Loading...
HomeMy WebLinkAbout1986-5895 - new residence CITY of ORONO Building Permit PERMIT NO. 5895 ' AND APPLICATION FOR CERTIFICATE OF OCCUPANCY DATE ISSUED /--,3j-y4 P.O. BOX 66, CRYSTAL BAY, MN 55323 473-7357 ZONING DISTRICT SITE ADDRESS Ll799 Np Sh0►-e �►- 'L PROPERTY IDENTIFICATION NO.(PID) 02--//7" -13" 00 3 FIRE DEPARTMENT LOT BLOCK SUBDIVISION POST OFFICE OWNER (Name) (Address) (Phone) FS A , �t/• a o-3�s VAR. DATE ARCHITECT/ENGINEER- Must Certify Multi-Family,Commercial& Industrial Construction Plans (Firm) (Address) (Phone) COND. USE DATE LOT AREA BUILDER (Firm) (Address) (Phone) PT Z f}� _rD. (L ji PL ES WIDTH r DEPTH / TYPE OF WORK Lew: Addition Remodel Renovate PROPOSED SETBACKS: / FRONT / R.SIDE REAR L. SIDE CONST.TYPE BUILDING SIZE E�timated Construction Valuation � i LAKE WETLANDS L. W Ht. S $3 0490 • 00 OCCUPANCY PERMIT FEES CLASSIFICATION 9 ACCESS ro4k,4W DWELL. STORIES B 1 2 3 BLDG. PERMIT � X�• Da ✓ *1 P1 UNITS STATE FEE 7 �O NEW EXISTING a PET.' STALLS NUMBER OF BEDROOMS AGENCY-APPROV. DATE/' I, 3 PLAN REVIEW �� D O CITY SEPTIC SAC CHARGE i O Z) APP. DATE _ COUNTY PROPOSED USE SEWER UNIT �.�J. 00 STATE PARK FEE 00 PRIVATE EASEMENT COUNCIL PENALTY I— �:] APP. DATE OTHER REMARKS: TOTAL DUE e�O l _I �J INSPECTION REQUIRED WORK REQUIRING ACKNOWLEDGEMENT SEPARATE PERMITS . ... FOOTING before pour THE UNDERSIGNED HEREBY REQUESTS PERMISSION TO MAKE . .... FRAMING rough-in PLUMBING ......................... . THE REAL IMPROVEMENTS SPECIFIED. AND DECLARES . . ... INSULATION MECHANICAL....................... lA UNDER PENALTY OF LAW ACKNOWLEDGEMENT AND ACCEPT- . . . .. before tapingWELL................................ ANCE OF ALL INFORMATION, CONDITIONS AND REQUIRE- . .. .. FINAL before occupancy ❑ . . . . .. SITE INSPECTION SEPTIC.............................. MENTS REPRESENTED ON THIS DOCUMENT. THE UNDER- WORK BEYOND OR WITHOUT A RE- SEWER.............................. ❑ SIGNED FURTHER AGREES TO DO ALL WORK IN STRICT COM- QUIRED INSPECTION WILL BE SUB- WATER.............................. ❑ PLIANCE WITH ALL CITY OF ORONO ORDINANCES AND STATE JECT TO PENALTY. GRADING&FILLING ............... OF MINNESOTA BUILDING CODE REQUIREMENTS. ❑ INSPECTIONS MUST BE CALLED-IN 24 HOURS IN ADVANCE. FIRE................................. ❑ , /� ////� Signature J /lY [ Q� ��, Date COPY:WHITE-FILE GREEN-FINANCE CANARY-INSPECTOR GOLD-RECEIPT PINK-ASSESSOR Approvedli�ECity of Orono Brooklyn Prtg.&Adv.Co.Inc. (612)561-4470 CHEC&FF LIST FOR ISSUANCE OF Pi ITS FOR OFFGI�CE USES ONLY ADDRESS OR LEGAL DESCRIPTION: ' / 7 / 8 / �/oa2� PID: DESCRIPTION OF WORK: --------------------- -- _ ------- ------------------------------------------- ZONING REVIEW BY: DATE APPROVED: BUILDING REVIEW BY: DATE APPROVED ,/, /0 " PERMIT ISSUED BY: DATE: FEES TO BE CHARGED: / Misc. Fees Calculated By: PERMIT Yes 1No SEWER UNIT $ 0 + W IpLwzM tT*r�� PLAN REVIEW Yes 7 No SEWER CONNECTION STATE SURCHARGE Yes ✓ No WATER CONNECTION PENALTY Yes No PARK FEE vJ SAC Yes No SITE INSPECTION i� OTHER (specify) �� ---- ZONING CHECK LIST Zoning District: I-le-- 1-9 Fire Department: PAOUVb Post Office: r-WVAIL School