2004-P07148 - mechanical
_ PERMIT i CfT Y OF ORONO 2750 Kelley Parkway - PO Box 66 Permit Number: P07148 Crystal Bay, Minnesota 55323 Permit Type: Mechanical Permits (952) 249-4600 Date Issued: 1/6/2004 SITE ADDRESS: 1000 Tonkawa Rd LONG LAKE,MN 55356 PID: 08-117-23-12-0005 DESCRIPTION: Proposed Use: Residential Permit Class: General Permit Type: Mechanical Permits Permit Sub-type(s): Heating Systems DETAILS: Approved per resolution#: Separate permits required: NOTICES/REMARKS: FEE SUMMARY: Permit Fee: $ 40.38 Valuation: $ 3,230.00 State Surcharge Fee: $ 1.62 Misc.Fee: $ 1.50 TOTAL FEE: $ 43.50 Sedgwick Heatin &Air Conditioning Inc. R J H APPLICANT: g`'�'' g g OWNER: oFFMANETAL 8910 Wentworth Avenue S 1000 TONKAWA RD Minneapolis,MN 55420 LONG LAKE MN 55356 THE UNDERSIGNED HEREBY REQUESTS PERMISSION TO MAKE THE REAL IMPROVEMENTS SPECIFIED AND AGREES TO DO ALL WORK IN STRICT COMPLIANCE WITH ALL CITY OF ORONO ORDINANCES AND STATE OF MINNESOTA BUILDING CODE REQUIREMENTS. APPLICANT PERMITEE SIGNATURE ISSUED BY SIGNATURE Conies: 1-File(Siznitures Required), 1-Applicant, 1-Monthly Reports, 1-Assessing, 1-Finance Page 1 CITY OF ORONO APPLICATION FOR MECHANICAL PERMIT Box 66 (2750 Kelley Parkway) Crystal Bay, MN 55323 GENERAL INFORMATION 1. You may.apply for mechanical permits by mail or in person at the City offices. Applications will be reviewed and a permit will be issued within 2 working days. 2. Permit cards will be sent by return mail after a review is completed. PERMITS ARE NOT VALID UNTIL YOU RECEIVE A PERMIT. WORK MUST NOT BEGIN UNTIL THE PERMIT CARD IS POSTED ON THE JOB SITE. 3. Mechanical Designs - Complete calculations, details and specifications are required for each heating, ventilation, humidification-dehumidification, and air conditioning installation including heat loss/heat gain calculation, design temperatures, equipment ratings and identification as to type, manufacturer and model. Data shall be presented on form provided. Identification of and specifications for water heating equipment shall also be provided. 4. When any new construction or remodeling is involved, a separate building permit must be obtained. 5. All work must be done in accordance with the Uniform Mechanical Code/State Building Code requirements. 6. All work must be inspected (rough-in and final). Call 249-4600. 24-hour notice required. 