HomeMy WebLinkAbout2003-P06613 - mechanical C 1T� OF O RO N O PERMIT Permit Number: 2750 Kelley Parkway- PO Box 66 P06613 Crystal Bay, Minnesota 55323 Permit Type: Mechanical Permits (952) 249-4600 Date Issued: 7/31/2003 SITE ADDRESS: 847 Tonkawa Rd Long Lake,MN 55356 PID: 08-117-23-21-0003 DESCRIPTION: Proposed Use: Residential Permit Class: General Permit Type: Mechanical Permits Permit Sub-type(s): Multiple Mechanical Items DETAILS: Approved per resolution#: Separate permits required: NOTICES/REMARKS: FEE SUMMARY: Permit Fee: $ 500.00 Valuation: $ 40,000.00 State Surcharge Fee: $ 20.00 Misc.Fee: $ 1.50 TOTAL FEE: $ 521.50 APPLICANT: Vogt Heating&Air Conditioning(See Cor. OWNER: Dennis&Shawn Vaillant 3260 Gorham Ave 847 Tonkawa Rd St.Louis Park,MN 55426 Long Lake,MN 55356 THE UNDERSIGNED HEREBY REQUESTS PERMISSION TO MAKE THE REAL IMPROVEMENTS SPECIFIED AND AGREES TO DO ALL WORK IN STRICT COMPLIANCE WITH ALL CITY OF ORONO ORDINANCES AND STATE OF MINNESOTA BUILDING CODE REQUIREMENTS. APPLICANT PERMITEE SIGNATURE D BY SIGNATURE Conies: 1-File(Si-anitures Required), 1-Annlicant. 1-Monthlv Reports, 1-Assessin¢, 1-Finance Page 1 i CITY OF ORONO APPLICATION FOR MECHANICAL P Box 66 (2750 Kelley Parkway) �!/ � Crystal Bay, MN 55323 CST A0 GENERAL INFORMATION i R ANO I. You may apply for mechanical permits by mail or in person at the City offices.Applications will be reviewed and a permit will be issued within two working days. 4 2. Permit cards will be sent by return mail after a review is completed. PERMITS ARE NOT VALID UNTIL YOU RECEIVE A PERMIT. WORK MUST NOT BEGIN UNTIL THE PERMIT CARD IS ' "� POSTED ON THE JOB SITE. t 3. Mechanical Designs-Complete calculations,details and specifications are required for each heating, ventilation, humidification-dehumidification,and air conditioning installation including heat loss/heat gain calculation, design temperatures, equipment ratings and identification as to type, manufacturer and model. Data shall be presented on form provided. Identification of and specifications for water heating - equipment shall also be provided. 4. When any new construction or remodeling is involved, a separate building permit must be obtained. 5. All work must be done in accordance with the Uniform Mechanical Code/State Building Code requirements. 6. All work must be inspected(rough-in and final). Call(952)24911600. 24-hour notice required. al. 7. House Heating Test Record must be submitted before fin .- Instructions Complete all items on this application. Compute the permit fee. Sign and date the certification. INCOMPLETE APPLICATIONS WILL NOT BE PROCESSED. If you have questions, call 249-4600. fik _y" ' Iew IN 16 a i r is JOB SITE: SLA-1—Too VuLOUZip: Owner's Name: Phone Number: Mailing Address: City: Zip: V0GT HEATING$AIR CONDITIONING 3260 GORHAMAVE. Contractor's Name: uISpARk Phone Number: Mailing Address' SALES 929.6767 SERVICE U9o.nnU City Zip: kgA'f;Ak i�Wttkr'C..+G'si .