Loading...
HomeMy WebLinkAbout2003-P07117 - mechanical _ C!� Y OF O RO N O PERMIT Permit Number: 275 Kelley Parkway- PO Box 66 P07117 Crystal Bay, Minnesota 55323 Permit Type: Mechanical Permits (952) 2494600 Date Issued: 12/19/2003 SITE ADDRESS: 680 Tonkawa Rd Long Lake,MN 55356 PID: 05-117-23-33-0010 DESCRIPTION: Proposed Use: Residential Permit Class: General Permit Sub-type(s): Multiple Mechanical Items Permit Type: Mechanical Permits DETAILS: Approved per resolution#: Separate permits required: NOTICES/REMARKS: FEE SUMMARY: Permit Fee: $ 125.00 Valuation: $ 10,000.00 State Surcharge Fee: $ 5.00 Misc.Fee: $ 1.50 TOTAL FEE: $ 131.50 APPLICANT: Plymouth Plumbing&Heating OWNER: Melinda Lee 12270 43rd Street NE 680 Tonkawa Rd St.Micheal,MN 55376 Long Lake MN 55356 THE UNDERSIGNED HEREBY REQUESTS PERMISSION TO MAKE THE REAL IMPROVEMENTS SPECIFIED AND AGREES TO DO ALL WORK IN STRICT COMPLIANCE WITH ALL CITY OF ORONO ORDINANCES AND STATE OF MINNESOTA BUILDING CODE REQUIREMENTS. ice `hc.dt.�e a-r' APPLICANT PERMITEE SIGNATURE SSUED BY SIGNATURE Copies: 1-File(Signitures Required), 1-Applicant, 1-Monthlv Reports, 1-Assessine, 1-Finance Page 1 CITY OF ORONO APPLICATION FOR MECHANICAL PERMIT Box 66 (2750 Kelley Parkway) Crystal Bay, MN 55323 GENERAL INFORMATION 1. You may apply for mechanical permits by mail or in person at the City offices. Applications will be reviewed and a permit will be issued within 2 working days. 2. Permit cards will be sent by return mail after a review is completed. PERMITS ARE NOT VALID UNTIL YOU RECEIVE A PERMIT. WORK MUST NOT BEGIN UNTIL THE PERMIT CARD IS POSTED ON THE JOB SITE. 3. Mechanical Desians - Complete calculations, details and specifications are required for each heating, ventilation, humidification-dehumidification, and air conditioning installation including heat loss/heat gain calculation, design temperatures, equipment ratings and identification as to type, manufacturer and model. Data shall be presented on form provided. Identification of and specifications for water heating equipment shall also be provided. 4. When any new construction or remodeling is involved, a separate building permit must be obtained. 5. All work must be done in accordance with the Uniform Mechanical Code/State Building Code requirements. 6. All work must be inspected(rough-in and final). Call 249-4600. 24-hour notice required. 7. House Heating Test Record must be submitted before final. Instructions Complete all items on this application. Compute the permit fee. Sign and date the certification. INCOMPLETE APPLICATIONS WILL NOT BE PROCESSED. If you have questions, call 249-4600. Please check one: 1, New Addition Repair Replace Residential Commercial JOB SITE: O ,�(.wc� Zip: Owner's Name: Telephone Number: Mailing Address: City: Zip: Contractor's Name:PI a M ;&A qt Telephone Number to )b,;3 3-U M-7 Mailing Address: ( Q �, ; r,,K {-V7�, , �, City: Zip: 5 SYSTEM DESCRIPTION HEATING SYSTEMS Quantity: n/ Make: _ Model: Fuel: Flue Size: Input BTUs: T Output BTUs: CFM: COOLING SYSTEMS Quantity: at Make: -P—Yl no'r= Model: C 40 Tons: H. Power FIREPLACES Gas factory fireplace Wood burning factory fireplace with flue Wood Stove Wood stove with flue Brand Name Model No. VENTILATION No. Kitchen Exhaust ducted recirculating cfm No. Bath Exhaust (must be ducted outside) cfm No. Other Fans: Locations cfm FUEL STORAGE (MUST BE APPROVED BY FIRE MARSHAL) Installation Removal Fuel oil: gallons underground inside outside LP Gas: gallons Other Gas opening PER-IIT FEE CALCULATION 1. 