7. House Heating Test Record must be submitted before final. Instructions Complete all items on this application. Compute the permit fee. Sign and date the certification. INCOMPLETE APPLICATIONS WILL NOT BE PROCESSED. If you have questions, call 249-4600. Please check one: New Addition Repair Replace esidential Commercial JOB SITEZip: Owner's Name: O Telephone Number: _ �7j- y7D�q Mailing Address: City: Zip: Contractor's Name: 6666 ,l1CK HEATNP,IR AIR CONDI i Wcphone Number: Mailing Address: 891 n wentworth Ave. Wy: Zip: Minneapolis,MN 55420 SYSTEM DESCRIPTION (952)881-9000 HEATING SYSTEMS Quantity: / Make: _ Model: d Fuel: Flue Size: " Input BTUs: e,4,4— Output dOutput BTUs: CFM: COOLING SYSTEMS Quantity: Make: Model: Tons: H. Power FIREPLACES Gas factory fireplace Wood burning factory fireplace with flue Wood Stove Wood stove with flue Brand Name Model No. VENTILATION No. Kitchen Exhaust ducted recirculating cfm No. Bath Exhaust (must be ducted outside) cfm No. Other Fans: Locations cfm FUEL STORAGE (MUST BE APPROVED BY FIRE MARSHAL) Installation Removal Fuel oil: gallons underground inside outside LP Gas: gallons Other Gas opening PERMIT FEE CALCULATION 1. 1.25% of Contract Price* or Minimum Fee 35.00 x .0125 $ (contract price) 2. State Surcharize. ** Add the State Building Code Division Surcharge to each permit. x .0005 $ or $.50, whichever is greater (contract price) 3. Postage and Handling (Only mail-in applications) $ 1.50 4. TOTAL PERMIT FEE (Add lines 1-3 above) $ a * CONTRACT PRICE or JOB COST means the actual or estimated dollar amount charged for the permitted work including materials, labor,profit, and other fixed costs. It is the amount to be charged to the customer for the work done. If any material, equipment, labor, or installation are furnished by the owner, tenant or any other party the reasonable market value of such items must be added to the estimated cost or contract price for permit fee purposes. In the event that there is a dispute on the amount of the job cost,the City may, request the submission of a signed copy of the actual contract. ** The STATE SURCHARGE is .0005 of the contract price under$1,000,000 or $.50 -whichever is greater. For valuations over $1,000,000 call the Department of Inspectional Services for the price. The undersigned hereby applies to the City for issuance of a Mechanical Permit, agrees to do all work in strict accordance with the ordinances of the City and the regulations of the Minnesota State Building Code, and certifies that all statements made on this application are complete, true and correct. Applicant's Signatu Date: / Approved By: Date: gwKk HEtfING&AIR CONDITIONING CO. RESIDENTIAL HEATING DATA SHEET Comfort you can count on JOB NAME: DATE ADDRESS: OUTDOOR TEMP: INDOOR TEMP: TEMP. DIFFERENCE: DESIGN TEMPERATURE