District: t"-0 ,k1C> Lot Area: d LZ AC- Width: P cl�(-f- Depth: ' 3o I + Survey Submitted: Yesx No Date of Survey: Proposed Setbacks: 1 r Front � : J� Right Side: r Rear (Street) : Left Side: Z Qr Adjacent Structures: /`10N�� Wetland: Existing Proposed Hardcover: 0-75' 75-250 ' 2---o-Svo Na►�s-- r Hardcover Variance Required: Yes No Date of Council Approval: JA Grading: Staff Approval Date: NO(- By: Council Approval Date: Septic: Staff Approval Date: ----- By: -' Zoning File: _ Resolution #: 17V Resolution Date: La- REMARKS (in house) : BUILDING REVIEW CHECK LIST UBC: CG. 2RUCTION TYPE: BLDG SIZE: A. � L. W. �1'3 � Sq. Footage: Estimated Construction Value S� 1st Floor f 2 x 46 . 0 = 3747. 3 - 2nd Floor - x - x Garage 57 7 x = t ,yZ TOTAL x = Inspections Required: Work Requiring Separate Permits: Site Plumbing Grading/Filling Footing Mechanical Fire Framing Well Water Connection Insulation Septic Sewer Connection Wall Board Fireplace Other Final ------------------------------------------------------------------- REMARKS (IN HOUSE) : --------------------------------------------------------------------- REVIEW BY OTHERS: DATE: Access: Existing New Access Approval: Date By: - --------------------------------------------------------- REMARKS (TO BE NOTED ONP T) : LJ 111 Vt � Iv.IV BUTT-DING FER?iIT APPLICATION BUILDING PERMIT APPLICATION REQUIREMENTS Requirements to be handed in with Building Permit Application: Construction Plans should include: 1. Building Permit Application - to be filled out & signed 1. First floor plan 2. Mechanical Permit Application & Calculation filled out 2. Footing & foundation plan 3. Energy Calculations - filled out 3. Elevations (of all sides) 4. Furnish Septic Report & Design 4. wall sections & cross sections 5. Furnish a Certificate of Survey, including hardcover calculations 5. Details - stairs and any special connection: and grading and drainage plans as required. 6. Furnish 2 sets of Construction Plans: a) 1 set for City to keep on file b) 1 set for builder to use on site THE ABOVE INFORMATION MUST BE SUBMITTED BEFORE PLAN REVIEW IS DONE Work beyond or without a required inspection will be subject to a penalty CITY USE ONLY SITE ADDRESS BUILDING PERMIT N O. DATE LEGAL DESCRIPTION:PROP.ID. I LOT _ BLOCK_ _._ SUBDIVISION ZONING DISTRICT WNER (Name) (Address) (Phone) p FIRE ZONE I'1.1 Vti > I .� ✓�--' -��� �XI ..�!i -3,3/5 t'l vAR.OATE ARCHITECT/ENGINEER — Must Certify Multi-Family, Commercial & Industrial Construction Plans ERT.NO. GOND.USE DATE (Firm) (Address) (Phone) LOT AREA V,qZ A-C. _.1 �J�}"Y" � S � a �� FS / �E•So `/ �0-33 95 WS7,0 E DEPTH �V E 1 BUILDER (Firm) (Address) (Phone) PROPOSEDSETBACKS I F 0 R.StDE +1 REAR LSIDE 4- *^- TYPE OF WORK r144 Addition Remodel Renovate LAKE WETLANDS Q�A ACCESS NEW EXISTING G SIA CONST.TYPE BLDG.SIZE ESNST.VALUATION AGENCY-APPROV.DATE CITY ✓ L. W. 02 6 Ht. couNTv RESIDENTIAL STORIES B 2 3 STATE REMARKS: I PR.EASEMENT DWELL. BDRMS/FLR UNITS 3 GAR.STALLS SEPTIC PERMIT FEE d ATT , _. APP.DATE ` BLDG.PERMIT STATE FEE DET. DOCK PLAN REVIEW NON-RESID. PROPOSED USE PENALTY PARK FEE O`.C,. SACCHARGE _ CLASS. .r a vtN► STORIES COUNCIL TOTAL D i -- APP.DATE INSPECTION REQUIRED WORK REQUIRING The undersigned hereby makes application for a building FORTING WI—Po.' SEPARATE PERMITS FRAMING,."h.. permit for the work described, agrees to do all work in strict INSULATION PLUMBING,/ accordance with the ordinances of the City of Orono and rulings WALLBOARD 0.1—Tp,.