Pool Cover Safety tests which meet the criteria of ASTM F1346-91 (formerly
ASTM ES 13).
On May 31, 1990, a representative of Professional Service Industries was at the Corporate Offices of
Cover-Pools, Inc. located at 69 East 3335 South, Salt Lake City, Utah 84115, to perform safety
requirements tests on Cover-Pools, Inc., Save-T-Cover 11 safety covers. The safety tests performed were
in accordance with ASTM ES 13, Emergency Standard Performance Specification for Safety Covers and
Labeling Requirements for all covers for Swimming Pools, Spas and Hot Tubs.
A 16' x 32' pool was located at the Corporate Offices of Cover-Pools, Inc. The pool was equipped with
an under track Cover-Pool safety cover and top track (universal) Cover-Pool safety cover. The tracking
systems were connected to a redwood deck, with the connections at two feet on center along the length
of the deck. The safety cover fabric used in the under track system had a physical property of 16.2
oz/sq. yd. The safety cover fabric used in the top track system had a physical property of 13.2 oz/sq.
yd.
STATIC LOAD TEST
The static load test was conducted on both Cover-Pool safety covers in accordance with
section 9.1 of ASTM ES 13. The weights used were weighed using a calibrated scale
which is traceable to the National Bureau of Standards. The three weights used each
had an area of one square foot. One weight weighed 51.0 lbs., one 210.1 lbs. and one
226.3 lbs. The total weight used for the static load tests was 487.4 lbs. Three points
were tested for static load on each Cover-Pool safety cover. The locations of the three
points are as follows:
4' from the end of the pool in the center.
10' from the end of the pool in the center and in the center of the pool.
Both Cover-Pool safety covers met the performance requirements for the static load test
as outlined in ASTM ES 13 section 7.1.
2955 South West Temple Street • Salt Lake City, UT 84115 • 801/484-8827 Fax 801/487-3312
PERIMETER DEFLECTION TEST
The perimeter deflection test was conducted on both Cover-Pool safety covers In
accordance with section 9.2 of ASTM ES '13. With a 50 Ib. weight placed 4' from the
edge of the pool on top of the safety cover, the test object was unable to pass through
any opening at the perimeter of the pool. Both Cover-Pool safety covers met the
performance requirements for the perimeter deflection test as outlined in ASTM ES 13
section 7.2.
SURFACE DRAINAGE TEST
On June 12, 1990, the surface drainage test was conducted on a Cover-Pool safety
cover which was installed on a local private pool. The tracking system was an under
track system. The pool dimensions were 14.17'x42.5'. The surface drainage test was
conducted in accordance with ASTM ES 13 section 9.3. Water was applied evenly at
a rate of 11.7 gpm per 1000 sq. ft. A small sump pump, with discharge capacity of 20
gpm, was placed at one end of the safety cover with the discharge hose snaking the
length of the pool, on top of the safety cover, and discharging at the opposite end from
the pump. The water was applied for 30 minutes with the pump on and in place. The
water was then shut off and the pump was allowed to run for an additional 30 minutes. _
The test mannequin (Timmy) was then placed upon the safety cover. At the end of 3
minutes after placing Timmy upon the safety cover, an unsafe amount of water as
described in ASTM ES 13 section 9.3.1 did not exist. The Cover-Pool safety cover met
the safety requirements as outlined in ASTM ES 13 section 7.3.
All safety covers and equipment tested were standard as provided by Cover-Pools Inc. Safety covers
were installed according to Cover-Pdols, Inc. standard installation criteria.
Inspector: Jerry Hall
RESULTS ARE APPLICABLE ONLY To SPECIFIC SAMPLES TESTED.
REPORTS ANY Nor BE REPRODUCED.EXCEPT IN FULL.YMTIIOUT
WRITTEN PERMISSION BY PSI.INC.
Respectfully submitted,
Professional Service Indus(ries, Inc.