DIFFERENCE UH MOVABLE GLASS WINDOWS SQUARE 30 35 40 45 50 55 60 65 70 75 80 90 L HEAT L 95 BT FEET HEAT TRANSFER MULTIPLIER OSS SINGLE GLASS 39 45 1 52 1 58 1 65 1 71 1 78 184 1 90 1 97 1103111-071-167123 SINGLE GLASS W/STORM 21 25 28 31 35 38 42 45 49 52 56 59 66 DOUBLE GLASS 28 32 37 1 41 46 1 50 1 55 60 1 64 1 69 1 73 78 82 JX7 DOUBLE GLASS W/STORM 16 19 21 24 27 1 29 1 32 35 1 37 1 40 1 42 45 48 50 SQUARE DESIGN TEMPERATURE DIFFERENCE BTUH SLIDING GLASS DOORS FEET 30 1 35 40 45 150 1 55 1 60 1 65 1 70 175 80 85 1 90 HEAT LOSS HEAT TRANSFER MULTIPLIER SINGLE GLASS 42 1 48 55 62 1 69 1 76 1 83 1 90 1 97 1104 110 117 124 131 SINGLE GLASS W/STORM 22 26 29 33 137 40 44 148 51 1 55 59 62 166 170 DOUBLE GLASS 1 29 1 34 1 39 43 1 48 53 58 1 63 67 1 72 77 72--L -7 91 DESIGN TEMPERATURE DIFFERENCE BTUH DOORS SQUARE 30 1 35 1 40 1 45 1 50 1 55 1 60 1 65 1 70 1 75 1 80 1 85 1 90 95 HEAT LOSS HEAT TRANSFER MULTIPLIER SOLID WOOD 31 1 36 1 41 1 46 1 51 1 56 1 62 1 67 1 72 1 77 1 82 1 87 97 SOLID WOOD** 18 121 24 27 30 33 36 39 142 45 147 1 50 1w56 M ETA L URETHANE 23 1 27 30 34 38 42 45 49 1 53 57 1 60 64 1 68 1 72 METAL URETHANE" 13 1 16 18 20 22 25 27 29 1 31 33 1 36 38 1 40 1 42 "'Weatherstripped or Storm RUNNING FEET CEILING HEIGHT x WALLS GROSS WALL = y Z WINDOWS & DOOR AREAS NET WALL AREA SQUARE DESIGN TEMPERATURE DIFFERENCE BTUH FRAME WALL FEET 30 1 35 1 40 1 45 150 155 160 1 65 1 70 1 75 1 80 1 35(1901,% HEAT LOSS HEAT TRANSFER MULTIPLIER NO INSULATION 8 10 1 11 1 12 14 15 17 18 19 21 22 23 25 1 26 R-11, 3" INSULATION 2.7 3.1 3.6 4.0 4.5 4.9 5.4 5.8 6.3 6.7 7.2 7.6 8. 8.5 R-13, 3-1/2" INSULATION 2.1 2.4 2.8 3.2 3.5 3.8 4.2 4.6 4.9 5.3 5.6 5.9 6.3 .6 R-13 + 1" POLYSTYRENE 1.8 2.1 2.4 2.7 3.0 3.3 3.6 3.9 4.2 4.5 4.8 5.1 5.4 5.7 R-19 + 1/2" POLYSTYRENE 1.6 1.9 2.2 2.5 2.8 3.0 3.3 3.6 3.8 4.1 4.4 4.7 4.9 5.2 DESIGN TEMPERATURE DIFFERENCE MASONRY WALL SQUARE BTUH ABOVE GRADE FEET 30 35 1 40 1 45 150 155 1 60 1 65 1 70 1 75 1 80 1 85 90 95 HEAT LOSS HEAT TRANSFER MULTIPLIER NO INSULATION 16 18 21 23 26 28 31 33 36 38 41 44 46 49 R-5, 1" INSULATION 4.3 5.0 5.8 6.5 7.2 7.9 8.6 9.4 10.1 10.8 11.5 12.2 13.0 13.7 R-11, 3" INSULATION 2.3 2.7 3.1 3.5 3.8 4.2 4.6 5.0 5.4 5.8 6.2 6.5 6. 7.3 O R-19, 6" INSULATION 1.4 1.7 1.9 2.2 2.4 2.6 2.9 3.1 3.4 3.6 3.8 4.1 4.3 4.6 DESIGN TEMPERATURE DIFFERENCE MASONRY WALL SQUARE BTUH BELOW GRADE FEET 30 1 35 40 45 150 155 1 60 1 65 1 70 1 75 1 80 1 85 1 90 95 HEAT LOSS HEAT TRANSFER MULTIPLIER NO INSULATION 4.4 15.1 5.9 6.6 7.3 8.1 8.8 9.6 10.311.011.812.513.214.0 R-5, 1" INSULATION 2.6 3.0 3.5 3.9 4.3 4.8 5.2 5.7 6.1 6.5 7.0 7.4 7. 