@ MECHANZAL_1-1 ''. Of the State Building Code Division, and declares that all FINAL W —0—vIo,$ l—v ELL X j facts and representations stated herein are true and correct. SEPTIC WORK BEYOND OR WITHOUT A RE. SEWER OUIRED INSPECTION WILL BE SUB- WATER JE�1R TO PENALTY, 2Y hour notice GRADINGB FILLING Y U Dee Signature on all insp. ELECTRICAL I—S.. sVbmlHO •/-b•Y(O CHECK OFF LIST FOR ISSUANCE OF PERMITS AV-74 0 AlL.00=00 A<Zk Address : 7F f Initial Area of Review Remarks Building Code Review Zoning Review vY, �L , Access a ) State b) Hennepin County C ) City (Public Works Dept ) d ) Private Roads (Public Works Dept ) Utilities (Public Works Department) a) Sewer Now 010 b) Water 1 770 Septic Review l� MCWD LMCD Special Grading Review Engineer' s Review Attorney' s Review Special Assessments Things to be noted on the permit : P JAM TJJ XMPG F-1 JRG F] DMH t EXTERIOR ENVELOPE AVERAGE "U" COMPUTATIO rl� 19$6OWtIE R: SITE ADDRESS: CITY OF ORO CONTRACTOR: DATE PHONE: DETERMINE WORKING SQUARE FOOTAGE OF EACH: 1 . TOTAL EXPOSED WALL AREA, , , , , , . , sq ft x "U" 2. TOTAL ROOF/CEILING AREA, , , . . , . . sq f t x ".uI1 0 A } 3. TOTAL EXPOSED WALL AREA CALCULATIONS: Total exposed wall area above floor, , , , , , , , sq ft t a) Total wall window area: _ glazed, , , , . . I sq ft x "U" zq7 � 6S• 33 glazed. . . . . . sq ft x "U" -- a b) Total door area sq ft x "U" 3Q c) Total sliding glass door area: glazed. . . . . . — sq ft x "U" — a glazed. . . . . , sq ft x "U" "— C d) Total fireplace wall area sq ft x "U" e) Total wall framing area (Average W) . . . . . . . . . . IS3 sq ft x „U" '011 32 f) Total net wall area above floor (Insulated) . . . . . . . sq ft x "U" g) Total rim joist area. . . . . . /2y sq ft x "U" Total foundation area (Exposed) . . . . . . . . . X2`4 sq ft h) Total foundation window area. . . . . . . . . . . . — sq ft x "U" i) Total net foundation area above grade. . . . . . . . sq ft x "U" 0 3' TOTAL a) thru i) If item N3 is the same as, or less than item pl , you have met the intent of 2 14CAR 1.16008 A and 0. Page 1 4, TOTAL EXPOSED ROOF/CEILING CALCULATIONS : Total exposed roof/ceiling area. . . . . , . . 11(� sq ft j) Total skylight area. . . . . . — sq ft x "U" Q Total roof/ceilinq framing area (Average 109,) . . . . . /a0 sq ft x "U" 1) Total net insulated roof/ceiling area. . . . . . . I C) sq ft x "U" .02-L; 4• TOTAL J) thru If total of #4 is the same as , or less than N2, you have met the intent of 2 MCAR 1.16008 A and 0. 1 t _ ALTERNATE BUILDING ENVELOPE DESIGN To utilize the total envelope system methtid, the values established by the sum of items N3 and #4 shall not be greater than the sum of items N1 and #2. + 2. 3 I l oz�. 