1.25% of Contract Price* or Minimum Fee ($35.00) j D�ooy x .0125 $ 167— (contract price) 2. State Surcharge. ** Add the State Building.Code Division Surcharge to each permit. x .0005 $ 5 )l7 or $.50, whichever is greater (contract price) 3. Postage and Handling (Only mail-in applications) $ 1.50 4. TOTAL PERMIT FEE (Add lines 1-3 above) $ a * CONTRACT PRICE or JOB COST means the actual or estimated dollar amount charged for the permitted work including materials, labor,profit, and other fixed costs. It is the amount to be charged to the customer for the work done. If any material, equipment, labor, or installation are furnished by the owner, tenant or any other party the reasonable market value of such items must be added to the estimated cost or contract price for permit fee purposes. In the event that there is a dispute on the amount of the job cost, the City may request the submission of a signed copy of the actual contract. ** The STATE SURCHARGE is .0005 of the contract price under$1,000,000 or $.50 - whichever is greater. For valuations over $1,000,000 call the Department of Inspectional Services for the price. The undersigned hereby applies to the City for issuance of a Mechanical Permit, agrees to do all work in strict accordance with the ordinances of the City and the regulations of the Minnesota State Building Code, and certifies that all statements_made on this application are complete, true and correct. x- Applicant's Signature: Date: 3 Approved By: Date: RHVAC-Residential&Light Commercial HVAC Loads' Elite Softwa . elopment,Inc. �I mouth Plumbing&Heating DENALI-DEVEAU MiRnea lis,MN 5542&1662 P Cotal Building Summary Loads Comp Seri at ." Descri tion , , .... 4 Quan Loss ain Gain Ga' 3D Window Double Pane Low Emit Wood Frame 682 22,651 0 12,276 12,276 11C Door Metal Polystyrene Core 42 1,816 0 367 367 121 Wall R-19 + 1/2"AsphIt Board(R-1.3) 3021 15,285 0 3,089 3,089 15G Wall 5'or More Below Grade 8/12" BIk+R-11 774 3,062 0 0 0 161 Ceiling R-44 Insulation 1837 3,887 0 1,648 1,648 21A Basemt Floor Tor More Below Grade 1628 3,595 0 0 0 Subtotals for structure: 50,296 0 17,380 17,380 People: 8 1,840 2,400 4,240 Equipment: 300 1,200 1,500 Lighting: 0 0 0 Ductwork: 11,689 0 0 0 Infiltration: Winter CFM: 202, Summer CFM: 236 19,839 4,963 3,773 8,736 Ventilation:Winter CFM: 90, Summer CFM: 90 8,837 1,895 1,441 3,336 Sensible Gain Total: 26,194 Temperature Swing Multiplier: X 1.15 Total Building Load Totals: 90,661 8,998 30,123 39,121 Check Figures i Total Building Supply CFM: 1,394 (2.1 AC/hr) CFM Per Square ft.: 0.315 Square ft. of Room Area: 4,425 Square ft. Per Ton: 1,357 Building Loads Total Heating Required With Outside Air: 90,661 Btuh 90.661 MBH Total Sensible Gain: 30,123 Btuh 77 % Total Latent Gain: 8,998 Btuh 23 % Total Cooling Required With Outside Air: 39,121 Btuh 3.26 Tons(Based On Sensible + Latent) 3.26 Tons(Based On 77% Sensible Capacity) Notes Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. I �/�p`�✓, DATE TIME CITY OF ORON CALLED IN INSPECTION NOTICE SCHEDULED PERMITN0. *_ COMPLETED ADDRESS &g0 4Z 4- OWNER CONTR. TELEPHONE NO. -763 2-,?& 'r/.3 .3 3Z DESCRIPTION 1zliz4,6-o 4 01 FOOTING 11 MECHANICAL RI 18 EXCAV/GRADING/FILLING Q 02 FRAMING 13 MECHANICAL FINAL 19 LAKESHORE/WETLANDS y 03 INSULATION 24/25 WOOD BURNER/FIREPLACE 34 TREE REMOVAL 2 04 WALL BD. 12 WATER HOOK-UP 17 SITE INSPECTION Q 05 FINAL 14 SEWER HOOK-UP 06 PROGRESS 07 DEMO-SITE 27 SEPTIC MAINT. 21 COMPLAINT v 07 DEMO-FINAL 15 SEPTIC INSTALL. 22 FOLLOW-UP 09 PLUMBING RI 23 SEPTIC FINAL 35 HARD COVER REMOVAL v 10 PLUMBING FINAL 36 FOUNDATION/REMOVAL Z OWNER/CONTRACTOR TO MEET YOU:_YES_NO y COMMENTS: W a a c 0 2 W cc Q 2 W Z W Z) Cl LU ❑ RK SATISFACTORY:PROCEED ❑PROJECT COMPLETE W CORRECT WORK&PROCEED ❑ISSUE CERTIFICATE OF OCCUPANCY O ❑CORRECT WORK,CALL FOR REINSPECTION TEMPORARY V BEFORE COVERING PERMANENT ❑CORRECT UNSAFE CONDITION WITHIN HOURS. ❑PHOTOTAKEN INSPECTOR WILL RETURN ❑STOP ORDER POSTED.CALL INSPECTOR ❑CITATION ISSUED ❑INSPECTION REQUIRED.CALL TO ARRANGE ACCESS. Call for the next inspection 24 hours in advance. (952) 249-4600 Owner/Contra t Inspector. t White Copyllnspectoes File Canary Copy/Site Notice