HomeMy WebLinkAboutSubsurface Geotechnical Assessment-2008 SUBSURFACE GEOTECHNICAL ASSESSMENT Carlson Family,Estate 460,500,520,550 Tonkana Road Orono,Minnesota Project 2008.053 PREPARED BY SPC ENGINEERING,PA 1296 HUDSON ROAD ST PAUL,MN 55106 June 17, 2008 SPC ENGINEERING & TESTING,INC. 4764 EUROPA TRAIL HUGO,MN 55038 651.653.6349 June 17, 2008 Project 2008.053 Carlson Family Estate 460,500, 520, 550 Tonkana Road, Orono,Minnesota OBJECTIVES AND SCOPE OF SERVICES SPC Engineering&Testing,Inc.,4764 Europa Trail,Hugo,Minnesota,55038 was retained by Construction Consulting & Inspections, Limited, herein after referred to as the "Client", to perform a subsurface geotechnical assessment on a parcel of land located at the address in the above title block.The purpose of this investigation is to identify and evaluate soil properties on the site with respect to re-constructing the existing bituminous street and driveways,thereon. June 12, 2008, five soil borings were performed to nominal depth of 11.5±feet within the project area at locations directed by the client. From the resulting data recommendations are presented regarding pavement design. SCOPE OF SERVICES The client authorized the following scope of services: Perform five(5) standard penetration test boring to nominal depths of be 11.5±feet below grade or refusal. Sample soil using a 2"O.D.split-barrel sampler driven into the soil by a 140 lb weight falling 3 0".After an initial set of 6",the number of blows required to drive the sampler an additional 12"is known as the penetration resistance or N-value.The N-value is an index of the internal friction of cohesionless soil, the consistency of cohesive soils, and the density of all soils. Sampling will conform to the methods set forth in ASTM procedure D1586-84. Classify recovered soil samples by the Visual-Manual method in accordance with ASTM D- 2488. Representative portions of the samples may be submitted to the laboratory for further examination and for verification of the field classification in accordance with ASTM D2487- 85. Information indicating depth and identification of the various strata,the N-value,water level information and pertinent information regarding the drilling method will be documented on comprehensive soil boring logs. Prepare an engineering report including a log of each boring along with our recommendations for allowable soil bearing pressures and estimates of foundation settlement. The purpose of this report is to present the results of our field and laboratory exploration assessment and the associated engineering review.Please note that this report is for geotechnical purposes only and is not intended to document the presence or absence of any environmental contaminants that could be present at the site. 1 SITE OBSERVATIONS The site is currently developed with homes, street and driveways. BORING LOCATIONS AND ELEVATION The number of borings and their locations were determined by the Client, as shown on the enclosed Site Drawing. Please refer to the Site Drawing attached to this report for a sketch of the boring locations. FIELD INVESTIGATION The borings were accomplished using the Standard Penetration Test (SPT) method of investigation using a Split-Barrel Sampler(SBS). An attachment describes the soil classification system used(Unified). SOIL BORING RESULTS Refer to the individual boring logs for a detailed description of soils and moisture conditions encountered. Attached to the soil boring logs is a key explaining terms and entries. The depth of individual layers of soils may vary somewhat from those indicated on the logs due to unsampled intervals between split-barrel sampler tests and, most importantly, the occurrence of transition between soil layers. Also,soil profiles not in the vicinity of the borings may vary. Refusal to auger advancement was not encountered at the boring locations indicating lack of bedrock to depths tested. Groundwater was not encountered as