06 3• — / 7 6,69 + 4. x703 X03,`11 C E R T I F I C A T I O N I hereby certify that I have calculated the "U" factors and "R" values herein and that the building here described meets or exceeds the State of Minnesota Energy Conservation Act. Signature (Date) Page 2 CONSTRUCTION R VALUE WALL FRAMING SECTION: 1 Interior ai/r film 0.68 2 �l L J k-4 3 3y& inches soft wood 3g 4 , o 5 'IMP 7 6 Exterior air If I Im 6. 17 TOTAL R = � U = 1/R = Lott WALL SECTION (INSULATED) 1 Interior air film 0,68 2 3 _3%" I— 4 .� 5hd 1 ,4-7_ F+ Exterior ai r If i lm 0, 17 TOTAL R = I� U RIM JOIST SECTION: I 1 Interior air film 0.68 2 3 _14 , Tt ' 4 00 --�5 _—ft�l 7 :- 6 Exterior air film 0, 17 TOTAL R FOUNDATION INSULATION REQUIRED: Min. R-5 on entire wall OR U = 1/11 Min. R-10 down to frost depth A:. FOUNDATION SECTION: 1 Interior air film 0,6$ '0' , _�2 •,a - :.'• 3 • ' � dd�••',o.�1.4,' 4 Exterior air filmn. r , 17 Q, (S -4 , (6 TOTAL R = 'J U - i/R = 4QZ SLAB ON GRADE ;,-4' •' ,,• ,- . .gyp, Q-47 � , `l' ►' '4 ' 4 ej •• :4. q. Heated Slabs: • . 'd. Minimum R = 8.5 • ' 46 - Unheated ,Unheated Slabs: ,• ,' Q ' ' • : Minimum R = 6.2 4•4-0 ,, • • d D 4 '. ..• o ., .. t • Page 3 CONSTRUCTION R VALUE. CEILING SECTION (INSULATED) : I Interior air film n.61 2 -SL.+,,� sz 3 L3 �..S„s _ 94 00 3 4 4 Exterior air film (still) O.A1 TOTAL R - Jsi U - 1/R - .o2.z CEILING FRAMING SECTION: 2 5 1 Interior air film O,FiI 2 56de.-is I S L AIR VENTED 3 _aioW,, 14TJ 30,00 FLOW 4 Interior air film still 0. 1 inches sof t wood y,3g TOTAL R = 36•I z., U = 1/R - oz II I - CEILING SECTION (INSULATED) : V Interior air film 0.61 2 3 4 Exterior air film still n.61 TOTAL R = J U - 1/R = I 2 3 4 5 CEILING, FRAMING SECTION: 1• Interior air film 0.61 VENTED 2 3 4 Exterior air film still n.6r 5 Inches soft wood TOTAL R - U - 1/R - 3 4 5 Inside air film n.Al II i+ l 1 2 5 Outside air film n, 17 TOTAL R = U - 1/R - Page 4 GUIDELINE TO (R) FACTORS FROM ASHRAE MANUAL ' OF TYPICALLY USED PRODUCTS AIR FILMS (R) SHEATHING Interior Air Film (Walls) 0.68 3/4" Wood Subfloor or Sheathing 0.94 Exterior Air Film (Walls) 0.17 1/2" Plywood Sheathing 0.62 F'Air Interior i Film (Vented Ceiling 0.61 1/2 Particle Board 0.66 I Exterior Air FilmVented Ceilin 1 ( g� 0 6 Gypsum or Plaster Board 3/8 0.32 Interior Air Film (Non Vented 0.61 Gypsum or Plaster Board 1/2" 0.45 Exterior Air Film (Non Vented 0.17 Gypsum or Plaster Board 5/8" 0.56 Plywood 3/8" 0.47 Plywood 1/2" 0.62 BLOWING WOOLS Plywood 3/4" 0.93 Approx. 3" 9.00 Sheathing, Reg. Density 1/2" 1 .32 Approx. 4 1/2" 13.00 Sheathing, Reg. Density 25/32" 2.06 Approx. 6 1/4" 19.00 Nail-Base Sheathing 1/2" 1 .14 Approx. 7 1/4" 24.00 Approx. 14" 30.00 ROOFS Approx. 18" 40.00 Built-up Roofs 0.33 All other insulation materials must Asbestos-Cement Shingles 0.21 be verified (R Factor) Asphalt Roll Roofing 0.13 Asphalt Shingles 0.44 INSULATION . Insulation: 2-2 3/4" Fiberglass 7.00 SIDING Insulation: 3 1/2" Fiberglass 11 .00 Aluminum Siding 0.61 Insulation: 6" Fiberglass 19.00 Aluminum with Backer 1 .82 Insulation: 3 5/8" Fiberglass 13.00 -Aluminum with Backer & Foiled 2.96 Insulation: 9" Fiberglass 30.00 1/2 x 8 Lap Siding Insulation: 12" Fiberglass 38.00 7 x 12 Hardboard (Wood) 0.81 /16 rd Siding 