8.3 R-11, 3" INSULATION 1.8 2.1 2.4 2.7 3.0 3.3 3.6 3.9 4.2 4.5 4.8 5.1 5. ' 5.7 R-19, 6" INSULATION 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 3.8 HEAT LOSS SUBTOTAL Z 7 ` Heat Loss Subtotal from Page 1 ✓ Z 2 DESIGN TEMPERATURE DIFFERENCE CEILING SQUARE FEET 30 35 40 45 50 55 60 65 70 75 80 85 90 95 BTUH HEAT TRANSFER MULTIPLIER HEAT LOSS NO INSULATION 18 21 24 1 27 30 1 33 1 36 39 1 42 1 45 1 48 51 54 57 R-11, 3" INSULATION 2.6 3.1 3.5 4.0 4.4 4.8 5.3 5.7 6.2 6.6 7.0 7.5 7.9 8.4 R-19, 6" INSULATION 1.6 1 1.9 2.1 12.4 12.6 12.9 3.2 3.4 13.7 14.0 14.2 4.5(4.0 5.0 O, R-30, 10" INSULATION 1.0 1 1.2 1 1.3 11.5 ; 1.6 11.8 12.0 12.1 12.3 12.5 12.6 12.9 13.0 13.1 R-38, 12" INSULATION 0.8 10.9 11.0 1 1.2 1.3 1 1.4 11.6 1 1.7 11.8 12.0 12.1 12.2 12.3 12.5 FLOOR OVER AN SQUARE DESIGN TEMPERATURE DIFFERENCE BTUH UNCONDITIONED SPACE FEET 30 35 40 45 1 50 1 55 1 60 1 65 1 70 1 75 1 80 1 85 1 90 1 95 HEAT LOSS HEAT TRANSFER MULTIPLIER NO INSULATION 10 11 13 14 16 17 19 21 22 24 25 27 28 30 R-11, 3" INSULATION 2.4 12.8 3.2 12.6 4.0 4.4 4.8 5.2 5.6 6.0 6.4 6.8 7.2 7.6 R-19, 6"INSULATION 1.6 11.8 12.1 12.3 2.6 2.9 3.1 3.4 3.6 3.9 4.2 14.4 4.7 14.9 R-30, 10"INSULATION 1.1 11.3 11.5 11.7 11.8 2.0 12.2 2.4 2.6 12.8 13.013.1 1 3.3 13.51 SQUARE DESIGN TEMPERATURE DIFFERENCE BTUH BASEMENT FLOOR FEET 30 35 40 45 50 55 60 -165-7-76 75 ' 80 '5("'90 95 HEAT TRANSFER MULTIPLIER HEAT LOSS BASEMENT FLOOR 10.81 1.0 11.1 1 1.31 1.4 11.5 11.7 11.8 12.0 12.1 12.2 2.4 ,2.t. 2.7 Z> p CONCRETE SLAB WITHOUT LINEAR DESIGN TEMPERATURE DIFFERENCE BTUH PERIMETER SYSTEM FOOT 30 1 35 40 45 1 50 1 55 1 60 1 65 1 70 175 1 80 85 1 90 1 95 HEAT LOSS HEAT TRANSFER MULTIPLIER NO EDGE INSULATION 25 29 33 37 1 41 1 45 1 49 53 57 61 65 K7=77 77 1" EDGE INSULATION 13 15 17 19 j 21 123 125 27 29 31 33 35 1 37 139 2" INSULATION 6.3 17.4 18.4 19.4 10.5 11.5 12.6 13.6 14.7 15.8 16.8117.8118.9 20.0 CONCRETE SLAB LINEAR DESIGN TEMPERATURE DIFFERENCE BTUH WITH PERIMETER SYSTEM F OT 30 1 35 1 40 1 45 1 50 1 55 1 60 1 65 1 70 1 75 1 80 1 85 1 90 1 95 HEAT LOSS HEAT TRANSFER MULTIPLIER NO EDGE INSULATION 57 1 67 1 76 1 86 1 95 1105 1114 1124 1133 1143 1152 j 162 1171 1181 1" EDGE INSULATION 34 1 40 1 46 152 157 163 169 174 180 186 191 197 11031109+- 2" 103 1092" EDGE INSULATION 28 1 33 1 37 1 42 1 47 1 51 1 56 1 61 1 65 1 70 1 75 1 79 1 84 1 89 An additional infiltration load is calculated only if the home is loosely constructed or when window infiltration is greater than .5 CFM per linear foot of crack. ff 7�(,, 1+D FLOOR SQ FT. x CEILING HEIGHT _-d>rUBIC FT INFILTRATION/ VENTILATION 0.40 