�'yw.yF+ f b f SYSTEM DESCRIPTION HEATING SYSTEMS Quantity: Make: Model: .' Fuel F Flue Size: Input BTUs: Output BTUs: CFM: COOLING SYSTEMS Quantity: Make: Model: Tons: H.Power F IEPLACES r Gas factory fireplace = •. _ ,.r Wood burning factory fireplace with flue 4, ' ° ❑ Wood Stove ❑ Wood stove with flue Brand Name Model No. VENTILATION No. Kitchen Exhaust duct recalculating cfin No. Bath Exhaust(must have duct outside) cfin No: Other Fans: Locations cfm; FUEL STORAGE(MUST BE APPROVED BY FIRE MARSHAL) r ❑ Installation or ❑Removal a. g? F-1 Fuel oil: gallons ❑ underground E] inside ❑outstde 0 LP Gas: gallons ❑ Other Gas opening 2 PERMIT FEE CALCULATIONS) 2002 State Statute ❑ Yes This Section Applies The replacement of a Residential fixture or appliance that meets all three of the following requirements: 1) Does not require modification to electrical or gas service. 2) Has a total cost of$500.00 or less; excluding the cost of the fixture or appliance: and 3) Is improved, installed or replaced by the homeowner or licensed contractor. Skip next section; Cost of Permit $ 15.00 State Surcharge$ .50 Mail-In Fee $ 1.50 If above does not apply, follow guidelines below: 1. Contract Price* is .0125%of job with a Minimum Fee of($35.00) ui( � x .0125 $ 156�51 (contract price) (minimum$35.00) 2. State Surcharge. ** Add the State Building Code Division a Minimum Fee of($ .50). "_�lx.0005 $ U '�-� (contract price) (minimum$.50) 3. Postale and Handling(Only mail-in applications) $ 1.50 4. TOTAL PERMIT FEE (Add lines 1-3 above) $ *CONTRACT PRICE or JOB COST means the actual or estimated dollar amount charged for the permitted work including materials,labor,profit,and other fixed costs. It is the amount to be charged to the customer for the work done.If any material, equipment,labor,or installation is furnished by the owner,tenant or any other party the reasonable market value of such items must be added to the estimated cost or contract price for permit fee purposes.In the event that there is a dispute on the amount of the job cost,the City may request the submission of a signed copy of the actual contract. **The STATE SURCHARGE is.0005 of the contract price under$1,000,000 or$.50-whichever is greater.For valuations over $1,000,000 call the Department of Inspectional Services for the price. The undersigned hereby applies to the City for issuance of a Mechanical Permit,agrees to do all work in strict accordance with the ordinances of the City and the regulations of the Minnesota State Building Code,and certifies that all statements made on this application are complete,true and correct. Applicant's Signature: (.del A,-a-3 ckX Date: -713016)3- . Approved By: Date: 3 Heating/Air Conditioning Commercial/Residential Job At: 847 Tonkawa Rd Orono, MN EQUIPMENT LIST One (1) Viesman WB2-15-60 200,000 btu '3oiler(natural gas) Two (2) Lennox 10ACC-024 2 ton each Air Conditioner One (1) Lennox 10ACC-36 3 ton Air Conditioner One Lennox LF24-45 45m unit heaters (natural gas) Two (2) Am30g3-70 air handlers One (1) AM30g3/4-90 air handler Two (2) 16x25 electronic air cleaners Two (2) Honeywell HE265B humidifiers Gas: 2 dryers, and 2 cook tops Venting: 2 dryers, 2 cook tops and 5 bath fans 3260 Gorham Avenue, Minneapolis, Minnesota 55426-4189 SALES 952 929-6767 SERVICE 952 929-4011 FAX 952 929-1764 Miscellaneous Report IN Winter: -16 0 50 72 0.00 