Jerry G.Hall
Department Manager
i
10,
Hayward in-ground pool skimmers are the preferred choice of professional pool builders. Engineered for residential
applications, these large capacity skimmers are manufactured to Hayward's rigorous quality standards. Their
durable, unibody construction is molded of rugged ABS, and they've been designed without submerged joints.
Hayward skimmers come with multiple plumbing connections for easier installations.
All Hayward skimmers are non-corrosive, non-conductive and virtually indestructible, no matter what Mother Nature
dishes out.
All vinyl/fiberglass pool skimmers are packaged with face plate,gaskets and screws.
SP io8o AutoSkimT" Series
• AutoSkim features include an automatic by-pass for low water conditions,
adjustable cover collar, snap-in weir that adjusts automatically to water level
fluctuations up to 4 t/a", a rigid, 163 cubic inch basket, integral Flo-Control
slide plate and a choice of threads for piping versatility. The SP1 084 line—
engineered for in-ground vinyl/fiberglass applications—offers an 8 1/2" throat,
a weather-beating ABS face rim for longevity, and 9 1/Q" diameter round cover
� � splosa, (10841 R).They are also available with Float Valve and Equalizer Kit to meet
specific NSF commercial requirements.
ThroatModel Pipe Cover
Number • oduct Descriptions
SP1 0841 1?'2"FIP Square 8''2" 1 13 lbs.
SF'1A$419', 2'" lP Rour}d 8Z" 1 1316s. '
SP10841OM" 1 vz"FIP Square 8 V�" 1 13 lbs. ABS body,adjustable cover collar,tamper-proof cover.
basket,weir,Flo-Control slide plate,ABS face rim(white).
SPIO$41QMA"' �, FtP end' $ "°'� 13J s gaskets.and screws.
SP1084" 2"FIP Square 8 111¢" 1 13 lbs.
'Skimmer includes standard and extra long 1 1A"screws.
-Available in Dark Gray-add suffix DGR for Dark Gray.
"R"designation indicates round collar and cover assembly
OM designation indicates thru-wall,outside mount for inetal wall installations.
7
h1•"'TO
• • + • •
• ,� /VtT.i�tt•1,�i
via
rr
• l:12YbQ- • •�•#
! • ¢ • i
t•6N �V �F
.Teo
esti•^ �1`w
r ern OMWI
Measurements cve too retaten.:e only,
Page 3 of 8 DUAL SUCTION OUTLET SET ISDUALSWG REV D
• RECOMMENDED SYSTEM SPECIFICATIONS:
ACCEPTABLE PIPE SIZE FOR MAXIMUM
RECOMMENDED 15 25 35 45 55 M Flow 65 75 85 95 105 115 '125
SYSTEM FLOW RATE PER APSP-7 p
-0.5
(6 FT/SEC IN THE BRANCH LINE) COVER ONLY
Pipe Size Flow rate Pipe Size Flow rate
is
[mm] GPM [mm] GPM[Liter/Min] COVER IN 2"SUMP
[Liter/Min] i -2
1 '/2" 40 2 '/z" 90 E •2.5
[50] [150] [75] [340] 3
2" 63 3" 138 -3.5 �
[63] [240] [90] [522] ---- - -
4.5 ----._......- -........_.__............................_......._._....- - - _-- ---- --.-..-.
Chart 1 s
Flow vs Pressure Drop
WGX 1048E Suction Outlet Covers are rated for Floor Only at 125 GPM FIG 1 Note: 1"Hg=1.13 Ft of Head
WGI048EW Suction Outlet Covers are rated for Wall or Floor at 72 GPM
In the event of one suction outlet being blocked, the remaining suction outlets serving that system shall have a
flow rating capable of the full flow of the pump(s) for the specific suction system.
Example: In the System shown in Diagram 1,two(2)"Floor Only"suction outlet covers are selected and mounted.