indicated in the soil boring logs. The water level checks were performed at the completion of the boring and at varying times after the boring.The recordings are depicted in the boring logs. Groundwater levels may occur and vary according to various climatological and meteorological influences undetermined within the tie frame, scope and budget allowed in this investigation. In addition,area development patterns can influence groundwater. The indicated groundwater results are for conditions at the time of testing only. CONCLUSIONS AND RECOMMENDATIONS The following conclusions and recommendations are based upon interpreted results of boring logs,their relation to the planned work,and other information. Because the borings represent a small portion of the site in relation to the proposed area of work, ongoing review of construction should be carried out. If excavations reveal subsurface soils of a different nature than those observed in the boring,the Geotechnical Engineer should be contracted for possibly revised recommendations. 1. Pavement Subgrade Preparation We refer to the attached sheet entitled "Bituminous Pavement Subgrade Preparation and Design"for information on pavement design and subgrade preparation including items such as test roll evaluation, subgrade drainage and compaction recommendations. 2 The subsoils in the upper 3 feet of the existing street and driveway as indicated in the soil boring logs and as discussed below; Borings 1,2,3,4,and 5 subsoils under the existing Bituminous, Class 5 Gravel and silty sand fill (found in Borings 2 and 3) consist of sandy clay (Sandy Clay Loams AASHTO A-4 or Clays AASHTO A6). After removal of the existing bituminous pavement section the stability of the pavement subgrade should be evaluated by means of a test roll prior to paving. All unstable areas of subgrade should be removed and replaced with additional class 5 aggregate. The bottom of the subgrade should be compacted prior to adding new aggregate base material.New fill should be compacted per the Specified Density Method (MnDOT Specification 2105.3fl). Streets and driveways should have clearance from maximum anticipated groundwater levels. This groundwater clearance, as practical, should be three feet or more from known groundwater level. Soil Boring ground water elevation measurements indicate that this guideline has been met. Mottled soil as indicated in the Soil Boring Logs indicates seasonally saturated ground water levels near the existing ground surface. Subsurface drains could be installed to increase pavement life if the clients construction budget, existing topography and connections onto existing drainage structures make it practicable. 2. Pavement Section Thickness Designs The thickness of pavement section will depend on the type of material present within the upper portion of the subgrade. It is assumed that this subgrade material will consist of the existing clays or sand loams found on this site. In this report,we recommend the pavement design be based on an assumed R-value of 20, AASHTO Soil Type A-4 or Clays AASHTO A6. MATERIAL Section Thickness Section Thickness Car Parking Areas Roadway Areas Bituminous Wear (Type 41) 1 '/2" 1 ''/i" Bituminous Base (Type 31) 1 '/2" 1 '/z" Class 5 Aggregate Base (MnDOT 3138) 8" 8" Geo-fabric reinforcement* None Yes *Installed as per manufactures recommendation. 