HomeMy WebLinkAbout2014-asbestos testing ' r LABURATURIES 1325 North 108th East Avenue Tulsa,OK 74116 un I E R T I F I G A I I O N TESTING INSPECTION 918-437-8333 ph. 1 918-437-8487 fx. Lc� CLIENT: Nova Industries 8011 North 154th East Ave Owasso, OK 74055 Test Report No: TJ 1768-4 Date: June 26, 2014 SAMPLE ID: Duct Armor SAMPLING DETAIL: Test samples were submitted to the laboratory directly by the client. No special sampling conditions or sample preparation were observed by QAI. DATE OF RECEIPT: Samples were received at QAI on April 22, 2014. TESTING PERIOD: 6/16/14 — 6/25/14 AUTHORIZATION: Signed Proposal Number SP060713-2 by Tim Borgne. TEST PROCEDURE: The units were evaluated in accordance with ASTM E 1494-12, Annex 1 (Test Method to Determine the Cohesion/Adhesion Properties of Friable Spray or Trowel Applied Asbestos-Containing Surfacing Materials). No revisions to this report will be allowed after 90 days of the report date. TEST RESULTS: The evaluated Duct Armor coating meets the requirements for "Encapsulated Surfacing Materials" as defined in Section 6 of ASTM E 1494-12.. PREPARED BY SIGNED FOR ON BEHALF OF QAI LABORATORIES INC. Rocky Hale Jarred L. Johnson Material Test Technician Quality Manager Page 1 of 3 THIS REPORT IS THE CONFIDENTIAL PROPERTY OF THE CLIENT ADDRESSED.THE REPORT MAY ONLY BE REPRODUCED IN FULL.PUBLICATION OF EXTRACTS FROM THIS REPORT IS NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM QAI.ANY LIABILITY ATTACHED THERETO IS LIMITED TO THE FEE CHARGED FOR THE INDIVIDUAL PROJECT FILE REFERENCED. THE RESULTS OF THIS REPORT PERTAIN ONLY TO THE SPECIFIC SAMPLE(S)EVALUATED. WWW.QAI.ORG info @qai.org t-.RWnL. IVuva IIIUUbU IWb Job No.: TJ1768-4 Date: June 26, 2014 LADWIM8 Page 2 of 3 Test Procedure and Results ASTM E 1494-12(Standard Practice for Encapsulation Testing of Friable Asbestos-Containing Surfacing Materials) Qualifications The test methods in this practice require disturbance of asbestos-containing materials. Activities that disturb asbestos containing materials are subject to regulations of the Occupational Safety and Health Administration (OSHA), the Environmental Protection Agency (EPA) and other jurisdictions including certain state agencies. The test method described in Annex Al to determine the adhesive and cohesive properties of encapsulated surfacing material can result in a release of asbestos-containing debris. Persons conducting this test must have the appropriate credentials and training to clean up the debris. i i Annex 1 (Test Method to Determine the Cohesion/Adhesion Properties of Friable Spray or Trowel Applied Asbestos-Containing Surfacing Materials) Test Preparation The Duct Armour product was troweled onto (4) 12" by 12" Hardie Panel Cement Backer Board. The product was allowed to cure in a 70°F/50% relative humidity environment for 24 hours. Gorilla Epoxy was prepared and placed on the surface of the Duct Armor coating and a 3° by 4° steel plate was placed on top of the epoxy with approximately 5 lbs of force. The assembly was allowed to cure for an additional 24 hours. Test Procedure The 12" by 12" assemblies were placed on the bottom of a universal tensile testing fixture. The panels were secured by placing W thick steel plates that over lapped the edges of the backer board panel by 3/4". The 3" by 4" steel plate adhered to the Duct Armor coating