Summer: 89 73 50 75 33.54 ME Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft. Minimum Velocity: 650 ft./min 450 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 8 in. 6 in. Maximum Height: 12 in. 8 in. ' Winter Summer Infiltration: 0.700 AC/hr 0.400 AC/hr Volume of Conditioned Space: X 71467 Cu.ft. X 71467 Cu.ft. 50,027 Cu.ft./hr 28,587 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 834 CFM 476 CFM Total Building Ventilation: 50 CFM 50 CFM --System 1--- Infiltration &Ventilation Sensible Gain Multiplier: 14.94 = (1.10 X 0.970 X 14.00 Summer Temp. Difference) Infiltration &Ventilation Latent Gain Multiplier: 22.13 = (0.68 X 0.970 X 33.54 Grains Difference) Infiltration &Ventilation Sensible Loss Multiplier. 93.92 = (1.10 X 0.970 X 88.00 Winter Temp. Difference) C:\Elite\Rhvacw\Projects\Vaillant Residence.rhv Wednesday, July 23, 2003, 2:21 PM ProjectReport Project Filename: C:\Elite\Rhvacw\Projects\Vaillant Residence.rhv Project Title: Vallant Residences Designed By: Jim Vogelsberg Project Date: Tuesday, July 22, 2003 Company Name: Vogt Heating &Air Conditioning Company Representative: Jim Vogelsberg Company Address: 3260 Gorham Ave Company City: Saint Louis Park, Mn 55426 Company Phone: 952-929-6767 Company Fax: 952-929-1764 Company E-Mail Address: jimvogelsberg@serviceexperts.com Reference City: Minneapolis, Minnesota Daily Temperature Range: Medium Latitude: 44 Degrees Elevation: 834 ft. Altitude Factor: 0.970 Elevation Sensible Adj. Factor: 1.000 Elevation Total Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Dry Bulb Difference Winter: -16 - 0 0 72 0 Summer: 89 73 50 75 34 Total Building Supply CFM: 3,279 (2.8 AC/hr) CFM Per Square ft.: 0.467 Square ft. of Room Area: 7,022 Square ft. Per Ton: 893 Total Heating Required With Outside Air: 186,469 Btuh 186.469 MBH Total Sensible Gain: 70,741 Btuh 85 % Total Latent Gain: 12,801 Btuh 15 % Total Cooling Required With Outside Air: 83,542 Btuh 6.96 Tons(Based On Sensible + Latent) 7.86 Tons(Based On 75% Sensible Capacity) Calculations;re­;;;;; on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\Elite\Rhvacw\Projects\Vaillant Residence.rhv Wednesday, July 23, 2003, 2:21 PM Load Preview Report Building 7,022 70,741 12,801 83,542 186,469 2,433 3,279 3,279 MEME System 1 7,022 70,741 12,801 83,542 186,469 2,433 3,279 3,279 56x12 Zone 1 1,727 21,842 2,367 24,209 46,405 621 1,023 1,023 1-Shawn's Office 206 5,086 555 5,641 8,410 113 238 286 238 3-6 2-Dennis's Office 332 8,552 928 9,480 15,210 204 401 481 401 4-6 3-Cpoy/Powder/Stairs 408 2,265 118 2,383 5,961 80 106 106 106 1-6 4-Stairs 138 788 39 827 2,893 39 37 37 37 1-6 5-Living 341 2,350 314 2,664 7,820 105 110 110 110 2-6 6-Bath 1 100 415 52 467 1,652 22 19 19 19 1-6 7-Bedroom 1 202 2,386 361 2,747 4,459 60 112 112 112 2-6 Zone 2 2,218 39,558 6,810 46,368 93,125 1,247 1,853 1,853 8-Master Bedroom 434 4,781 1,394 6,175 13,477 180 224 224 224 3-6 9-Great 624 7,780 1,614 9,394 22,449 300 364 364 364 4-6 10-Dining/Kitchen 114 6,281 738 7,019 11,136 149 294 294 294 3-6 11-Sitting 173 8,815 1,307 , 10,122 16,736 224 413 413 413 4-6 12-Laundry/Bath/Mud 330 5,223 640 5,863 11,114 149 245 306 245 3-6 13-Foyer/Stairs 120 3,099 784 3,883 10,204 137 145 170 145 2-6 14-Powder 51 466 52 518 1,258 17 22 22 22 1-6 15-Closet 183 1,103 98 1,201 3,291 44 52 52 52 1-6 16-Master Bath 189 2,010 183 2,193 3,460 46 94 118 94 1-6 Zone 3 3,077 8,594 2,517 11,111 42,243 565 403 403 17-Exercise 506 2,283 653 2,936 10,461 140 107 107 107 1-6 18-Entertainment 575 3,214 810 . 