3. Limitations of Investigation The Geotechnical Engineer has prepared this report using an ordinary level of care and in accordance with generally accepted foundation and soil engineering practices. Because the borings represent only a small portion of the total site and for other reasons, SPC Engineering& Testing, Inc.,does not warrant that the borings are necessarily representative of the entire site but 3 only of the boring locations at the time of investigation. No warranty of the site is made or implied. The boring logs should only be used in preliminary design and estimating work and in conjunction with corrective procedures. The scope of this report is limited strictly to geotechnical issues which include the establishment of soil profile and only those conclusions expressly made. Please note that this work is not intended to document the presence or absence of any environmental contaminants at the site, nor for identifying applicable local, state or federal laws or regulations of a on- geotechnical nature which may or may not be applicable to this site. Further, SPC Engineering & Testing, Inc., will not be held responsible for facts not disclosed to the Geotechnical Engineer. The bore hole voids were backfilled by Development Engineering using native cuttings or sealed as per the Minnesota Department of Health Rules. Some continuing settlement may occur if construction does not take place in the near future. If settlement does occur, the Client should backfill with additional material. This report and all supporting information is furnished only to the Client and his assigns for the designated purpose. No representations to other parties or for other uses are made. Soil samples retrieved during the investigation process will be retained in the office of SPC Engineering&Testing, Inc. for a period of 30 days from the date of testing. After 30 days from the date of testing. After 30 days,the samples may be discarded unless a request is received to retain for a longer period. ENGINEER'S CERTIFICATE I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly registered Professional Engineer under the Laws of the State of Minnesota. SPC ENGINEERING& TESTING, INC. Todd C. Wille,PE Minnesota Registration No. 25058 4 SOIL BORING LOG DEVELOPMENT ENGINEERING , PA 1296 Hudson Road St Paul,Mn 55106 PROJECT: Carlson Estate LOG OF BORING NO: 1 DEPTH SURFACE ELEVATION: GEOLOGY N WB SAMPLE LAB&OTHER TESTS IN FEET DESCRIPTION&CLASSIFICATION # TYPE R W DEN L.L./P.L. 1 (0'4')Ashalt Pavement Section - (4"-5') Dark Brown, Sandy Clay with a little 2- Gravel(CL). Moist. Medium Glacial Till 3- 7 N 1 SBS 12 4- 5- (6-11.5') Brown, Silty Clay with a little 6- Gravel (CU. Moist. Stiff 10 N 2 SBS 11 7- 8- Medium and Mottled at 7.5 feet 8 N 3 SBS 14 9- 10- Stiff at 10 feet 11- 9 N 4 SBS 16 12- End of Boring at 11.5 feet. No Refusal. 13- 14- 15- 16- 17- 18- 19- 20— WEATHER: Sunny 21-1 1 TEMP: 80o WATER LEVEL MEASUREMENTS DRILLING DATA UKILLIPOW SAMPLED CASING CAVE-IN MUD DATE TIME(HRS) DEPTH DEPTH DEPTH LEVEL WATER LEVEL CREW CHIEF: BR 6/12/08 1:00 11.5' 10' N/A N/A DRY BCR METHOD: 3 1/4" HAS 6/12/08 11:45 9' DRY ACR 2"OD SBS F-350/CME 45B BORING COMPLETED: I 6/12/08 SOIL BORING LOG DEVELOPMENT ENGINEERING , PA 1296 Hudson Road St.Paul,Mn 55106 PROJECT: Carlson Estate LOG OF BORING NO: 2 DEPTH SURFACE ELEVATION: 819.97 GEOLOGY N WB SAMPLE LAB&OTHER TESTS IN FEET DESCRIPTION&CLASSIFICATION # I TYPE R W DEN L.L./P.L. -4" Ashalt 4"- Pavement Section 1- 10" Limestone Class 5 Gravel (10"-2.5')Brown,Silty Sand with Class 5 Gravel 2- (SM),Moist FIII 3- (25-11.5)Brown,Sandy Clay with a little Gravel 8 N 1 SBS 12 (CL),and with fine grained sand laminations(SP), 4- Mottled,Moist,Medium Glacial Till 5- at 5 feet no sand laminations 6- 7 N 2 SBS 14 7- 8- 7 N 3 SBS 14 9- 10- 11- 8 N 4 SBS 16 12- End of Boring at 11.5 feet. No Refusal. 13- 14- 15- 16- 17- 18- 19- 20- WEATHER: Sunny 21- TEMP: 80o WATER LEVEL MEASUREMENTS DRILLING DATA UKILLINU SAMPLED CASING CAVE-IN MUD DATE TIME(HRS) DEPTH DEPTH DEPTH LEVEL WATER LEVEL CREW CHIEF: BR 6/12/08 12:00 11.5' 10' N/A N/A DRY BCR METHOD: 3 1/4" HAS 6/12/08 12:45 9' DRY ACR 2"OD SBS F-350/CME 45B BORING COMPLETED: 6/12/08 SOIL BORING LOG DEVELOPMENT ENGINEERING , PA 12%Hudson Road St Paul,Mn 55106 PROJECT: Carlson Estate LOG OF BORING NO: 3 DEPTH SURFACE ELEVATION: 819.97 GEOLOGY N WB SAMPLE LAB&OTHER TESTS IN FEET DESCRIPTION &CLASSIFICATION # TYPE R W DEN L.L./P.L. -6" AshaR 6"-1Pavement Section 1' I Class 5 Gravel (1'-2.5') Dark Brown, Silty Sand, Gravelly 2- (SM). Moist Fill 3- (2.5'-11.5') Brown, Sandy Clay with a little Glacial Till 7 N 1 SBS 14 4- Gravel(CL), Mottled, Moist, Medium 5- 6- 8 N 2 SBS 16 7- 8- 8 N 3 SBS 12 9- 10- 11- 8 N 4 SBS 15 12- End of Boring at 11.5 feet. No Refusal. 