was then connected to the top of the universal test fixture. The rate of tension used for this testing was 1 in/ min. THIS REPORT IS THE CONFIDENTIAL PROPERTY OF THE CLIENT ADDRESSED.THE REPORT MAY ONLY BE REPRODUCED IN FULL.PUBLICATION OF EXTRACTS FROM THIS REPORT IS NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM QAI.ANY LIABILITY ATTACHED THERETO IS LIMITED TO THE FEE CHARGED FOR THE INDIVIDUAL PROJECT FILE REFERENCED. THE RESULTS OF THIS REPORT PERTAIN ONLY TO THE SPECIFIC SAMPLE(S)EVALUATED. WWW.QAI.ORG info(Pgai.org . lillClll. IVUVd IIHAJJUICJ Job No.: TJ1768-4 Date: June 26, 2014 uU►tDlp;e� Page 3 of 3 Results Duct Armor Encapsulated Samples Un-Encapsulated Samples �I Sample No. 1 2 3 4 1 2 3 4 Failure Point(Ibf) 409 313 345 203 413 86* 279 304 Failure Point(psi) 34.08 26.08 28.75 16.92 34.42 7.17* 23.25 25.33 Failure Point(Ibf/ft2) 4,908 3,756 4,140 2,436 4,956 1,032* 3,348 3,648 Duration of Test 8 sec. 2 sec. 4 sec. 3 sec. 6 sec. 2 sec. 9 sec. 5 sec. Failure Point Average(lbf/ft2) 3,810 3,984 *Sample was not used in the calculations due to exceeding the acceptable limits Sample Failure Description II� Duct Armor Encapsulated Sample 1 Cohesive Failure within Un-Encapsulated Material Duct Armor Encapsulated Sample 2 Cohesive Failure within Un-Encapsulated Material Duct Armor Encapsulated Sample 3 Cohesive Failure within Un-Encapsulated Material Duct Armor Encapsulated Sample 4 Cohesive Failure within Un-Encapsulated Material Un-Encapsulated Sample 1 Cohesive Failure within Un-Encapsulated Material Un-Encapsulated Sample 2 Cohesive Failure within Un-Encapsulated Material Un-Encapsulated Sample 3 Cohesive Failure within Un-Encapsulated Material Un-Encapsulated Sample 4 Cohesive Failure within Un-Encapsulated Material Requirements: The load required to cause adhesion or cohesion failure of the encapsulated matrix shall not be less than the load required to cause failure of the unencapsulated matrix, and in no case shall the load be less than 2.4 kPa (50 Ibf/ft2). �* END OF TEST REPORT*** THIS REPORT IS THE CONFIDENTIAL PROPERTY OF THE CLIENT ADDRESSED.THE REPORT MAY ONLY BE REPRODUCED IN FULL.PUBLICATION OF EXTRACTS FROM THIS REPORT IS NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM OAT.ANY LIABILITY ATTACHED THERETO IS LIMITED TO THE FEE CHARGED FOR THE INDIVIDUAL PROJECT FILE REFERENCED. THE RESULTS OF THIS REPORT PERTAIN ONLY TO THE SPECIFIC SAMPLE(S)EVALUATED. WWW.QAI.ORG info @qai.org LABORATORIES 1325 North 108th E.Ave. Tulsa,OK 74116 CERTIFICATION TESTING INSPECTION 918.437.8333 ph. 1918.437.8487tx. CLIENT: Nova Industries 8011 North 154th East Avenue Owasso, OK 74055 Attn: Tim Borgne Test Report No: TJ1409 -7Date:July 23, 2013 SAMPLE ID: The client submitted and identified the following test material as "Duct Armor" SAMPLING DETAIL: Test samples were submitted to the laboratory directly by the client. No special sampling conditions or sample preparation were observed by QAI. DATE OF RECEIPT: Samples were received at QAI on 6/20/13 TESTING PERIOD: July 1, 2013 AUTHORIZATION: Signed Proposal No. SP060713-2 TEST REQUEST®: Perform standard flame spread and smoke density developed classification tests on the sample supplied by the Client in accordance with ASTM E2768-11 "Standard Test Method for Extended Duration Surface Burning Characteristics of Building Materials 30 min Tunnel