These covers are individually rated for 125 GPM. For a desired flow rate through the pump of 100 GPM,a minimum
pipe size from the Chart 1 is selected at 3". At the desired flow of 100 GPM one cover could be partially blocked
and the other suction outlet flow would be below the rated 125 GPM of the"Floor"mounted suction outlet cover.
Since there are two outlets flowing in normal operation,and the allowable velocity in the interconnecting piping is
only 3ft/sec,the same pipe size is required in the interconnecting piping.
Example: In the System shown in Diagram 2, one(1)"Floor Only"suction outlet cover, rated at 125 GPM,and one(1)
"Wall or Floor"suction outlet cover, rated at 72 GPM are selected and mounted. For a desired flow rate through the
pump of 50 GPM, a minimum pipe size from the Chart 1 is selected at 2". At the desired flow of 50 GPM either
cover could be totally blocked and the other suction outlet flow would be below the rated 72 GPM of the wall
mounted suction outlet cover. Note: Flow may be limited by entrapping force in dual suction systems.
Minimum distance 3 feet Dual Outlets on Different Planes
(Pike Centerlines) Floor Outlets, (Elevation or Pian View)
Total system rated
flow 125 GPM Wall
72 GPM rated
Total System rated
flow 72 GPM Interconnecting
Interconnecting piping
piping c
System branch piping
System 125 GPM Rated
Branch piping
24 Floor 4.... M
Diagram 2
Diagram 1
12 HAYWARD Pow Products www.haywardpoo,l.com
A Hayward U%Ajwes,Inc.Company
HAYWARD® ISW61048COC Rev D
_w
CERTIFICATION OF COMPLIANCE
Contains: WG1048E, WG1048EBLK, WG1048EGR, or WG1048EDGR
Description: 8" Round Suction Outlet Cover
Ratings: Floor: izs GPM_Wall: Z2 GPM Open Area: 8 i in
Certified to Comply with Section 1404 of the Virginia Graeme Baker Act (VGB) Pool & Spa Safety Act
codified at 16 CFR part 1450. Initial Certification May 2011.
Manufactured: After September 10, 2oo9, by a Division of Hayward Industries, Inc. at K4-A, 214028
Block K4- A, Export Processing Zone Wuxi New District Jiangsu Province PRC 214028, China; or at
One Hayward Industrial Drive, Clemmons, NC 27012.
Certified by Hayward Pool Products, 62o Division Street, Elizabeth, NJ 07207, Phone 9o8-355-7995
Contact at www.haywardnet.com
Record Custodian is Customer Service at www.haywardnet.com.
Hayward Pool Products P.O. Box 5100 Clemmons, NC 27012-5100, Phone: 336-712-9900
http://www.hayward-poot.com/pdf/literature/8inroundCOC.pdf
Date of Mfr: The Lot Number shown on the product label contains the Year& Month of manufacture.
The first number represents the year (ex 1 = 2o11) and the second character the month (A=Jan,
B=Feb, H=Aug, I is skipped, J=Sep, etc)
Tested to: ANSI/APSP 16 (ANSI/ASME 112.19.8-2007 (addendum 9b-2009)) per Section 140 of the
Virginia Graeme Baker Act (VGB) Pool & Spa Safety Act. Tested by NSF International, 789 Dixboro
Road, Ann Arbor, MI 48113, Phone 734-769-8olo in April 2011. Certificate at:
httD://info.nsf.org/Certified/Pools/Listings.asp?Company=21600&Standard=ASMEigo8
Date of Installation:
Suction outlet components have a finite life, the cover/grate should be inspected frequently and
replaced at least every 7 years or if found to be damaged, broken, cracked, missing, or not securely
attached.
Hayward Pool Products acknowledges that it is a federal crime to knowingly and willingly make
materially false, fictitious, or fraudulent statements, representations, or omissions on this
certification.