13- 14- 15- 16- 17- 18- 19- 20- WEATHER: Sunny 21- TEMP: 80o WATER LEVEL MEASUREMENTS DRILLING DATA WKILLINU SAMPLED CASING CAVE-IN MUD DATE TIME(HRS) DEPTH DEPTH DEPTH LEVEL WATER LEVEL CREW CHIEF: BR 6/12/08 11:00 11.5' 10' N/A N/A DRY BCR METHOD: 3 1/4" HAS 6/12/08 11:45 9' DRY ACR 2"OD SBS F-350/CME 45B BORING COMPLETED: 6/12/08 SOIL BORING LOG DEVELOPMENT ENGINEERING , PA 1296 Hudson Road St.Paul,Mn 55106 PROJECT: Carlson Estate LOG OF BORING NO: 4 DEPTH SURFACE ELEVATION: 819.97 GEOLOGY N WBSAMPLE LAB&OTHER TESTS IN FEET DESCRIPTION&CLASSIFICATION # TYPE R W DEN L.L./P.L. Ashalt s"-1' Pavement Section 1- Limestone Class 5 Gravel (1'-7.5') Grey, Sandy Clay with a little 2- Gravel (CL), Moist, Medium Glacial Till 3- 7 N 1 SBS 12 4- 5- 6- 8 N 2 SBS 14 7- 8- (7.5'-10')Brown,Silty Clay(CL)with Gray,fine 7 N 3 SBS 14 grained Sand laminations(SP),Mottled,Moist, 9- Medium 10- (10'-11.5')Brown,Sandy Clay with a little Gravel 11- (CL),Mottled,Moist,Stiff 10 N 4 SBS 14 12- End of Boring at 11.5 feet. No Refusal. 13- 14- 15- 16- 17- 18- 19- 20- WEATHER: Sunny 21- 1 TEMP: 80f WATER LEVEL MEASUREMENTS DRILLING DATA UKILLIN SAMPLED CASING CAVE-IN MUD DATE TIME(HRS) DEPTH DEPTH DEPTH LEVEL WATER LEVEL CREW CHIEF: BR 6/12/08 10:00 11.5' 10' N/A N/A DRY BCR METHOD: 3 1/4" HAS 6/12/08 10:45 9' DRY ACR 2" OD SBS F-350/CME 45B BORING COMPLETED: I 6/12/0$ SOIL BORING LOG DEVELOPMENT ENGINEERING , PA 1296 Hudson Road St.Paul,Mn 55106 PROJECT: Carlson Estate LOG OF BORING NO: 5 DEPTH SURFACE ELEVATION: 819.97 GEOLOGY N WB SAMPLE LAB&OTHER TESTS IN FEET DESCRIPTION &CLASSIFICATION # I TYPE R W DEN L.L./P.L. '-6" Ashalt 6"4Pavement Section 1' Class 5 Limestone Gravel 2- (1'-11.5') Brown, Sandy Clay with a little Glacial Till Gravel (CL), Mottled, Moist, Medium 3- 6 N 1 SBS 12 4- 5- Stiff at 5 feet 6- 10 N 2 SBS 15 7- 8- 10 N 3 SBS 16 9- 10- 11- 10 N 4 SBS 16 12- End of Boring at 11.5 feet. No Refusal. 13- 14- 15- 16- 17- 18- 19- 20- WEATHER: Sunny 21-1 TEMP: 80f WATER LEVEL MEASUREMENTS DRILLING DATA UKILLINU SAMPLED CASING CAVE-IN MUD DATE TIME(HRS) DEPTH DEPTH DEPTH LEVEL WATER LEVEL CREW CHIEF: BR 6/12/08 9:00 11.5' 10' N/A N/A DRY BCR METHOD: 3 1/4" HAS 6/12/08 9:45 8' DRY ACR 2"OD SBS F-350/CME 45B BORING COMPLETED: 1 6/12/08 SOIL BORING LOG PROJECT: BORING I:Oc-']= LOG OF BORING NO: DEPTH SURFACE ELEVATION: SAMPLE LAB i OTWER TESTS IN GEOLOGY N WB L_L_ FEET DESCRIPTIONAN0CLASSIFIGATION I TYPE R W DE p L 1 ► 2I t 3 � I � 4 � t 6I 4 t fi 7 I Soil Classificatibn, using Origin \ Other t visual-manual and/or labora- of Soil \ Data as 8 tor;r'.methods� atc4rding to the necessary t I Unified Soil Classification ' 9 System, or to other system as _ Atterberg t J appropriate Limits{ 10 Penetration "N" I Value - Number of blows to drive Densitey* ! Split-Barrel Sam- 12-1 pler one foot pcf l 13-' ater Bearing Moisture Content ! ( Y = Yes N = No 1 � � 15- Water ! Level I Svmbol 16J Length of Sample ' Recovered Sample Number 17' i - Indicates Type 18 . of Sample: ; SBS = Split-barrel 1 i FA = .Flight Auger * = Lab test on 20 HA - Hand Auger recovered sample ST - Shelby Tube 21 (thinwall) WATER LEVEL MEASUREMENTS T DRILLING DATA , SAMPLED CASING CAVE-0d Omit-LING WA"ER - DATE TIME Or PVT" DEPTM of FT" r110 LEVEL LEVEL Cray.CAlet Metmod. I UNIFIED SOEL CLASSIFICATION Group wjatr DFsi�om Typical taamet Laboratory ckassificatioa Qiteria GV1, Weil-grades gravels gravel-sand Cu-D=greater than 6:Cc<(D'J� between I and 3 c mixtures. little or no fines O.. D.atD— ` ' rPoorly graded gravels,gravel- „ c c GP sand mixtures,:iuk or no fines Not meeting all gradation requirements for GW _ V _O = ` Z — Get d �. .. — Silty gravels,gravel-sand elft = 3 Atterberg limits below a� e _ — mixturts = line or P.I. less than a A / u .: a Above •A' lire with P.J. ::�::? between 3 and 7 are bor- t Z 3 = w deri— .zses requiring use e C: a Atererg limits abve"A"GC Clayey�gravels.gravel-sand-cby of dual symbols t o n r mixtures =_ line with P.I.greater than 7 ;L.2 G w SW Well-graded sands. gtaselly — e Cu=D=grease than a:Ce.