Test). This method is similar to UBC No. 8-1 per Chapter 7A of the 2001 California Building Code, Ignition-Resistant Material 30 minute test TEST RESULTS: Flame Spread Smoke Developed 10@10:00 30@10:00 Detailed test results are presented in the subsequent pages of this report PREPARED BY SIGNED FOR AND ON BEHALF OF QAI LABORATORIES, INC. David Bauchmoyer J. Brian McDonald Fre Test Technician Operations Manager Page 1 of 3 THIS REPORT IS THE CONFIDENTIAL PROPERTY OF THE CLIENT ADDRESSED.THE REPORT MAY ONLY BE REPRODUCED IN FULL.PUBLICATION OF EXTRACTS FROM THIS REPORT IS NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM QAI.ANY LIABILITY ATTACHED THERETO IS LIMITED TO THE FEE CHARGED FOR THE INDIVIDUAL PROJECT FILE REFERENCED. THE RESULTS OF THIS REPORT PERTAIN ONLY TO THE SPECIFIC SAMPLE(S)EVALUATED. WWW.QAI.ORG info@gai.org . y II Nova Industries Inc. Report No.:TJ1409 July 23,2013 Page 2 of 3 E 84 TEST DATA SHEET: CLIENT: Nova Industries DATE: July 1, 2013 SAMPLE: Duct Armor FLAME SPREAD: IGNITION: 3 Min. and 3 Sec. FLAME FRONT: 4 feet maximum TIME TO MAXIMUM FLAME SPREAD: 4 feet at 6 minutes TEST DURATION: 10 minutes SUMMARY: FLAME SPREAD: 10 @ 10:00 SMOKE DEVELOPED: 30 @110:00 SUMMARY OF ASTM EB4 RESULTS: Because of the possible variations in reproducibility, the results are adjusted to the nearest figure divisible by 5. Smoke Density values over 200 are rounded to the nearest figure divisible by 50. In order to obtain the Flame Spread Classification, the above results should be compared to the following table: NEPA CLASS IBC CLASS FLAME SPREAD SMOKE DEVELOPED A A 0 through 25 Less than or equal to 450 B B 26 through 75 Less than or equal to 450 C C 76 through 200 Less than or equal to 450 BUILDING CODES CITED: 1. National Fire Protection Association, ANSI/NFPA No. 101, "Life Safety Code", 2006 Edition. 2. International Building Code, 2006 Edition, Chapter 8, Interior Finishes, Section 803. THIS REPORT IS THE CONFIDENTIAL PROPERTY OF THE CLIENT ADDRESSED.THE REPORT MAY ONLY BE REPRODUCED IN FULL.PUBLICATION OF EXTRACTS FROM THIS REPORT IS NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM OAI.ANY LIABILITY ATTACHED THERETO IS LIMITED TO THE FEE CHARGED FOR THE INDIVIDUAL PROJECT FILE REFERENCED. THE RESULTS OF THIS REPORT PERTAIN ONLY TO THE SPECIFIC SAMPLE(S)EVALUATED. WWW.QAI.ORG info Ogai.org Nova Industries Inc. Report No.:TJ1409 July 23,2013 Page 3 of 3 Flame Spread Chart 23 Test AS Samp d a m Q °J3 A e ms 3 u en Tsne(Minutes) Smoke Developed Chart Test 100 Semple 80 c80 0 z a `o a i40 i r a J 20 0 ----' - - - - ._- - 0 1 2 3 4 5 8 7 8 9 10 Time(minutes) Temperature-Time Curve 1250 Test Sample 1050 850 LL _ m --------.-------- •-_• Y - _-•----- -------- C 2650 0 r 250 50 Time(minutes) END OF REPORT THIS REPORT IS THE CONFIDENTIAL PROPERTY OF THE CLIENT ADDRESSED.THE REPORT MAY ONLY BE REPRODUCED IN FULL.PUBLICATION OF EXTRACTS FROM THIS REPORT IS NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM QAI.ANY LIABILITY ATTACHED THERETO IS LIMITED TO THE FEE CHARGED FOR THE INDIVIDUAL PROJECT FILE REFERENCED. THE RESULTS OF THIS REPORT PERTAIN ONLY TO THE SPECIFIC SAMPLE(S)EVALUATED. VVM.QAI.ORG infb9gai.org A LABUKATURILS 1325 North 108th East Avenue CERTIFICATION TESTING INSPECTION Tulsa,OK 74116 918-437-8333 ph. 1 918-437-8487 fx. CLIENT: Nova Industries 8011 North 154th East Ave