4,024 11,059 148 151 151 151 2-6 19-Bedroom 1 298 2,797 824 3,621 10,425 140 131 131 131 2-6 20-Baths 324 0 0 0 1,761 24 0 0 0 0-0* 21-Guest Bedroom 238 300 230 530 1,445 19 14 14 14 1-6 22-Mechanical 360 0 0 0 2,236 30 0 0 0 0-0* 23-Kitchenette 364 0 0 0 1,829 24 0 0 0 0-0* 24-Bath/Laundry/Mech 412 0 0 0 3,027 41 0 0 0 0-0* C:\Elite\Rhvacw\Projects\Vaillant Residence.rhv Wednesday, July 23, 2003, 2:21 PM I Total Building Summary Loads 3D Window Double Pane Low Emit Wood Frame 1116 35,467 0 40,350 40,350 8P Glass Door Double Low a Wood Frame 354 11,240 0 11,198 11,198 11E Door Metal Urethane Core 144 2,406 0 482 482 12H Wall R-19 + 1/2"Gypsum Board(R-0.5) 5320 28,092 0 5,617 5,617 15C Wall 2-5'Below Grade 8/12" BIk+R-11 870 3,903 0 0 0 I 15G Wall 5'or More Below Grade 8/12" BIk+R-11 1240 4,693 0 0 0 161 Ceiling Under Vent. Attic-R-44 Insulation 3862 7,816 0 3,376 3,376 20E Floor Over Open Crawl Hardwood + R-30 100 326 0 33 33 201 Floor Over Open Crawl Carpet+ R-19 352 1,487 0 152 152 20J Floor Over Open Crawl Carpet+ R-30 543 1,672 0 171 171 21A Basemt Floor 2'or More Below Grade 1698 3,586 0 0 0 22C Slab on Grade 11/2" Edge Insulation R-8 -117 2,77900 0 Subtotals for structure: 103,467 0 61,379 61,379 People: 5 1,150 1,500 2,650 Equipment: 0 0 0 Lighting: 0 0 0 Ductwork: 0 0 0 0 Infiltration: Winter CFM: 834, Summer CFM: 476 78,306 10,544 7,115 17,659 Ventilation: Winter CFM: 50, Summer CFM: 504,696 1,107 747 1,854 --............-- ---._.................._.-... - Sensible Gain Total: 70,741 I Temperature Swing Multiplier: _ _ _ _ _ _ X 1.00 _ Total Building Load Totals: 186,469 12,801 70,741 83,542 Total Building Supply CFM: 3,279 (2.8 AC/hr) CFM Per Square ft.: 0.467 Square ft. of Room Area: 7,022 Square ft. Per Ton: 893 Total Heating Required With Outside Air: 186,469 Btuh 186.469 MBH Total Sensible Gain: 70,741 Btuh 85 % Total Latent Gain: 12,801 Btuh 15 % Total Cooling Required With Outside Air: 83,542 Btuh 6.96 Tons (Based On Sensible+ Latent) 7.86 Tons (Based On 75% Sensible Capacity) Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\Elite\Rhvacw\Projects\Vaillant Residence.rhv Wednesday, July 23, 2003, 2:21 PM System 1 Summary Loads s! ilmliziiiiiii i 3D Window Double Pane Low Emit Wood Frame 1116 35,467 0 40,350 40,350 8P Glass Door Double Low a Wood Frame 354 11,240 0 11,198 11,198 11E Door Metal Urethane Core 144 2,406 0 482 482 12H Wall R-19 + 1/2" Gypsum Board(R-0.5) 5320 28,092 0 5,617 5,617 15C Wall 2-5' Below Grade 8/12" BIk+R-11 870 3,903 0 0 0 15G Wall 5'or More Below Grade 8/12" BIk+R-11 1240 4,693 0 0 0 161 Ceiling Under Vent. Attic- R-44 Insulation 3862 7,816 0 3,376 3,376 20E Floor Over Open Crawl Hardwood + R-30 100 326 0 33 33 201 Floor Over Open Crawl Carpet+ R-19 352 1,487 0 152 152 20J Floor Over Open Crawl Carpet+ R-30 543 1,672 0 171 171 21A Basemt Floor 2'or More Below Grade 1698 3,586 0 0 0 22C Slab on Grade 11/2" Edge Insulation(R-8) _ 117 2,779 0 0 0 Subtotals for structure: 103,467 0 61,379 61,379 People: 5 1,150 1,500 2,650 Equipment: 0 0 0 Lighting: 0 0 0 Ductwork: 0 0 0 0 Infiltration: Winter CFM: 834, Summer CFM: 476 78,306 10,544 7,115 17,659 Ventilation: Winter CFM: 50, Summer CFM: 50 4,696 1,107 747 1,854 Sensible Gain Total: 70,741 Temperature Swing Multiplier:_- _ _ _ X 1.00 System 1 Load Totals: 186,469 12,801 70,741 83,542 Supply CFM: 3,279 (2.8 AC/hr) CFM Per Square ft.: 0.467 Square ft. of Room Area: 7,022 Square ft. Per Ton: 893 Total Heating Required With Outside Air: 186,469 Btuh 186.469 MBH Total Sensible Gain: 70,741 Btuh 85 % Total Latent Gain: 12,801 Btuh 15 % Total Cooling Required With Outside Air: 83,542 Btuh 6.96 Tons (Based On Sensible+ Latent) 7.86 Tons (Based On 75% Sensible Capacity) Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\Elite\Rhvacw\Projects\Vaillant Residence.rhv Wednesday, July 23, 2003, 2:21 PM S 'stem1, Zone 1 Summary Loads 3D Window Double Pane Low Emit Wood Frame 247 7,854 0 11,713 11,713 8P Glass Door Double Low a Wood Frame 80 2,540 0 3,888 3,888 12H Wall R-19 + 1/2" Gypsum Board(R-0.5) 2494 13,167 0 2,634 2,634 161 Ceiling Under Vent. Attic- R-44 Insulation 1727 3,495 0 1,510 1,510 20E Floor Over Open Crawl Hardwood + R-30 100 326 0 33 33 201 Floor Over Open Crawl Carpet+ R-19 352 1,487 0 152 152 20J Floor Over Open Crawl Carpet+ R-30 543 1,672 0 171 171 Subtotals for structure: 30,541 0 20,101 20,101 People: 1 230 300 530 Equipment: 0 0 0 Lighting: 0 0 0 Ductwork: 0 0 0 0 Infiltration: Winter CFM: 169, Summer CFM: 97 15,864 2,137 1,441 3,578 Sensible Gain Total: 21,842 Temperature Swing Multiplier: X 1.00 System 1, Zone 1 Load Totals: 46,405 2,367 21,842 24,209 Supply CFM: 1,023 (3.9 AC/hr) CFM Per Square ft.: 0.593 Square ft. of Room Area: 1,727 Square ft. Per Ton: 791 Total Heating Required: 46,405 Btuh 46.405 MBH. Total Sensible Gain: 21,842 Btuh 90 % Total Latent Gain: 2,367 Btuh 10 % Total Cooling Required: 24,209 Btuh 2.02 Tons(Based On Sensible+ Latent) 2.18 Tons(Based On 75% Sensible Capacity) Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\Elite\Rhvacw\Projects\Vaillant Residence.rhv Wednesday, July 23, 2003, 2:21 PM OR MOM System Zone_2 Summary Loads I 3D Window Double Pane Low Emit Wood Frame 694 22,055 0 25,030 25,030 8P Glass Door Double Low a Wood Frame 154 4,890 0 4,838 4,838 11E Door Metal Urethane Core 124 2,072 0 415 415 12H Wall R-19 + 1/2" Gypsum Board(R-0.5) 2391 12,628 0 2,524 2,524 161 Ceiling Under Vent.Attic=R-44_Insulation_._..___.._........____.._.._._._._.._._.__.._._._. 2135_.....__._..._._4,321 _.