(D'-e bet-e-n 1 and 3 sands.little or no fines a D. D.tD_ : 3 Y "'= SP Poorly graded sands.gravelly : sands little or no lines c 3 -Not meeting all gradation reauiremm%for SW "J V t Z O �` y C Y t = ? SM dc= Anerberg limits below "A'• _ Q _ Silty sands.sand-sat c :, matures a� - line or P.I.las than s Limits plating in hatched u t o c zone with P.J. between s 3 = YC J L N and l am borderline cases a;5 requiring use of dual sym- SIC Clayey sands.sand<lay aix- 4_ AtsQ�g limits above•A" boas < lures X^'o line with P.I.gr Mur than 7 Inorganic silts and vm fine HL sands.rock flour.silty or darn• fine sands or ciavev silts with60 t t slight plasticity For etusifi=ton of fax-grained .�. wds and fine fraction of coarse- I C Inorganic clays of l(r-to me• s0 graifed;,ails. z dium plauicity,gravelly days Atterberg Limns plotting in + t �+ hatched area are bonle!ltne [lass•CL M 1 1 sandy days.Silty'days.lean ifieattorts requiring use of dual i c Y / .= days 40 tyntoots. I t Ec aticn of A4ww: t ,�.. PI X0.'3 tLL-St t e ' OL Organic sibs and organic silty Z _ class of low plasticity 10 1 r s s t • Inorganic sills.mxauww or (nM"aa0 MM l a SIH diatomaceous free sandy or 4 20 t Silty soils.elastic silts t l i t CL t t s,a _ t e v CH Inorganic days of high pias- 10 t may.fat days 7 s 7 = 4 ___ct►3i��1� MI.w etc . e S OH Organic days of medium to 0 10 70 70 40 50 60 70 10 90 100 _ j Nigh plasticity.orgartsc silts S=_ Pi Peat and Other highly or ac Liquid Urut o` g stotl: Ptastt•:uy Gert GENERAL TERMINOLOGY NOTES FOR SOIL IDENTIFICATION AND DESCRIPTION GRAIN SIZE GRAVEL PERCENTAGES Tenn ASTM Term Percent Boulders Over 12" A little Gravel 3%to 15% Cobbles 3"to 12" With Gravel 15%to 30% Gravel #4 sieve to 3" Gravelly 30%to 50% Sand #200 to 44 sieve Fines(silt and clay) Pass#200 sieve CONSISTENCY OF PLASTIC SOILS RELATIVE DENSITY OF NON-PLASTIC SOILS Term N-Value. BPF Very Soft less than 2 Tenn N-Value,BPF Soft 24 Ven Loose 0--4 Medium 5-8 Loose 5-10 Stiff 9-15 Medium Dense I 1-30 Very Stiff 16-30 Dense 31-50 Hard Greater than 30 Very Dense Greater than 50 MOISTURE/FROST CONDITION LAYERING NOTES. D(Dry): Absence of moisture,dusty,dry to touch. Laminations: Layers less than'/"thick of M(Moist): Damp; although free water not differingmaterial or color. visible. Soil may still have a high water content(over`optimum"). Lenses: Pockets of layers greater than'/2" W(Wet/ thick of differing material or color. Waterbearing): Free water visible. Intended to describe non-plastic soils. F(Frozen): Soil frozen. FIBER CONTENT OF PEAT ORGANIC DESCRIPTION Tenn Fiber Content(Visual Estimate) Fibric Greater than 67% Non-peat soils are.described as organic, if soil is Hemic 33 to 67% judged to have sufficient organic content to influence Sapric Less than 33% the soil properties. BITUMINOUS PAVEMENT SUBGRADE PREPARATION AND DESIGN GENERAL Bituminous pavements are considered layered`flexible" systems. Dynamic wheel loads transmit high local stresses through the bituminous/base onto the subgrade. Because of this,the upper portion of the subgrade requires height strength/stability to reduce deflection and fatigue of the bituminous/base system. The wheel load intensity dissipates through the subgrade such that the high level of soil stability is usually not needed below about 2'to 4' (depending on the anticipated traffic and underlying soil conditions). This is the primary reason for specifying a higher level of compaction within the upper subgrade zone versus the lower portion. Moderate compaction is usually desired below the upper critical zone,primarily to avoid settlements/sags of the roadway. However,if the soils present below the upper 