Owasso, OK 74055 Test Report No:TJ 1768-4 Date: June 26, 2014 SAMPLE ID: Duct Armor SAMPLING DETAIL: Test samples were submitted to the laboratory directly by the client. No special samplin conditions or sample preparation were observed by QAI. DATE OF RECEIPT: Samples were received at QAI on April 22, 2014. TESTING PERIOD: 6/16/14—6/25/14 AUTHORIZATION: Signed Proposal Number SP060713-2 by Tim Borgne. TEST PROCEDURE:The units were evaluated in accordance with ASTM E 1494-12, Annex 1 (Test Method to Determine the Cohesion/Adhesion Properties of Friable Spray or Trowel Applie Asbestos-Containing Surfacing Materials). No revisions to this report will be allowe after 90 days of the report date. TEST RESULTS: The evaluated Duct Armor coating meets the requirements for"Encapsulated Surfacing Materials" as defined in Section 6 of ASTM E 1494-12.. PREPARED BY SIGNED FOR ON BEHALF OF QAI LABORATORIES INC. r Rocky Hale Jarred L. Johnson Material Test Technician Quality Manager Pae 1 of 3 THIS REPORT IS THE CONFIDENTIAL PROPERTY OF THE CLIENT ADDRESSED.THE REPORT MAY ONLY BE REPRODUCED IN FULL.PUBLICATION OF EXTRACTS FROM THIS REPORT IS NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM QAI.ANY LIABILITY ATTACHED THERETO IS LIMITED TO THE FEE CHARGED FOR THE INDIVIDUAL PROJECT FILE REFERENCED. THE RESULTS OF THIS REPORT PERTAIN ONLY TO THE SPECIFIC SAMPLE(S)EVALUATED. VVM.QAI.ORG info @qai.org Client: Nova Industries Job No.: TJ1768-4 Date: June 26, 2014 usOI Page 2 of 3 Test Procedure and Results ASTM E 1494-12(Standard Practice for Encapsulation Testing of Friable Asbestos-Containing Surfacing Materials) Qualifications The test methods in this practice require disturbance of asbestos-containing materials. Activities that disturb asbestos containing materials are subject to regulations of the Occupational Safety and Health Administration (OSHA), the Environmental Protection Agency (EPA) and other jurisdictions including certain state agencies. The test method described in Annex Al to determine the adhesive and cohesive properties of encapsulated surfacing material can result in a release of asbestos-containing debris. Persons conducting this test must have the appropriate credentials and training to clean up the debris. Annex 1 (Test Method to Determine the Cohesior✓Adhesion Properties of Friable Spray or Trowel Applied Asbestos-Containing Surfacing Materials) Test Preparation The Duct Armour product was troweled onto (4) 12° by 12" Hardie Panel Cement Backer Board. The product was allowed to cure in a 70°F/50% relative humidity environment for 24 hours. Gorilla Epoxy was prepared and placed on the surface of the Duct Armor coating and a 3" by 4" steel plate was placed on top of the epoxy with approximately 5 lbs of force. The assembly was allowed to cure for an additional 24 hours. Test Procedure The 12" by 12" assemblies were placed on the bottom of a universal tensile testing fixture. The panels were secured by placing W thick steel plates that over lapped the edges of the backer board panel by$/". The 3" by 4" steel plate adhered to the Duct Armor coating was then connected to the top of the universal test fixture. The rate of tension used for this testing was 1 in/min. THIS REPORT IS THE CONFIDENTIAL PROPERTY OF THE CLIENT ADDRESSED.THE REPORT MAY ONLY BE REPRODUCED IN FULL.PUBLICATION OF EXTRACTS FROM THIS