6"
SPACING BETWEEN
MOUNTING HOLES
USED ON FOLLOWING SERIES:
00 00 WG1030AVPAK2 SP1030AVPAK2
0000000 WG1048AVPAK2 SP1048AVPAK2
000000 WG1049AVPAK2 SP1049AVPAK2
07 3/4" 0000000
00000000 WG1051AVPAK2 SP1051AVPAK2
0
SUCTION OUTLET 000 0000 WG1052AVPAK2 SP1052AVPAK2
0000 0000
COVER WG1048E 00000 WG1053AVPAK2 SP1053AVPAK2
000000 WG1054AVPAK2 SP1054AVPAK2
00000 0000 WG1153AVPAK2 SP1153AVPAK2
WG1154AVPAK2 SP1154AVPAK2
ir
A Warning—Suction Entrapment Hazard.
Suction in suction outlets and/or suction outlet covers which are installed in a small area and/or below the surrounding
surface can cause severe injury or death due to body entrapment hazard.
To reduce the risk of body entrapment,installation of the field fabricated sumps must be such that the top of the
mounted cover is a minimum of 11/2"above the finished pool surface over an area larger than 40"on a diagonal.
INTELLIBRITE° 5G COLOR LED LIGHTS
UNDERWATER LED LIGHTS FOR SWIMMING POOLS AND SPAS
4PENTAIR
Featured Highlights
• A superior reflector design assures more light is directed toward
the pool bottom to further increase intensity and color effects',
while minimizing glare •
• Superior lens geometry distributes light in an optimum way to (E4colv
avoid"hot spots"on the pool bottom.Light intensity and color are Select
distributed more uniformly throughout your pool. em:Y•c j
• Pool tens can be rotated to 180 degrees to provide wide beam PENTAIR
pattern(standard)or narrow beam pattern 11
• IntelliBrite LED Light technology makes use of the brightest and
most energy efficient LED's available in underwater pool and spa
lights-up to 50%less energy consumption than competitor's lights
•Set one of 5 predetermined fixed colors to match or create the IntelliBrite 5g CoLor LED Pool and Spa Lights
mood for the evening-blue,green,magenta,white,and red or
select from 7 popular"color shows"that come preprogrammed
into lntettiBriteLight IntelliBrite Lights automated color-changing pool and
• IntelliBrite LED Light was designed to work with lnteltiTouchmand spa tights feature LED technology—the wave of the future
EasyTouch°Automation,the leading control systems for pool,- in energy—efficiency, lifetime value, quality of light, and
spa,and pootscape equipment automation.In affect,you transfer controllability. With IntelliBrite Lights, combinations of
control oflntetliBriteLight tothe lntettiTouchorEasyTouchsystem individual colored LEDs are mixed and matched to achieve
which controls all your otherbackyard and pool features.
• IntelliBrite 5g Color Pool and Spa lights are backwards compatible a vibrant spectrum of colors.These combinations are power
with first generation IntelliBrite lights sequenced to illuminate and cycle through colors at varying
• Compatible with Pentair stainless steel and plastic niches speeds, and in different sequences of color. Combined
with a custom reflector and unique tens design, IntelliBrite
tights offers superb efficiency while being the brightest
yet most energy efficient underwater LED light available.
All Pentair UL Listed underwater lights are certified
for use in fresh water with up to 6,000 ppm salinity.
Ordering Information
Product Voltage Wattage Cord Length Carton Qty. Product Voltage Wattage Cord Length Carton Qty.i
(Fr.) (Ft.)