3' subgrade zone are unstable,attempts to properly compact the upper 3'zone to the 100%level may be difficult or not possible. Therefore, control of moisture just below the 3'level may be needed to provide a non-yielding base upon which to compact the upper subgrade soils. Long-term pavement performance is dependent on the soil subgrade drainage and frost characteristic. Poor to moderate draining soils tend to be susceptible to frost heave and subsequent weakening upon thaw. This condition can result in irregular frost movements and"popouts," as well as an accelerated softening of the subgrade. Frost problems become more pronounced when the subgrade is layered with soils of varying permeability. In this situation.the free-draining soils provide a pathway and reservoir for water infiltration which exaggerates the movements. The placement of a well drained sand subbase layer as the top of subgrade can minimize trapped water. smooth frost movements and significantly reduce subgrade softening. In wet, layered and/or poor drainage situations.the long-tenni performance gain should be significant. If a sand subbase is placed,we recommend it be a"Select granular Borrow"which meets Mn/DOT specification 3149.2B. PREPARATION Subgrade preparation should include stripping surficial vegetation and organic soils. Where the exposed soils are within the upper"critical" subgrade zone(generally 2 '/2 deep for"auto only" areas and 3'deep for"heavy duty" areas).they should be evaluated for stability. Excavation equipment may make such areas obvious due to deflection and rutting patterns. Final evaluation of soils within the critical subgrade zone should be conducted by test rolling with heavy rubber-tired construction equipment,such as a loaded dump truck. Soils which rut or deflect 1 or more under the test roll should be corrected by either subcutting and replacement; or by scarification, drying. and recompaction. Reworked soils and new fill should be compacted per the"Specified Density Method" outlined in Mn/DOT Specification 2105.3171. Subgrade preparation scheduling can be an important consideration. Fall and Spring seasons usually have unfavorable weather for soil drying. Stabilizing non-sand subgrades during these seasons may be difficult,and attempts often result in compromising the pavement quality. Where construction scheduling requires subgrade preparation during these times.the use of a sand subbase becomes even more beneficial for constructability reasons. SUBGRADE DRAINAGE If a sand subbase layer is used, it should be provided with a means of subsurface drainage to prevent water build- up. This can be in the form of draintile lines which tap into storm sewer systems,or outlets into ditches. Where sand subbase layers include sufficient sloping, and water can migrate to lower areas,draintile lines can be limited to finger drains at the catch basins. Even if a sand layer is not placed, strategically placed draintile lines can aid in improving pavement performance. This would be most important in areas where adjacent non-paved areas slope towards the pavement. Perimeter edge drains can aid in intercepting water which may infiltrate below the pavement. !"IN Ir LAKE MINNETONKA ► / / f` i�- J %' %' , i i _ HOUSE �_�r � ',, i- ' Ali ' � �_ �._ ��• f ' \� �' : Aj BRYANT REDROCK ' - •' �"=� ` SURFACE NOTE .PREFERRED CONFIGURATION FOR A b PATH WOULD NOT REQUIRE RETAINING WALLS. IF GRADES6 HOUSE TE BECOME TOO SEP AND WALLS ARE NECESSARY,"CONTRACTOR SHALL PROVIDE PRECAST RETAINING` WALL �p i ' R% p 9 1 0 11 4 SYSTEM. CONTRACTOR SHALL RECEIVE APPROVAL-FROM — LANDSCAPE ARCHITECT*AND OWNER FOR A PROPOSED GRADE AND LOCATION PRIOR TO INSTALLATION. - - NOTE ' 1� i ;O.\ \ -- t _ �3(room f ! CONTRACTOR SHALL STAKE THE LOCATIONS OF TREES TO RECEIVE APPROVAL BY 1 1 LANDSCAPE ARCHITECT AND OWNER I - ) C ! j PRIOR TO INSTALLATION. Sugar Maple HOUSE y , • �. Copper Spruce EIAT0&- i LOCATION 0 Cal 10 POND'i i 'o, , TONKAWA ROAD