x UBIC FT - 60 = CFM MECHANICAL VENTILATION CFM = FRESH AIR INTAKE DESIGN TEMPERATURE DIFFERENCE BTUH CFM 30 35 40 45 50 55 60 65 1 70 1 75 1 80 85 90 95 HEAT LOSS HEAT TRANSFER MULTIPLIER INFILTRATION 33 39 44 50 1 55 61 1 66 1 72 1 77:g7:889 88yl 105 MECHANICAL VENTILATION 0 33 39 44 50 55 61 66 72 77 83 88 99 105 p HEAT LOSS SUBTOTAL 2 DUCT LOSS BTUH HEAT LOSS R-4, 1" Flexible Blanket Insulation: ADD 15% 1.151 R-7, 2" Flexible Blanket Insulation: ADD 10% (.10) TOTAL HEAT LOSS NOTE: All Heat Transfer Multipliers from ACCA Manual "J" Sixth Edition. HL-841-0 002344 Litho U.S.A. DATE TIME CITY OF ORONO CALLED IN Ia1 OLl INSPECTION NOTICE SCHEDULED PERMIT NO. PC T^1Z COMPLETED ADDRESS /bO p 7©✓t>�a-�- l OWNER CONTR. CX- TELEPHONE NO. g5--- 1/-7 /- 9 7©(o DESCRIPTION W 01 FOOTING 11 MECHANICAL RI 18 EXCAV/GRADING/FILLING W 02 FRAMING 13 M HANICAL FINAL 19 LAKESHORE/WETLANDS h O 03 INSULATION 24/25 WOOD BURNER/FIREPLACE 34 TREE REMOVAL Z 04 WALL BD. 12 WATER HOOK-UP 17 SITE INSPECTION Q 05 FINAL 14 SEWER HOOK-UP 06 PROGRESS 07 DEMO-SITE 27 SEPTIC MAINT. 21 COMPLAINT J 07 DEMO-FINAL 15 SEPTIC INSTALL. 22 FOLLOW-UP 09 PLUMBING RI 23 SEPTIC FINAL 35 HARD COVER REMOVAL v 10 PLUMBING FINAL 36 FOUNDATION/REMOVAL OWNERICONTRACTOR TO MEET YOU:_YES_NO COMMENTS: Cc W a J O Cc O W W Cc Q Z W Z W Cc Uj WORK SATISFACTORY:PROCEED ❑PROJECT COMPLETE W et'CORRECT WORK&PROCEED ❑ ISSUE CERTIFICATE OF OCCUPANCY O ❑CORRECT WORK,CALL FOR REINSPECTION TEMPORARY BEFORE COVERING PERMANENT ❑CORRECT UNSAFE CONDITION WITHIN HOURS. ❑PHOTO TAKEN INSPECTOR WILL RETURN ❑STOP ORDER POSTED.CALL INSPECTOR ❑CITATION ISSUED ❑ INSPECTION REQUIRED.CALLTO ARRANGE ACCESS. Call for the ne inspection 24 hours in advance. (952) 249-4600 Owner/Contr ite: Inspector. White Copy/Inspector's File Canary Copy/Site Notice SEDGWICK HEATING & AIR CONDITIONING CO. TEST HEATING IICORD JOB NO. 3 8910 WENTWORTH AVENUE SOUTH • MINNEAPOLIS,MN 55420 (952)881-9000 ADDRESS Dab T oh k0.�� /eCITY ©✓600. OCCUPANT!�- /� / OWNER C �^ SOLD BY 1D` /'`eo-3 ) INSTALLED BY MAKE ���t.i� T ` MODEL �7 UV °f u' V I �b SERIAL NO. J uy ' cl ✓ 3 INPUT 9-11? THERMOSTAT ` is VENT SIZE V 7 VALVE �` TYPE OF LINER �/u LIMIT ! "� LINER SIZE / LIMIT SETTING FILTERS: SIZE d r? S' NUMBER ` FAN SETTING N? 4A WIRING G 1, f (J( z PILOT TYPE Z TEST TAG IGNITION MODEL l_� �� c�� ' LIGHTING INST. PILOT TIMING h t 4� o `� DATE TESTED PRESSURE �' PERCENT CO2 ` 6 COMPANY TESTING S�� C INPUT CFH � PERCENT 02 O � ��L/64 -Z c-,STACK TEMP. ✓ Z F PERCENT CO NAME OF TESTER FORM 235(REV.11/89) FORM DISTRIBUTION: WHITE COPY-JOB FILE YELLOW COPY-CITY