INTELLIBRITE 5g COLOR POOL LIGHTS INTELUBRITE 5g COLOR SPA LIGHTS
601000 120 26W 30 1 640120 120 18W 30 1
601001 120 26W 50 - 1 640121 120 18W 50 1:
601002 120 26W 100 1 640122 120 18W 100 1
601003 120 26W 150 11 640123 120 18W 150 1
601004 120 26W 250 1 640124 120 18W 250 1
601010 12 26W 30 1 640130 12 18W 30 1
601011 12 26W 50 1 640131 12 18W 50 1
601012 12 26W, 100 1 640132 12 18W= 100 1
601013 12 26W 150 1 640133 12 18W 150 1
Dimensions and Certifications
Note:Alt 120 volt pool.and spa tights,must be connected 196-�
to a branch circuit protected by a ground fault circuit
intcrnipter(GFCII i CIP
®
L
Nohcei Underwriters Laboratories has ti>Icd Pentair + �;
Wafer Pool and Spa, Inc. lights for use with Pentair • O
-r
Water Pool and Spa,Pentair Pool Products,American
Products, Purex,or PacFab niches ONLY. To ensure 1012
proper grounding/honding connections install only Please refer to pages
PentairWaterPool and Spa Lights inPentair,WaterPool j 120-122 for Canadian
and Spa,Pentair Pool Products,American Products, t 3,, Listed Pool Lights.
Purex or PacFab niches only. i`
,tI
See pages 476-477 for replacement parts. t
GLOBRITE° WHITE AND COLOR LED LIGHTS
UNDERWATER LED LIGHTS FOR SWIMMING POOLS AND SPAS
►:� PENTAIR
Featured Highlights A
•The brightest and most efficient q
LEDs available GloBrite LED LightEco-
1P t
•Can be placed in as little as 4 in. Fiberglass Niche ^a elect
of water even in the floor pointing up
• Does not require grounding or bonding PENTAIR
for quick and easy installations
•
•5 brilliant fixed colors and 7
pre-programmed light shows •
•'Compatible with IntelliTouch®or GloBrite LED Light '
EasyTouch@ Control Systems for
advanced control features 10
Vinyl Niche
•Compatible with gunite,fiberglass
and vinylpools GloBrite LED Light
Concrete Niche
GloBrite LED Lights use advanced technology for energy-efficient, high quality light displays, delivered with enhanced LED
brightness and superior optics,while using 18%less energy than other shallow water LED lights.Globrite lights are compatible
with IntelliTouch and EasyTouch control systems and IntelliBrite 5g LED pool lights.GloBrite LED lighting is a brilliant way to
showcase and enhance pool features like baja shelves,steps,beach entries and shallow water features.
Note:Only GloBrite white tights have two dimming levels. GloBrite color lights cannot be dimmed.
Ordering Information
Cord Carton Carton Cord Carton Carton
Product Voltage Wattage Length Qty. Wt.(Lbs.) Product Voltage Wattage Length'' Qty. Wt.ILbs.)
(Ft.l (Ft.)
GLOBRITE COLOR LED LIGHTS GLOBRITE WHITE LED LIGHTS
602053 12 15W 30 1 5 602102 12 15W 30 1 "5
602054 12 15W 50 1 6 602103 12 15W 50 1 6
602055 12 15W 100` 1 9' 602104 12 15W 100 1 9
602056 12 15W 150 1 12 602105 12 15W 150 1 12
Product` Description Carton Oty. Carton Wt.(Lbs.)
GLOBRITE NICHES
620040 Gunite Niche for GloBrite(includes white,blue,black,grey and tan rings) 1 1.3
620039 Vinyl Niche for GloBrite(includes white,blue,and grey rings) 1 1.3
620041 Fiberglass Niche for GloBrite(white) 1 1.3
620093 Fiberglass'Niche for GloBrite(blue) 1 1.3
620094 Fiberglass Niche for GloBrite(grey) 1 1.3
GLOBRIrE COLOR KITS
619993 1 GloBrite Color 100 ft.with 30OW Transformer+Gunite Niche 1 25
619994 2 GloBrite Color 100 ft.with 30OW Transformer+2 Gunite Niches 1 40
620051 1 GloBrite Color 100 ft.with 30OW Transformer+Fiberglass Niche 1 25 ,
620052 2 GloBrite Color 100 ft.with 30OW Transformer+2 Fiberglass Niches 1 40
620080 1 GloBrite Color 100 ft.with 30OW Transformer+Vinyl Niche 1 25
620081 2 GloBrite Color 100 ft.with 30OW Transformer+2 Vinyl Niches 1 40