REPORT IS NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM QAI.ANY LIABILITY ATTACHED THERETO IS LIMITED TO THE FEE CHARGED FOR THE INDIVIDUAL PROJECT FILE REFERENCED. THE RESULTS OF THIS REPORT PERTAIN ONLY TO THE SPECIFIC SAMPLE(S)EVALUATED. WWW.QAI.ORG info@gai.org Client: Nova Industries Job No.: TJ1768-4 Date: June 26, 2014 uwtas Page 3 of 3 I Results I I Duct Armor Encapsulated Samples Un-Encapsulated Samples Sample No. 1 2 3 4 1 2 3 4 Failure Point(lbf) 409 313 345 203 413 86* 279 304 Failure Point(psi) 34.08 26.08 28.75 16.92 34.42 7.17* 23.25 25.33 Failure Point(Ibf/ft2) 4,908 3,756 4,140 2,436 4,956 1,032* 3,348 3,648 Duration of Test 8 sec. 1 2 sec. 4 sec. 3 sec. 6 sec. 1 2 sec. 1 9 sec. 5 sec. Failure Point Average(lbf/ft2) 3,810 3,984 *Sample was not used in the calculations due to exceeding the acceptable limits Sample Failure Description Duct Armor Encapsulated Sample 1 Cohesive Failure within Un-Encapsulated Material Duct Armor Encapsulated Sample 2 Cohesive Failure within Un-Encapsulated Material Duct Armor Encapsulated Sample 3 Cohesive Failure within Un-Encapsulated Material Duct Armor Encapsulated Sample 4 Cohesive Failure within Un-Encapsulated Material Un-Encapsulated Sample 1 Cohesive Failure within Un-Encapsulated Material Un-Encapsulated Sample 2 Cohesive Failure within Un-Encapsulated Material Un-Encapsulated Sample 3 Cohesive Failure within Un-Encapsulated Material Un-Encapsulated Sample 4 Cohesive Failure within Un-Encapsulated Material Requirements: The load required to cause adhesion or cohesion failure of the encapsulated matrix shall not be less than the load required to cause failure of the unencapsulated matrix, and in no case shall the load be less than 2.4 kPa (50 Ibffft2). II * END OF TEST REPORT**" I I I THIS REPORT IS THE CONFIDENTIAL PROPERTY OF THE CLIENT ADDRESSED.THE REPORT MAY ONLY BE REPRODUCED IN FULL.PUBLICATION OF EXTRACTS FROM THIS REPORT IS NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM QAI.ANY LIABILITY ATTACHED THERETO IS LIMITED TO THE FEE CHARGED FOR THE INDIVIDUAL PROJECT FILE REFERENCED. THE RESULTS OF THIS REPORT PERTAIN ONLY TO THE SPECIFIC SAMPLE(S)EVALUATED. WWW.QAI.ORG info @qai.org LABORATORIES �1325 Noah 1h E.AVB. Tulsa,OK 74116 CERTIFICATION TESTING INSPECTION 918.437.6333 ph. 1918.437.6467fx. CLIENT: Nova Industries 8011 North 154th East Avenue Owasso, OK 74055 Attn: Tim Borgne Test Report No:TJ1409 Date:July 23, 2013 SAMPLE ID: The client submitted and identified the following test material as "Duct Armor" SAMPLING DETAIL: Test samples were submitted to the laboratory directly by the client. No special sampling conditions or sample preparation were observed by QAI. DATE OF RECEIPT: Samples were received at QAI on 6/20/13 TESTING PERIOD: July 1, 2013 AUTHORIZATION: Signed Proposal No. SP060713-2 TEST REQUESTED: Perform standard flame spread and smoke density developed classification tests on the sample supplied by the Client in accordance with ASTM E2768-11 "Standard Test Method for Extended Duration Surface Burning Characteristics of Building Materials 30 min Tunnel Test). This method is similar to UBC No. 8-1 per Chapter 7A of the 2001 California Building Code, Ignition-Resistant Material 30 minute test TEST RESULTS: Flame Spread Smoke Developed 10@10:00 30@10:00 Detailed test results are presented in the subsequent pages of