___..._..._........1,866 _ 1,866 Subtotals for structure: 45,966 0 34,673 34,673 People: 2 460 600 1,060 Equipment: 0 0 0 Lighting: 0 0 0 Ductwork: 0 0 0 0 Infiltration: Winter CFM: 502, Summer CFM: 287 __ 4.7,159 6,350 _4,28510,63_5_ Sensible Gain Total: 39,558 Temperature Swing Multiplier: _ _ X 1.00 System 1, Zone 2 Load Totals: 93,125 6,810 39,558 46,368 Supply CFM: 1,853 (4.4 AC/hr) CFM Per Square ft.: 0.836 Square ft. of Room Area: 2,218 Square ft. Per Ton: 511 Total Heating Required: 93,125 Btuh 93.125 MBH Total Sensible Gain: 39,558 Btuh 85 % Total Latent Gain: 6,810 Btuh 15 % Total Cooling Required: 46,368 Btuh 3.86 Tons(Based On Sensible+ Latent) 4.34 Tons(Based On 75% Sensible Capacity) Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\Elite\Rhvacw\Projects\Vaillant Residence.rhv Wednesday, July 23, 2003, 2:21 PM S stem 1, Zone 3 Summary Loads 3D Window Double Pane Low Emit Wood Frame 175 5,558 0 3,607 3,607 8P Glass Door Double Low a Wood Frame 120 3,810 0 2,472 2,472 11E Door Metal Urethane Core 20 334 _ 0 67 67 12H Wall R-19 + 1/2" Gypsum Board(R-0.5) 435 2,297 0 459 459 15C Wall 2-5' Below Grade 8/12" BIk+R-11 870 3,903 0 0 0 15G Wall 5'or More Below Grade 8/12" BIk+R-11 1240 4,693 0 0 0 21A Basemt Floor 2'or More Below Grade 1698 3,586 0 0 0- 22C Slab on Grade 11/2" Edge Insulation(R_8� — _ _ 1.1_7 2,779 0 0 0 Subtotals for structure: 26,960 0 6,605 6,605 People: 2 460 600 1,060 Equipment: 0 0 0 Lighting: 0 0 0 Ductwork: 0 0 0 0 Infiltration: Winter CFM: 163, Summer CFM: 93 15,283 2,057 _1,389 3,446 Sensible Gain Total: 8,594 TeTerature Swing Multiplier: X 1.00 System 1, Zone 3 Load Totals: 42,243 2,517 8,594 11,111 ELVIM Supply CFM: 403 (0.8 AC/hr) CFM Per Square ft.: 0.131 Square ft. of Room Area: 3,077 Square ft. Per Ton: 2,791 Total Heating Required: 42,243 Btuh 42.243 MBH Total Sensible Gain: 8,594 Btuh 77 % Total Latent Gain: 2,517 Btuh 23 % Total Cooling Required: 11,111 Btuh 0.93 Tons(Based On Sensible+ Latent) 1.10 Tons(Based On 75% Sensible Capacity) Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\Elite\Rhvacw\Projects\Vaillant Residence.rhv Wednesday, July 23, 2003, 2:21 PM System 1 Room Load Summar I ---Zone 1--- 1 Shawn's Office 206 8,410 113 3-6 405 5,086 555 238 1.20 286 238 2 Dennis's Office 332 15,210 204 4-6 510 8,552 928 401 1.20 481 401 3 Cpoy/Powder/Stair 408 5,961 80 1-6 540 2,265 118 106 1.00 106 106 s 4 Stairs 138 2,893 39 1-6 188 788 39 37 1.00 37 37 5 Living 341 7,820 105 2-6 280 2,350 314 110 1.00 110 110 6 Bath 1 100 1,652 22 1-6 99 415 52 19 1.00 19 19 7 Bedroom 1 202 4,459 60 2-6 285 2,386 361 112 1.00 112 112 Zone 1 subtotal 1,727 46,405 621 21,842 2,367 1,023 1,151 1,023 ---Zone 2-- 8 Master Bedroom 434 13,477 180 3-6 380 4,781 1,394 224 1.00 224 224 9 Great 624 22,449 300 4-6 464 7,780 1,614 364 1.00 364 364 10 Dining/Kitchen 114 11,136 149 3-6 500 6,281 738 294 1.00 294 . 294 11 Sitting 173 16,736 224 4-6 526 8,815 1,307 413 1.00 413 413 12 Laundry/Bath/Mud 330 11,114 149 3-6 415 5,223 640 245 1.25 306 245 13 Foyer/Stairs 120 10,204 137 2-6 370 3,099 784 145 1.17 170 145 14 Powder 51 1,258 17 1-6 111 466 52 22 1.00 22 22 15 Closet 183 3,291 44 1-6 263 1,103 98 52 1.00 52 52 16 Master Bath - 189 3,460 46 1-6 480 2,010 183 94 1.25 118 94 Zone 2 subtotal 2,218 93,125 1,247 39,558 6,810 1,853 1,963 1,853 ---Zone 3--- 17 Exercise 506 10,461 140 1-6 545 2,283 653 107 1.00 107 107 18 Entertainment 575 11,059 148 2-6 383 3,214 810 151 1.00 151 151 19 Bedroom 1 298 10,425 140 2-6 334 2,797 824 131 1.00 131 131 20 Baths 324 1,761 24 0-0 0 0 0 0 1.00 0 0 21 Guest Bedroom 238 1,445 