0.67 Insulation: 8" Cellulose 29.00 Asbestos Sidings 1/4 Lapped 0.21 Insulation: 10" Cellulose 37.00 Stucco (Brown and Finish Coat) Insulation: 12" Cellulose 44.00 Insulation: 1 1/2" Thermax 12.00 Insulation: 2" Thermax 16.00 DOORS (U) WOODS 1 3/4" Solid Core Door .46 w/Storm, Wood .31 Fir, Pine & Similar Soft Woods w/Storm, Metal .26 1 1/2" 1 .89 Pease Steel Door Insl/N/GL 7.45R .13 2 1/2" 3.12 Sliding Glass Door, Wood .65 3 1/2" 4.35 Metal .72 5 1/2" 6.87 ONCRETE BLOCK WINDOWS " Concrete Block (S & G Reg. ) 1 .11 All Windows ' (Filled with Vermiculite) 1 .93 (w/Storms 1" to 4" Space) .56 12" Concrete Block (S & G Reg.) 1 .28 Removal Double Glazing (RDG) .55 , (Filled with Vermiculite) 3.15 Thermo or Welded 3/16" Air Space .69 0" Light Weight 2.18 1/4" Air Space .65 i(Filled with Vermiculite) 5.03 1/2" Air Space .58 1I " Light Weight 2.48 (Other windows specifically tested '(Filled with Vermiculite) 5.82 can use better ratings) Page S i I OPTIONAL DESIGN METHOD • 'At an option to completing the Exterior Envolope Average "U" Computation where "U" values have to be calculated, the following method may be used. NOTE: All of the following six items must be accomplished in order to utilize this method. �—;• 1 . Ceilings which meet one of the following criteria satisfy this requirement: A. R-38 throughout the entire ceiling. Indicate on plan section drawing how this will be accomplished. Complete appropriate diagram F, G, or H. B.' If a portion of the ceiling is less than R-38, the insulation in the remainder of the ceiling must be increased to yield an overall average thermal resistance of not less than R-38. C. Where the roof at the perimeter of the ceiling prevents installation of insulation to full depth, the insulation in the remainder of the ceiling must be increased to reduce the overall ceiling heat loss to no more than if R-38 had been installed throughout the entire ceiling. (Submit calculations if this method is used). 2. For the insulated cavity of opaque wall and rim joists, but not foundation walls, a minimum R-20 is required. Complete diagrams B and C. 3. . For the insulated cavity of floors of heated spaces over unheated spaces, a minimum of R-20 is required. 4. Maximum glass area may not exceed 12% of the area of exterior walls not including foundation walls. All windows shall be double glazed or have storm windows. Complete the following equation using data from the first page: 3(a) - 3(t) _ N J. I (x) must be less than .12- to meet requirements of this item. x 5. Maximum glass area may not exceed 10% of the area of exterior walls, not including foundation walls, when a sliding glass door is installed. All glass shall be double glazed or have storm windows. If sliding glass doors are to be installed, complete the following equation using data from the first page: E3(a) + 3(c� . 3(t) _ y Y must be less than .1 m requirements (Y) 0 to eet of this item. 6. A 1 3/4" metal faced door system with an insulated core providing an R value equal to or greater than 3.0 or a conventional door and storm. All primary doors must have durable weatherstripping. I Page 6 7 . 