this report PREPARED BY SIGNED FOR AND ON BEHALF OF GA LABORATORIES, INC. David Bauchmoyer J. Brian McDonald Fre Test Technician Operations Manager Page 1 of 3 THIS REPORT IS THE CONFIDENTIAL PROPERTY OF THE CLIENT ADDRESSED.THE REPORT MAY ONLY BE REPRODUCED IN FULL.PUBLICATION OF EXTRACTS FROM THIS REPORT IS NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM QAI.ANY LIABILITY ATTACHED THERETO IS LIMITED TO THE FEE CHARGED FOR THE INDIVIDUAL PROJECT FILE REFERENCED. THE RESULTS OF THIS REPORT PERTAIN ONLY TO THE SPECIFIC SAMPLE(S)EVALUATED. WWW.QAI.ORG info@gai.org Nova Industries Inc. Report No.:TJ1409 Q01 July 23,2013 Page 2 of 3 E 84 TEST DATA SHEET: CLIENT: Nova Industries DATE July 1 . 2013 SAMPLE: Duct Armor FLAME SPREAD: IGNITION: 3 Min. and 3 Sec. FLAME FRONT: 4 feet maximum TIME TO MAXIMUM FLAME SPREAD: 4 feet at 6 minutes TEST DURATION: 10 minutes SUMMARY: FLAME SPREAD: 10 @ 10:00 SMOKE DEVELOPED: 30 @ 10:00 SUMMARY OF ASTM 8B4 RESULTS: Because of the possible variations in reproducibility, the results are adjusted to the nearest figure divisible b 5. Smoke Density values over 200 are round � g y y ed to the nearest figure divisible by 50. In order to obtain the Flame Spread Classification, the above results should be compared to the following table: NEPA CLASS IBC CLASS FLAME SPREAD SMOKE DEVELOPED A A 0 through 25 Less than or equal to 450 B B 26 through 75 Less than or equal to 450 C C 76 through 200 Less than or equal to 450 BUILDING CODES CITED: 1. National Fre Protection Association, ANSI/NFPA No. 101, "Life Safety Code", 2006 Edition. 2. International Building Code, 2006 Edition, Chapter 8, Interior Finishes, Section 803. THIS REPORT IS THE CONFIDENTIAL PROPERTY OF THE CLIENT ADDRESSED.THE REPORT MAY ONLY BE REPRODUCED IN FULL.PUBLICATION OF EXTRACTS FROM THIS REPORT IS NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM QAI.ANY LIABILITY ATTACHED THERETO IS LIMITED TO THE FEE CHARGED FOR THE INDIVIDUAL PROJECT FILE REFERENCED. THE RESULTS OF THIS REPORT PERTAIN ONLY TO THE SPECIFIC SAMPLE(S)EVALUATED. VVM.QAI.ORG info @qai.org Nova Industries Inc. Report No.:TJ1409 July 23,2013 Page 3 of 3 un — I i Flame Spread Chart 23 Teat ' Sempl � ------------------------------ 13 ' ----- ------- 13 9 m a e8 E IL 3 tsut. Imre(Minutes) Smoke Developed Chart Test 100 Semple 80 e co a a � I Q4 J 20 -- ------- --- ----- _ ------- ------ ----- --------- 0 0 1 2 3 4 5 8 7 8 9 10 Time(minutes) Temperature -Time Curve 1250 -Test Sample 1050 850 e� --------- '1!$50 b fig-l50 0 F 250 50 Time(minutes) END OF REPORT THIS REPORT IS THE CONFIDENTIAL PROPERTY OF THE CLIENT ADDRESSED.THE REPORT MAY ONLY BE REPRODUCED IN FULL.PUBLICATION OF EXTRACTS FROM THIS REPORT IS NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM QAI.ANY LIABILITY ATTACHED THERETO IS L9dITED TO THE FEE CHARGED FOR THE INDIVIDUAL PROJECT FILE REFERENCED. THE RESULTS OF THIS REPORT PERTAIN ONLY TO THE SPECIFIC SAMPLE(S)EVALUATED. VVM.QAI.ORG info Ogai.org c c SERVICEICC EVALUATION WidelyMost [MES PMG Listing PMG-1043 Effective Date:January 1, 2011 This listing is subject to re-examination in one year. www.icc-es-Pmg.om 1 (800)423-6587 (562)699-0543 A Subsidiary of the Intemational Code Councile CSI: DIVISION: 23 00 00—HEATING, VENTILATING AND AIR-CONDITIONING (HVAC) Section: 23 31 00—HVAC Ducts and Casings Product certification system: The ICC-ES product certification system includes testing samples taken from the market or suppliers stock, or a combination of both, to verify compliance with applicable codes and standards. The system also involves factory inspections, and assessment and surveillance of the supplier's quality system Product: EnvirolinerTm Listee: DSTTM, Duct Seal Technologies, LLC 8011 N. 154 East Ave Owasso, Oklahoma 74055 www.ductsealtechnologies.com www.rustvducts.com Compliance with the following codes: 2009 Intemational Residential Code®(IRC) 2009 Intemational Mechanical Codee(IMC) 2009 IAPMO Uniform Mechanical Codee(IAPMO UMC)- Unifo►rn Mechanical Code is a copyrighted publication of the International Association of Plumbing and Mechanical Officials, 5001 East Philadelphia Street,Ontario,California 91761. Compliance with the following standards: ASTM E 84, Standard Test Method for Surface Burning Characteristics of Building Materials LC1014, PMG Listing Criteria for Underground Plastic Air Ducts Identification: The DSTTM' system of applying an internal coating to underground noncombustible (concrete or metal) duct systems, as described in this listing, is identified by a sticker or plate attached to the HVAC indoor unit bearing the manufacturer's name(DSTTM', LLC), product name(Envirolinerrm)and the ICC-ES PMG listing mark. The ICC-ES PMG listing mark must be placed on the listed product's packaging or installation instructions. Installation: Installation must comply with the manufacturer's published installation instructions and the applicable codes. Listings are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the listing or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,as to 14tiL+L any finding or other matter in this listing,or as to any product covered by the listing. Copyright 0 2011 Page 1 of 2 PMG-1043 1 Most Widely Accepted and Trusted Page 2 of 2 The DSTTm system is a proprietary coating spray-applied to the interior of sound, existing, underground noncombustible (concrete or metal) ductwork in accordance with the manufacturer's proprietary process by installers trained and certified by the manufacturer. When tested according to ASTM E 84 at a 0.025-inch thickness (0.635 mm), the material demonstrated a maximum flame spread index of 45 and a maximum smoke developed index of 35. Laboratory analysis provided indicated Envirolinerlm has the same or lower ASTM E 84 characteristics as materials allowed for underground ducts in IRC M1601.1.2 and IMC Section 603.8, and as an alternate under UMC Section 105. The existing underground ductwork must have been installed in accordance with the applicable code, and be in sound condition. Conditions of Listing: 1. Designs using EnvirolinerTm must be limited to underground air duct systems with a maximum air temperature of 150°F (66`C) at the discharge of the unit entering the duct system. Duct sizing must be in accordance with the applicable code. 2. EnvirolinerTm coatings must be installed on ducts which are either underground or embedded within concrete slabs. The duct must not be used in exposed or aboveground applications. 3. The existing uncoated air duct system must have been sized and installed in accordance with the applicable code. 4. The DSTTm EnvirolinerTm is manufactured under a quality control program with annual surveillance inspections by ICC-ES.