19 1-6 72 300 230 14 1.00 14 14 22 Mechanical 360 2,236 30 0-0 0 0 0 0 1.00 0 0 23 Kitchenette 364 1,829 24 0-0 0 0 0 0 1.00 0 0 24 Bath/Laundry/Mec 412 3,027 41 0-0 0 0 0 0 1.00 0 0 h Zone 3 subtotal 3,077 42,243 565 8,594 2,517 403 403 403 System 1 total 7,022 186,46 2,433 70,741 12,801 3,279 3,517 3,279 9 System 1 Main Trunk Size: 56x12 in. Velocity: 889 ft./min Loss per 100 ft.: 0.051 in.wg MMININEEM Net Required: 6.96 85%/ 15% 70,741 12,801 83,542 Recommended: 7.86 75%/25% 70,741 23,580 94,321 Heating System Cooling System Type: Model: Brand: Efficiency: Sound: Capacity: Sensible Capacity: n/a 0 Btuh Latent Capacity: n/a 0 Btuh C:\Elite\Rhvacw\Projects\Vaillant Residence.rhv Wednesday, July 23, 2003, 2:21 PM 10/20/2013 04:13 FAX 9524710639 STONEWOOD 004/005 P%vulavow planes-VF P%jj P1lltilllauYO allu •tollulawll L^P�UllmlllauVll (Can be Used as a S upplement to Permit Application) Address: 847 Tonkawa Road Date: 7/15/2003 C Orono �Y� Zip Code: Completed By: Kevin Kamerud Co. Name:Stonewood Design Build, LLC Path 2, Aggregate Alternative Exhaust Devices CFM Space Heater. Sealed Combustion Clothes Dryer ry 150 Water Heater. Sealed Combustion _ Kitchen Exhaust 350 Gas Hearth: Direct Vented Master Bathroom 80 Solid Fuel Hearth: Decorative Bsmt Bathroom 80 i CO Alarm: Required i 1st R.Bathroom 80 I Make-Up Air Requirements _ Central vacuum Recirculati I Exhaust Devices Dryer Wtchen Largest `Excess Total Other Vent. Exhaust Capacity 150 0 0 159 309 *Powered make-up cfms required for exhaust supplemental ventilation in excess of 0.05 X total Sq. Ft.. Distribution CFM Passive Infiltration 0 Passive Opening(s) Rigid Flex Direct 175 10, 11 9 Powered Make-Up 134 Ventilation Mirdmum Required Sq. Ft. Sedrms Total Ventilation People Ventilation Supplemental Ventilation 8612 4 431 75 356 People _ Supplemental HRV or ERV 1 152 cfm. HRV or ERV 1 87 cfm. Kitchen Exhaust 0 cfm. Kitchen Exhaust 350 cfm. Master Bathroom 0 cfm. Master Bathroom 80 cfm. Bsmt Bathroom 0 cfm. Bsmt Bathroom 80 cfm. 1st R Bathroom 0 cfm. 1st FI Bathroom 80 cfm. Applicant(print name) Signature Date Phone number 10/20/2013 04:13 FAX 9524710639 STONEWOOD 12/005/005 V We 1urauvr i Owl traaurcr I Bei it,uwur 1101 iwuVn r Bldg Address: 1847 Tonkawa Road Data: eky: Orono Zip Code: t Completed By: Kevin Kamerud Co. Name:Stonewood Design Build,LLC Path 2, Aggregate Albemative co Alarm: Required Installed: Yes No Ventilation: Measured PerFomnance People Ventilation Supplemental Ventliation I Total Ventilation Minimums---> 75 356 i 431 �— Measured Measured People Designed Intake Exhaust Supplemental Designed Intake Exhaust HRV or ERV 1 152 cfm. HRV or ERV 1 87 cfm. 1 Kitchen Exhaust 0 cfm. Kitchen Exhaust 350 cfm. Master Bathroom 0 cfm. Master Bathroom 180 cfm. Bsmt Bathroom 0 cfm. Bsmt Bathroom 80 cfm. list FI Bathroom 0 cfm. 1st Fl Bathroom 80 cfm. People: 152 cfm. Supplemental: 1677 cfin. Note: Air flow for balanced ventilation systems must be balanced within ten percent. Compliance Statement:installed ventilation system Is in compliance with the MN Energy Code and sized to provide the design air flow. Applicant(print name) Signature Date Phone number