7D Ca,� des ORONO HARDCOVER CALCULATION WORKSHEET LAKESHORE A. Existing B. Existing C. Existing D. Proposed E. Proposed F. Allowed SETBACK lot area hardcover hardcover hardcover hardcover. hardcover ZONE in zone in zone percentage in zone percentage [ (B: . A) x 100] [ (DA) x 1001 Percentage 0-75 ' sf sf % sf % 0 75-250 ' sf sf sf % 25 04, 250-500 ' 18,36SS b sf b /o Z96g sf 90 30 500-1000 ' sf sf % sf % 35 Directions: A. Existing Lot Area in Zone includes the total square footage of dry buildable land within the specified zone . B. Existing Hardcover in Zone - includes the square footage of existing roofs, decks, sidewalks, driveways (gravel or paved) and other rain-impervious surfaces within the specified zone . C. Existing Hardcover Percentage - divide the number in B by the number in A and multiply by 100 . D. Proposed Hardcover in Zone - includes the existing hardcover plus all proposed additional hardcover. E. Proposed Hardcover Percentages - divide the number in D by the number in A and multiply by 100 . F. Allowed Hardcover Percentages - if the percentages in column E for any setback zone exceed the allowed percentages in column F, you should contact the Zoning Department at 473-7357 to discuss the possibilities of obtaining a variance . Generally, if a• concurrent removal of existing hardcover matches the additional hardcover proposed, resulting in no net increase of hardcover in a specified zone, a variance may not be necessary. LAKESHORE REGULATIONS AND HARDCOVER 4. SEC. 10.22. REGULATIONS FOR RLR-IAN,, "LR-lA-1", "LR-1B", "LR-1C" AND "LR-1C-1" ONE FAMILY LAKESHORE RESIDENTIAL DISTRICT. Within any "LR-lA", "LR-lA-1", "LR-1B", "LR-1C", or "LR-1C-1" One Family Lakeshore Residential District the following regulations shall apply: ' Subd. 1. Lakeshore Set Back Regulations. The set back from the shoreline for lakeshore lots shall be at least 75 feet and no building may be located closer to the shoreline than the average distance from the shoreline of existing . residence buildings on adjacent and nearby lots. Subd. 2. Lakeshore Hard Cover Regulations. Within 75 feet of shoreline there shall be no excavating, filling , hard cover, temporary or permanent structures. Within 75 to 250 feet of the shoreline there shall be no greater than 25% hard cover. Within 250 to 500 feet of the shoreline there shall be no greater than 30% hard cover. Within 500 to 1,0.00 feet of the shoreline there shall be no greater than 35% hard cover. Subd. 3. Tree Removal Regulations. No trees within 75 feet of the shoreline with the, diameter of six (6) inches or more shall be removed without first obtaining a permit from the Council. HARDCOVER LIMITATIONS 0-75' Zone - 0% Hardcover allowed 75-250 ' Zone - 25% Hardcover allowed 250-500 ' Zone - 30% Hardcover allowed 500-1000 ' Zone - 35% Hardcover allowed Percentage of hardcover for each zone is calculated as follows: tic, Area of hardcover Zr> ti4� in zone (sq. ft.) ' «+�-0." o`'` — X 1C0 Percentage of _- Plv Area of lot hardcover in zone in zone (sq ft.) NOTE: Measure setback distances perpendicular to the shoreline, not along the lot line . i